Skip to main content
main-content

19.09.2020 | Original Article | Ausgabe 12/2020 Open Access

Pediatric Radiology 12/2020

Outpacing movement — ultrafast volume coverage in neuropediatric magnetic resonance imaging

Zeitschrift:
Pediatric Radiology > Ausgabe 12/2020
Autoren:
Daniel Gräfe, Christian Roth, Margit Weisser, Matthias Krause, Jens Frahm, Dirk Voit, Franz Wolfgang Hirsch
Wichtige Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s00247-020-04771-5) contains supplementary material, which is available to authorized users.

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Abstract

Background

Conventional MRI sequences are often affected in neuropediatric imaging by unavoidable movements. Therefore, children younger than 6 years usually have to be examined under sedation/anesthesia. A new real-time MRI technique with automatic slice advancement allows for motion-robust T2-weighted volume coverage of the whole brain within a few seconds in adults.

Objective

To evaluate to which extent the new volume coverage method can be used to visualize cerebrospinal fluid and reduce the need for anesthesia in children.

Materials and methods

We assessed 30 children ages 6 years and younger with suspected or proven hydrocephalus, hygroma or macrocephalus using volume coverage sequences with 20 slices per second in three planes. If necessary, a parent was placed in the bore together with the child for calming and gentle immobilization. We compared visualization of cerebrospinal fluid spaces and course of the shunt catheter in volume coverage sequences vs. fast spin-echo sequences.

Results

The clinical issue could be sufficiently assessed in all children with use of volume coverage sequences, whereas conventional fast spin-echo sequences performed moderately to poorly. Visualization of the tip of a shunt failed in 16% of volume coverage scans and 27% of turbo spin-echo scans. A subsequent examination under anesthesia was never necessary. None of the examinations had to be stopped prematurely.

Conclusion

The motion-robust volume coverage sequences with T2-type contrast can be used to avoid sedation of children in the evaluation of cerebrospinal fluid spaces, even in the presence of vigorous motion. For other indications and contrasts, the technique must still be evaluated.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag als Mediziner

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Alle e.Med Abos bis 30. April 2021 zum halben Preis!

Jetzt e.Med zum Sonderpreis bestellen!

e.Med Pädiatrie

Kombi-Abonnement

Mit e.Med Pädiatrie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Pädiatrie, den Premium-Inhalten der pädiatrischen Fachzeitschriften, inklusive einer gedruckten Pädiatrie-Zeitschrift Ihrer Wahl.

Alle e.Med Abos bis 30. April 2021 zum halben Preis!

Jetzt e.Med zum Sonderpreis bestellen!

e.Med Radiologie

Kombi-Abonnement

Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.

Alle e.Med Abos bis 30. April 2021 zum halben Preis!

Jetzt e.Med zum Sonderpreis bestellen!

Zusatzmaterial
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 12/2020

Pediatric Radiology 12/2020 Zur Ausgabe

Minisymposium: Imaging of skeletal dysplasia

Genetics for paediatric radiologists

Minisymposium: Imaging of skeletal dysplasia

Neuroimaging and calvarial findings in achondroplasia

Neu im Fachgebiet Radiologie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Radiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise