Skip to main content
Erschienen in: International Ophthalmology 3/2017

12.08.2016 | Original Paper

Opaque bubble layer incidence in Femtosecond laser-assisted LASIK: comparison among different flap design parameters

verfasst von: Leonardo Mastropasqua, Roberta Calienno, Manuela Lanzini, Niccolò Salgari, Sergio De Vecchi, Rodolfo Mastropasqua, Mario Nubile

Erschienen in: International Ophthalmology | Ausgabe 3/2017

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate the incidence of opaque bubble layer (OBL) in femtosecond laser-assisted in situ keratomileusis (LASIK) flaps created with the support of Visumax Carl Zeiss femtosecond laser, planned with different flap diameters (7.90, 8.0, and 8.20 mm) and the same laser energy and power settings. Incidence of intraoperative OBL in flaps of consecutive 108 patients (216 eyes) subjected to bilateral femtosecond-assisted LASIK was considered. Flap creation was performed with the same laser design parameters (spot distance and energy offset) and different presetting diameters of 7.90 mm (72 eyes, group 1), 8 mm (72 eyes, group 2), and 8.20 mm (72 eyes, group 3). The incidence of OBL was considered and its extension was reported measuring involvement of different four corneal flap quadrants in which was theoretically divided the entire flap area; based on these data, OBL presence was classified as none (no evidence of OBL), minimal (minimal presence in not more that one quadrants corneal flap), mild (OBL presence in almost two or three quadrants without tendency to invade central cornea), and moderate (OBL presence in almost three quadrants with tendency to invade central cornea). In group 1, the incidence of OBL was of 23.6 % (17 eyes) with a mild/moderate presence; in group 2, incidence was 20.8 % (15 eyes) with mild presence. Group 3 presented a reduced OBL incidence (4.1 %, 3 eye) with a minimal presence. No statistically significant difference was found between group 1 and 2 (p = 0.8414).We found statistically significant differences between group 1 and group 3 (p = 0.0012) and between groups 2 and 3 (p = 0.0044). A significant reduction and extension of OBL incidence were evident when LASIK flap settings diameter was increased, and flap edge was closer to the contact glass border; this is probably consequent to a more effective gas dispersion outside of corneal flap.
Literatur
1.
Zurück zum Zitat Aristeidou A, Taniguchi EV, Tsatsos M, Muller R, McAlinden C, Pineda R, Paschalis EI (2015) The evolution of corneal and refractive surgery with the femtosecond laser. Eye Vis 2:12CrossRef Aristeidou A, Taniguchi EV, Tsatsos M, Muller R, McAlinden C, Pineda R, Paschalis EI (2015) The evolution of corneal and refractive surgery with the femtosecond laser. Eye Vis 2:12CrossRef
2.
Zurück zum Zitat Stern D, Schoenlein RW, Puliafito CA, Dobi ET, Birngruber R, Fujimoto JG (1989) Corneal ablation by nanosecond, picosecond, and femtosecond lasers at 532 and 625 nm. Arch Ophthalmol 107(4):587–592CrossRefPubMed Stern D, Schoenlein RW, Puliafito CA, Dobi ET, Birngruber R, Fujimoto JG (1989) Corneal ablation by nanosecond, picosecond, and femtosecond lasers at 532 and 625 nm. Arch Ophthalmol 107(4):587–592CrossRefPubMed
3.
Zurück zum Zitat Ratkay-Traub I, Ferincz IE, Juhasz T, Kurtz RM, Krueger RR (2003) First clinical results with the femtosecond neodymium-glass laser in refractive surgery. J Refract Surg 19:94–103PubMed Ratkay-Traub I, Ferincz IE, Juhasz T, Kurtz RM, Krueger RR (2003) First clinical results with the femtosecond neodymium-glass laser in refractive surgery. J Refract Surg 19:94–103PubMed
4.
5.
Zurück zum Zitat Ratkay-Traub I, Juhasz T, Horvath C et al (2001) Ultra-short pulse (femtosecond) laser surgery: initial use in LASIK flap creation. Ophthalmol Clin North Am 14(2):347–355PubMed Ratkay-Traub I, Juhasz T, Horvath C et al (2001) Ultra-short pulse (femtosecond) laser surgery: initial use in LASIK flap creation. Ophthalmol Clin North Am 14(2):347–355PubMed
6.
Zurück zum Zitat Binder PS (2010) Femtosecond applications for anterior segment surgery. Eye Contact Lens 36(5):282–285CrossRefPubMed Binder PS (2010) Femtosecond applications for anterior segment surgery. Eye Contact Lens 36(5):282–285CrossRefPubMed
7.
