Skip to main content
Erschienen in: Journal of Digital Imaging 4/2016

07.12.2015

Open-Source Radiation Exposure Extraction Engine (RE3) with Patient-Specific Outlier Detection

verfasst von: Samuel J. Weisenthal, Les Folio, William Kovacs, Ari Seff, Vana Derderian, Ronald M. Summers, Jianhua Yao

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

We present an open-source, picture archiving and communication system (PACS)-integrated radiation exposure extraction engine (RE3) that provides study-, series-, and slice-specific data for automated monitoring of computed tomography (CT) radiation exposure. RE3 was built using open-source components and seamlessly integrates with the PACS. RE3 calculations of dose length product (DLP) from the Digital imaging and communications in medicine (DICOM) headers showed high agreement (R 2 = 0.99) with the vendor dose pages. For study-specific outlier detection, RE3 constructs robust, automatically updating multivariable regression models to predict DLP in the context of patient gender and age, scan length, water-equivalent diameter (D w), and scanned body volume (SBV). As proof of concept, the model was trained on 811 CT chest, abdomen + pelvis (CAP) exams and 29 outliers were detected. The continuous variables used in the outlier detection model were scan length (R 2  = 0.45), D w (R 2 = 0.70), SBV (R 2 = 0.80), and age (R 2 = 0.01). The categorical variables were gender (male average 1182.7 ± 26.3 and female 1047.1 ± 26.9 mGy cm) and pediatric status (pediatric average 710.7 ± 73.6 mGy cm and adult 1134.5 ± 19.3 mGy cm).
Literatur
1.
Zurück zum Zitat Mayo JR, Aldrich J, Müller NL: Radiation exposure at chest CT: a statement of the Fleischner Society 1. Radiology 228(1):15–21, 2003CrossRefPubMed Mayo JR, Aldrich J, Müller NL: Radiation exposure at chest CT: a statement of the Fleischner Society 1. Radiology 228(1):15–21, 2003CrossRefPubMed
2.
Zurück zum Zitat Brenner DJ, Hall EJ: Computed tomography—an increasing source of radiation exposure. N Engl J Med 357(22):2277–2284, 2007CrossRefPubMed Brenner DJ, Hall EJ: Computed tomography—an increasing source of radiation exposure. N Engl J Med 357(22):2277–2284, 2007CrossRefPubMed
3.
Zurück zum Zitat Smith-Bindman R, Lipson J, Marcus R, et al: Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169(22):2078–2086, 2009CrossRefPubMedPubMedCentral Smith-Bindman R, Lipson J, Marcus R, et al: Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169(22):2078–2086, 2009CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat de González AB, Darby S: Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet 363(9406):345–351, 2004CrossRef de González AB, Darby S: Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet 363(9406):345–351, 2004CrossRef
5.
Zurück zum Zitat Shuryak I, Hahnfeldt P, Hlatky L, et al: A new view of radiation-induced cancer: integrating short-and long-term processes. Part I: approach. Radiat Environ Biophys 48(3):263–274, 2009CrossRefPubMedPubMedCentral Shuryak I, Hahnfeldt P, Hlatky L, et al: A new view of radiation-induced cancer: integrating short-and long-term processes. Part I: approach. Radiat Environ Biophys 48(3):263–274, 2009CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Pearce MS, Salotti JA, Little MP, et al: Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380(9840):499–505, 2012CrossRefPubMedPubMedCentral Pearce MS, Salotti JA, Little MP, et al: Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380(9840):499–505, 2012CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Dijkstra H, Groen JM, Bongaerts FA, et al: The cumulative risk of multiple CT exposures using two different methods. Health Phys 106(4):475–483, 2014CrossRefPubMed Dijkstra H, Groen JM, Bongaerts FA, et al: The cumulative risk of multiple CT exposures using two different methods. Health Phys 106(4):475–483, 2014CrossRefPubMed
9.
Zurück zum Zitat Shore RE: Radiation impacts on human health: certain, fuzzy, and unknown. Health Phys 106(2):196–205, 2014CrossRefPubMed Shore RE: Radiation impacts on human health: certain, fuzzy, and unknown. Health Phys 106(2):196–205, 2014CrossRefPubMed
10.
Zurück zum Zitat Lin Z: Cancer risk from low dose radiation depends directly on the organ mass in a general model of radiation-induced cancer risk. Health Phys 106(4):459–465, 2014CrossRefPubMed Lin Z: Cancer risk from low dose radiation depends directly on the organ mass in a general model of radiation-induced cancer risk. Health Phys 106(4):459–465, 2014CrossRefPubMed
11.
Zurück zum Zitat Sodickson A, Baeyens PF, Andriole KP, et al: Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults 1. Radiology 251(1):175–184, 2009CrossRefPubMed Sodickson A, Baeyens PF, Andriole KP, et al: Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults 1. Radiology 251(1):175–184, 2009CrossRefPubMed
12.
Zurück zum Zitat Brenner DJ, Doll R, Goodhead DT, et al: Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci 100(24):13761–13766, 2003CrossRefPubMedPubMedCentral Brenner DJ, Doll R, Goodhead DT, et al: Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci 100(24):13761–13766, 2003CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat California Senate Bill 1237, S. 115111, 115112, and 115113 California Health and Safety Code, 2010 California Senate Bill 1237, S. 115111, 115112, and 115113 California Health and Safety Code, 2010
