Abstract

Purpose

Rotational alignment of prosthetic components after total knee arthroplasty (TKA) is predominantly monitored with computer tomography (CT), for example by relating the anatomical transepicondylar axis (a-TEA) of the native femur to the posterior bicondylar axis of the prosthetic component (PBCA). The purpose of the present study was to portray a reliable, novel plain radiographic method that likewise enables the evaluation of rotational positioning of prosthetic components in TKA. Furthermore, it was intended to evaluate the prosthetic femoro-tibial functional behavior under loaded conditions.

Methods

Modified plain axial radiographs under partial weight bearing (20 kg) were performed in 63 patients (63 knees) after TKA. On the obtained radiographs, all established, relevant anatomic, and prosthetic axis and angles reflecting the rotational position of the femoral (i.e., a-TEA/PBCA angle) and tibial component were detected twice by two independent examiners with an interval of one month. Additionally, in 14 cases with anterior knee pain after surgery, radiographic results were compared to obtained computer tomography images; intraclass coefficients (ICC’s) for intra- and inter-rater reliability were calculated.

Results

All pre-assigned axis and angles could be identified doubtlessly by both examiners in all investigated knees. For all measurements, ICC’s for intra-rater and inter-rater reliability ranged from 0.75 to 0.96. The comparison of the radiographic measurements with corresponding CT results (n = 14) revealed no significant differences (p > 0.05). Rotational alignment of the tibial tray in relation to the native tibial bone was not measurable due to display overlaying. Femoro-tibial behaviour of the prosthetic components under partial loading showed a high variability.

