Optimization and validation of a highly sensitive method for determining glyphosate in human urine by solid-phase extraction and liquid chromatography with tandem mass spectrometry: a methodological study

verfasst von: Hiroshi Nomura, Risa Hamada, Isao Saito, Kunihiko Nakane, Ritsuko Sawa, Miwa Ukai, Eiji Shibata, Mitsuo Sato, Michihiro Kamijima, Jun Ueyama

Erschienen in: Environmental Health and Preventive Medicine | Ausgabe 1/2020

Abstract

Background

Glyphosate and its salt formulations are nonselective herbicides that have been extensively used worldwide, both for residential and agricultural purposes. The possible carcinogenicity and teratogenicity of glyphosate remain to be elucidated. We developed a sensitive and high-throughput analytical method for urinary glyphosate using liquid chromatography-tandem mass spectrometry with the aim of contributing to glyphosate exposure assessment in epidemiological studies.

Methods

After urine dilution (creatinine matching dilution to 0.05 g creatinine/L), glyphosate was extracted using two types of solid phase extraction columns (SCX and NH2) with automated sample preparation instruments. The eluate was dried and dissolved in the mobile phase, followed by liquid chromatography-tandem mass spectrometry analysis. The optimized method was applied to urine samples obtained from 54 Japanese adults and children.

Results

The results from the validation study demonstrated good recoveries (91.0-99.6%), within- and between-run precisions (< 15%), low detection limits (0.1 μg/L), and lower limit of quantification (0.3 μg/L). The detection frequency and median concentration of the urinary glyphosate in Japanese subjects were 59% and 0.25 μg/L (0.34 μg/g creatinine).

Conclusions

Our reliable determination method was successful in measuring urinary glyphosate concentration. Moreover, this is the first biomonitoring report of urinary glyphosate levels in the Japanese general population.
Hinweise
Hiroshi Nomura and Risa Hamada contributed equally to this work.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
CreMDi0.05
Creatinine-matching dilution to 0.05 g/L
ELISA
Enzyme-linked immunosorbent assay
ESI
Electrospray ionization
FCMIA
Fluorescence covalent microbead immunosorbent assay
GC
Gas chromatography
GM
Geometric means
HBM
Human biomonitoring
HILIC
Hydrophilic interaction chromatography
HPLC
High-performance liquid chromatography
IS
Internal standard
LC
Liquid chromatography
LLOQ
Lower limit of quantification
LOD
Limit of detection
MA
Medronic acid
MRM
Multiple reaction monitoring
MS
Mass spectrometry
NCI
Negative chemical ionization
RSD
Relative standard deviation
SPE
Solid-phase extraction
S/N
Signal-to-noise ratio

Introduction

Glyphosate and its salt formulations are nonselective herbicides that have been extensively used worldwide, both for residential and agricultural purposes [1]. Not only in countries where their use is allowed for cultivation of genetically modified glyphosate-resistant crops such as wheat and corn but also in Japan and other counties, glyphosate is frequently used in agricultural fields, playgrounds, parking areas, and roads for weed control [2]. In Japan, the total domestic shipment of glyphosate, which is mainly composed of glyphosate isopropylamine salt and glyphosate potassium salt, has been growing steadily from 2300 tons in 2000 to 5670 tons in 2017 [3].
Whether the widely used glyphosate poses a possible risk to human health is a controversial matter. In 2015, glyphosate was classified as 2A “possibly carcinogenic to humans” by the International Agency for Research on Cancer [4]. On the other hand, several regulatory agencies [57] reviewed the scientific data and denied the carcinogenicity of glyphosate. More recently, a large-scale cohort study focused on the relationship between glyphosate exposure and health risks. The Agricultural Health Study, which is a prospective cohort study in North Carolina and Iowa, reported that a relationship was evident between glyphosate exposure and the risk of acute myeloid leukemia [8]. In view of the prospective, large-scale increase in the glyphosate usage level worldwide, nationwide studies covering exposure assessment of glyphosate followed by risk assessment are needed in Japan as well.
Generally, exposure assessment approaches are as follows: questionnaire/historical information, environmental monitoring (air, water, food, and soil), and/or human biomonitoring (HBM). Human biomonitoring is a unique approach for assessing the internal dose of chemicals not only in occupational but also in environmental settings, usually based on the analysis of human specimens (e.g., urine or blood). It plays a key role in providing quantitative information of individual exposure levels to epidemiological studies. In the case of glyphosate exposure estimation, HBM of urinary glyphosate has been used practically, because approximately 20-30% of glyphosate dose is excreted in urine within 48 h after the exposure [7]. In 2017, the German Federal Institute for Risk Assessment (BfR) conducted a risk assessment of glyphosate, using the HBM of glyphosate in urine obtained from over 2000 samples [9]. Moreover, some glyphosate HBM data from Germany [10], Denmark [11], Sri Lanka [12], the USA [13], and Ireland [14] (less than 100 urine samples) have also been reported, which is partly promoted by the development of glyphosate determination using urine.
In recent years, urinary glyphosate levels in the general population have been reported using various analytical methods (Table 1). Ligand binding assays, such as the enzyme-linked immunosorbent assay (ELISA), have some merits in terms of simple, rapid, and high-throughput data measurement in 96-well plates [19]. Chromatographic assays using gas chromatography (GC)-mass spectrometry (MS/MS) [10] and high-performance liquid chromatography (LC)-MS/MS have also been reported [14]. Each determination method has obvious benefits and drawbacks in terms of simplicity, reliability, and sensitivity. Given that large epidemiological studies and national surveys have been undertaken to reveal the chemical exposure risk to human health, there is an urgent need to further develop a high-throughput and sensitive method for the quantification of urinary glyphosate from general populations. Moreover, additional information is needed to reveal the characterization of urinary glyphosate concentration as exposure biomarkers.
Table 1
Analytical methods for detecting glyphosate in human urine samples
References
Sample preparation
Instrument for separation analysis
Limit of detection (μg/L)
Acquavella et al. [15]
Solid-phase extraction, derivatization
HPLC
1
Biagini et al. [16]
Derivatization
FCMIA
0.9
Curwin et al. [17]
Derivatization
FCMIA
0.9
Jayasumana et al. [12]
 
