An 88-year-old woman with a history of rheumatoid arthritis was hospitalized for acute heart failure (HF). Transthoracic echocardiography revealed severe mitral regurgitation (MR) due to P2 prolapse, and acute chordae rupture was suspected. The mitral valve annulus was severely calcified, and the mitral valve area was 2.62 cm2 by 2D planimetry. HF management was difficult despite the administration of high doses of dobutamine and diuretics. Transcatheter edge-to-edge repair was considered because of the high surgical risk. Transesophageal echocardiography (TEE) confirmed severe MR with chordae rupture of P2 (Fig. 1A, B). The posterior leaflet length at the grasping zone was 8.2 mm. Mitral annular calcification was concentric at the basal posterior leaflet (Fig. 1C). Because the MitraClip device (Abbott Vascular Inc., CA) has a rigid cobalt–chrome clip, leading to a risk of leaflet tear and mitral stenosis, a PASCAL Ace device (Edwards Lifesciences, CA) with a flexible nitinol implant and spacer was selected expecting minimal tension against the leaflets. After transseptal puncture, the posterior leaflet was grasped using the PASCAL implant while avoiding the calcified annulus (Fig. 1D); however, MR did not reduce after implant closure (Fig. 1E). The implant’s position was then adjusted to cover the entire posterior leaflet with the calcified annulus, and the posterior clasp was dropped down after grasping the anterior leaflet (Fig. 1F). After implant closure, TEE showed mild MR from lateral indentation (Fig. 1G) and the acceptable transmitral mean pressure gradient (TMPG) of 5 mmHg. The paddles were moving with the heartbeat (Video). After releasing the device, MR did not change, with TMPG of 3 mmHg (Fig. 1H, I). A small calcified mitral valve is unsuitable for TEER. The PASCAL device helps minimize leaflet stress and preserve the valve area [1]. In addition, the PASCAL Ace implant can engage the leaflets with minimal interaction with dense chordae structure. This case suggests the potential advantage of the PASCAL Ace device to avoid mitral stenosis and valve injury in severe MR with a small calcified valve.
×
…
Anzeige
Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten
Kommt es sehr früh nach einer kardiopulmonalen Reanimation zu einem Zustand der Hyperoxie, ist dies bei Patienten nach einem Herzstillstand mit schlechteren funktionellen Ergebnissen assoziiert. Das zeigt eine Sekundäranalyse der TTM-2-Studie.
Der Lp(a)-Wert kann dazu beitragen, bei stabilen Patienten mit neu aufgetretenen Thoraxschmerzen und ohne KHK-Diagnose die Wahrscheinlichkeit für das Vorliegen von Koronarstenosen abzuschätzen.
Der Mineralokortikoid-Rezeptor-Antagonist Finerenon verbessert die Prognose bei Herzinsuffizienz mit leicht reduzierter oder erhaltener Ejektionsfraktion. Ein Rückgang der eGFR zu Beginn der Therapie scheint diese Wirkung nicht wesentlich zu mindern.
Auch Personen mit kalt-trockener terminaler Herzinsuffizienz profitieren von einem linksventrikulären Unterstützungssystem (LVAD), wie Daten aus einem US-Register nahelegen. Doch es gibt Besonderheiten.
In diesem CME-Kurs können Sie Ihr Wissen zur EKG-Befundung anhand von zwölf Video-Tutorials auffrischen und 10 CME-Punkte sammeln. Praxisnah, relevant und mit vielen Tipps & Tricks vom Profi.