15.
Zurück zum Zitat Lukasiewicz A, Bhargavan-Chatfield M, Coombs L, et al: Radiation dose index of renal colic protocol CT studies in the United States: a report from the American College of Radiology National Radiology Data Registry. Radiology 271(2):445–451, 2014CrossRefPubMed Lukasiewicz A, Bhargavan-Chatfield M, Coombs L, et al: Radiation dose index of renal colic protocol CT studies in the United States: a report from the American College of Radiology National Radiology Data Registry. Radiology 271(2):445–451, 2014CrossRefPubMed
16.
Zurück zum Zitat Rehani MM: Challenges in radiation protection of patients for the 21st century. Am J Roentgenol 200(4):762–764, 2013CrossRef Rehani MM: Challenges in radiation protection of patients for the 21st century. Am J Roentgenol 200(4):762–764, 2013CrossRef
18.
Zurück zum Zitat Seetharam Chadalavada M, Anand Sundaram MS, Woojin Kim MD, William W. Boonn MD, Tessa Cook MD: A RADIANCE-based alerting system for CT radiation dose estimates society for imaging informatics in medicine 2012 scientific session. Orlando, 2012 Seetharam Chadalavada M, Anand Sundaram MS, Woojin Kim MD, William W. Boonn MD, Tessa Cook MD: A RADIANCE-based alerting system for CT radiation dose estimates society for imaging informatics in medicine 2012 scientific session. Orlando, 2012
19.
Zurück zum Zitat Smith-Bindman R, Moghadassi M, Wilson N, Nelson TR, Boone JM, Cagnon CH, et al: Radiation doses in consecutive CT examinations from five University of California Medical Centers. Radiology 142728, 2015 Smith-Bindman R, Moghadassi M, Wilson N, Nelson TR, Boone JM, Cagnon CH, et al: Radiation doses in consecutive CT examinations from five University of California Medical Centers. Radiology 142728, 2015
20.
Zurück zum Zitat Mueller JW, Vining DJ, Jones AK, et al: JOURNAL CLUB: In vivo CT dosimetry during CT colonography. Am J Roentgenol 202(4):703–710, 2014CrossRef Mueller JW, Vining DJ, Jones AK, et al: JOURNAL CLUB: In vivo CT dosimetry during CT colonography. Am J Roentgenol 202(4):703–710, 2014CrossRef
21.
Zurück zum Zitat Cook TS, Zimmerman SL, Steingall SR, et al: Informatics in radiology: RADIANCE: an automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates. Radiographics 31(7):1833–1846, 2011CrossRefPubMed Cook TS, Zimmerman SL, Steingall SR, et al: Informatics in radiology: RADIANCE: an automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates. Radiographics 31(7):1833–1846, 2011CrossRefPubMed
22.
Zurück zum Zitat Sodickson A, Warden GI, Farkas CE, et al: Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring. Radiology 264(2):397–405, 2012CrossRefPubMedPubMedCentral Sodickson A, Warden GI, Farkas CE, et al: Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring. Radiology 264(2):397–405, 2012CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Talati RK, Dunkin J, Parikh S, et al: Current methods of monitoring radiation exposure from CT. J Am Coll Radiol 10(9):702–707, 2013CrossRefPubMed Talati RK, Dunkin J, Parikh S, et al: Current methods of monitoring radiation exposure from CT. J Am Coll Radiol 10(9):702–707, 2013CrossRefPubMed
25.
Zurück zum Zitat Nicholson R, Fetherston S: Primary radiation outside the imaged volume of a multislice helical CT scan. Br J Radiol 75(894):518–522, 2002CrossRefPubMed Nicholson R, Fetherston S: Primary radiation outside the imaged volume of a multislice helical CT scan. Br J Radiol 75(894):518–522, 2002CrossRefPubMed
26.
Zurück zum Zitat Tsalafoutas IA: The impact of overscan on patient dose with first generation multislice CT scanners. Phys Med 27(2):69–74, 2011CrossRefPubMed Tsalafoutas IA: The impact of overscan on patient dose with first generation multislice CT scanners. Phys Med 27(2):69–74, 2011CrossRefPubMed
27.
Zurück zum Zitat Medicine AAoPi. Use of water equivalent diameter for calculating patient size and size-specific dose estimates (SSDE) in CT (Task Group 220). College Park, 2014 Medicine AAoPi. Use of water equivalent diameter for calculating patient size and size-specific dose estimates (SSDE) in CT (Task Group 220). College Park, 2014
30.
Zurück zum Zitat McCollough C, Cody D, Edyvean S, Geise R, Gould B, Keat N, et al: The measurement, reporting, and management of radiation dose in CT. Report of AAPM Task Group. 23:1–28, 2008 McCollough C, Cody D, Edyvean S, Geise R, Gould B, Keat N, et al: The measurement, reporting, and management of radiation dose in CT. Report of AAPM Task Group. 23:1–28, 2008
31.
Zurück zum Zitat Sussman DL, Yao J, Summers RM: Automated fat measurement and segmentation with intensity inhomogeneity correction. SPIE Medical Imaging International Society for Optics and Photonics, 2010 Sussman DL, Yao J, Summers RM: Automated fat measurement and segmentation with intensity inhomogeneity correction. SPIE Medical Imaging International Society for Optics and Photonics, 2010
Metadaten
Titel
Open-Source Radiation Exposure Extraction Engine (RE3) with Patient-Specific Outlier Detection
verfasst von
Samuel J. Weisenthal
Les Folio
William Kovacs
Ari Seff
Vana Derderian
Ronald M. Summers
Jianhua Yao
Publikationsdatum
07.12.2015
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 4/2016
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-015-9852-y

Weitere Artikel der Ausgabe 4/2016

Journal of Digital Imaging 4/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.