ELISA
0.6
Jensen et al. [18]
Dilution of urine
LC-MS/MS (ESI)
0.023
Connolly et al. [14]
Solid-phase extraction
LC-MS/MS (ESI)
0.5
Conrad et al. [10]
Derivatization
GC-MS/MS (NCI)
0.1 (LLOQ)
HPLC high-performance liquid chromatography, FCMIA fluorescence covalent microbead immunosorbent assay, ELISA enzyme-linked immunosorbent assay, LC liquid chromatography, GC gas chromatography, MS mass spectrometry, ESI electrospray ionization, NCI negative chemical ionization, LLOQ lower limit of quantification
Currently, there are limited HBM data available for glyphosate exposure assessment in Japan. This study aimed to develop a fully validated quantitative method for urinary glyphosate, which is applicable to the general population with no documented exposure to glyphosate using liquid chromatography-tandem mass spectrometry (LC-MS/MS).

Methods

Chemicals and reagents

A standard reagent of glyphosate (99.3% purity) was purchased from FUJIFILM Wako Pure Chemical Co. (Osaka, Japan) and glyphosate-13C2. 15N was obtained from Toronto Research Chemicals Inc. (Toronto, Canada) and used as an internal standard (IS). Ultrapure water (LC-MS grade), methanol (LC-MS grade), formic acid, acetic acid, 1 mol/L ammonium formate solution, and 6 mol/L hydrochloric acid were purchased from FUJIFILM Wako Pure Chemical Co. (Osaka, Japan). InfinityLab deactivator additive (composed of 5 mmol/L of medronic acid, MA) was obtained from Agilent Technologies, Inc. (CA, USA). Ammonia solution (28% in water) was obtained from Tokyo Chemical Industry Co., Ltd. (Tokyo, Japan). Water was distilled and deionized to 18 MΩ with a Milli-Q system (Millipore, MA, USA). A polymeric sulfonic acid bonded silica solid-phase extraction (SPE) product, ISOLUTE®-96 SCX 25 mg fixed well plate (Biotage, Uppsala, Sweden) and the polymeric aminopropyl bonded silica SPE product, ISOLUTE®-96 NH2 100 mg fixed well plate (Biotage, Uppsala, Sweden), was used for glyphosate extraction from urine samples. The SPE was performed using an automated system with plate formats called Extrahera™ (Biotage, Uppsala, Sweden).

Pooled urine samples and standard solutions

Pooled urine was collected from 96 healthy volunteers (63 males and 33 females), and was used for all optimization studies, matrix-matched calibration curves, and validation assays. Standard glyphosate and glyphosate-13C2, 15N were dissolved to a concentration of 1000 mg/L in water and diluted with water to prepare working reference solutions at designated concentrations. The glyphosate solution was stored at 4 °C, and the glyphosate-13C2, 15N solution was stored at −40 °C in the dark, which was used without a freeze-thaw cycle.

Sample preparation procedure

A flow chart of the sample preparation procedure for the measurement of urinary glyphosate is shown in Fig. 1. Initially, all urine samples were diluted to a creatinine concentration of 0.05 g/L (creatinine-matching dilution to 0.05 g/L, abbreviated to CreMDi0.05). This dilution was performed automatically using an OT-2 pipetting robot (NY, USA). One milliliter of the diluted urine samples was pipetted into a 96-well plate (each well volume was 2 mL), and 10 μL of IS solution (0.1 mg/L glyphosate-13C2, 15N) was added. After gentle shaking, the urine sample was subjected to SPE and was performed using the ExtraheraTM automation system (Biotage, Uppsala, Sweden) equipped with a nitrogen positive pressure unit.
Preconditioning of the SCX cartridge and the NH2 cartridge was achieved by washing with 1 mL of methanol, followed by conditioning with 1 mL of H2O. One milliliter of the prepared urine sample was loaded into the conditioned SCX cartridge. The passed through sample was directly collected in an NH2 cartridge. Moreover, the solutions were passed through the NH2 cartridge, and the target compounds were absorbed into the column. The NH2 cartridge was washed with 1 mL of a solution of methanol and H2O (1:9, v/v), followed by washing with 1 mL of a solution of methanol and 28% NH3 aqueous solution (140:1, v/v). Then, the target compounds were eluted with 1 mL of a solution of H2O and 28% NH3 aqueous solution (140:1, v/v; namely 0.2% NH3 solution).
The eluted fraction was transferred to polypropylene tubes and dried on a heat block at 110 °C. The residuals were dissolved in 100 μL of a solution of methanol and H2O (5:95, v/v) with 0.1% formic acid with 0.1% deactivator additive (5 μmol/L MA), and centrifuged at 20,000×g for 5 min after gentle vortexing. Finally, the supernatant was analyzed with LC-MS/MS.

