Skip to main content
Erschienen in: Journal of Digital Imaging 5/2011

01.10.2011

Occlusal Caries Depth Measurements Obtained by Five Different Imaging Modalities

verfasst von: Kıvanç Kamburoğlu, Hakan Kurt, Eray Kolsuz, Bengi Öztaş, İlkan Tatar, Hakan Hamdi Çelik

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 5/2011

Einloggen, um Zugang zu erhalten

Abstract

The study aimed to assess the accuracy and reproducibility of occlusal caries depth measurements obtained from different imaging modalities. The study comprised 21 human mandibular molar teeth with occlusal caries. Teeth were imaged using film, CCD, two different cone-beam computerized tomography (CBCT) units and a microcomputer tomography (micro-CT). Thereafter, each tooth was serially sectioned, and the section with the deepest carious lesion was scanned using a high-resolution scanner. Each image set was separately viewed by three oral radiologists. Images were viewed randomly, and each set was viewed twice. Lesion depth was measured on film images using a digital caliper, on CCD and CBCT images using built-in measurement tools, on micro-CT images using the Mimics software program, and on histological images using AxioVision Rel. 4.7. Intra- and inter-rater reliabilities were assessed according to the Bland/Altman method by calculating Intraclass Correlation Coefficients (ICCs). Mean/median values obtained with intraoral systems were lower than those obtained with 3-D and histological images for all observers and both readings. Intra-observer ICC values for all observers were highest for histology and micro-CT. In addition, intra-observer ICC values were higher for histology and CBCT than for histology and intra-oral methods. Inter-observer ICC values for first and second readings were high for all observers. No differences in repeatability were found between Accuitomo and Iluma CBCT images or between intra-oral film and CCD images. Micro-CT was found to be the best imaging method for the ex vivo measurement of occlusal caries depth. In addition, both CBCT units performed similarly and better than intra-oral modalities.
Literatur
1.
Zurück zum Zitat Poorterman JHG, Weerheijm KL, Groen HJ, Kalsbeek H: Clinical and radiographic judgment of occlusal caries in adolescents. Eur J Oral Sci 108:93–98, 2000PubMedCrossRef Poorterman JHG, Weerheijm KL, Groen HJ, Kalsbeek H: Clinical and radiographic judgment of occlusal caries in adolescents. Eur J Oral Sci 108:93–98, 2000PubMedCrossRef
2.
Zurück zum Zitat Dowker SEP, Elliott JC, Davis GR, Wilson RM, Cloetens P: Three-dimensional study of human dental fissure enamel by synchrotron X-ray microtomography. Eur J Oral Sci 114(Suppl. 1):353–359, 2006PubMedCrossRef Dowker SEP, Elliott JC, Davis GR, Wilson RM, Cloetens P: Three-dimensional study of human dental fissure enamel by synchrotron X-ray microtomography. Eur J Oral Sci 114(Suppl. 1):353–359, 2006PubMedCrossRef
3.
Zurück zum Zitat Shi XQ, Welander U, Angmar-Mansson B: Occlusal caries detection with KaVo DIAGNOdent and radiography: an in vitro comparison. Caries Res 34:151–158, 2000PubMedCrossRef Shi XQ, Welander U, Angmar-Mansson B: Occlusal caries detection with KaVo DIAGNOdent and radiography: an in vitro comparison. Caries Res 34:151–158, 2000PubMedCrossRef
4.
Zurück zum Zitat Kühnisch J, Dietz W, Stösser L, Hickel R, Heinrich-Weltzien R: Effects of dental probing on occlusal surfaces—a scanning electron microscopy evaluation. Caries Res 41:43–48, 2007PubMedCrossRef Kühnisch J, Dietz W, Stösser L, Hickel R, Heinrich-Weltzien R: Effects of dental probing on occlusal surfaces—a scanning electron microscopy evaluation. Caries Res 41:43–48, 2007PubMedCrossRef
5.
