Skip to main content
Erschienen in: Critical Care 1/2020

Open Access 01.12.2020 | Letter

Optic nerve sheath diameter guided detection of sepsis-associated encephalopathy

verfasst von: Varun Suresh

Erschienen in: Critical Care | Ausgabe 1/2020

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
Hinweise
A comment to this article is available online at https://​doi.​org/​10.​1186/​s13054-020-03395-3.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
I read with interest the research work done by Yang and colleagues [1] on measurement of ultrasonography-guided optic nerve sheath diameter (ONSD) in sepsis-associated encephalopathy (SAE) and its correlation with outcome. I appreciate the authors for successfully demonstrating raised ONSD in SAE patients; however, I have a few methodological concerns with the study.
The difference in ONSD across the three population groups compared in the study is sub-millimetric. Thus, an investigator not blinded to patient clinical condition can be biased to overestimate ONSD in SAE cases. This being a serious limitation authors could have sought for options of blinded ONSD measurements. It is also understood from the study results that elderly patients were included in the study population. A septated or trabeculated ONS being very common in elderly [2] such inclusion need not have essentially reflected the true ONSD.
I also wonder why a correlation between ONSD and serum albumin level was calculated. It is a very well-known fact that the blood-brain barrier is an osmotic interface [3] and oncotic pressure differences do not reflect on intracranial pressure. Do the authors essentially mean that hypoalbuminemia causes cerebral edema which indirectly reflects as high ONSD? It is inferred that this particular finding could be a statistical debate with zero clinical relevance.
Further, there is a considerable “blooming effect” artifact [4] in the ONSD images demonstrated by authors which could have affected the true ONSD measurements. Since majority of patients with SAE were on mechanical ventilation, a description of positive end-expiratory pressure and end-tidal carbon dioxide levels, which can directly affect ONSD [5], is distinctly wanted in the study results to exclude these confounders.
Unarguably Yang and colleagues’ effort on demonstrating ONSD threshold of ≥ 5.5 mm for detection of SAE is a novel contribution to knowledge, yet a narration on the concerns described here could have added more to the lucidity of author’s data.

Acknowledgements

None.
Not applicable
Not applicable

Competing interests

The author declares no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Yang Z, Qin C, Zhang S, Liu S, Sun T. Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study. Crit Care. 2020;24(1):235.CrossRef Yang Z, Qin C, Zhang S, Liu S, Sun T. Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study. Crit Care. 2020;24(1):235.CrossRef
2.
Zurück zum Zitat Killer HE, Jaggi GP, Miller NR. Papilledema revisited: is its pathophysiology really understood? Clin Exp Ophthalmol. 2009;37(5):444–7.CrossRef Killer HE, Jaggi GP, Miller NR. Papilledema revisited: is its pathophysiology really understood? Clin Exp Ophthalmol. 2009;37(5):444–7.CrossRef
3.
Zurück zum Zitat Obermeier B, Daneman R, Ransohoff RM. Development, maintenance and disruption of the blood-brain barrier. Nat Med. 2013;19(12):1584–96.CrossRef Obermeier B, Daneman R, Ransohoff RM. Development, maintenance and disruption of the blood-brain barrier. Nat Med. 2013;19(12):1584–96.CrossRef
4.
Zurück zum Zitat De Bernardo M, Vitiello L, Rosa N. Optic nerve sheath diameter ultrasound: optic nerve growth curve and its application to detect intracranial hypertension in children. Am J Ophthalmol. 2019;208:438.CrossRef De Bernardo M, Vitiello L, Rosa N. Optic nerve sheath diameter ultrasound: optic nerve growth curve and its application to detect intracranial hypertension in children. Am J Ophthalmol. 2019;208:438.CrossRef
5.
Zurück zum Zitat Bala R, Kumar R, Sharma J. A study to evaluate effect of PEEP and end-tidal carbon dioxide on optic nerve sheath diameter. Indian J Anaesth. 2019;63:537–43.CrossRef Bala R, Kumar R, Sharma J. A study to evaluate effect of PEEP and end-tidal carbon dioxide on optic nerve sheath diameter. Indian J Anaesth. 2019;63:537–43.CrossRef
Metadaten
Titel
Optic nerve sheath diameter guided detection of sepsis-associated encephalopathy
verfasst von
Varun Suresh
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 1/2020
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-020-03232-7

Weitere Artikel der Ausgabe 1/2020

Critical Care 1/2020 Zur Ausgabe