Skip to main content

09.05.2017

Novel contrast-injection protocol for high-resolution abdominal CT-angiography: vascular visualization improvement with vasodilator

verfasst von: Minori Hoshika, Kotaro Yasui, Takefumi Niguma, Toru Kojima, Norimi Nishiyama, Daisuke Suzuki, Izumi Togami

Erschienen in: Abdominal Radiology | Ausgabe 10/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate the usefulness of a novel contrast-injection protocol for high-resolution abdominal computed tomography angiography (CTA) using nitroglycerin (NTG).

Methods

Abdominal CTA was performed in 80 patients using two 64-detector-row CT scanners. Forty patients were examined after administration of sublingual NTG (NTG group), while 40 were examined without NTG administration (non-NTG group). Arterial phase images were acquired with maximum intensity projection and volume rendering. Reduction rates: vessel cross-sectional areas ratio of 10 cm distal to origin at the superior mesenteric artery, contrast enhancements, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were assessed. Three reviewers evaluated degree of depiction of the peripancreatic vasculature using a four-point scale (1 = poor, 4 = excellent).

Results

Reduction rates were significantly lower in the NTG group (P < 0.001), while there were no significant differences in contrast enhancements, SNR, or CNR between groups. Visual evaluation results of the NTG group were significantly better than those of the non-NTG group (P < 0.01).

