Abstract

Purpose

The subtalar arthrodesis using screws has been performed to manage traumatic subtalar arthritis. Even though clinically there might not have been big difference between using single screw or double screws for subtalar arthrodesis, a double screw fixation is expected to bring a better initial stability in a mechanical view. This study aimed to assess the optimal configuration of double screw fixation for subtalar arthrodesis.

Methods

From the CT-scanned images of an ankle of a Korean male (21 year old), polygon models of the talus and calcaneus were reconstructed. The polygon models were converted to tetrahedron finite elements. Young’s modulus was assigned locally to each element based on the Hounsfield unit, and a Poisson’s ratio of 0.4 was commonly. Four fixation configurations of double screw subtalar arthrodesis were modeled by combination of a same placement of a neck screw and one of four different placements of a dome screw, i.e., anterolateral (AL), anteromedial (AM), posterolateral (PL), and posteromedial (PM) placements. External and internal rotation torques of 4 N-m were applied when evaluating the stability of each fixation configuration.

Results

Among the four fixation configurations, the fixation configuration of a neck screw plus a PM dome screw had the least translation of 0.9 and 0.8 mm for external and internal rotational torques of 4 N-m, respectively. The fixation configuration of a neck screw plus a PM dome screw showed the least rotation of 5.0° and 4.8° for external and internal rotational torques of 4 N-m, respectively. The divergence angle or the contact length did not solely match well to the better stability. However, the integration of both the divergence angle of 2 screws and the contact length between screw and bones were proportionally related to the better rotational stability.