Zurück zum Zitat Souza-Zaroni WC, Ciccone JC, Souza-Gabriel AE, Ramos RP, Corona SAM, Palma-Dibb RG: Validity and reproducibility of different combinations of methods for occlusal caries detection: an in vitro comparison. Caries Res 40:194–201, 2006PubMedCrossRef Souza-Zaroni WC, Ciccone JC, Souza-Gabriel AE, Ramos RP, Corona SAM, Palma-Dibb RG: Validity and reproducibility of different combinations of methods for occlusal caries detection: an in vitro comparison. Caries Res 40:194–201, 2006PubMedCrossRef
6.
Zurück zum Zitat Hamilton JC, Gregory WA, Valentine JB: DIAGNOdent measurements and correlation with the depth and volume of minimally invasive cavity preparations. Oper Dent 31:291–296, 2006PubMedCrossRef Hamilton JC, Gregory WA, Valentine JB: DIAGNOdent measurements and correlation with the depth and volume of minimally invasive cavity preparations. Oper Dent 31:291–296, 2006PubMedCrossRef
7.
Zurück zum Zitat Jablonski-Momeni A, Stachniss V, Ricketts DN, Heinzel-Gutenbrunner M, Pieper K: Reproducibility and accuracy of the ICDAS-II for detection of occlusal caries in vitro. Caries Res 42:79–87, 2008PubMedCrossRef Jablonski-Momeni A, Stachniss V, Ricketts DN, Heinzel-Gutenbrunner M, Pieper K: Reproducibility and accuracy of the ICDAS-II for detection of occlusal caries in vitro. Caries Res 42:79–87, 2008PubMedCrossRef
8.
Zurück zum Zitat Rodrigues JA, Hug I, Diniz MB, Lussi A: Performance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro. Caries Res 42:297–304, 2008PubMedCrossRef Rodrigues JA, Hug I, Diniz MB, Lussi A: Performance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro. Caries Res 42:297–304, 2008PubMedCrossRef
9.
Zurück zum Zitat Abalos C, Herrera M, Jimenez-Planas A, Llamas R: Performance of laser fluorescence for detection of occlusal dentinal caries lesions in permanent molars: an in vivo study with total validation of the sample. Caries Res 43:137–141, 2009PubMedCrossRef Abalos C, Herrera M, Jimenez-Planas A, Llamas R: Performance of laser fluorescence for detection of occlusal dentinal caries lesions in permanent molars: an in vivo study with total validation of the sample. Caries Res 43:137–141, 2009PubMedCrossRef
10.
Zurück zum Zitat Hintze H, Wenzel A: Clinical and laboratory radiographic caries diagnosis. A study same teeth. Dentomaxillofac Radiol 25:115–118, 1996PubMed Hintze H, Wenzel A: Clinical and laboratory radiographic caries diagnosis. A study same teeth. Dentomaxillofac Radiol 25:115–118, 1996PubMed
11.
Zurück zum Zitat Kositbowornchai S, Basiw M, Promwang Y, Moragorn H, Sooksuntisakoonchai N: Accuracy of diagnosing occlusal caries using enhanced digital images. Dentomaxillofac Radiol 33:236–240, 2004PubMedCrossRef Kositbowornchai S, Basiw M, Promwang Y, Moragorn H, Sooksuntisakoonchai N: Accuracy of diagnosing occlusal caries using enhanced digital images. Dentomaxillofac Radiol 33:236–240, 2004PubMedCrossRef
12.
Zurück zum Zitat Ricketts DNJ, Ekstrand KR, Martignon S, Ellwood R, Alatsaris M, Nugent Z: Accuracy and reproducibility of conventional radiographic assessment and subtraction radiography in detecting demineralization in occlusal surfaces. Caries Res 41:121–128, 2007PubMedCrossRef Ricketts DNJ, Ekstrand KR, Martignon S, Ellwood R, Alatsaris M, Nugent Z: Accuracy and reproducibility of conventional radiographic assessment and subtraction radiography in detecting demineralization in occlusal surfaces. Caries Res 41:121–128, 2007PubMedCrossRef
13.
Zurück zum Zitat Pereira AC, Eggertsson H, Martinez-Mier EA, Mialhe FL, Eckert GJ, Zero DT: Validity of caries detection on occlusal surfaces and treatment decisions based on results from multiple caries-detection methods. Eur J Oral Sci 117:51–57, 2009PubMedCrossRef Pereira AC, Eggertsson H, Martinez-Mier EA, Mialhe FL, Eckert GJ, Zero DT: Validity of caries detection on occlusal surfaces and treatment decisions based on results from multiple caries-detection methods. Eur J Oral Sci 117:51–57, 2009PubMedCrossRef