Conclusion

Abdominal CTA using NTG improved visualization of the abdominal peripheral vessels. This improved arterial view may be beneficial for preoperative evaluation of the arterial anatomy.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Beger HG, Rau B, Gansauge F, Poch B, Link KH (2003) Treatment of pancreatic cancer: challenge of the facts. World J Surg 27:1075–1084CrossRefPubMed Beger HG, Rau B, Gansauge F, Poch B, Link KH (2003) Treatment of pancreatic cancer: challenge of the facts. World J Surg 27:1075–1084CrossRefPubMed
2.
Zurück zum Zitat Fang C, Kong D, Wang X, et al. (2014) Three-dimensional reconstruction of the peripancreatic vascular system based on computed tomographic angiography images and its clinical application in the surgical management of pancreatic tumors. Pancreas 43:389–395CrossRefPubMed Fang C, Kong D, Wang X, et al. (2014) Three-dimensional reconstruction of the peripancreatic vascular system based on computed tomographic angiography images and its clinical application in the surgical management of pancreatic tumors. Pancreas 43:389–395CrossRefPubMed
3.
Zurück zum Zitat Sakaguchi T, Suzuki S, Inaba K, et al. (2012) Peripancreatic arterial anatomy analyzed by 3-dimensional multidetector-row computed tomography. Hepatogastroenterology 59:1986–1989PubMed Sakaguchi T, Suzuki S, Inaba K, et al. (2012) Peripancreatic arterial anatomy analyzed by 3-dimensional multidetector-row computed tomography. Hepatogastroenterology 59:1986–1989PubMed
4.
Zurück zum Zitat Okahara M, Mori H, Kiyosue H, et al. (2010) Arterial supply to the pancreas; variations and cross-sectional anatomy. Abdom Imaging 35:134–142CrossRefPubMed Okahara M, Mori H, Kiyosue H, et al. (2010) Arterial supply to the pancreas; variations and cross-sectional anatomy. Abdom Imaging 35:134–142CrossRefPubMed
5.
Zurück zum Zitat Wong JC, Raman S (2010) Surgical resectability of pancreatic adenocarcinoma: CTA. Abdom Imaging 35:471–480CrossRefPubMed Wong JC, Raman S (2010) Surgical resectability of pancreatic adenocarcinoma: CTA. Abdom Imaging 35:471–480CrossRefPubMed
6.
Zurück zum Zitat Egorov VI, Yashina NI, Fedorov AV, et al. (2010) Celiaco-mesenterial arterial aberrations in patients undergoing extended pancreatic resections: correlation of CT angiography with findings at surgery. JOP 11:348–357PubMed Egorov VI, Yashina NI, Fedorov AV, et al. (2010) Celiaco-mesenterial arterial aberrations in patients undergoing extended pancreatic resections: correlation of CT angiography with findings at surgery. JOP 11:348–357PubMed
7.
Zurück zum Zitat Winston CB, Lee NA, Jarnagin WR, et al. (2007) CT angiography for delineation of celiac and superior mesenteric artery variants in patients undergoing hepatobiliary and pancreatic surgery. AJR Am J Roentgenol 189:W13–W19CrossRefPubMed Winston CB, Lee NA, Jarnagin WR, et al. (2007) CT angiography for delineation of celiac and superior mesenteric artery variants in patients undergoing hepatobiliary and pancreatic surgery. AJR Am J Roentgenol 189:W13–W19CrossRefPubMed
8.
Zurück zum Zitat Brennan DDD, Zamboni GA, Raptopoulos VD, Kruskal JB (2007) Comprehensive preoperative assessment of pancreatic adenocarcinoma with 64-section volumetric CT. Radiographics 27:1653–1666CrossRefPubMed Brennan DDD, Zamboni GA, Raptopoulos VD, Kruskal JB (2007) Comprehensive preoperative assessment of pancreatic adenocarcinoma with 64-section volumetric CT. Radiographics 27:1653–1666CrossRefPubMed
9.
Zurück zum Zitat Horton KM, Fishman EK (2002) Multidetector CT angiography of pancreatic carcinoma: part I, evaluation of arterial involvement. Am J Roentgenol 178:827–831CrossRef Horton KM, Fishman EK (2002) Multidetector CT angiography of pancreatic carcinoma: part I, evaluation of arterial involvement. Am J Roentgenol 178:827–831CrossRef
10.
Zurück zum Zitat Sim JS, Choi BI, Han JK, et al. (1996) Helical CT anatomy of pancreatic arteries. Abdom Imaging 21:517–521CrossRefPubMed Sim JS, Choi BI, Han JK, et al. (1996) Helical CT anatomy of pancreatic arteries. Abdom Imaging 21:517–521CrossRefPubMed
11.
Zurück zum Zitat Marin D, Nelson RC, Barnhart H, et al. (2010) Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique-preliminary results. Radiology 256:450–459CrossRefPubMed Marin D, Nelson RC, Barnhart H, et al. (2010) Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique-preliminary results. Radiology 256:450–459CrossRefPubMed
12.
Zurück zum Zitat Utsunomiya D, Weigold WG, Weissman G, Taylor AJ (2012) Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT. Eur Radiol 22:1287–1294CrossRefPubMed Utsunomiya D, Weigold WG, Weissman G, Taylor AJ (2012) Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT. Eur Radiol 22:1287–1294CrossRefPubMed
13.
Zurück zum Zitat Abbara S, Arbab-Zadeh A, Callister TQ, et al. (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the society of cardiovascular computed tomography guidelines committee. J Cardiovasc Comput Tomogr 3:190–204CrossRefPubMed Abbara S, Arbab-Zadeh A, Callister TQ, et al. (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the society of cardiovascular computed tomography guidelines committee. J Cardiovasc Comput Tomogr 3:190–204CrossRefPubMed
14.
Zurück zum Zitat Klass O, Mutlu S, Hohl K, et al. (2009) Multidetector computed tomography coronary angiography: sublingual nitroglycerine improves image quality significantly because of peripheral coronary vasodilatation. J Comput Assist Tomogr 33:199–203CrossRefPubMed Klass O, Mutlu S, Hohl K, et al. (2009) Multidetector computed tomography coronary angiography: sublingual nitroglycerine improves image quality significantly because of peripheral coronary vasodilatation. J Comput Assist Tomogr 33:199–203CrossRefPubMed
15.
Zurück zum Zitat Chun EJ, Lee W, Choi YH, et al. (2008) Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography. J Comput Assist Tomogr 32:86–92CrossRefPubMed Chun EJ, Lee W, Choi YH, et al. (2008) Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography. J Comput Assist Tomogr 32:86–92CrossRefPubMed
16.