Chromatography and mass spectrometry

The LC-MS/MS analysis was run on an Agilent 1260 Infinity Binary LC system coupled with an Agilent 6430 triple quadrupole mass spectrometer (Agilent Technologies, Inc., CA, USA). The LC operating conditions were as follows: LC column, Scherzo SM-C18 MF (Imtakt, Kyoto, Japan), 100 × 2 mm i.d., 3 μm silica; mobile phase A, methanol and H2O (5:95, v/v) containing 0.1% of formic acid with 0.1% of the deactivator additive (5 μmol/L MA), mobile phase B; methanol and 20 mmol/L ammonium formate solution (20:80, v/v) with 0.1% of the deactivator additive (5 μmol/L MA); gradient condition of mobile phase B, 0% (0-5 min)-90% (5-10 min)-0% (10-12 min); the total flow rate, 0.2 mL min−1; total run time per sample, 12 min; and injection volume, 10 μL. Mobile phase A (40 μL) was injected 3 times (run time was 0 min) between each sample analysis to prevent carry-over contamination.
The MS/MS was operated with an electrospray ionization (ESI) source in positive ion mode with multiple reaction monitoring (MRM). The nebulizer gas pressure, source temperature, and gas flow were 50 psi, 350 °C, and 10 L/min, respectively. The capillary voltage was 4000 V (positive mode), and high-purity nitrogen gas was used in the collision cell. Table 2 shows the optimized MRM parameters, and retention times for glyphosate and IS. The chromatograph and mass spectrogram data were collected using the Mass Hunter Software Workstation (Agilent Technologies).
Table 2
Compound-specific mass spectrometer settings
Compounds
Fragmentor (V)
Collision energy (eV)
Precursor ion (m/z)
Product ion (m/z)
Retention time (min)
Glyphosate
70
6
170
88.1 (Q)
3.4
70
20
170
60.1 (C)
3.4
70
28
170
42.2 (C)
3.4
Glyphosate-13C2, 15N
70
7
173
91.1 (C)
3.4
70
7
173
62.2 (Q)
3.4
Q quantification ion, C confirmation ion

Assay validation

The present bioanalytical method was validated in terms of matrix effects, precision, extraction recovery, linearity, limit of detection (LOD), lower limit of quantification (LLOQ), prepared sample stability, freeze-thaw stability, long-term stability, and robustness.
The matrix effects are represented as the absolute matrix factor and relative matrix factor. The absolute matrix factor was calculated by dividing the peak area of glyphosate in the urine matrix by the peak area of glyphosate standard solution dissolved in the LC mobile phase A. The relative matrix factor was represented by dividing the glyphosate/IS peak area ratio in the matrix by those of glyphosate standard solution in the mobile phase A. Glyphosate standard solution and IS solutions were spiked just before the LC-MS/MS analysis (final concentrations were 1 μg/L of urine). The matrix factors were calculated using 10 individual urine samples (8 male and 2 female adults) to evaluate the range of matrix effects. Tenfold dilution urine from the 10 individuals was also used for the matrix factor calculation to compare the creatinine-matching dilution method. The average creatinine concentration after tenfold dilution was 0.08 g/L.
The within-run precision was examined by determination of pooled urine spiked with glyphosate at concentrations of 0.33, 0.67, and 1.33 μg/L (n = 6). The between-run precision was evaluated at concentrations of 0.33, 0.67, and 1.33 μg/L (n = 2) for five consecutive days.
Absolute recovery rates were estimated at three concentration levels: 0.33, 0.67, and 1.33 μg/L (n = 3). Recovery rates were calculated by comparing the peak areas derived from the following two sets of procedures. Samples in the first set were spiked with glyphosate prior to sample preparation. The second set of samples was spiked just before LC-MS/MS analysis.
Calibration curves using urine were represented by glyphosate/IS. The peak area ratio versus the concentrations of glyphosate ranged from 0.17 to 2 μg/L (0.17, 0.33, 0.5, 1, 2, and 5 μg/L). The concentration ranges were designed referring to urinary glyphosate concentrations in previous reports [10, 14]. The linearity of the calibration curve was determined by linear regression analysis. Calibration curves with coefficients of determination (r2) ≥ of 0.97 were considered linear.
The LOD and LLOQ were derived from the assumption of signal-to-noise ratios of 3 and 10, respectively. In addition, the LLOQ of within-run precision was defined as less than 20% (relative standard deviation, %RSD).
The robustness of the developed method was tested by continuous analysis of the prepared samples. We used glyphosate-spiked urine at a concentration of 0.67 μg/L, and after the sample preparation procedure, the samples were analyzed eighty-six times in a row. We evaluated the %RSD of glyphosate/IS peak area ratios for all analyses.

Sample stability

The stability of the prepared samples was tested through a duplicate assay at a concentration of 0.67 μg/L glyphosate. The prepared sample was stored in an LC autosampler at 4 °C and analyzed at five-time points as follows: 0 (immediately), 18, 24, 48, and 72 h. Stability was assessed by comparing the glyphosate/IS peak area ratios of samples stored for 18, 24, 48, and 72 h with those of samples stored for 0 h.
Freeze-thaw stability of glyphosate in urine was evaluated at concentrations of 0.67 μg/L. Each freeze-thaw cycle consisted of a minimum of 12 h freezing at −80 °C followed by a complete thaw in tap water running at room temperature for 10 min. Samples were analyzed after the third freeze-thaw cycle. The stability was evaluated by comparing glyphosate/IS peak area ratios with those of samples that did not undergo freeze-thaw cycles (n = 3).
The long-term stability of glyphosate in urine was estimated using urine samples spiked at a concentration of 0.67 μg/L. We stored the urine samples for 1 week at ambient temperature (25 °C), and those for 1 week and 1 month at 4 °C and −80 °C, and analyzed their glyphosate concentrations. The peak area ratios of the stored samples were compared with those of non-stored and spiked urine samples (n = 3).

