Skip to main content
Erschienen in: Neuroradiology 3/2019

04.01.2019 | Diagnostic Neuroradiology

Optimization of 3D phase contrast venography for the assessment of the cranio-cervical venous system at 1.5 T

verfasst von: Mona Salehi Ravesh, Ulf Jensen-Kondering, Julia Juhasz, Sönke Peters, Monika Huhndorf, Joachim Graessner, Thomas W. D. Möbius, Marcus Both, Olav Jansen, Jan-Bernd Hövener

Erschienen in: Neuroradiology | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The aim of this work was to optimize a three-dimensional (3D) phase-contrast venography (PCV) product MR pulse sequence in order to obtain clinically reliable images with less artifacts for an improved depiction of the cranio-cervical venous vessels.

Methods

Starting from the product sequence, the 3D PCV protocol was optimized in eight steps with respect to the velocity encoding (Venc) direction and value, slice thickness, reduction of susceptibility artifacts and arterial contamination, gradient mode and radio-frequency (RF)-spoiling, B0-Shimming, asymmetric echo technique and RF-pulse type, and flip angle. The product and optimized protocol was used to perform 3D PCV in 12 healthy male volunteers with a median age of 50 years using a state-of-the-art 1.5-T MR system. For evaluation, the cranio-cervical venous system was divided into 15 segments. These segments were evaluated by three radiologists with experience in neuroradiology. An ordinal scoring system was used to access the overall diagnostic quality, arterial contamination, and the quality of visualization.

Results

Image quality in the optimized 3D PCV was graded as “excellent” by all readers in 65.3% of the cases (p < 0.0001). The visualization of venous segments was strongly improved: it was considered diagnostic in 81.8% of all cases using the optimized sequence and in 47.6% for the product 3D PCV (p < 0.0001), respectively. The optimized protocol improved the imaging of all venous segments (p < 0.0001).

Conclusion

The optimized 3D PCV pulse sequence showed superior results compared to the product 3D PCV for the visualization and evaluation of the venous system in all healthy volunteers.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Friedman DI, Liu GT, Digre KB (2013) Revised diagnostic criteria for the pseudotumor cerebri syndrome in adults and children. Neurology 81:1159–1165CrossRefPubMed Friedman DI, Liu GT, Digre KB (2013) Revised diagnostic criteria for the pseudotumor cerebri syndrome in adults and children. Neurology 81:1159–1165CrossRefPubMed
3.
Zurück zum Zitat Baryshnik DB, Farb RI (2004) Changes in the appearance of venous sinuses after treatment of disordered intracranial pressure. Neurology 62:1445–1446CrossRefPubMed Baryshnik DB, Farb RI (2004) Changes in the appearance of venous sinuses after treatment of disordered intracranial pressure. Neurology 62:1445–1446CrossRefPubMed
4.
Zurück zum Zitat Rohr A, Bindeballe J, Riedel C, van Baalen A, Bartsch T, Doerner L, Jansen O (2012) The entire dural sinus tree is compressed in patients with idiopathic intracranial hypertension: a longitudinal, volumetric magnetic resonance imaging study. Neuroradiology 54:25–33CrossRefPubMed Rohr A, Bindeballe J, Riedel C, van Baalen A, Bartsch T, Doerner L, Jansen O (2012) The entire dural sinus tree is compressed in patients with idiopathic intracranial hypertension: a longitudinal, volumetric magnetic resonance imaging study. Neuroradiology 54:25–33CrossRefPubMed
5.
Zurück zum Zitat Bousser M-G, Ferro JM (2007) Cerebral venous thrombosis: an update. Lancet Neurol 6:162–170CrossRefPubMed Bousser M-G, Ferro JM (2007) Cerebral venous thrombosis: an update. Lancet Neurol 6:162–170CrossRefPubMed
6.
Zurück zum Zitat Ferro JM, Canhao P, Stam J, Bousser M-G, Barinagarrementeria F (2004) Prognosis of cerebral vein and dural sinus thrombosis: results of the international study on cerebral vein and dural sinus thrombosis (ISCVT). Stroke 35:664–670CrossRefPubMed Ferro JM, Canhao P, Stam J, Bousser M-G, Barinagarrementeria F (2004) Prognosis of cerebral vein and dural sinus thrombosis: results of the international study on cerebral vein and dural sinus thrombosis (ISCVT). Stroke 35:664–670CrossRefPubMed
7.
Zurück zum Zitat Lee S-K, terBrugge KG (2003) Cerebral venous thrombosis in adults: the role of imaging evaluation and management. Neuroimaging Clin N Am 13:139–152CrossRefPubMed Lee S-K, terBrugge KG (2003) Cerebral venous thrombosis in adults: the role of imaging evaluation and management. Neuroimaging Clin N Am 13:139–152CrossRefPubMed
8.
Zurück zum Zitat Kanda T, Nakai Y, Oba H, Toyoda K, Kitajima K, Furui S (2016) Gadolinium deposition in the brain. Magn Reson Imaging 34:1346–1350CrossRefPubMed Kanda T, Nakai Y, Oba H, Toyoda K, Kitajima K, Furui S (2016) Gadolinium deposition in the brain. Magn Reson Imaging 34:1346–1350CrossRefPubMed
9.
Zurück zum Zitat Kim M-H, Lee S-Y, Lee S-E, Yang M-S, Jung J-W, Park CM, Lee W, Cho SH, Kang HR (2014) Anaphylaxis to iodinated contrast media: clinical characteristics related with development of anaphylactic shock. PLoS One 9:e100154CrossRefPubMedPubMedCentral Kim M-H, Lee S-Y, Lee S-E, Yang M-S, Jung J-W, Park CM, Lee W, Cho SH, Kang HR (2014) Anaphylaxis to iodinated contrast media: clinical characteristics related with development of anaphylactic shock. PLoS One 9:e100154CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Ozturk K, Soylu E, Parlak M (2018) Dural venous sinus thrombosis: the combination of noncontrast CT, MRI and PC-MR venography to enhance accuracy. Neuroradiol J 31:473–481CrossRefPubMed Ozturk K, Soylu E, Parlak M (2018) Dural venous sinus thrombosis: the combination of noncontrast CT, MRI and PC-MR venography to enhance accuracy. Neuroradiol J 31:473–481CrossRefPubMed
11.
Zurück zum Zitat Ko SB, Kim D-E, Kim SH, Roh J-K (2006) Visualization of venous systems by time-of-flight magnetic resonance angiography. J Neuroimaging 16:353–356CrossRefPubMed Ko SB, Kim D-E, Kim SH, Roh J-K (2006) Visualization of venous systems by time-of-flight magnetic resonance angiography. J Neuroimaging 16:353–356CrossRefPubMed
12.
Zurück zum Zitat Leach JL, Strub WM, Gaskill-Shipley MF (2007) Cerebral venous thrombus signal intensity and susceptibility effects on gradient recalled-echo MR imaging. AJNR Am J Neuroradiol 28:940–945PubMed Leach JL, Strub WM, Gaskill-Shipley MF (2007) Cerebral venous thrombus signal intensity and susceptibility effects on gradient recalled-echo MR imaging. AJNR Am J Neuroradiol 28:940–945PubMed
13.
Zurück zum Zitat Axel L, Morton D (1987) MR flow imaging by velocity-compensated/uncompensated difference images. J Comput Assist Tomogr 11:31–34CrossRefPubMed Axel L, Morton D (1987) MR flow imaging by velocity-compensated/uncompensated difference images. J Comput Assist Tomogr 11:31–34CrossRefPubMed
14.
Zurück zum Zitat Liauw L, van Buchem MA, Spilt A, de Bruine FT, van den Berg R, Hermans J, Wasser MN (2000) MR angiography of the intracranial venous system. Radiology 214:678–682CrossRefPubMed Liauw L, van Buchem MA, Spilt A, de Bruine FT, van den Berg R, Hermans J, Wasser MN (2000) MR angiography of the intracranial venous system. Radiology 214:678–682CrossRefPubMed
15.
Zurück zum Zitat Campeau N, Patton A (2013) Inhance 3D phase contrast angiographic magnetic resonance venography of the brain: initial clinical experience in 23 patients. Proc Int Mag Reson Med 21 Campeau N, Patton A (2013) Inhance 3D phase contrast angiographic magnetic resonance venography of the brain: initial clinical experience in 23 patients. Proc Int Mag Reson Med 21
17.
Zurück zum Zitat Dumoulin CL, Hart HR Jr (1986) Magnetic resonance angiography in the head and neck. Acta Radiol Suppl 369:17–20PubMed Dumoulin CL, Hart HR Jr (1986) Magnetic resonance angiography in the head and neck. Acta Radiol Suppl 369:17–20PubMed
18.
Zurück zum Zitat Hausmann R, Lewin JS, Laub G (1991) Phase-contrast MR angiography with reduced acquisition time: new concepts in sequence design. J Magn Reson Imaging 1:415–422CrossRefPubMed Hausmann R, Lewin JS, Laub G (1991) Phase-contrast MR angiography with reduced acquisition time: new concepts in sequence design. J Magn Reson Imaging 1:415–422CrossRefPubMed
19.
Zurück zum Zitat Wilen J, Hauksson J, Mild KH (2010) Modification of pulse sequences reduces occupational exposure from MRI switched gradient fields: preliminary results. Bioelectromagnetics 31:85–87CrossRefPubMed Wilen J, Hauksson J, Mild KH (2010) Modification of pulse sequences reduces occupational exposure from MRI switched gradient fields: preliminary results. Bioelectromagnetics 31:85–87CrossRefPubMed
20.
Zurück zum Zitat Tomasian A, Salamon N, Krishnam MS, Finn JP, Villablanca JP (2009) 3D high-spatial-resolution cerebral MR venography at 3T: a contrast-dose-reduction study. AJNR Am J Neuroradiol 30:349–355CrossRefPubMed Tomasian A, Salamon N, Krishnam MS, Finn JP, Villablanca JP (2009) 3D high-spatial-resolution cerebral MR venography at 3T: a contrast-dose-reduction study. AJNR Am J Neuroradiol 30:349–355CrossRefPubMed
21.
Zurück zum Zitat Zuehlsdorff S, Giri S, Edelman RR (2017) Shimming method for magnetic resonance imaging (patent number 20170123027). Siemens Medical Solutions USA, Inc. (Malvern, PA, US), NorthShore University, HealthSystem Research Institute (Evanston, IL, US) Zuehlsdorff S, Giri S, Edelman RR (2017) Shimming method for magnetic resonance imaging (patent number 20170123027). Siemens Medical Solutions USA, Inc. (Malvern, PA, US), NorthShore University, HealthSystem Research Institute (Evanston, IL, US)
22.
Zurück zum Zitat McGibney G, Smith MR, Nichols ST, Crawley A (1993) Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn Reson Med 30:51–59CrossRefPubMed McGibney G, Smith MR, Nichols ST, Crawley A (1993) Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn Reson Med 30:51–59CrossRefPubMed
23.
Zurück zum Zitat Nael K, Fenchel M, Salamon N, Duckwiler GR, Laub G, Finn JP, Villablanca JP (2006) Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla: initial results using highly accelerated parallel acquisition. Investig Radiol 41:763–768CrossRef Nael K, Fenchel M, Salamon N, Duckwiler GR, Laub G, Finn JP, Villablanca JP (2006) Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla: initial results using highly accelerated parallel acquisition. Investig Radiol 41:763–768CrossRef