Conclusion

A posteromedial dome screw combined with a neck screw can be the best surgical choice, which will bring out excellent union rate of the subtalar arthrodesis as well as the best mechanical stability.
Literatur
1.
Zurück zum Zitat Alonso-Vazquez A, Lauge-Pedersen H, Lidgren L, Taylor M (2004) The effect of bone quality on the stability of ankle arthrodesis. A finite element study. Foot Ankle Int 25:840–850PubMed Alonso-Vazquez A, Lauge-Pedersen H, Lidgren L, Taylor M (2004) The effect of bone quality on the stability of ankle arthrodesis. A finite element study. Foot Ankle Int 25:840–850PubMed
2.
Zurück zum Zitat Alonso-Vazquez A, Lauge-Pedersen H, Lidgren L, Taylor M (2004) Initial stability of ankle arthrodesis with three-screw fixation. A finite element analysis. Clin Biomech 19:751–759CrossRef Alonso-Vazquez A, Lauge-Pedersen H, Lidgren L, Taylor M (2004) Initial stability of ankle arthrodesis with three-screw fixation. A finite element analysis. Clin Biomech 19:751–759CrossRef
3.
Zurück zum Zitat Beimers L, de Leeuw PA, van Dijk CN (2009) A 3-portal approach for arthroscopic subtalar arthrodesis. Knee Surg Sports Traumatol Arthrosc 17:830–834PubMedCrossRef Beimers L, de Leeuw PA, van Dijk CN (2009) A 3-portal approach for arthroscopic subtalar arthrodesis. Knee Surg Sports Traumatol Arthrosc 17:830–834PubMedCrossRef
4.
Zurück zum Zitat Chahal J, Stephen DJ, Bulmer B, Daniels T, Kreder HJ (2006) Factors associated with outcome after subtalar arthrodesis. J Orthop Trauma 20:555–561PubMedCrossRef Chahal J, Stephen DJ, Bulmer B, Daniels T, Kreder HJ (2006) Factors associated with outcome after subtalar arthrodesis. J Orthop Trauma 20:555–561PubMedCrossRef
5.
Zurück zum Zitat Christen D, Webster DJ, Muller R (2010) Multiscale modelling and nonlinear finite element analysis as clinical tools for the assessment of fracture risk. Philos Transact A Math Phys Eng Sci 368:2653–2668PubMedCrossRef Christen D, Webster DJ, Muller R (2010) Multiscale modelling and nonlinear finite element analysis as clinical tools for the assessment of fracture risk. Philos Transact A Math Phys Eng Sci 368:2653–2668PubMedCrossRef
6.
Zurück zum Zitat Chuckpaiwong B, Easley ME, Glisson RR (2009) Screw placement in subtalar arthrodesis: a biomechanical study. Foot Ankle Int 30:133–141PubMedCrossRef Chuckpaiwong B, Easley ME, Glisson RR (2009) Screw placement in subtalar arthrodesis: a biomechanical study. Foot Ankle Int 30:133–141PubMedCrossRef
7.
Zurück zum Zitat Clare MP, Lee WE 3rd, Sanders RW (2005) Intermediate to long-term results of a treatment protocol for calcaneal fracture malunions. J Bone Joint Surg Am 87:963–973PubMedCrossRef Clare MP, Lee WE 3rd, Sanders RW (2005) Intermediate to long-term results of a treatment protocol for calcaneal fracture malunions. J Bone Joint Surg Am 87:963–973PubMedCrossRef
8.
Zurück zum Zitat Cowin SC (1983) The mechanical and stress adaptive properties of bone. Ann Biomed Eng 11:263–295PubMedCrossRef Cowin SC (1983) The mechanical and stress adaptive properties of bone. Ann Biomed Eng 11:263–295PubMedCrossRef
9.
Zurück zum Zitat Dahm DL, Kitaoka HB (1998) Subtalar arthrodesis with internal compression for post-traumatic arthritis. J Bone Joint Surg Br 80:134–138PubMedCrossRef Dahm DL, Kitaoka HB (1998) Subtalar arthrodesis with internal compression for post-traumatic arthritis. J Bone Joint Surg Br 80:134–138PubMedCrossRef
10.
Zurück zum Zitat Davies MB, Rosenfeld PF, Stavrou P, Saxby TS (2007) A comprehensive review of subtalar arthrodesis. Foot Ankle Int 28:295–297PubMedCrossRef Davies MB, Rosenfeld PF, Stavrou P, Saxby TS (2007) A comprehensive review of subtalar arthrodesis. Foot Ankle Int 28:295–297PubMedCrossRef
11.
Zurück zum Zitat Dennyson WG, Fulford GE (1976) Subtalar arthrodesis by cancellous grafts and metallic internal fixation. J Bone Joint Surg Br 58-B:507–510PubMed Dennyson WG, Fulford GE (1976) Subtalar arthrodesis by cancellous grafts and metallic internal fixation. J Bone Joint Surg Br 58-B:507–510PubMed
12.
Zurück zum Zitat Diezi C, Favre P, Vienne P (2008) Primary isolated subtalar arthrodesis: outcome after 2 to 5 years followup. Foot Ankle Int 29:1195–1202PubMedCrossRef Diezi C, Favre P, Vienne P (2008) Primary isolated subtalar arthrodesis: outcome after 2 to 5 years followup. Foot Ankle Int 29:1195–1202PubMedCrossRef
13.
Zurück zum Zitat Easley ME, Trnka HJ, Schon LC, Myerson MS (2000) Isolated subtalar arthrodesis. J Bone Joint Surg Am 82:613–624PubMed Easley ME, Trnka HJ, Schon LC, Myerson MS (2000) Isolated subtalar arthrodesis. J Bone Joint Surg Am 82:613–624PubMed
14.
Zurück zum Zitat Frigg A, Dougall H, Boyd S, Nigg B (2010) Can porous tantalum be used to achieve ankle and subtalar arthrodesis? a pilot study. Clin Orthop Relat Res 468:209–216PubMedCrossRef Frigg A, Dougall H, Boyd S, Nigg B (2010) Can porous tantalum be used to achieve ankle and subtalar arthrodesis? a pilot study. Clin Orthop Relat Res 468:209–216PubMedCrossRef
15.
Zurück zum Zitat Gable SJ, Bohay DR, Manoli A 2nd (1995) Aiming guide for accurate placement of subtalar joint screws. Foot Ankle Int 16:238–239PubMed Gable SJ, Bohay DR, Manoli A 2nd (1995) Aiming guide for accurate placement of subtalar joint screws. Foot Ankle Int 16:238–239PubMed
16.