Application of methods to urine samples

Our method was applied to human spot urine samples obtained from children (group A), adults (group B), and farmers (group C). Prior to enrollment in the study, an informed consent form was signed by each subject or the parent giving the right to the use of urine samples for research purposes. Morning voids of children were collected from 3-year-old children (10 males and 10 females) who attended a municipal health check program in a suburban area of Aichi, the central region of Japan. Group B consisted of 24 adults composed of 14 males and 10 females (age range 31-63 years) living in the Kyushu region of Japan. The adult samples (group C) were composed of eight male and two female farmers (age range 44-73 years) living in the Kyushu region. Collected spot urine samples were transported at 4 °C, and then stored at −80 °C until analysis.
Creatinine analysis was completed on all samples using a previously reported method [20] with a high-performance liquid chromatograph equipped with a UV detector. Undetectable urinary concentrations of glyphosate were estimated as the LOD value divided by the square root of 2 [21] to calculate geometric means (GM).

Results

Optimization of the LC column and mobile phase

Given that glyphosate is an ionic and highly water-soluble compound, it is difficult to hold it using a common LC separation column such as a reversed-phase column. Therefore, we selected the ODS column (Scherzo SM-C18 MF) consisting of C18, weak anion, and weak cation ligands as the LC column. In addition, as glyphosate is a metal coordination compound with a phosphate group in its structure, it tends to show poor peak shape and sensitivity by interacting with the metal of the steel column, metallic pipes, and the solution of the mobile phase. With the aim of minimizing these effects and improving the detection limit of glyphosate, we used MA deactivator additive as the LC mobile phase additive. The use of MA improved glyphosate peak intensity (Fig. 2).

Optimization of sample preparation

The SPE procedure for glyphosate extraction was adopted in this study to ensure easy handling and high purification. As shown in Fig. 1, we used two types of solid-phase extraction columns. The good selectivity was suggested from the result of the mass chromatogram of pooled urine spiked with glyphosate at concentrations ranging from 0.13 to 3.51 μg/L (Fig. 3).

Assay validation

Matrix effects data are shown in Table 3. The CreMDi0.05 method of all samples showed better %RSD values than the tenfold dilution.
Table 3
Absolute and relative matrix factors of 10 individuals
Sample ID
Creatinine (g/L)
Absolute matrix factors (row data of peak area)
Relative matrix factors (with IS collection)
Tenfold dilution
CreMDi0.05
Tenfold dilution
CreMDi0.05
1
1.28
0.57
0.69
1.10
0.90
2
0.48
1.02
0.75
1.02
0.92
3
0.32
0.95
0.79
1.18
1.07
4
1.13
0.60
0.83
0.95
1.03
5
0.45
1.76
0.90
1.51
1.10
6
1.62
0.51
0.72
1.34
0.92
7
0.79
0.84
0.77
1.97
1.10
8
0.21
1.12
0.83
1.03
1.21
9
0.69
0.49
0.72
1.57
1.02
10
1.37
0.82
0.52
1.34
0.80
%RSD
 
41.9
12.9
22.9
11.4
CreMDi0.05 creatinine-matching dilution to concentration at 0.05 g/L, RSD relative standard deviation
The absolute recovery rate, precision, and sensitivity parameters are summarized in Table 4. The absolute recovery rates ranged from 91.0 to 99.6%. For the within-run precision, the %RSD was 11.4% or less at a concentration of 0.33 μg/L. For the between-run precision, the %RSD was 14.0% at a concentration of 0.33 μg/L. The calibration curve with coefficients of determination (r2) was 0.998. The LOD and LLOQ values were 0.1 μg/L and 0.3 μg/L, respectively.
Table 4
Precision, recovery rate, linearity, LOD, and LLOQ data of the analytical procedure
 
Concentration (μg/L urine)
n
Results
Absolute recovery rate
(%)
0.33
3
99.6
 
0.67
3
91.0
1.33
3
97.8
Within-run precision
(%RSD)
0.33
6
11.4
 
0.67
6
8.6
1.33
6
5.6
Between-run precision
(%RSD)
0.33
5
14.0
 
0.67
5
6.8
1.33
5
9.6
Calibration curve
 Slope
  
0.144
 Intercept
  
0.000
r2
  
0.998
LOD (μg/L, S/N = 3)
  
0.1
LLOQ (μg/L)
  
0.3
n number of observations, RSD relative standard deviation, LOD limit of detection, LLOQ lower limit of quantification, S/N signal-to-noise ratio
Figure 4 shows the result of eighty-six consecutive analyses within 22 h. Glyphosate peak areas were slightly varied and increased (left), while the glyphosate/IS peak area ratios were stable (%RSD was 5.6%) throughout the analysis (right). One possible cause of the increase in the peak area is the concentration of the prepared samples in the LC injector.

