Skip to main content
Erschienen in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie 12/2022

05.10.2022 | Case Reports / Case Series

Novel use of transesophageal echocardiography to optimize hemodynamics and patient positioning during prone scoliosis surgery and safety considerations in the setting of intraoperative neuromonitoring: a case report

verfasst von: Kim Phan, BSc, Adele Budiansky, MD, Elizabeth Miller, MD, Philippe Phan, MD, Daniel Dubois, MD

Erschienen in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie | Ausgabe 12/2022

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The prone position can lead to anatomical compression of the thoracic cavity resulting in reduced cardiac output, especially in the context of chest wall deformities commonly present in patients with scoliosis. There are no protocols for using transesophageal echocardiography (TEE) to optimize prone positioning and for safe use of TEE during cases requiring neuromonitoring.

Clinical features

We present a case of a 23-yr-old male with Cornelia de Lange syndrome undergoing elective posterior spinal fusion for syndromic scoliosis who developed severe refractory hypotension and cardiac arrest in the prone position. After hemodynamic stabilization in the intensive care unit, the patient returned to the operating room on postoperative day 2 for completion of his spinal fusion. Transesophageal echocardiography determined the optimal position of longitudinal bolster placements associated with minimal left ventricular compression in the supine position. The patient was then proned and intraoperative hemodynamics during the second surgery remained stable. Owing to the special considerations of using TEE in the prone position with neuromonitoring, we describe technical aspects to consider to protect the equipment and patient.

Conclusion

Patients with compliant chest walls or thoracic deformities are at risk of hemodynamic instability in the prone position. Intraoperative TEE can be used in the supine patient prior to proning to determine optimal longitudinal bolster positioning to minimize cardiac compression. Transesophageal echocardiography used during spine surgery in the prone position with neuromonitoring and motor-evoked potentials requires special considerations for patient safety.
Literatur
Metadaten
Titel
Novel use of transesophageal echocardiography to optimize hemodynamics and patient positioning during prone scoliosis surgery and safety considerations in the setting of intraoperative neuromonitoring: a case report
verfasst von
Kim Phan, BSc
Adele Budiansky, MD
Elizabeth Miller, MD
Philippe Phan, MD
Daniel Dubois, MD
Publikationsdatum
05.10.2022
Verlag
Springer International Publishing
Erschienen in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Ausgabe 12/2022
Print ISSN: 0832-610X
Elektronische ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-022-02334-w

Weitere Artikel der Ausgabe 12/2022

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 12/2022 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.