Skip to main content
Erschienen in: Radiological Physics and Technology 2/2018

04.04.2018

Output factor determination based on Monte Carlo simulation for small cone field in 10-MV photon beam

verfasst von: Kyohei Fukata, Satoru Sugimoto, Chie Kurokawa, Akito Saito, Tatsuya Inoue, Keisuke Sasai

Erschienen in: Radiological Physics and Technology | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

The difficulty of measuring output factor (OPF) in a small field has been frequently discussed in recent publications. This study is aimed to determine the OPF in a small field using 10-MV photon beam and stereotactic conical collimator (cone). The OPF was measured by two diode detectors (SFD, EDGE detector) and one micro-ion chamber (PinPoint 3D chamber) in a water phantom. A Monte Carlo simulation using simplified detector model was performed to obtain the correction factor for the detector measurements. About 12% OPF difference was observed in the measurement at the smallest field (7.5 mm diameter) for EDGE detector and PinPoint 3D chamber. By applying the Monte Carlo-based correction factor to the measurement, the maximum discrepancy among the three detectors was reduced to within 3%. The results indicate that determination of OPF in a small field should be carefully performed. Especially, detector choice and appropriate correction factor application are very important in this regard.
Literatur
1.
Zurück zum Zitat Schell MC, Bova FJ, Larson DA, Leavitt DD, Lutz WR, Podgorsak EB, Wu A (1995) Stereotactic Radiosurgery Report of Task Group 42 Radiation Therapy Committee. Oncol 54:. Schell MC, Bova FJ, Larson DA, Leavitt DD, Lutz WR, Podgorsak EB, Wu A (1995) Stereotactic Radiosurgery Report of Task Group 42 Radiation Therapy Committee. Oncol 54:.
3.
Zurück zum Zitat Benedict SH, Yenice KM, Followill D, Galvin JM, Hinson W, Kavanagh B, Keall P, Lovelock M, Meeks S, Papiez L, Purdie T, Sadagopan R, Schell MC, Salter B, Schlesinger DJ, Shiu AS, Solberg T, Song DY, Stieber V, Timmerman R, Tomé WA, Verellen D, Wang L, Yin F-F, Tomé WA, Verellen D, Wang L, Yin F-F. Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys. 2010;37:4078–101. https://doi.org/10.1118/1.3438081.CrossRefPubMed Benedict SH, Yenice KM, Followill D, Galvin JM, Hinson W, Kavanagh B, Keall P, Lovelock M, Meeks S, Papiez L, Purdie T, Sadagopan R, Schell MC, Salter B, Schlesinger DJ, Shiu AS, Solberg T, Song DY, Stieber V, Timmerman R, Tomé WA, Verellen D, Wang L, Yin F-F, Tomé WA, Verellen D, Wang L, Yin F-F. Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys. 2010;37:4078–101. https://​doi.​org/​10.​1118/​1.​3438081.CrossRefPubMed
8.
24.
Zurück zum Zitat Kawrakow I, Rogers DWO. The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport, NRCC Report PIRS-701, 2000. Kawrakow I, Rogers DWO. The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport, NRCC Report PIRS-701, 2000.
25.
Zurück zum Zitat Rogers DWO, Walters B, Kawrakow I. BEAMnrc Users Manual, NRCC Report PIRS-0509. Stand: Ioniz Radiat; 2005. Rogers DWO, Walters B, Kawrakow I. BEAMnrc Users Manual, NRCC Report PIRS-0509. Stand: Ioniz Radiat; 2005.
28.
Zurück zum Zitat Hirayama H, Namito Y, Bielajew AF, Wilderman SJ, Nelson WR (2005) The EGS5 Code System, SLAC-Report-730 and KEK Report 2005-8. SLAC National Accelerator Laboratory and High Energy Accelerator Research Organization. Hirayama H, Namito Y, Bielajew AF, Wilderman SJ, Nelson WR (2005) The EGS5 Code System, SLAC-Report-730 and KEK Report 2005-8. SLAC National Accelerator Laboratory and High Energy Accelerator Research Organization.
29.
Zurück zum Zitat ICRU Report No.37 Stopping powers for electrons and positrons. In: International Commission on Radiation Units and Measurements. Washington ICRU Report No.37 Stopping powers for electrons and positrons. In: International Commission on Radiation Units and Measurements. Washington
30.
Zurück zum Zitat Mainegra-Hing E (2017) User Manual for egs inprz, a GUI for the NRC RZ user-codes. NRCC Rep PIRS-801(RevB) 801:1–35. Mainegra-Hing E (2017) User Manual for egs inprz, a GUI for the NRC RZ user-codes. NRCC Rep PIRS-801(RevB) 801:1–35.
33.
Zurück zum Zitat Martens C, De Wagter C, De Neve W. The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy. Phys Med Biol. 2000;45:2519–30.CrossRefPubMed Martens C, De Wagter C, De Neve W. The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy. Phys Med Biol. 2000;45:2519–30.CrossRefPubMed
37.
Zurück zum Zitat Bassinet C, Huet C, Derreumaux S, Brunet G, Chéa M, Baumann M, Lacornerie T, Gaudaire-Josset S, Trompier F, Roch P, Boisserie G, Clairand I. Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones. Med Phys. 2013;40:71725. https://doi.org/10.1118/1.4811139.CrossRef Bassinet C, Huet C, Derreumaux S, Brunet G, Chéa M, Baumann M, Lacornerie T, Gaudaire-Josset S, Trompier F, Roch P, Boisserie G, Clairand I. Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones. Med Phys. 2013;40:71725. https://​doi.​org/​10.​1118/​1.​4811139.CrossRef
39.
Zurück zum Zitat Park K, Bak J, Park S, Choi W, Park SW. Determination of small-field correction factors for cylindrical ionization chambers using a semiempirical method. Phys Med Biol. 2016;61:1293–308.CrossRefPubMed Park K, Bak J, Park S, Choi W, Park SW. Determination of small-field correction factors for cylindrical ionization chambers using a semiempirical method. Phys Med Biol. 2016;61:1293–308.CrossRefPubMed
Metadaten
Titel
Output factor determination based on Monte Carlo simulation for small cone field in 10-MV photon beam
verfasst von
Kyohei Fukata
Satoru Sugimoto
Chie Kurokawa
Akito Saito
Tatsuya Inoue
Keisuke Sasai
Publikationsdatum
04.04.2018
Verlag
Springer Singapore
Erschienen in
Radiological Physics and Technology / Ausgabe 2/2018
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-018-0455-4

Weitere Artikel der Ausgabe 2/2018

Radiological Physics and Technology 2/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.