Zurück zum Zitat Decramer I, Vanhoenacker PK, Sarno G, et al. (2008) Effects of sublingual nitroglycerin on coronary lumen diameter and number of visualized septal branches on 64-MDCT angiography. Am J Roentgenol 190:219–225CrossRef Decramer I, Vanhoenacker PK, Sarno G, et al. (2008) Effects of sublingual nitroglycerin on coronary lumen diameter and number of visualized septal branches on 64-MDCT angiography. Am J Roentgenol 190:219–225CrossRef
17.
Zurück zum Zitat Dewey M, Hoffmann H, Hamm B (2006) Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Rofo 178:600–604CrossRefPubMed Dewey M, Hoffmann H, Hamm B (2006) Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Rofo 178:600–604CrossRefPubMed
18.
Zurück zum Zitat Maurer MH, Zimmermann E, Schlattmann P, et al. (2012) Indications, imaging technique, and reading of cardiac computed tomography: survey of clinical practice. Eur Radiol 22:59–72CrossRefPubMed Maurer MH, Zimmermann E, Schlattmann P, et al. (2012) Indications, imaging technique, and reading of cardiac computed tomography: survey of clinical practice. Eur Radiol 22:59–72CrossRefPubMed
19.
Zurück zum Zitat Abrams J (1985) Hemodynamic effects of nitroglycerin and long-acting nitrates. Am Heart J 110:216–224PubMed Abrams J (1985) Hemodynamic effects of nitroglycerin and long-acting nitrates. Am Heart J 110:216–224PubMed
20.
Zurück zum Zitat Apfaltrer P, Hanna EL, Schoepf UJ, et al. (2012) Radiation dose and image quality at high-pitch CT angiography of the aorta: intraindividual and interindividual comparisons with conventional CT angiography. AJR Am J Roentgenol 199:1402–1409CrossRefPubMed Apfaltrer P, Hanna EL, Schoepf UJ, et al. (2012) Radiation dose and image quality at high-pitch CT angiography of the aorta: intraindividual and interindividual comparisons with conventional CT angiography. AJR Am J Roentgenol 199:1402–1409CrossRefPubMed
21.
Zurück zum Zitat Davarpanah AH, Pahade JK, Cornfeld D, et al. (2013) CT angiography in potential living kidney donors: 80 kVp versus 120 kVp. AJR Am J Roentgenol 201:W753–W760CrossRefPubMed Davarpanah AH, Pahade JK, Cornfeld D, et al. (2013) CT angiography in potential living kidney donors: 80 kVp versus 120 kVp. AJR Am J Roentgenol 201:W753–W760CrossRefPubMed
22.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
23.
Zurück zum Zitat Tanikake M, Shimizu T, Narabayashi I, et al. (2003) Three-dimensional CT angiography of the hepatic artery: use of multi-detector row helical CT and a contrast agent. Radiology 227:883–889CrossRefPubMed Tanikake M, Shimizu T, Narabayashi I, et al. (2003) Three-dimensional CT angiography of the hepatic artery: use of multi-detector row helical CT and a contrast agent. Radiology 227:883–889CrossRefPubMed
24.
Zurück zum Zitat Fenchel S, Fleiter TR, Aschoff AJ, et al. (2004) Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas. Br J Radiol 77:821–830CrossRefPubMed Fenchel S, Fleiter TR, Aschoff AJ, et al. (2004) Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas. Br J Radiol 77:821–830CrossRefPubMed
25.
Zurück zum Zitat Shinagawa M, Uchida M, Ishibashi M, Nishimura H, Hayabuchi N (2003) Assessment of pancreatic CT enhancement using a high concentration of contrast material. Radiat Med 21:74–79PubMed Shinagawa M, Uchida M, Ishibashi M, Nishimura H, Hayabuchi N (2003) Assessment of pancreatic CT enhancement using a high concentration of contrast material. Radiat Med 21:74–79PubMed
26.
Zurück zum Zitat Parker JD, Parker JO (1998) Nitrate therapy for stable angina pectoris. N Engl J Med 338:520–531CrossRefPubMed Parker JD, Parker JO (1998) Nitrate therapy for stable angina pectoris. N Engl J Med 338:520–531CrossRefPubMed
27.
Zurück zum Zitat Noonan PK, Benet LZ (1985) Incomplete and delayed bioavailability of sublingual nitroglycerin. Am J Cardiol 55:184–187CrossRefPubMed Noonan PK, Benet LZ (1985) Incomplete and delayed bioavailability of sublingual nitroglycerin. Am J Cardiol 55:184–187CrossRefPubMed
28.
Zurück zum Zitat Raitakari OT, Seale JP, Celermajer DS (2001) Impaired vascular responses to nitroglycerin in subjects with coronary atherosclerosis. Am J Cardiol 87:217–219CrossRefPubMed Raitakari OT, Seale JP, Celermajer DS (2001) Impaired vascular responses to nitroglycerin in subjects with coronary atherosclerosis. Am J Cardiol 87:217–219CrossRefPubMed
29.
Zurück zum Zitat Adams MR, Robinson J, McCredie R, et al. (1998) Smooth muscle dysfunction occurs independently of impaired endothelium-dependent dilation in adults at risk of atherosclerosis. J Am Coll Cardiol 32:123–127CrossRefPubMed Adams MR, Robinson J, McCredie R, et al. (1998) Smooth muscle dysfunction occurs independently of impaired endothelium-dependent dilation in adults at risk of atherosclerosis. J Am Coll Cardiol 32:123–127CrossRefPubMed
30.
Zurück zum Zitat Webb DJ, Freestone S, Allen MJ, Muirhead GJ (1999) Sildenafil citrate and blood-pressure-lowering drugs: results of drug interaction studies with an organic nitrate and a calcium antagonist. Am J Cardiol 83:21C–28CCrossRefPubMed Webb DJ, Freestone S, Allen MJ, Muirhead GJ (1999) Sildenafil citrate and blood-pressure-lowering drugs: results of drug interaction studies with an organic nitrate and a calcium antagonist. Am J Cardiol 83:21C–28CCrossRefPubMed
31.
Zurück zum Zitat Hsi DH, Roshandel A, Singh N, Szombathy T, Meszaros ZS (2005) Headache response to glyceryl trinitrate in patients with and without obstructive coronary artery disease. Heart 91:1164–1166CrossRefPubMedPubMedCentral Hsi DH, Roshandel A, Singh N, Szombathy T, Meszaros ZS (2005) Headache response to glyceryl trinitrate in patients with and without obstructive coronary artery disease. Heart 91:1164–1166CrossRefPubMedPubMedCentral
Metadaten
Titel
Novel contrast-injection protocol for high-resolution abdominal CT-angiography: vascular visualization improvement with vasodilator
verfasst von
Minori Hoshika
Kotaro Yasui
Takefumi Niguma
Toru Kojima
Norimi Nishiyama
Daisuke Suzuki
Izumi Togami
Publikationsdatum
09.05.2017
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 10/2017
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-017-1163-y

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.