14.
Zurück zum Zitat Kühnisch J, Ifland S, Tranaeus S, Heinrich-Weltzien R: Comparison of visual inspection and different radiographic methods for dentin caries detection on occlusal surfaces. Dentomaxillofac Radiol 38:452–457, 2009PubMedCrossRef Kühnisch J, Ifland S, Tranaeus S, Heinrich-Weltzien R: Comparison of visual inspection and different radiographic methods for dentin caries detection on occlusal surfaces. Dentomaxillofac Radiol 38:452–457, 2009PubMedCrossRef
15.
Zurück zum Zitat Kamburoğlu K, Şenel B, Yüksel SP, Özen T: A comparison of the diagnostic accuracy of in vivo and in vitro photostimulable phosphor digital images in the detection of occlusal caries lesions. Dentomaxillofac Radiol 39:17–22, 2010PubMedCrossRef Kamburoğlu K, Şenel B, Yüksel SP, Özen T: A comparison of the diagnostic accuracy of in vivo and in vitro photostimulable phosphor digital images in the detection of occlusal caries lesions. Dentomaxillofac Radiol 39:17–22, 2010PubMedCrossRef
16.
Zurück zum Zitat Scarfe WC, Farman AG: What is cone-beam CT and how does it work? Dent Clin North Am 52:707–730, 2008PubMedCrossRef Scarfe WC, Farman AG: What is cone-beam CT and how does it work? Dent Clin North Am 52:707–730, 2008PubMedCrossRef
17.
Zurück zum Zitat Tyndall DA, Rathore S: Cone-beam CT diagnostic applications: caries, periodontal bone assessment, and endodontic applications. Dent Clin North Am 52:825–841, 2008PubMedCrossRef Tyndall DA, Rathore S: Cone-beam CT diagnostic applications: caries, periodontal bone assessment, and endodontic applications. Dent Clin North Am 52:825–841, 2008PubMedCrossRef
18.
Zurück zum Zitat Akdeniz BG, Gröndahl HG, Magnusson B: Accuracy of proximal caries depth measurements: comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res 40:202–207, 2006PubMedCrossRef Akdeniz BG, Gröndahl HG, Magnusson B: Accuracy of proximal caries depth measurements: comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res 40:202–207, 2006PubMedCrossRef
19.
Zurück zum Zitat Kamburoğlu K, Murat S, Yüksel SP, Cebeci ARİ, Paksoy CS: Occlusal caries detection by using a cone-beam CT with different voxel resolutions and a digital intraoral sensor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109:e63–e69, 2010PubMedCrossRef Kamburoğlu K, Murat S, Yüksel SP, Cebeci ARİ, Paksoy CS: Occlusal caries detection by using a cone-beam CT with different voxel resolutions and a digital intraoral sensor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109:e63–e69, 2010PubMedCrossRef
20.
Zurück zum Zitat Haiter-Neto F, Wenzel A, Gotfredsen E: Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 37:18–22, 2008PubMedCrossRef Haiter-Neto F, Wenzel A, Gotfredsen E: Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 37:18–22, 2008PubMedCrossRef
21.
Zurück zum Zitat Young SM, Lee JT, Hodges RJ, Chang TL, Elashoff DA, White SC: A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries. Dentomaxillofac Radiol 38:445–451, 2009PubMedCrossRef Young SM, Lee JT, Hodges RJ, Chang TL, Elashoff DA, White SC: A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries. Dentomaxillofac Radiol 38:445–451, 2009PubMedCrossRef
22.
Zurück zum Zitat Jablonski-Momeni A, Ricketts DNJ, Stachniss V, Maschka R, Heinzel-Gutenbrunner M, Pieper K: Occlusal caries: evaluation of direct microscopy versus digital imaging used for two histological classification systems. J Dent 37:204–211, 2009PubMedCrossRef Jablonski-Momeni A, Ricketts DNJ, Stachniss V, Maschka R, Heinzel-Gutenbrunner M, Pieper K: Occlusal caries: evaluation of direct microscopy versus digital imaging used for two histological classification systems. J Dent 37:204–211, 2009PubMedCrossRef
23.