Sample stability

The prepared samples were stable for at least 3 days at 0.67 μg/L concentration (Table 5). The storage stabilities of glyphosate in the urine were studied by storage for at most 1 week at 25 °C, or for at most 1 month at 4 °C or −80 °C, and three freeze-thaw cycles. Glyphosate in urine was stable through a few freeze-thaw cycles. Furthermore, the peak area ratios of glyphosate/IS in the stored urine was stable under each condition (Table 5).
Table 5
Glyphosate stabilities in urine
 
Concentration (μg/L urine)
n
Storage period
% of 0 h
Prepared sample stability
0.67
2
0 h
 
0.67
2
18 h
96
0.67
2
24 h
99
0.67
2
48 h
98
0.67
2
72 h
95
Freeze-thaw stability (three cycles)
0.67
3
 
92
Long-term stability
25 °C
0.67
3
1 week
94
4 °C
0.67
3
1 week
92
 
0.67
3
1 month
105
−80 °C
0.67
3
1 week
105
 
0.67
3
1 month
100
n number of observations

Application of methods to urine samples

Our optimized method was applied to Japanese general people, and the resulting data are shown in Table 6. The detection frequencies (>LOD) of glyphosate were 70% for group A, 33% for group B, and 100% for group C. The maximum glyphosate values were 2.59 μg/g creatinine for group A, 0.68 μg/g creatinine for group B, and 1.72 μg/g creatinine for group C.
Table 6
Detection rates, geometric means, and percentiles of urinary glyphosate concentrations
Group
Sample size
>LOD (%)a
Units
GM
Selected percentiles
Max.
5th
25th
50th
75th
95th
A
20
70
μg/L
0.36
<LOD
<LOD
0.54
1.17
1.43
1.44
   
μg/g cre
0.37
<LOD
<LOD
0.40
0.88
2.57
2.59
B
24
33
μg/L
NCb
<LOD
<LOD
<LOD
0.16
1.84
1.99
   
μg/g cre
NCb
<LOD
<LOD
<LOD
0.34
0.65
0.68
C
10
100
μg/L
0.47
0.21
0.29
0.56
0.73
0.77
0.77
   
μg/g cre
0.67
0.43
0.47
0.67
0.83
1.72
1.72
Total
54
59
μg/L
0.24
<LOD
<LOD
0.25
0.70
1.41
1.99
   
μg/g cre
0.26
<LOD
<LOD
0.34
0.66
1.95
2.59
LOD limit of detection, cre creatinine, GM geometric mean, NC not calculated, <LOD lower than level of limit of detection
aPercent of detection frequency
bGM was not calculated due to low detection rate

Discussion

There are two essential findings for the development of a quantitative method that is successfully applied to quantify low concentrations of urinary glyphosate with reliable analysis. First, low recovery and a reduction in the sensitivity of the phosphorylated compound glyphosate in LC-MS/MS analysis are mitigated by our novel approach using a metal-free analytical system with a metal deactivating agent and multi-mode columns. Second, the urine CreMDi0.05 method has enabled the stable and adequate reproducibility of glyphosate quantitative results not only from pooled urine samples but also from urine obtained from various persons.
Table 7 shows the comparative tables of determination method reports of urinary glyphosate using LC-MS/MS, including our present study. Each report has some strengths and weaknesses. For example, Jensen and colleagues reported the simplest sample preparation method [18]. Sample preparation of just dilution of urine may have a negative effect on LC-MS/MS sensitivity and reliability after repeated injection, leading to the anticipated system downtime to clean the MS ion source and HPLC system. Connolly and colleagues have successfully reported the urinary glyphosate concentration level in the general population using a commonly used LC-MS/MS system [14]. Unfortunately, the sensitivity and system validation assay data are insufficient. Our present method was optimized for sensitive and high-throughput application to many samples collected in an epidemiological study.
Table 7
Comparison of the present method with data obtained in two previously described methods
References
Jensen et al. 2016 [18]
Connolly et al. 2017 [14]
Present method
Analytical apparatus
LC-MS/MS (ESI)
LC-MS/MS (ESI)
LC-MS/MS (ESI)
Mass spectrometer
API5500 (ABSciex)
API3200 (ABSciex)
6430 (Agilent)
Analytical column
Cation-H
30 mm × 4.6 mm
(Bio-Rad)
Zorbax SB-C3
150 × 4.6 mm 5 μm
(Agilent)
Scherzo SM-C18 MF
100 × 2 mm 3 μm silica (Imtakt)
Sample preparation
Dilution
Solid-phase extraction (SAX)
Solid-phase extraction (SCX + NH2)
Internal standard
Glyphosate-13C3, 15N
Glyphosate-2-13C, 15N
Glyphosate-13C2, 15N
Amount of sample (μL)
600
500
ca. 100 (depend on the creatinine concentration)
Average recovery (%)
92-102 (0.1-800 μg/L, n = 6)
 
91.0-99.6 (0.33-1.33 μg/L, n = 3)
Intra-day precision (%RSD)
2.0-11.6 (0.1-800 μg/L, n = 6)
3.54 (n = 10)
5.6-11.4 (0.33-1.33 μg/L, n = 6)
Inter-day precision (%RSD)
 
9.96 (n = 40 over 4 runs)
6.8-14.0 (0.33-1.33 μg/L, n = 10 over 5 runs respectively)
LLOQ (μg/L)
0.10
 