Conclusion

We were able to establish a new reliable radiographic technique that is able to show the most established and relevant anatomic landmarks and prosthetic axis after TKA to assess the rotational alignment of the prosthetic components in TKA in relation to the distal femur. The evaluation of the femoro-tibal behaviour instead shows a high variability and so far does not allow valid explanatory conclusions.
Literatur
1.
Zurück zum Zitat Noble PC, Gordon MJ, Weiss JM, Reddix RN, Conditt MA, Mathis KB (2005) Does total knee replacement retsore normal knee function. Clin Orthop Relat Res 431:157–165CrossRef Noble PC, Gordon MJ, Weiss JM, Reddix RN, Conditt MA, Mathis KB (2005) Does total knee replacement retsore normal knee function. Clin Orthop Relat Res 431:157–165CrossRef
2.
Zurück zum Zitat Petersen W, Rembitzki IV, Brüggemann GP, Ellermann A, Best R, Koppenburg AG, Liebau C (2014) Anterior knee pain after total knee arthroplasty: a narrative review. Int Orthop 38(2):319–328CrossRefPubMed Petersen W, Rembitzki IV, Brüggemann GP, Ellermann A, Best R, Koppenburg AG, Liebau C (2014) Anterior knee pain after total knee arthroplasty: a narrative review. Int Orthop 38(2):319–328CrossRefPubMed
3.
Zurück zum Zitat Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L (2001) Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res 392:46–55CrossRef Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L (2001) Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res 392:46–55CrossRef
4.
Zurück zum Zitat Michalik R, Rath B, Springorum HR, Luering C, Tingart M (2016) Anterior knee pain after total knee arthroplasty: causes diagnosis and treatment. Orthopaede, Apr 28 Michalik R, Rath B, Springorum HR, Luering C, Tingart M (2016) Anterior knee pain after total knee arthroplasty: causes diagnosis and treatment. Orthopaede, Apr 28
5.
Zurück zum Zitat Armstrong AD, Brien HJ, Dunning CE, King GJ, Johnson JA, Chess DG (2003) Patellar position after total knee arthroplasty: Influence of femoral component malposition. J Arthroplasty 18(4):458–465CrossRefPubMed Armstrong AD, Brien HJ, Dunning CE, King GJ, Johnson JA, Chess DG (2003) Patellar position after total knee arthroplasty: Influence of femoral component malposition. J Arthroplasty 18(4):458–465CrossRefPubMed
6.
Zurück zum Zitat Matsuzaki T, Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kawakami Y, Ishida K, Oka S, Kuroda R, Kurosaka M (2013) Kinematic factors affecting postoperative knee flexion after cruciate-retaining total knee arthroplasty. Int Orthop 37(5):803–808CrossRefPubMedPubMedCentral Matsuzaki T, Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kawakami Y, Ishida K, Oka S, Kuroda R, Kurosaka M (2013) Kinematic factors affecting postoperative knee flexion after cruciate-retaining total knee arthroplasty. Int Orthop 37(5):803–808CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Savin L, Botez P, Mihailescu D, Predescu V, Grierosu C (2016) Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty. Int Orthop, 2016 Jan 23 Savin L, Botez P, Mihailescu D, Predescu V, Grierosu C (2016) Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty. Int Orthop, 2016 Jan 23
8.
Zurück zum Zitat Konno T, Onodera T, Nishio Y, Kasahara Y, Iwasaki N, Majima T (2014) Correlation between knee kinematics and patellofemoral contact pressure in total knee arthroplasty. J Arthroplasty 29(12):2305–2308CrossRefPubMed Konno T, Onodera T, Nishio Y, Kasahara Y, Iwasaki N, Majima T (2014) Correlation between knee kinematics and patellofemoral contact pressure in total knee arthroplasty. J Arthroplasty 29(12):2305–2308CrossRefPubMed
9.
Zurück zum Zitat Jilani A, Shirazi-Adl A, Bendjaballah M (1997) Biomechanics of human tibio-femoral joint in axial rotation. Knee 19:203–213CrossRef Jilani A, Shirazi-Adl A, Bendjaballah M (1997) Biomechanics of human tibio-femoral joint in axial rotation. Knee 19:203–213CrossRef
10.
Zurück zum Zitat Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, Freeman MA (2004) Does the femur roll-back with flexion? J Bone Joint Surg (Br) 86(6):925–931CrossRef Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, Freeman MA (2004) Does the femur roll-back with flexion? J Bone Joint Surg (Br) 86(6):925–931CrossRef
11.
Zurück zum Zitat Churchill D, Incavo SJ, Johnson CC, Beynnon DD (2001) The influence of femoral rollback on patellofemoral contact loads in total knee arthroplasty. J Arthroplasty 16(7):909–918CrossRefPubMed Churchill D, Incavo SJ, Johnson CC, Beynnon DD (2001) The influence of femoral rollback on patellofemoral contact loads in total knee arthroplasty. J Arthroplasty 16(7):909–918CrossRefPubMed
12.
Zurück zum Zitat Freeman MA, Pinskerova V (2003) The movement of the knee studied by magnetic resonance imaging. Clin Orthop Relat Res 410:35–43CrossRef Freeman MA, Pinskerova V (2003) The movement of the knee studied by magnetic resonance imaging. Clin Orthop Relat Res 410:35–43CrossRef
13.
Zurück zum Zitat Johal P, Williams A, Wragg P, Hunt D, Gedroyc W (2005) Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using ‘interventional’ MRI. J Biomech 38(2):269–276CrossRefPubMed Johal P, Williams A, Wragg P, Hunt D, Gedroyc W (2005) Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using ‘interventional’ MRI. J Biomech 38(2):269–276CrossRefPubMed
14.
Zurück zum Zitat Anouchi YS, Whiteside LA, Kaiser AD, Milliano MT (1993) The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens. Clin Orthop Relat Res 287:170–177 Anouchi YS, Whiteside LA, Kaiser AD, Milliano MT (1993) The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens. Clin Orthop Relat Res 287:170–177
15.
Zurück zum Zitat Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRef Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRef
16.
Zurück zum Zitat Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366:155–163CrossRef Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366:155–163CrossRef
17.