Zurück zum Zitat Schwass DR, Swain MV, Purton DG, Leichter JW: A system of calibrating microtomography for use in caries research. Caries Res 43:314–321, 2009PubMedCrossRef Schwass DR, Swain MV, Purton DG, Leichter JW: A system of calibrating microtomography for use in caries research. Caries Res 43:314–321, 2009PubMedCrossRef
24.
Zurück zum Zitat Kamburoğlu K, Barenboim SF, Arıtürk T, Kaffe I: Quantitative measurements obtained by micro-computed tomography and confocal laser scanning microscopy. Dentomaxillofac Radiol 37:385–391, 2008PubMedCrossRef Kamburoğlu K, Barenboim SF, Arıtürk T, Kaffe I: Quantitative measurements obtained by micro-computed tomography and confocal laser scanning microscopy. Dentomaxillofac Radiol 37:385–391, 2008PubMedCrossRef
25.
Zurück zum Zitat Neves Ade A, Coutinho E, Cardoso MV, Jaecques SV, Van Meerbeek B: Micro- CT based quantitative evaluation of caries excavation. Dent Mater 26:579–588, 2010PubMedCrossRef Neves Ade A, Coutinho E, Cardoso MV, Jaecques SV, Van Meerbeek B: Micro- CT based quantitative evaluation of caries excavation. Dent Mater 26:579–588, 2010PubMedCrossRef
26.
Zurück zum Zitat Spiguel MH, Tovo MF, Kramer PF, Franco KS, Alves KMPR, Delbem ACB: Evaluation of laser fluorescence in the monitoring of the initial stage of the de-/remineralization process: an in vitro and in situ study. Caries Res 43:302–307, 2009PubMedCrossRef Spiguel MH, Tovo MF, Kramer PF, Franco KS, Alves KMPR, Delbem ACB: Evaluation of laser fluorescence in the monitoring of the initial stage of the de-/remineralization process: an in vitro and in situ study. Caries Res 43:302–307, 2009PubMedCrossRef
27.
Zurück zum Zitat Kühnisch J, Heinrich-Weltzien R, Tabatabaie M, Stösser L, Huysmans MCDNJM: An in vitro comparison between two methods of electrical resistance measurement for occlusal caries detection. Caries Res 40:104–111, 2006PubMedCrossRef Kühnisch J, Heinrich-Weltzien R, Tabatabaie M, Stösser L, Huysmans MCDNJM: An in vitro comparison between two methods of electrical resistance measurement for occlusal caries detection. Caries Res 40:104–111, 2006PubMedCrossRef
28.
Zurück zum Zitat Verdonschot EH, Wenzel A, Truin GJ, König KG: Performance of electrical resistance measurements adjunct visual inspection in the early diagnosis of occlusal caries. J Dent 21:332–337, 1993PubMedCrossRef Verdonschot EH, Wenzel A, Truin GJ, König KG: Performance of electrical resistance measurements adjunct visual inspection in the early diagnosis of occlusal caries. J Dent 21:332–337, 1993PubMedCrossRef
29.
Zurück zum Zitat Zakian CM, Taylor AM, Ellwood RP, Pretty IA: Occlusal caries detection by using thermal imaging. J Dent 38:788–795, 2010PubMedCrossRef Zakian CM, Taylor AM, Ellwood RP, Pretty IA: Occlusal caries detection by using thermal imaging. J Dent 38:788–795, 2010PubMedCrossRef
30.
Zurück zum Zitat Lofthag-Hansen S, Thilander-Klang A, Ekestubbe A, Helmrot E, Gröndahl K: Calculating effective dose on a cone beam computed tomography device: 3D Accuitomo and 3D Accuitomo FPD. Dentomaxillofac Radiol 37:72–79, 2008PubMedCrossRef Lofthag-Hansen S, Thilander-Klang A, Ekestubbe A, Helmrot E, Gröndahl K: Calculating effective dose on a cone beam computed tomography device: 3D Accuitomo and 3D Accuitomo FPD. Dentomaxillofac Radiol 37:72–79, 2008PubMedCrossRef
31.
Zurück zum Zitat Ludlow JB, Ivanovic M: Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:106–114, 2008PubMedCrossRef Ludlow JB, Ivanovic M: Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:106–114, 2008PubMedCrossRef
Metadaten
Titel
Occlusal Caries Depth Measurements Obtained by Five Different Imaging Modalities
verfasst von
Kıvanç Kamburoğlu
Hakan Kurt
Eray Kolsuz
Bengi Öztaş
İlkan Tatar
Hakan Hamdi Çelik
Publikationsdatum
01.10.2011
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 5/2011
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-010-9355-9

Weitere Artikel der Ausgabe 5/2011

Journal of Digital Imaging 5/2011 Zur Ausgabe

Update Radiologie