Zurück zum Zitat Gosch C, Verrette R, Lindsey DP, Beaupre GS, Lehnert B (2006) Comparison of initial compression force across the subtalar joint by two different screw fixation techniques. J Foot Ankle Surg 45:168–173PubMedCrossRef Gosch C, Verrette R, Lindsey DP, Beaupre GS, Lehnert B (2006) Comparison of initial compression force across the subtalar joint by two different screw fixation techniques. J Foot Ankle Surg 45:168–173PubMedCrossRef
17.
Zurück zum Zitat Hedstrom M (2004) Are patients with a nonunion after a femoral neck fracture more osteoporotic than others? BMD measurement before the choice of treatment? A pilot study of hip BMD and biochemical bone markers in patients with femoral neck fractures. Acta Orthop Scand 75:50–52PubMedCrossRef Hedstrom M (2004) Are patients with a nonunion after a femoral neck fracture more osteoporotic than others? BMD measurement before the choice of treatment? A pilot study of hip BMD and biochemical bone markers in patients with femoral neck fractures. Acta Orthop Scand 75:50–52PubMedCrossRef
18.
Zurück zum Zitat Huefner T, Thermann H, Geerling J, Pape HC, Pohlemann T (2001) Primary subtalar arthrodesis of calcaneal fractures. Foot Ankle Int 22:9–14PubMed Huefner T, Thermann H, Geerling J, Pape HC, Pohlemann T (2001) Primary subtalar arthrodesis of calcaneal fractures. Foot Ankle Int 22:9–14PubMed
19.
Zurück zum Zitat Joveniaux P, Harisboure A, Ohl X, Dehoux E (2010) Long-term results of in situ subtalar arthrodesis. Int Orthop 34:1199–1205PubMedCrossRef Joveniaux P, Harisboure A, Ohl X, Dehoux E (2010) Long-term results of in situ subtalar arthrodesis. Int Orthop 34:1199–1205PubMedCrossRef
20.
Zurück zum Zitat Kaneko TS, Pejcic MR, Tehranzadeh J, Keyak JH (2003) Relationships between material properties and CT scan data of cortical bone with and without metastatic lesions. Med Eng Phys 25:445–454PubMedCrossRef Kaneko TS, Pejcic MR, Tehranzadeh J, Keyak JH (2003) Relationships between material properties and CT scan data of cortical bone with and without metastatic lesions. Med Eng Phys 25:445–454PubMedCrossRef
21.
Zurück zum Zitat Lee KB, Saltzman CL, Suh JS, Wasserman L, Amendola A (2008) A posterior 3-portal arthroscopic approach for isolated subtalar arthrodesis. Arthroscopy 24:1306–1310PubMedCrossRef Lee KB, Saltzman CL, Suh JS, Wasserman L, Amendola A (2008) A posterior 3-portal arthroscopic approach for isolated subtalar arthrodesis. Arthroscopy 24:1306–1310PubMedCrossRef
22.
Zurück zum Zitat Lehnert B, Gosch C, Sims GE (2004) A plantar approach for fixation of subtalar joint arthrodesis. J Foot Ankle Surg 43:67–69PubMedCrossRef Lehnert B, Gosch C, Sims GE (2004) A plantar approach for fixation of subtalar joint arthrodesis. J Foot Ankle Surg 43:67–69PubMedCrossRef
23.
Zurück zum Zitat McGlamry MC, Robitaille MF (2004) Analysis of screw pullout strength: a function of screw orientation in subtalar joint arthrodesis. J Foot Ankle Surg 43:277–284PubMedCrossRef McGlamry MC, Robitaille MF (2004) Analysis of screw pullout strength: a function of screw orientation in subtalar joint arthrodesis. J Foot Ankle Surg 43:277–284PubMedCrossRef
24.
Zurück zum Zitat Thermann H, Hufner T, Schratt HE, Held C, Tscherne H (1999) Subtalar fusion after conservative or surgical treatment of calcaneus fracture. A comparison of long-term results. Unfallchirurg 102:13–22PubMedCrossRef Thermann H, Hufner T, Schratt HE, Held C, Tscherne H (1999) Subtalar fusion after conservative or surgical treatment of calcaneus fracture. A comparison of long-term results. Unfallchirurg 102:13–22PubMedCrossRef
25.
Zurück zum Zitat Vazquez AA, Lauge-Pedersen H, Lidgren L, Taylor M (2003) Finite element analysis of the initial stability of ankle arthrodesis with internal fixation: flat cut versus intact joint contours. Clin Biomech 18:244–253CrossRef Vazquez AA, Lauge-Pedersen H, Lidgren L, Taylor M (2003) Finite element analysis of the initial stability of ankle arthrodesis with internal fixation: flat cut versus intact joint contours. Clin Biomech 18:244–253CrossRef
26.
Zurück zum Zitat Weindel S, Schmidt R, Rammelt S, Claes L, Campe AV, Rein S (2008) Subtalar instability: a biomechanical cadaver study. Arch Orthop Trauma Surg 130:313–319PubMedCrossRef Weindel S, Schmidt R, Rammelt S, Claes L, Campe AV, Rein S (2008) Subtalar instability: a biomechanical cadaver study. Arch Orthop Trauma Surg 130:313–319PubMedCrossRef
27.
Zurück zum Zitat Zwipp H, Rammelt S, Endres T, Heineck J (2010) High union rates and function scores at midterm followup with ankle arthrodesis using a four screw technique. Clin Orthop Relat Res 468:958–968PubMedCrossRef Zwipp H, Rammelt S, Endres T, Heineck J (2010) High union rates and function scores at midterm followup with ankle arthrodesis using a four screw technique. Clin Orthop Relat Res 468:958–968PubMedCrossRef
Metadaten
Titel
Optimal double screw configuration for subtalar arthrodesis: a finite element analysis
verfasst von
Jun Young Lee
Yeon Soo Lee
Publikationsdatum
01.05.2011
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 5/2011
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1383-y

Weitere Artikel der Ausgabe 5/2011

Knee Surgery, Sports Traumatology, Arthroscopy 5/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.