0.3
LOD (μg/L)
0.023
0.5
0.1
Analytical stability
  
86 or more injection
Verification of matrix effect
Confirmed with pool urine
 
Confirmed with 10 individual urine
Prepared sample stability
  
72 h
Freeze-thaw sample stability
3 cyclesa (only human milk)
 
3 cycles
Long-term sample stability
5 °C (24 h)a
−20 °C (3 months)a
 
25 °C (1 week)
4 °C (1 month)
−80 °C (1 month)
Application of methods to urine samples
 
n = 31, detection rate 45%, max 10.66 μg/L
n = 54, detection rate 59%, max 1.99 μg/L
aMatrix is human milk
It is well-known that the metal coordination compound glyphosate tends to cause tailing of peaks and intensity loss, resulting in low sensitivity and unreliable LC-based analysis. Moreover, the use of glass material has reduced the glyphosate in solution, due in part to ionic and/or hydrophobic adsorption to the siloxane and silanol. Therefore, metal- and glass-free analytical methods are essential for sensitive and reliable glyphosate analysis. As a countermeasure, an HPLC system with nonmetal tubing (mainly polyetherketone material) and/or capping the metal using phosphoric acid solution has been adopted in the glyphosate determination method [18]. Unfortunately, this countermeasure gave our laboratory far from satisfactory results in terms of reliability and sensitivity. As shown in Fig. 2, the mobile phase additive reagent MA Deactivator altered glyphosate sensitivity, leading to high reliability at low glyphosate concentration levels. This may be mainly due to the more inert environment for glyphosate by effective capping of free metal ions in the mobile phase and flow path, including the injection needle and analytical column, compared with phosphoric acid. Moreover, the Scherzo SM-C18 MF we selected provided a sufficient peak shape and high signal-to-noise ratio of glyphosate in chromatograms relative to previously reported column hydrophilic interaction chromatography (HILIC) [22] and an aqueous compatible reversed-phase [18] with whichever of some mobile phase (data not shown).
The CreMDi method provided satisfactory validation results caused by restraining the variation of matrix factors even in individual urine samples. The creatinine concentration reflects the degree of urine concentration, which has intra- and inter-individual differences ranging from 0.21 to 5.44 g/L in the study subjects. It is necessary to standardize the amount of substances in urine to ensure the equal effect of glyphosate purification by the SPE column. A complicated liquid handling is needed for the CreMDi0.05 method. However, the CreMDi method also has the advantage of assigning approximately the same LOD or LLOQ values to individual urine samples, with the same background chromatogram and unifying matrix effects.
Although the procedure was complicated for the two types of SPE, the time required for sample processing was short because the test design allowed the SPE operation using an automatic device (Extrahera™). A combination of strong cation exchange and a weak anion-exchange column (SCX and NH2) was selected as a better preanalytical procedure for our LC-MS/MS condition. The preanalytical procedure using two types of SPE columns involves a cost relative to the other method [14, 19]. Addressing this disadvantage was expected to bring benefits in terms of the chromatogram peak specificity (Fig. 3) and stable sensitivity evidenced by the repetition test of sample injection (more than 86 injection, Fig. 4). In this study, glyphosate metabolite aminomethylphosphonic acid was excluded from the urinary target biomarker because of its low urinary excretion rate [7]. However, there are reports that glyphosate and aminomethylphosphonic acid have a correlation with urinary excretion concentration [10]. Therefore, we will consider glyphosate and aminomethylphosphonic acid as analytes in the future.
The present method has been successfully applied to urine samples of Japanese children, adults, and farmers. This implies that our method can be applied to the HBM of urinary glyphosate even at environmental exposure levels. Statistical comparison among the three groups was not performed due to the small sample size. Table 8 shows the median and maximum levels of urinary glyphosate in the general population reported within 10 years. The urinary glyphosate concentration of the Japanese seems to be approximately the same as or lower than that of German or Irish studies. However, the results of the urinary concentration of glyphosate in our study are not conclusive as representative Japanese data because of the small sample size and limited sampling area. Above all, the results of this study strongly suggest that our method can be readily applied to biomonitoring of urinary glyphosate in general populations. To assess the precise exposure of glyphosate using human biomonitoring, a further study is needed to collect basic information, including the relationship between intake and excretion of glyphosate.
Table 8
Urinary glyphosate concentrations reported in previous papers
Author, sampling country, sampling year
Study population (years)
Sample size
LOD (μg/L)
Detection rate
Units
Median
Max.
Knudsen et al., Denmark, 2011 [11]
Children (6-11)
14
NR
100%
μg/L
1.96
3.31
Mothers (31-52)
13
NR
100%
μg/L
1.28
3.22
Conrad et al., Germany, 2015 [10]
Adults (20-29)
399
0.1 (LLOQ)
31.8%
μg/L
NR
2.80
Jayasmana et al., Sri Lanka, NR [12]
Adults (39.3 ± 11.5)
10
0.6
NR
μg/L
3.3
5.5
   
μg/g cre
2.4
4.4
Parvez et al., USA (Indiana), 2015-2016 [13]
Pregnant Women (18-40)
71
0.1
93%
μg/L
3.25a
7.20
Connolly et al., Ireland, 2017 [14]
Farmer workers (33-66)
31
0.5
45%
μg/L
1.35b
10.66
LOD limit of detection, LLOQ lower limit of quantification, NC not calculated, NR not reported, cre creatinine
aMedian concentration except for <LOD samples
bArithmetic mean

Conclusion

We have developed a highly sensitive and reliable method for the quantitation of urinary glyphosate, and we have applied this method to detect glyphosate in the urine samples of young Japanese children and adults. The present study is the first to report urinary concentrations and glyphosate distributions in the Japanese people. Although much information about the glyphosate exposure level remains poorly understood, this promising method would contribute to the development of future research on risk assessment from glyphosate exposure in the general population, including children and adults with occupational exposure.