24.
Zurück zum Zitat Krayenbühl H, Yasargil MG (1979) Zerebrale Angiographie für Klinik und Praxis: Thieme Krayenbühl H, Yasargil MG (1979) Zerebrale Angiographie für Klinik und Praxis: Thieme
25.
Zurück zum Zitat Marasini D, Quatto P, Ripamonti E (2014) Assessing the inter-rater agreement for ordinal data through weighted indexes. Stat Methods Med Res 25:2611–2633CrossRefPubMed Marasini D, Quatto P, Ripamonti E (2014) Assessing the inter-rater agreement for ordinal data through weighted indexes. Stat Methods Med Res 25:2611–2633CrossRefPubMed
26.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
27.
Zurück zum Zitat Kanda T, Ishii K, Kawaguchi H, Kitajima K, Takenaka D (2014) High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: relationship with increasing cumulative dose of a gadolinium-based contrast material. Radiology 270:834–841CrossRefPubMed Kanda T, Ishii K, Kawaguchi H, Kitajima K, Takenaka D (2014) High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: relationship with increasing cumulative dose of a gadolinium-based contrast material. Radiology 270:834–841CrossRefPubMed
28.
Zurück zum Zitat Mimura S, Iwata N, Yamane T, Hirata Y, Tanino F, Sugihara S et al (2003) Report on the ECR2003 (European congress of radiology): non-contrast intracranial MR venography with 3D-phase contrast imaging: optimization of presaturation pulse and velocity encoding. Nihon Hoshasen Gijutsu Gakkai Zasshi 59:823–824CrossRefPubMed Mimura S, Iwata N, Yamane T, Hirata Y, Tanino F, Sugihara S et al (2003) Report on the ECR2003 (European congress of radiology): non-contrast intracranial MR venography with 3D-phase contrast imaging: optimization of presaturation pulse and velocity encoding. Nihon Hoshasen Gijutsu Gakkai Zasshi 59:823–824CrossRefPubMed
29.
Zurück zum Zitat Markl M, Bammer R, Alley MT, Elkins CJ, Draney MT, Barnett A, Moseley ME, Glover GH, Pelc NJ (2003) Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions. Magn Reson Med 50:791–801CrossRefPubMed Markl M, Bammer R, Alley MT, Elkins CJ, Draney MT, Barnett A, Moseley ME, Glover GH, Pelc NJ (2003) Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions. Magn Reson Med 50:791–801CrossRefPubMed
30.
Zurück zum Zitat Johnson KM, Lum DP, Turski PA, Block WF, Mistretta CA, Wieben O (2008) Improved 3D phase contrast MRI with off-resonance corrected dual echo VIPR. Magn Reson Med 60:1329–1336CrossRefPubMedPubMedCentral Johnson KM, Lum DP, Turski PA, Block WF, Mistretta CA, Wieben O (2008) Improved 3D phase contrast MRI with off-resonance corrected dual echo VIPR. Magn Reson Med 60:1329–1336CrossRefPubMedPubMedCentral
31.
Zurück zum Zitat Baker MA (2013) Reduction of MRI acoustic noise achieved by manipulation of scan parameters – a study using veterinary MR sequences. Radiography 19:11–16CrossRef Baker MA (2013) Reduction of MRI acoustic noise achieved by manipulation of scan parameters – a study using veterinary MR sequences. Radiography 19:11–16CrossRef
32.
Zurück zum Zitat Zhang X, Petersen ET, Ghariq E, de Vis JB, Webb AG, Teeuwisse WM et al (2013) In vivo blood T(1) measurements at 1.5 T, 3 T, and 7 T. Magn Reson Med 70:1082–1086CrossRefPubMed Zhang X, Petersen ET, Ghariq E, de Vis JB, Webb AG, Teeuwisse WM et al (2013) In vivo blood T(1) measurements at 1.5 T, 3 T, and 7 T. Magn Reson Med 70:1082–1086CrossRefPubMed
Metadaten
Titel
Optimization of 3D phase contrast venography for the assessment of the cranio-cervical venous system at 1.5 T
verfasst von
Mona Salehi Ravesh
Ulf Jensen-Kondering
Julia Juhasz
Sönke Peters
Monika Huhndorf
Joachim Graessner
Thomas W. D. Möbius
Marcus Both
Olav Jansen
Jan-Bernd Hövener
Publikationsdatum
04.01.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Neuroradiology / Ausgabe 3/2019
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-018-2146-6

Weitere Artikel der Ausgabe 3/2019

Neuroradiology 3/2019 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.