Zurück zum Zitat Sugar A, Rapuano CJ, Culbertson WW, Huang D, Varley GA, Agapitos PJ, de Luise VP, Koch DD (2002) Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy: a report by the American Academy of Ophthalmology. Ophthalmology 109(1):175–187CrossRefPubMed Sugar A, Rapuano CJ, Culbertson WW, Huang D, Varley GA, Agapitos PJ, de Luise VP, Koch DD (2002) Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy: a report by the American Academy of Ophthalmology. Ophthalmology 109(1):175–187CrossRefPubMed
8.
Zurück zum Zitat Slade SG (2007) The use of the femtosecond laser in the customization of corneal flaps in laser in situ keratomileusis. Curr Opin Ophthalmol 18(4):314–317CrossRefPubMed Slade SG (2007) The use of the femtosecond laser in the customization of corneal flaps in laser in situ keratomileusis. Curr Opin Ophthalmol 18(4):314–317CrossRefPubMed
10.
Zurück zum Zitat Morshirfar M, Gardiner JP, Schliesser JA, Espandar L, Feiz V, Mifflin MD et al (2010) Laser in situ keratomileusis flap complications using mechanical microkeratome versus femtosecond laser: retrospective comparison. J Cataract Refract Surg 36:1925–1933CrossRef Morshirfar M, Gardiner JP, Schliesser JA, Espandar L, Feiz V, Mifflin MD et al (2010) Laser in situ keratomileusis flap complications using mechanical microkeratome versus femtosecond laser: retrospective comparison. J Cataract Refract Surg 36:1925–1933CrossRef
11.
Zurück zum Zitat Liu CH, Sun CC, Hui-Kang Ma D, Chien-Chieh Huang J, Liu CF, Chen HF, Hsiao CH (2014) Opaque bubble layer: incidence, risk factors, and clinical relevance. J Cataract Refract Surg 40(3):435–440CrossRefPubMed Liu CH, Sun CC, Hui-Kang Ma D, Chien-Chieh Huang J, Liu CF, Chen HF, Hsiao CH (2014) Opaque bubble layer: incidence, risk factors, and clinical relevance. J Cataract Refract Surg 40(3):435–440CrossRefPubMed
12.
Zurück zum Zitat Courtin R, Saad A, Guilbert E, Grise-Dulac A, Gatinel D (2015) Opaque bubble layer risk factors in femtosecond laser-assisted LASIK. J Refract Surg 31(9):608–612CrossRefPubMed Courtin R, Saad A, Guilbert E, Grise-Dulac A, Gatinel D (2015) Opaque bubble layer risk factors in femtosecond laser-assisted LASIK. J Refract Surg 31(9):608–612CrossRefPubMed
13.
Zurück zum Zitat Jung HG, Kim J, Lim TH (2015) Possible risk factors and clinical effects of an opaque bubble layer created with femtosecond laser-assisted laser in situ keratomileusis. J Cataract Refract Surg 41(7):1393–1399CrossRefPubMed Jung HG, Kim J, Lim TH (2015) Possible risk factors and clinical effects of an opaque bubble layer created with femtosecond laser-assisted laser in situ keratomileusis. J Cataract Refract Surg 41(7):1393–1399CrossRefPubMed
14.
Zurück zum Zitat Kaiserman I, Maresky HS, Bahar I, Rootman DS (2008) Incidence, possible risk factors, and potential effects of an opaque bubble layer created by a femtosecond laser. J Cataract Refract Surg 34:417–423CrossRefPubMed Kaiserman I, Maresky HS, Bahar I, Rootman DS (2008) Incidence, possible risk factors, and potential effects of an opaque bubble layer created by a femtosecond laser. J Cataract Refract Surg 34:417–423CrossRefPubMed
15.
Zurück zum Zitat Kanellopoulos AJ, Asimellis G (2013) Essential opaque bubble layer elimination with novel LASIK flap settings in the FS200 Femtosecond Laser. Clin Ophthalmol 7:765–770CrossRefPubMedPubMedCentral Kanellopoulos AJ, Asimellis G (2013) Essential opaque bubble layer elimination with novel LASIK flap settings in the FS200 Femtosecond Laser. Clin Ophthalmol 7:765–770CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Santhiago MR, Wilson SE (2012) Cellular effects after laser in situ keratomileusis flap formation with femtosecond lasers: a review. Cornea 31(2):198–205CrossRefPubMed Santhiago MR, Wilson SE (2012) Cellular effects after laser in situ keratomileusis flap formation with femtosecond lasers: a review. Cornea 31(2):198–205CrossRefPubMed
Metadaten
Titel
Opaque bubble layer incidence in Femtosecond laser-assisted LASIK: comparison among different flap design parameters
verfasst von
Leonardo Mastropasqua
Roberta Calienno
Manuela Lanzini
Niccolò Salgari
Sergio De Vecchi
Rodolfo Mastropasqua
Mario Nubile
Publikationsdatum
12.08.2016
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 3/2017
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-016-0323-3

Weitere Artikel der Ausgabe 3/2017

International Ophthalmology 3/2017 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.