Acknowledgements

We would like to thank all the donors for generously providing the samples. We would also like to thank all the staff at Nagoya University for their support in this study.
The Ethics Committees of Nagoya University Graduate School of Medicine approved the study protocol (Approval number: 20110026, 20170280, and 14401). An informed consent form was signed by adult subjects or the guardians giving the right to the use of urine samples for research purposes.
Not applicable.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Literatur
1.
Zurück zum Zitat Woodburn AT. Glyphosate: production, pricing and use worldwide. Pest Manag Sci. 2000;56(4):309–12.CrossRef Woodburn AT. Glyphosate: production, pricing and use worldwide. Pest Manag Sci. 2000;56(4):309–12.CrossRef
4.
Zurück zum Zitat International Agency for Research on Cancer. IARC monographs on the evaluation of carcinogenic risks to humans, vol. 112. Lyon: IARC; 2017. International Agency for Research on Cancer. IARC monographs on the evaluation of carcinogenic risks to humans, vol. 112. Lyon: IARC; 2017.
6.
Zurück zum Zitat European Food Safety Authority (EFSA). Conclusion on the peer review of the pesticide risk assessment of the active substance glyphosate. EFSA J. 2017;15(9):e04979. European Food Safety Authority (EFSA). Conclusion on the peer review of the pesticide risk assessment of the active substance glyphosate. EFSA J. 2017;15(9):e04979.
8.
Zurück zum Zitat Andreotti G, Koutros S, Hofmann JN, Sandler DP, Lubin JH, Lynch CF, Lerro CC, De Roos AJ, Parks CG, Alavanja MC, Silverman DT, Beane Freeman LE. Glyphosate use and cancer incidence in the agricultural health study. J Natl Cancer Inst. 2018;110(5):509–16. Andreotti G, Koutros S, Hofmann JN, Sandler DP, Lubin JH, Lynch CF, Lerro CC, De Roos AJ, Parks CG, Alavanja MC, Silverman DT, Beane Freeman LE. Glyphosate use and cancer incidence in the agricultural health study. J Natl Cancer Inst. 2018;110(5):509–16.
10.
Zurück zum Zitat Conrad A, Schröter-kermani C, Hoppe H, Rüther M, Pieper S, Kolossa-gehring M. Time trend (2001 to 2015) of human exposure to a widely used herbicide. Int J Hyg Environ Health. 2017;220:8–16.CrossRef Conrad A, Schröter-kermani C, Hoppe H, Rüther M, Pieper S, Kolossa-gehring M. Time trend (2001 to 2015) of human exposure to a widely used herbicide. Int J Hyg Environ Health. 2017;220:8–16.CrossRef
11.
Zurück zum Zitat Knudsen LE, Hansen PW, Mizrak S, Hansen HK, Mørck TA, Nielsen F, Siersma V, Mathiesen L. Biomonitoring of Danish school children and mothers including biomarkers of PBDE and glyphosate. Rev Environ Health. 2017;32(3):279–90.CrossRef Knudsen LE, Hansen PW, Mizrak S, Hansen HK, Mørck TA, Nielsen F, Siersma V, Mathiesen L. Biomonitoring of Danish school children and mothers including biomarkers of PBDE and glyphosate. Rev Environ Health. 2017;32(3):279–90.CrossRef
12.
Zurück zum Zitat Jayasumana C, Gunatilake S, Siribaddana S. Simultaneous exposure to multiple heavy metals and glyphosate may contribute to Sri Lankan agricultural nephropathy. BMC Nephrol. 2015;16:103.CrossRef Jayasumana C, Gunatilake S, Siribaddana S. Simultaneous exposure to multiple heavy metals and glyphosate may contribute to Sri Lankan agricultural nephropathy. BMC Nephrol. 2015;16:103.CrossRef
13.
Zurück zum Zitat Parvez S, Gerona RR, Proctor C, Friesen M, Ashby JL, Reiter JL, Lui Z. Winchester PD. Glyphosate exposure in pregnancy and shortened gestational length: a prospective Indiana birth cohort study. Environ Health. 2018;17(1):1–12.CrossRef Parvez S, Gerona RR, Proctor C, Friesen M, Ashby JL, Reiter JL, Lui Z. Winchester PD. Glyphosate exposure in pregnancy and shortened gestational length: a prospective Indiana birth cohort study. Environ Health. 2018;17(1):1–12.CrossRef
14.
Zurück zum Zitat Connolly A, Jones K, Galea KS, Basinas I, Kenny L, Mcgowan P, Coggins M. Exposure assessment using human biomonitoring for glyphosate and fluroxypyr users in amenity horticulture. Int J Hyg. Environ Health. 2017;220:1064–73.CrossRef Connolly A, Jones K, Galea KS, Basinas I, Kenny L, Mcgowan P, Coggins M. Exposure assessment using human biomonitoring for glyphosate and fluroxypyr users in amenity horticulture. Int J Hyg. Environ Health. 2017;220:1064–73.CrossRef
15.
Zurück zum Zitat Acquavella JF, Alexander BH, Mandel JS, Gustin C, Baker B, Chapman P. Glyphosate biomonitoring for farmers and their families: results from the farm family exposure study. Environ Health Perspect. 2004;112(3):321–6.CrossRef Acquavella JF, Alexander BH, Mandel JS, Gustin C, Baker B, Chapman P. Glyphosate biomonitoring for farmers and their families: results from the farm family exposure study. Environ Health Perspect. 2004;112(3):321–6.CrossRef
16.
Zurück zum Zitat Biagini RE, Smith JP, Sammons DL, MacKenzie BA, Striley CAF, Robertson SK, Snawder JE. Development of a sensitivity enhanced multiplexed fluorescence covalent microbead immunosorbent assay (FCMIA) for the measurement of glyphosate, atrazine and metolachlor mercapturate in water and urine. Anal Bioanal Chem. 2004;379:368–74.CrossRef Biagini RE, Smith JP, Sammons DL, MacKenzie BA, Striley CAF, Robertson SK, Snawder JE. Development of a sensitivity enhanced multiplexed fluorescence covalent microbead immunosorbent assay (FCMIA) for the measurement of glyphosate, atrazine and metolachlor mercapturate in water and urine. Anal Bioanal Chem. 2004;379:368–74.CrossRef
17.
Zurück zum Zitat Curwin BD, Hein MJ, Sanderson WT, Striley C, Heederik D, Kromhout H, Alavanja MC. Urinary pesticide concentrations among children, mothers and fathers living in farm and non-farm households in Iowa. Ann Occup Hyg. 2007;51(1):53–65.CrossRef Curwin BD, Hein MJ, Sanderson WT, Striley C, Heederik D, Kromhout H, Alavanja MC. Urinary pesticide concentrations among children, mothers and fathers living in farm and non-farm households in Iowa. Ann Occup Hyg. 2007;51(1):53–65.CrossRef
18.
Zurück zum Zitat Jensen PK, Wujcik CE, Mcguire MK, Mcguire MA. Validation of reliable and selective methods for direct determination of glyphosate and aminomethylphosphonic acid in milk and urine using LC-MS/MS. J Environ Sci Health B. 2016;51(4):254–9.CrossRef Jensen PK, Wujcik CE, Mcguire MK, Mcguire MA. Validation of reliable and selective methods for direct determination of glyphosate and aminomethylphosphonic acid in milk and urine using LC-MS/MS. J Environ Sci Health B. 2016;51(4):254–9.CrossRef
19.
Zurück zum Zitat Byer J, Struger J, Klawunn P, Todd A, Sverko E. Low cost monitoring of glyphosate in surface waters using the ELISA method: an evaluation. Environ Sci Technol. 2008;42(16):6052–7.CrossRef Byer J, Struger J, Klawunn P, Todd A, Sverko E. Low cost monitoring of glyphosate in surface waters using the ELISA method: an evaluation. Environ Sci Technol. 2008;42(16):6052–7.CrossRef
20.
Zurück zum Zitat Ueyama J, Harada KH, Koizumi A, Sugiura Y, Kondo T, Saito I, Kamijima M. Temporal levels of urinary neonicotinoid and dialkylphosphate concentrations in Japanese women between 1994 and 2011. Environ Sci Technol. 2015;49(24):14522–8.CrossRef Ueyama J, Harada KH, Koizumi A, Sugiura Y, Kondo T, Saito I, Kamijima M. Temporal levels of urinary neonicotinoid and dialkylphosphate concentrations in Japanese women between 1994 and 2011. Environ Sci Technol. 2015;49(24):14522–8.CrossRef
21.
Zurück zum Zitat Hornung RW, Reed LD. Estimation of average concentration in the presence of nondetectable values. Appl Occup Environ Hyg. 1990;5:46–51.CrossRef Hornung RW, Reed LD. Estimation of average concentration in the presence of nondetectable values. Appl Occup Environ Hyg. 1990;5:46–51.CrossRef
22.
Zurück zum Zitat Yoshioka N, Asano M, Kuse A, Mitsuhashi T, Nagasaki Y, Ueno Y. Rapid determination of glyphosate, glufosinate, bialaphos, and their major metabolites in serum by liquid chromatography-tandem mass spectrometry using hydrophilic interaction chromatography. J Chromatogr A. 2011;1218(23):3675–80.CrossRef Yoshioka N, Asano M, Kuse A, Mitsuhashi T, Nagasaki Y, Ueno Y. Rapid determination of glyphosate, glufosinate, bialaphos, and their major metabolites in serum by liquid chromatography-tandem mass spectrometry using hydrophilic interaction chromatography. J Chromatogr A. 2011;1218(23):3675–80.CrossRef
Metadaten
Titel
Optimization and validation of a highly sensitive method for determining glyphosate in human urine by solid-phase extraction and liquid chromatography with tandem mass spectrometry: a methodological study
verfasst von
Hiroshi Nomura
Risa Hamada
Isao Saito
Kunihiko Nakane
Ritsuko Sawa
Miwa Ukai
Eiji Shibata
Mitsuo Sato
Michihiro Kamijima
Jun Ueyama
Publikationsdatum
01.12.2020
Verlag
BioMed Central
Erschienen in
Environmental Health and Preventive Medicine / Ausgabe 1/2020
Print ISSN: 1342-078X
Elektronische ISSN: 1347-4715
DOI
https://doi.org/10.1186/s12199-020-00918-w

Weitere Artikel der Ausgabe 1/2020

Environmental Health and Preventive Medicine 1/2020 Zur Ausgabe