Zurück zum Zitat Eisenhuth SA, Saleh KJ, Cui Q, Clark CR, Brown TE (2006) Patellofemoral instability after total knee arthroplasty. Clin Orthop Relat Res 446:149–160CrossRefPubMed Eisenhuth SA, Saleh KJ, Cui Q, Clark CR, Brown TE (2006) Patellofemoral instability after total knee arthroplasty. Clin Orthop Relat Res 446:149–160CrossRefPubMed
18.
Zurück zum Zitat Briard JL, Hungerford DS (1989) Patellofemoral instability in total knee arthroplasty. J Arthroplasty 4(Suppl):S87–S97CrossRefPubMed Briard JL, Hungerford DS (1989) Patellofemoral instability in total knee arthroplasty. J Arthroplasty 4(Suppl):S87–S97CrossRefPubMed
19.
Zurück zum Zitat Asano T, Akagi M, Koike K, Nakamura T (2003) Clin Orthop Relat Res 413:222–232CrossRef Asano T, Akagi M, Koike K, Nakamura T (2003) Clin Orthop Relat Res 413:222–232CrossRef
20.
Zurück zum Zitat Abadie P, Galaud B, Michaut M, Fallet L, Boisrenoult P, Beaufils P (2009) Distal femur rotational alignment and patellar subluxation: a CT scan in vivo assessment. Orthop Traumatol Surg Res 95(4):267–271CrossRefPubMed Abadie P, Galaud B, Michaut M, Fallet L, Boisrenoult P, Beaufils P (2009) Distal femur rotational alignment and patellar subluxation: a CT scan in vivo assessment. Orthop Traumatol Surg Res 95(4):267–271CrossRefPubMed
21.
Zurück zum Zitat Berhouet J, Beaufils P, Boisrenoult P, Frasca D, Pujol N (2011) Rotational positioning of the tibial tray in total knee arthroplasty: a CT evaluation. Orthop Traumatol Surg Res 97(7):699–704CrossRefPubMed Berhouet J, Beaufils P, Boisrenoult P, Frasca D, Pujol N (2011) Rotational positioning of the tibial tray in total knee arthroplasty: a CT evaluation. Orthop Traumatol Surg Res 97(7):699–704CrossRefPubMed
22.
Zurück zum Zitat Ikeuchi M, Yamanaka N, Okanoue Y, Ueta E, Tani T (2007) Determining the rotational alignment of the tibial component at total knee replacement. J Bone Joint Surg (Br) 89:45–49CrossRef Ikeuchi M, Yamanaka N, Okanoue Y, Ueta E, Tani T (2007) Determining the rotational alignment of the tibial component at total knee replacement. J Bone Joint Surg (Br) 89:45–49CrossRef
23.
Zurück zum Zitat Viel T, Casin S, Ducellier F, Setiger V, Bigorre N, Bizot P (2013) Is radiographic measurement of distal femoral torsion reliable. Orthop Traumatol Surg Res 99:517–522CrossRefPubMed Viel T, Casin S, Ducellier F, Setiger V, Bigorre N, Bizot P (2013) Is radiographic measurement of distal femoral torsion reliable. Orthop Traumatol Surg Res 99:517–522CrossRefPubMed
24.
Zurück zum Zitat Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197CrossRef Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197CrossRef
25.
Zurück zum Zitat Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg (Br) 93(5):629–633CrossRef Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg (Br) 93(5):629–633CrossRef
26.
Zurück zum Zitat Victor J, Van Doninck D, Labey L, Van Glabbeek F, Parizel P, Bellemans J (2009) A common reference frame for describing rotation of the distal femur. A CT-based kinematic study unsing cadavers. J Bone Joint Surg (Br) 91:683–690CrossRef Victor J, Van Doninck D, Labey L, Van Glabbeek F, Parizel P, Bellemans J (2009) A common reference frame for describing rotation of the distal femur. A CT-based kinematic study unsing cadavers. J Bone Joint Surg (Br) 91:683–690CrossRef
27.
Zurück zum Zitat Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95(5):365–372CrossRefPubMed Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95(5):365–372CrossRefPubMed
28.
Zurück zum Zitat Takai S, Yoshino N, Isshiki T, Hirasawa Y (2003) Kneeling view: new roentgenographic technique to assess rotational deformity and alignment of the distal femur. J Arthroplasty 18:478–483CrossRefPubMed Takai S, Yoshino N, Isshiki T, Hirasawa Y (2003) Kneeling view: new roentgenographic technique to assess rotational deformity and alignment of the distal femur. J Arthroplasty 18:478–483CrossRefPubMed
29.
Zurück zum Zitat Laurin C, Dussault R (1979) The tangential x-ray investigation of the patellofemoral joint: x-ray technique, diagnostic criteria and their interpretation. Clin Orthop Relat Res 144:16–26 Laurin C, Dussault R (1979) The tangential x-ray investigation of the patellofemoral joint: x-ray technique, diagnostic criteria and their interpretation. Clin Orthop Relat Res 144:16–26
30.
Zurück zum Zitat Knutson F (1941) Ueber die rontgenologie des femoropatellargelenkes sowie eine gute Projektion fur das Kniegelenk. Acta Radiol 22:371–376CrossRef Knutson F (1941) Ueber die rontgenologie des femoropatellargelenkes sowie eine gute Projektion fur das Kniegelenk. Acta Radiol 22:371–376CrossRef
31.
Zurück zum Zitat Berger R, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47 Berger R, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47
32.
Zurück zum Zitat Saramah SS, Patel S, Hossain FS, Haddad FS (2012) The radiological assessment of total and unicompartmental knee replacements. J Bone Joint Surg (Br) 94(10):1321–1329CrossRef Saramah SS, Patel S, Hossain FS, Haddad FS (2012) The radiological assessment of total and unicompartmental knee replacements. J Bone Joint Surg (Br) 94(10):1321–1329CrossRef
33.
Zurück zum Zitat Koike M, Nose H, Takagi S, Akimoto A, Kaji T (2015) A skyline-view imaging technique for axial projection of the patella: a clinical study. Radiol Phys Technol 8(2):174–177CrossRefPubMed Koike M, Nose H, Takagi S, Akimoto A, Kaji T (2015) A skyline-view imaging technique for axial projection of the patella: a clinical study. Radiol Phys Technol 8(2):174–177CrossRefPubMed
Metadaten
Titel
Partially loaded plain radiographic measurement to evaluate rotational alignment in total knee arthroplasty
verfasst von
William Pedraza
Johannes Beckmann
Constantin Mayer
Frieder Mauch
Jochen Huth
Raymond Best
Publikationsdatum
22.07.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 12/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3247-7

Weitere Artikel der Ausgabe 12/2016

International Orthopaedics 12/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.