Skip to main content
Erschienen in: BMC Pulmonary Medicine 1/2017

Open Access 01.12.2017 | Research article

Patient preferences for dry powder inhaler attributes in asthma and chronic obstructive pulmonary disease in France: a discrete choice experiment

verfasst von: Natalia Hawken, Saku Torvinen, Mohamed-Elmoctar Neine, Ikbel Amri, Mondher Toumi, Samuel Aballéa, Adam Plich, Nicolas Roche

Erschienen in: BMC Pulmonary Medicine | Ausgabe 1/2017

Abstract

Background

Dry powder inhalers (DPIs) are often used in asthma and chronic obstructive pulmonary disease (COPD) therapies. Using the discrete choice experiment (DCE) methodology, this study conducted in France was designed to assess patients’ preferences for different attributes of DPIs.

Methods

Attributes of DPIs were defined based on a literature review, patient focus group discussions and interviews with healthcare professionals (qualitative phase of the study). An online survey was then conducted among French patients with asthma or COPD to elicit patient preferences and willingness to pay (WTP) for these attributes using the DCE methodology (quantitative phase). A fractional factorial design including three blocks of 12 choice sets was created. Each choice set comprised three alternatives: two fictitious inhalers and the patient’s current inhaler. Marginal utilities were estimated using a ranked ordered logit model. Interactions between attributes and disease (asthma or COPD) were tested.

Results

Six DPI attributes were defined based on the qualitative phase: ease of use/fool-proof priming; accurate and easy-to-read dose counter; dose confirmation; hygiene of the mouthpiece; flexibility of the device handling; ability to use the inhaler with breathing difficulties. Overall, 201 patients with asthma and 93 with COPD were included in the online survey. Patients with asthma placed most value on an inhaler that requires one step for dose preparation (WTP €4.83 [95% CI: €3.77–€5.90], relative to an inhaler requiring four steps) and one that could be used during episodes of breathing difficulties (WTP €4.49 [95% CI: €2.95–€6.02]). Patients with COPD placed most value on an inhaler that could be used during episodes of breathing difficulties (WTP €7.70 [95% CI: €5.65–€9.76]) and on the accuracy of the dose counter (WTP €5.87 [95% CI: €3.98–€ 7.77]).

Conclusion

This study suggests that asthma and COPD patients would be willing to change their inhaler if they were offered the option of a new inhaler with improved characteristics and they place a high value on an inhaler with ease of use during breathing difficulty episodes.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​s12890-017-0439-x) contains supplementary material, which is available to authorized users.
Abkürzungen
BA-MDI
Breath-actuated metered-dose inhalers
CI
Confidence interval
COPD
Chronic obstructive pulmonary disease
DCE
Discrete choice experiment
DPI
Dry powder inhaler
FrF
Fractional factorial
GINA
Global initiative for asthma
HUI3
Health utilities index mark III
MCMC
Markov Chain Monte Carlo
NHS
National Health Service
pMDI
Pressurised metered-dose inhaler
SD
Standard deviation
SE
Standard error
SMI
Soft mist inhalers
WTP
Willingness to pay

Background

Asthma and chronic obstructive pulmonary disease (COPD) are chronic airway diseases with significant socioeconomic burden. Inhalation therapy is the cornerstone of treatment for patients with asthma and COPD. A wide variety of different inhalers are available and can be broadly classified into pressurised metered-dose inhalers (pMDIs), dry powder inhalers (DPIs), breath-actuated metered-dose inhalers (BA-MDIs), and soft mist inhalers (SMI).
Although evidence from randomised controlled trials suggests that all inhaler types could be equally efficacious [1], each inhaler exhibits distinct operating characteristics and good inhaler technique is crucial for achieving optimal treatment effects [2, 3]. Studies have shown that inhaler technique remains poor and the majority of patients do not use their inhalers correctly [4, 5]. Additionally, poor inhaler use is associated with impaired symptom control in both asthma and COPD [57]. Taken together, outcomes from these studies suggested that the ideal inhaler is not currently available. Accordingly, novel inhalers continue to be developed to maximise use and minimise the possibility for incorrect inhaler technique.
Treatment compliance and therapeutic success of the inhalation therapy are dependent not only on the inhaler characteristics, but also on patients’ perception, satisfaction, and preference with the inhaler device [8, 9], as well as their competence in its use [5]. Suboptimal adherence is clearly associated with poor outcomes in patients with asthma and COPD [10]. Multiple factors drive patients’ preference with an inhaler; important features are the intuitiveness of the device and to ensure that correct inhaler technique only requires a limited number of steps, such as the sequence ‘exhale – open – inhale – close’ [11]. Therefore, the understanding of these factors is key to improving adherence to therapy. There is ongoing research to develop new DPIs for patients with asthma and COPD, highlighting the need to understand DPI attributes preferred by patients. Conjoint analyses and discrete choice experiments (DCEs) are frequently applied in healthcare to elicit preferences among patients [12, 13]. Respondents are asked to choose a preferred option from hypothetical scenarios designed to reflect the different attributes encompassed in real-world decisions. DCE can also be used to estimate willingness to pay (WTP) for healthcare interventions [12, 13]. This knowledge can assist healthcare professionals and health authorities in understanding the importance of developing new DPIs that are accessible to patients.
Using the DCE methodology, this study was designed to investigate patient preferences for attributes of DPI devices among patients with asthma or COPD treated with Symbicort® Turbuhaler® and Seretide® Diskus® in Europe. Here we report on findings among patients enrolled in the pilot phase of this study which was performed in France.

Methods

The study comprised two phases. The first, qualitative phase followed a three-step process: (1) a literature review to identify the attributes for DPIs from previous studies; (2) clinical expert interviews; and (3) patient focus group discussions. The second, quantitative phase was the DCE.

Definition of inhaler attributes

Literature review

A literature review on treatment satisfaction and drivers of adherence related to inhalation treatments among patients with asthma or COPD was conducted. This literature review aimed to identify attributes captured in studies evaluating treatment satisfaction among asthma and COPD patients using inhalers. Databases and keywords used for the literature search are listed in Additional file 1: Table S1. Attributes identified from the literature review formed the basis of discussion items among the patient groups. Most often cited inhaler characteristics are listed in Table 1.
Table 1
Most often used terms to describe the different concepts in literature
Concept
Times inhalers characteristics belonging to concept were mentioned in the literature search results
Examples of terms used in the literature to describe the concepts
Appearance
56
Attractiveness, design, colour, shape, size, compact, discrete, weight, portable and durable, protected from moisture
Ease of use, of which:
43
Operating, ease of inhalation, inhaler use quickness, handling, convenience
 Ease of holding and comfort
11
Mouthpiece fits the lips, feel in the hand, easy to hold, ease of carrying
 Ease of preparation of the dose
8
Ease to unpack and assemble, ease to open the inhaler and prepare it for inhalation
 Feedback to indicate correct inhalation and dosage
16
Easily readable and precise dose counter
 Ease of learning to use
14
Easy-to-follow instructions, easy-to-read leaflet, short training time required
Hygiene
10
Hygienic and easy to clean
Environmentally friendly
4
Inhaler and pack being environmentally friendly

Clinical expert interviews

Two French clinical practitioners who specialised in respiratory diseases were contacted through our network, and were interviewed using semi-directed or open questions to provide their expert opinion and rank the identified inhaler attributes from the literature searches. Topics discussed included: inhaler attributes that are important for correct inhaler technique, critical errors in inhaler technique (committed by the patients), and advantages and disadvantages of different inhalers (from the point of view of the clinician). The aim of the interviews was to gather information and develop a discussion guide for the focus group interviews.

Patient focus group discussions

A total of 32 patients identified through general practitioners and pharmacists in France with asthma (age range: 21–70 years) and COPD (age range: 43–82) who had used either a Symbicort Turbuhaler or Seretide Diskus, two of the most frequently used DPIs for inhaled corticosteroids/ long acting beta agonist, for ≥6 months prior to study were enrolled in four focus groups. Written informed consent was signed and dated by patients. Each focus group, consisting of patients with either asthma or COPD, was interviewed separately on a semi-structured basis to identify potential inhaler attributes. The discussions were moderated by an experienced psychologist. Discussions were structured in accordance with results of the literature search and clinician interviews.

Discrete choice experiment design

A pilot study was initially performed to identify any potential areas of misunderstanding. Twenty-five patients (10 with asthma, 10 with COPD and five with mixed COPD/asthma) participated in a cognitive debriefing interview and were asked to complete the survey in a ‘think aloud’ exercise. An additional 17 patients completed the pilot survey. An orthogonal and balanced fractional factorial (FrF) design was generated for the pilot study. This design contained 36 choice sets, divided into three blocks of 12, in order to reduce the number of questions for each participant. Each choice set consisted of three alternatives: two fictitious inhalers and the patient’s current inhaler. Inhalers were described according to attributes defined earlier, as well as a cost attribute. Minor rewording for some attributes was made based on the comments received during the pilot study. In addition, it was decided to present choices in two steps: first a choice between two fictitious inhalers, and then between the inhaler chosen in first step and the current inhaler.
The results from the pilot study were used to construct/develop the experimental design for the main survey, based on the D-efficiency criterion [14], assuming no interactions between attributes. The final design consisted of three blocks of 12 choice sets each.
WTP was defined by asking patients to respond to the following questions: (1) “What is your monthly out-of-pocket expenditure for the treatment of your asthma/COPD? Please take into account all costs directly or indirectly related to your treatment, such as prescription charges, travel costs to visit you doctor or go to the pharmacy, cost of taking time off work to go to the doctor”; (2) “Perhaps you also use healthcare services not covered by the NHS for the treatment of your asthma/COPD? Can you please estimate your monthly total out of pocket expenses (Euros/month)?”

Experimental procedure

Patients ≥18 years of age with a diagnosis of asthma or COPD, and who were using a DPI (either Symbicort Turbuhaler or Seretide Diskus), were included in the study. Patients were recruited through an online research panel. To be eligible for participation, the panel members were asked to indicate the conditions with which they had been diagnosed by a physician, and those with asthma and COPD were selected. Moreover, there was no restriction with regard to the disease control status of patients to participate in this study. The DCE used a web-based platform that allowed participants to complete the survey at home. A screening question was used to ensure eligibility of those responding to the invitation. To help ensure that the correct inhalers were used for the study, patients were presented with pictures of Seretide Diskus and Symbicort Turbuhaler. Before making choices between inhaler profiles, respondents were presented with a description of their current inhaler and asked to state what they considered to be the three most important attributes of that inhaler. This was carried out to familiarise participants with the terminologies of inhaler attributes prior to performing the DCE exercise.

Data collection

Demographic and baseline characteristics, medication history, and quality-of-life data were collected during the survey. Subjective health status was measured by health utilities index mark III (HUI3; a generic multi-attribute, preference-based measure of health status and health-related quality of life that is widely used as an outcome measure in clinical studies, population health surveys, the estimation of quality-adjusted life years, and in economic evaluations). The HUI3 system has eight dimensions: vision, hearing, speech, ambulation, dexterity, emotion, cognition, and pain, with five or six levels per dimension, varying from highly impaired to normal [15, 16]. The HUI3 score is expressed on a scale of 0 to 1: 0 represents a health state equivalent to death and 1 represents perfect health [15].

Statistical analysis

Descriptive statistics (mean, standard deviation [SD] or percentage, as appropriate) were used for the demographic and clinical characteristics.
A ranked ordered logit model was used to estimate marginal utilities associated with each attribute, i.e., incremental utilities between different levels of a specific attribute. A random patient effect was entered into the model to account for the fact that the provided answers of a patient for different choice sets were not independent. The difference between coefficients corresponding to two levels of an attribute represented the marginal utility associated with a change from one level to the other. The cost attribute was entered as a continuous variable and a linear relationship between utility and cost was assumed. The model also included a dummy variable for the current inhaler, to capture a possible preference of patients for keeping their current inhaler, when all attributes are equal. The WTP for a given level of one attribute compared with another was estimated. Interactions between the attributes of asthma and COPD were tested. The model was adjusted with the most relevant covariates (e.g., age, gender, disease [asthma or COPD], income level, satisfaction level) in the data to test whether there is an effect of the covariate on the inhaler choice.
The WTP for a given attribute compared with another was estimated based on outcomes from the logistic model (the ratio of the marginal utility between those two attributes levels divided by the marginal utility associated with a loss of €1 [the opposite of the coefficient estimated for the cost attribute]). Credibility intervals around WTP were estimated using a Markov Chain Monte Carlo (MCMC) method. MCMC is a technique for estimating by simulation the expectation of a statistic in a complex model. Successive random selections form a Markov chain, the stationary distribution of which is the target distribution.

Results

Literature review

The literature review identified 16 studies in which patients were asked to express their preferences between different types of inhalers (DPIs, MDIs, SMIs, and nebulizers) using predefined inhaler characteristics [1732]. None of the studies used patient interviews or focus groups to elicit important attributes specifically related to DPIs.
The literature review revealed no overall consensus on the importance of different inhaler attributes in relation to patient satisfaction across the studies. However, the most often cited inhaler characteristics were related to ease of use of the device (Table 1).
Different terms were used across the different studies to describe relevant concepts for inhaler attributes. Table 1 summarises the different terms and the frequency these were used in the literature reviews.

Patient focus groups

Patients focused mainly on inhaler characteristics related to ease of use, rather than performance, during the patient group discussions.
When asked (towards the end of the discussion) to select the most important inhaler attributes, patients most frequently mentioned the following: size of the dose counter, ability to keep the mouthpiece hygienic (can be washed or can be replaced), ergonomics of the inhaler mouthpiece, presence of a dosing feedback mechanism, ease with which a dose can be prepared, and low inspiratory flow requirements. Although, the mouthpiece of neither the Symbicort Turbuhaler nor Seretide Diskus can be washed or replaced, the hygiene feature was included in the focus group discussions as a factor to consider for future improvement.
Although the attributes selected by patients with asthma or COPD were generally similar, some differences between the two groups were reported: the size of the dose counter was selected as the most important feature of an inhaler by patients with COPD, while the ergonomics of the mouthpiece was selected as the most important feature of an inhaler by patients with asthma.
The outcomes from the literature review, expert interviews, and patient focus groups guided the development of a list of attributes and attribute levels, which were subsequently used in the quantitative study (Table 2). A final seven attributes each described by up to four levels were used in the main survey.
Table 2
Attributes and attribute levels
 
Attributes
Levels
1
Ease of use/fool-proof priming
− 1 step
− 2 to 3 steps
− More than 4 steps to prepare your dose
2
Accurate and easy-to-read dose counter
Precise dose counter
− Yes
− No
3
Dose confirmation
− Taste of lactose
− No taste of lactose
4
Hygiene of mouthpiece
− Mouthpiece can be washed, but not replaced
− Mouthpiece can be replaced, but not washed
− Mouthpiece can be cleaned with a dry cloth, but not washed or replaced
5
Flexibility of device handling
Orientation of device during inhalation process
− Inhaler can be held in any position throughout inhalation process
− Inhaler must be held in certain position throughout inhalation process
6
You can use the inhaler even when you have difficulties breathing in
− Yes
− No
7
Costs associated with using the medication
− Current level of expenditure
− Current level of expenditure + €3/month
− Current level of expenditure + €6/month
− Current level of expenditure + €10/month

Pilot study

Twenty-five patients (10 with asthma, 10 with COPD and five with asthma/COPD) participated in the pilot Cognitive Debriefing interview to identify any potential areas of misunderstanding in the survey. Patients were asked to complete the survey in a ‘think aloud’ exercise. Another 17 patients answered the pilot survey and data were analysed to determine if attribute coefficients were all in the expected direction.

Main DCE survey

A total 294 patients were included, 201 with asthma and 93 with COPD. Patient demographics and clinical characteristics are shown in Table 3.
Table 3
Patient demographics and clinical characteristics
Patient demographic characteristics
 
Asthma (n = 201)
COPD (n = 93)
Total (n = 294)
Age
Mean (SD)
40.30 (13.44)
48.48 (15.16)
42.89 (14.49)
Gender
Male
63 (31.34%)
42 (45.16%)
105 (35.71%)
Female
138 (68.66%)
51 (54.84%)
189 (64.29%)
Current inhaler
Symbicort Turbuhaler
95 (47%)
44 (47%)
139 (47%)
Seretide Diskus
106 (53%)
49 (53%)
155 (53%)
Revenue in last 12 months
<€22,500
97 (48.26%)
40 (43.01%)
137 (46.60%)
€25,000–€34,999
39 (19.40%)
14 (15.05%)
53 (18.03%)
€35,000–€49,999
30 (14.93%)
15 (16.13%)
45 (15.31%)
€50,000–€74,999
15 (7.46%)
7 (7.53%)
22 (7.48%)
€75,000+
2 (1.00%)
6 (6.45%)
8 (2.72%)
No answer
18 (8.96%)
11 (11.83%)
29 (9.86%)
Costs associated with asthma and COPD treatment (€)/month
Mean (SD)
11.89 (21.93)
22.11 (37.37)
15.12 (28.10)
HUI3
Mean (SD)
0.71 (0.25)
0.54 (0.30)
0.66 (0.28)
COPD chronic obstructive pulmonary disease, DPI dry powder inhaler, HUI3 health utilities index mark III, SD standard deviation
In both groups, the majority of patients were female (64% overall). The mean age of patients with COPD was higher compared with that of patients with asthma (48 vs. 40 years of age). Most patients (47% of total patients) reported annual earnings < €22,500. Seretide Diskus and Symbicort Turbuhaler were used by a similar proportion of patients in both groups. Approximately half of the patients (52% asthma; 46% COPD) reported that they were satisfied with their current inhaler. The reported spending on treatment was higher in patients with COPD compared to patients with asthma (€22.11 vs. €11.89 per month, respectively). The average HUI3 utility score was higher in patients with asthma (0.71) compared with patients with COPD (0.54).

Patient preferences and willingness to pay for attributes

Preferences

Similar preferences were reported by patients with asthma and COPD when ranking the inhaler attributes they deemed most valuable (Fig. 1 and Fig. 2); these included: confirmation that the dose was taken (33% of patients with asthma/33% of patients with COPD), accurate and easy-to-read dose counter (24%/23%) and ease of use during episodes of breathing difficulties (23%/22%).
Analysis for interactions between disease (asthma and COPD) and attributes showed that the flexibility of handling and cost attributes were valued differently by asthma and COPD patients; therefore, separate models were estimated for asthma and COPD. Marginal utilities were statistically significant for all attributes except for hygiene (Table 4). Within the COPD group, 27% patients were <40 years of age (n = 25; Range 18–39 years Additional file 2: Table S2). Furthermore half of this younger sub-group of patients with COPD was <28 years-old. As the age of onset for COPD is typically 40 years or above, we performed an additional sub-analysis of patients who were ≥40 years (n = 68, Additional file 3: Table S3). When restricting the sample of COPD patients to those ≥40 years COPD, the ranking of attributes was unchanged, and marginal utilities were generally similar to those reported for the overall COPD population. (Additional file 4: Table S4).
Table 4
Results of ordered logit regression models for asthma and COPD samples
Parameter
Attribute level
Asthma
COPD
Estimate (SE)
p-value
Odds ratio
Estimate (SE)
p-value
Odds ratio
Ease of use
1 step
0.55 (0.081)
<0.0001
1.733
0.282 (0.118)
0.017
1.326
2 or 3 steps
0.281 (0.069)
<0.0001
1.324
0.203 (0.1)
0.043
1.226
Accurate
Yes
0.377 (0.047)
<0.0001
1.458
0.419 (0.069)
<0.0001
1.52
Confirmation that the dose was taken
Taste of lactose
0.333 (0.045)
<0.0001
1.395
0.362 (0.066)
<0.0001
1.436
Hygiene
Mouthpiece can be replaced
–0.032 (0.063)
0.611
0.968
–0.028 (0.091)
0.757
0.972
Mouthpiece can be washed
0.026 (0.063)
0.678
1.027
–0.073 (0.092)
0.427
0.929
Flexibility
Any position
0.164 (0.045)
0.0003
1.178
–0.03 (0.065)
0.646
0.97
Ease of use during episode of breathing difficulties
Yes
0.5 (0.051)
<0.0001
1.649
0.549 (0.075)
<0.0001
1.731
Monthly out-of-pocket money
 
–0.114 (0.012)
<0.0001
0.893
–0.067 (0.017)
<0.0001
0.936
Current inhaler
Yes
0.207 (0.086)
0.016
1.23
0.137 (0.126)
0.275
1.147
COPD chronic obstructive pulmonary disease, SE standard error

Willingness to pay

For most attributes, WTP estimates were higher for patients with COPD, attributed to a lower marginal utility for cost.
Patients with asthma were willing to pay €4.83 per month (95% CI: €3.77–€5.90) for an inhaler that requires one step for dose preparation instead of four, €4.49 per month (95% CI: €2.95–€6.02) for an inhaler that could be used during episodes of breathing difficulties, €3.38 per month (95% CI: €2.11–€4.65) for an accurate and easy-to-read dose counter, €2.98 per month (95% CI: €1.98–€3.97) for an inhaler which provides confirmation that the dose has been taken, and €1.45 per month (95% CI: €0.63–€2.28) for flexibility of handling (Fig. 3).
Patients with COPD were willing to pay €7.70 per month (95% CI: €5.65–€9.76) for an inhaler that could be used during episodes of breathing difficulties, €5.87 per month (95% CI: €3.98–€7.77) for an accurate dose counter, €5.09 per month (95% CI: €3.29–€ 6.89) for an inhaler which provides confirmation that the dose has been taken, and €3.95 per month (95% CI: €0.70–€7.19) for an inhaler which requires one step for dose preparation (Fig. 4).

Choice between current and new inhalers

Patients with asthma were more likely to choose their current inhaler over a new one (all attributes being equal [p = 0.016]). This was numerically similar for patients with COPD; however, the difference between patients who chose or declined their current inhaler was not statistically significant (Overall COPD group, p = 0.275 [Table 4]; ≥40 years COPD group, p = 0.537 [Additional file 4: Table S4]); the marginal utility for keeping the current inhaler is lower than the marginal utility of most DPI attributes.
A positive interaction between satisfaction with current inhaler and probability of choosing the current inhaler (p = 0.0005) was reported: patients who were satisfied with their current inhaler were more likely to choose it (all attributes being equal). Patients who were neither satisfied nor dissatisfied with their current inhaler were neither more likely nor less likely to choose their current inhaler over a new inhaler. Older patients, and those on high incomes, had a higher probability to choose their current inhaler over a new one (Table 5). The choice of the current inhaler was not related to gender.
Table 5
Results of models including interactions between current inhaler and patient characteristics
 
Gender (ref = Male)
Age
Disease (ref = Asthma)
Income
Income level
(ref: <€25,000)
Satisfaction levela (ref = Unsatisfied)
Ease of use
<0.0001
<0.0001
<0.0001
<0.0001
<0.0001
Accurate
<0.0001
<0.0001
<0.0001
<0.0001
<0.0001
Confirmation that the does was taken
<0.0001
<0.0001
<0.0001
<0.0001
<0.0001
Hygiene
0.8125
0.8222
0.823
0.7962
0.8241
Flexibility
0.0059
0.0056
0.0059
0.0059
0.0059
Use with difficulties breathing
<0.0001
<0.0001
<0.0001
<0.0001
<0.0001
Monthly out-of-pocket money
<0.0001
<0.0001
<0.0001
<0.0001
<0.0001
Current inhaler
0.0042
0.0004
0.0035
0.1962
0.5805
Current inhalera characteristic
0.0681
<0.0001
0.135
0.0052
0.0005
aSatisfaction levels were satisfied, neutral and unsatisfied assessing patient’s satisfaction with their current inhaler

Discussion

This study was designed to elicit preferences for DPI attributes among patients with asthma and COPD in France.
The DCE included six device-related attributes and an out-of-pocket expense attribute. Preferences for these attributes were quantified in monetary terms. Five of the six device-related attributes were significant predictors for the choice of an inhaler, and thus had significant marginal utilities. Analyses for interactions between attributes and disease showed that patient preferences for DPI attributes were generally similar among patients with asthma or COPD, as marginal utilities did not differ significantly between groups for five attributes.
An easy-to-use inhaler device, and one that is preferred by patients (i.e. perceived positively), may facilitate correct handling of the inhaler and adherence to therapy, which could help in maintaining symptom control. The high rate of poor inhalation technique in real-life studies supports this hypothesis. It is reported that 20–82% of patients, depending on the type of inhaler and the method of assessment, do not use their DPIs correctly [4, 5, 8, 33, 34]. Moreover, 25% of patients have never received training for using their inhaler device [8], and >50% of patients have not had their inhaler technique checked within the last year [35]. Educating and training patients in the use of their inhalers is crucial for the success of the inhalation therapy and is now an integral part of the Global Initiative for Asthma (GINA) management strategy. GINA recommends that patients receive training in inhaler technique as a component of good clinical practice [36].
Patients with asthma placed the highest values on the ease of use and ability to use the inhaler during episodes of breathing difficulties, and for attributes that would provide patients with reassurances about the inhaled dose being taken, such as precise dose counters and dose confirmation mechanisms. Patients with COPD placed the highest values on the usability of the inhaler during episodes of breathing difficulties and, similar to patients with asthma, on attributes relating to the dose, including the accurate dose counter and dose-confirmation mechanism. Some differences between patients with asthma and those with COPD were also found in this study. Patients with asthma considered the attribute ‘flexibility of handling of an inhaler’ to be of significant value, whereas patients with COPD did not.
The orientation of the inhaler device and positioning during inhalation can affect the efficacy of dose delivery for some devices [3, 37]. A systematic review that evaluated the quality of inhalation technique with well-established DPIs in both adult and paediatric patients with asthma or COPD suggested that one of the most frequent errors with Turbuhaler is incorrect inhaler positioning [8]. In a recent study, patients using Diskus also displayed positioning error [37]. We expected that some of the older patients in this study would have difficulties in holding their inhaler in the right position, for example, because of age-related osteoarthritis or neurologic conditions, and that they would place a high value on this particular attribute. However, our data showed that this was not the case, even though 13% of patients with COPD had dexterity problems and might require support in operating their inhaler. It could be argued that patients were not aware that they were not holding the inhaler correctly; as such, they did not place value on this attribute.
Although a source of difficulties with older established DPIs, device positioning error may have been improved in newer DPIs; for instance, a report on the Spiromax device published in 2015 demonstrated that despite different orientations (45° or 90° tilt) under controlled laboratory conditions dosing consistency was maintained [38]. Further studies are needed to assess orientation-dependent dosing changes in real world scenario for Spiromax, as well as for comparisons with dosing deviations of Turbuhaler and Diskus.
The finding that younger patients were more likely to choose a new inhaler is consistent with our expectations that older patients may be more conservative and/or less demanding, and more likely to prefer their current inhaler over a new one. In particular, the interaction between satisfaction with the current inhaler and the patient’s preference with the current inhaler was positive.
The finding that patients’ value the ‘ease of use’ attribute is consistent with a previous study by Kawata et al. [39], which evaluated patient preference and WTP for attributes of maintenance medication for COPD. Outcomes from this study showed that patients with COPD were willing to pay $16 per month for an inhaler that is ‘quick and easy to use’, compared with an inhaler that is ‘more difficult and time-consuming’ to use. Patients’ perception of ‘ease of use’ as defined by Kawata et al. [39] probably encompasses several of the attributes included in our study. Also, the estimates of WTP in our study were comparable to the values previously published.
In this study population, the proportion of women was higher than men for both asthma and COPD groups. The asthma group could be considered to be representative of the French population of patients with asthma. The reported average age of patients with asthma in France was 37 years in 2006, and the prevalence of the disease is higher in women compared with men [40]. However, the prevalence of COPD is usually higher in men compared with women [41]. The use of a web-based sample to enrol patients could have played a role in this discrepancy, as women are more likely to participate in online surveys compared with men [42]. Patients with asthma were younger and in better health compared with patients with COPD, demonstrated by a higher HUI3 utility score.
There are some limitations to this study: some counterintuitive interactions are noted in the sections above. First, as discussed earlier, 27% of the patients with COPD were under 40 years-old, half of whom were younger than 28 years, which suggests that the diagnosis of COPD was mistakenly reported by some patients. The device attribute data collected from these younger patients with COPD may have confounded the overall COPD group analysis. Therefore, we performed a sub-analysis of patients who were 40 years-old or older and found similar attribute outcomes between the ≥40 year-old patients and the overall COPD study population, suggesting that the data derived from the younger patients did not skew the overall outcome. Second, this study did not assess the aftertaste of the medication used and only accounted for taste of lactose as part of the dose-confirmation attribute. The formulation of the medication has been shown to affect preference. In a multicentre, randomised, open-label, crossover study with two 4-week evaluation periods, which compared patient preference and ease of teaching correct inhaler technique for Pulmicort® Turbuhaler versus pMDIs, 64% of patients preferred Pulmicort Turbuhaler over pMDIs since it was not associated with a ‘bad’ aftertaste [32]. Third, the ergonomics of the mouthpiece was not included in the DCE attributes (although it was found to be an important attribute in focus groups) due to the exclusion of attributes that could not be described in an objective way. Finally, the number of attributes included in the DCE was kept to a concise number in order to simplify the selection of attributes that are deemed most important by patients. This selection, although necessary for this study, could be viewed as somehow biased due to the subjective nature of preselecting attributes by the study team.

Conclusion

In conclusion, findings from this study suggest that patients with asthma and COPD share similar views with regards to inhaler attributes that they value most in a device and would change their inhaler if they were offered the option of a new inhaler with improved characteristics. Patients placed highest values on attributes related to ease of use and ability to use the inhaler during episodes of breathing difficulties.

Acknowledgements

Editorial support was provided by Nadia Korfali of GeoMed, an Ashfield company, part of UDG Healthcare plc, was funded by Teva Branded Pharmaceutical Products R & D, Inc. (Frazer, PA, USA).
Teva provided a full review of the article.

Funding

This study was sponsored by Teva Pharmaceuticals Inc.

Availability of data and materials

All the data and materials can be available on request.
This patient survey study was conducted in accordance with the ethical guidelines of the Declaration of Helsinki and Good Clinical Practice. Study participants provided written informed consent. According to the French Public Health Code (Article L1121-1 [amended with Decree No. 2017-884] and Article L1121-4), approval from an Ethics Review Board was not required for surveys related to patient satisfaction. This study involved personal health data and was authorized by the Commission Nationale de l’Informatique et des Libertés (CNIL) (Declaration No. 1696315 v 0).
Not applicable.

Competing interests

NH, MEN, IA, MT and SA are employees of Creativ-Ceutical; ST and AP are employees of Teva Pharmaceuticals.
NR has received fees for participating in advisory boards, presenting in scientific symposia, consulting, participating in medical congresses from AstraZeneca, Boehringer Ingelheim, Chiesi, Cipla, GlaxoSmithKline, Mundipharma, Novartis, Pfizer, Sandoz, Sanofi, 3M Pharmaceutical, and Teva Pharmaceuticals; research funding from Boehringer Ingelheim, Novartis, and Pfizer; and was a Study Coordinator in research funded by Boehringer Ingelheim, Chiesi, GlaxoSmithKline, and Novartis.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Rau JL. Practical problems with aerosol therapy in COPD. Respir Care. 2006;51(2):158–72.PubMed Rau JL. Practical problems with aerosol therapy in COPD. Respir Care. 2006;51(2):158–72.PubMed
2.
Zurück zum Zitat Al-Jahdali H, Ahmed A, Al-Harbi A, Khan M, Baharoon S, Bin Salih S, et al. Improper inhaler technique is associated with poor asthma control and frequent emergency department visits. Allergy Asthma Clin Immunol. 2013;9(1):8.CrossRefPubMedPubMedCentral Al-Jahdali H, Ahmed A, Al-Harbi A, Khan M, Baharoon S, Bin Salih S, et al. Improper inhaler technique is associated with poor asthma control and frequent emergency department visits. Allergy Asthma Clin Immunol. 2013;9(1):8.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Virchow JC, Akdis CA, Darba J, et al. A review of the value of innovation in inhalers for COPD and asthma. J Mark Access Health Policy. 2015;3. doi:10.3402/jmahp.v3.28760. Virchow JC, Akdis CA, Darba J, et al. A review of the value of innovation in inhalers for COPD and asthma. J Mark Access Health Policy. 2015;3. doi:10.​3402/​jmahp.​v3.​28760.
4.
Zurück zum Zitat Molimard M, Le Gros V. Impact of patient-related factors on asthma control. J Asthma. 2008;45(2):109–13.CrossRefPubMed Molimard M, Le Gros V. Impact of patient-related factors on asthma control. J Asthma. 2008;45(2):109–13.CrossRefPubMed
5.
Zurück zum Zitat Melani AS, Bonavia M, Cilenti V, Cinti C, Lodi M, Martucci P, et al. Inhaler mishandling remains common in real life and is associated with reduced disease control. Respir Med. 2011;105(6):930–8.CrossRefPubMed Melani AS, Bonavia M, Cilenti V, Cinti C, Lodi M, Martucci P, et al. Inhaler mishandling remains common in real life and is associated with reduced disease control. Respir Med. 2011;105(6):930–8.CrossRefPubMed
6.
Zurück zum Zitat Giraud V, Roche N. Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability. Eur Respir J. 2002;19(2):246–51.CrossRefPubMed Giraud V, Roche N. Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability. Eur Respir J. 2002;19(2):246–51.CrossRefPubMed
7.
Zurück zum Zitat Giraud V, Allaert FA, Roche N. Inhaler technique and asthma: feasability and acceptability of training by pharmacists. Respir Med. 2011;105(12):1815–22.CrossRefPubMed Giraud V, Allaert FA, Roche N. Inhaler technique and asthma: feasability and acceptability of training by pharmacists. Respir Med. 2011;105(12):1815–22.CrossRefPubMed
8.
Zurück zum Zitat Lavorini F, Magnan A, Dubus JC, Voshaar T, Corbetta L, Broeders M, et al. Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir Med. 2008;102(4):593–604.CrossRefPubMed Lavorini F, Magnan A, Dubus JC, Voshaar T, Corbetta L, Broeders M, et al. Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir Med. 2008;102(4):593–604.CrossRefPubMed
9.
Zurück zum Zitat Small M, Anderson P, Vickers A, Kay S, Fermer S. Importance of inhaler-device satisfaction in asthma treatment: real-world observations of physician-observed compliance and clinical/patient-reported outcomes. Adv Ther. 2011;28(3):202–12.CrossRefPubMed Small M, Anderson P, Vickers A, Kay S, Fermer S. Importance of inhaler-device satisfaction in asthma treatment: real-world observations of physician-observed compliance and clinical/patient-reported outcomes. Adv Ther. 2011;28(3):202–12.CrossRefPubMed
10.
Zurück zum Zitat Lareau SC, Hodder R. Teaching inhaler use in chronic obstructive pulmonary disease patients. J Am Acad Nurse Pract. 2012;24(2):113–20.CrossRefPubMed Lareau SC, Hodder R. Teaching inhaler use in chronic obstructive pulmonary disease patients. J Am Acad Nurse Pract. 2012;24(2):113–20.CrossRefPubMed
11.
Zurück zum Zitat Virchow JC, Akdis CA, Darba J, Dekhuijzen R, Hartl S, Kobelt G, et al. A review of the value of innovation in inhalers for COPD and asthma. J Market Access Health Policy. 2015;3:28760.CrossRef Virchow JC, Akdis CA, Darba J, Dekhuijzen R, Hartl S, Kobelt G, et al. A review of the value of innovation in inhalers for COPD and asthma. J Market Access Health Policy. 2015;3:28760.CrossRef
12.
Zurück zum Zitat Maas A, Stalpers L. Assessing utilities by means of conjoint measurement: an application in medical decision analysis. Med Decis Making. 1992;12(4):288–97.CrossRefPubMed Maas A, Stalpers L. Assessing utilities by means of conjoint measurement: an application in medical decision analysis. Med Decis Making. 1992;12(4):288–97.CrossRefPubMed
13.
14.
Zurück zum Zitat Reed Johnson F, Lancsar E, Marshall D, Kilambi V, Muhlbacher A, Regier DA, et al. Constructing experimental designs for discrete-choice experiments: report of the ISPOR Conjoint Analysis Experimental Design Good Research Practices Task Force. Value Health. 2013;16(1):3–13.CrossRefPubMed Reed Johnson F, Lancsar E, Marshall D, Kilambi V, Muhlbacher A, Regier DA, et al. Constructing experimental designs for discrete-choice experiments: report of the ISPOR Conjoint Analysis Experimental Design Good Research Practices Task Force. Value Health. 2013;16(1):3–13.CrossRefPubMed
15.
Zurück zum Zitat Feeny D, Furlong W, Torrance GW, Goldsmith CH, Zhu Z, DePauw S, et al. Multiattribute and single-attribute utility functions for the health utilities index mark 3 system. Med Care. 2002;40(2):113–28.CrossRefPubMed Feeny D, Furlong W, Torrance GW, Goldsmith CH, Zhu Z, DePauw S, et al. Multiattribute and single-attribute utility functions for the health utilities index mark 3 system. Med Care. 2002;40(2):113–28.CrossRefPubMed
16.
Zurück zum Zitat Horsman J, Furlong W, Feeny D, Torrance G. The Health Utilities Index (HUI): concepts, measurement properties and applications. Health Qual Life Outcomes. 2003;1:54.CrossRefPubMedPubMedCentral Horsman J, Furlong W, Feeny D, Torrance G. The Health Utilities Index (HUI): concepts, measurement properties and applications. Health Qual Life Outcomes. 2003;1:54.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Barrons R, Pegram A, Borries A. Inhaler device selection: special considerations in elderly patients with chronic obstructive pulmonary disease. Am J Health Syst Pharm. 2011;68(13):1221–32.CrossRefPubMed Barrons R, Pegram A, Borries A. Inhaler device selection: special considerations in elderly patients with chronic obstructive pulmonary disease. Am J Health Syst Pharm. 2011;68(13):1221–32.CrossRefPubMed
18.
Zurück zum Zitat Bunnag C, Fuangtong R, Pothirat C, Punyaratabandhu P. A comparative study of patients’ preferences and sensory perceptions of three forms of inhalers among Thai asthma and COPD patients. Asian Pac J Allergy Immunol. 2007;25(2-3):99–109.PubMed Bunnag C, Fuangtong R, Pothirat C, Punyaratabandhu P. A comparative study of patients’ preferences and sensory perceptions of three forms of inhalers among Thai asthma and COPD patients. Asian Pac J Allergy Immunol. 2007;25(2-3):99–109.PubMed
19.
Zurück zum Zitat Chang YS, Park MJ, Bai C, Cai B, Kartasasmita C, Margono BP, et al. Comparative study of patients in correct usage of and preference for the Swinghaler and Turbuhaler multidose inhalers. J Asthma. 2012;49(7):750–6.CrossRefPubMed Chang YS, Park MJ, Bai C, Cai B, Kartasasmita C, Margono BP, et al. Comparative study of patients in correct usage of and preference for the Swinghaler and Turbuhaler multidose inhalers. J Asthma. 2012;49(7):750–6.CrossRefPubMed
20.
Zurück zum Zitat Chapman KR, Fogarty CM, Peckitt C, Lassen C, Jadayel D, Dederichs J, et al. Delivery characteristics and patients’ handling of two single-dose dry-powder inhalers used in COPD. Int J Chron Obstruct Pulmon Dis. 2011;6:353–63.PubMedPubMedCentral Chapman KR, Fogarty CM, Peckitt C, Lassen C, Jadayel D, Dederichs J, et al. Delivery characteristics and patients’ handling of two single-dose dry-powder inhalers used in COPD. Int J Chron Obstruct Pulmon Dis. 2011;6:353–63.PubMedPubMedCentral
21.
Zurück zum Zitat Ferguson GT, Ghafouri M, Dai L, Dunn LJ. COPD patient satisfaction with ipratropium bromide/albuterol delivered via Respimat: a randomized, controlled study. Int J Chron Obstruct Pulmon Dis. 2013;8:139–50.CrossRefPubMedPubMedCentral Ferguson GT, Ghafouri M, Dai L, Dunn LJ. COPD patient satisfaction with ipratropium bromide/albuterol delivered via Respimat: a randomized, controlled study. Int J Chron Obstruct Pulmon Dis. 2013;8:139–50.CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Hodder R, Price D. Patient preferences for inhaler devices in chronic obstructive pulmonary disease: experience with Respimat Soft Mist inhaler. Int J Chron Obstruct Pulmon Dis. 2009;4:381–90.CrossRefPubMedPubMedCentral Hodder R, Price D. Patient preferences for inhaler devices in chronic obstructive pulmonary disease: experience with Respimat Soft Mist inhaler. Int J Chron Obstruct Pulmon Dis. 2009;4:381–90.CrossRefPubMedPubMedCentral
23.
24.
Zurück zum Zitat Moore AC, Stone S. Meeting the needs of patients with COPD: patients’ preference for the Diskus inhaler compared with the Handihaler. Int J Clin Pract. 2004;58(5):444–50.CrossRefPubMed Moore AC, Stone S. Meeting the needs of patients with COPD: patients’ preference for the Diskus inhaler compared with the Handihaler. Int J Clin Pract. 2004;58(5):444–50.CrossRefPubMed
25.
Zurück zum Zitat Ozturk C, Kaya A, Bilgin C, Yucesoy L, Ikidag B, Demirel M, et al. Evaluation of inhaler technique and patient satisfaction with fixed-combination budesonide/formoterol dry-powder inhaler in chronic obstructive pulmonary disease (COPD): data on real-life clinical practice in Turkey. Tuberk Toraks. 2012;60(4):301–13.CrossRefPubMed Ozturk C, Kaya A, Bilgin C, Yucesoy L, Ikidag B, Demirel M, et al. Evaluation of inhaler technique and patient satisfaction with fixed-combination budesonide/formoterol dry-powder inhaler in chronic obstructive pulmonary disease (COPD): data on real-life clinical practice in Turkey. Tuberk Toraks. 2012;60(4):301–13.CrossRefPubMed
26.
Zurück zum Zitat Schulte M, Osseiran K, Betz R, Wencker M, Brand P, Meyer T, et al. Handling of and preferences for available dry powder inhaler systems by patients with asthma and COPD. J Aerosol Med Pulm Drug Deliv. 2008;21(4):321–8.CrossRefPubMed Schulte M, Osseiran K, Betz R, Wencker M, Brand P, Meyer T, et al. Handling of and preferences for available dry powder inhaler systems by patients with asthma and COPD. J Aerosol Med Pulm Drug Deliv. 2008;21(4):321–8.CrossRefPubMed
27.
Zurück zum Zitat Schurmann W, Schmidtmann S, Moroni P, Massey D, Qidan M. Respimat Soft Mist inhaler versus hydrofluoroalkane metered dose inhaler: patient preference and satisfaction. Treat Respir Med. 2005;4(1):53–61.CrossRefPubMed Schurmann W, Schmidtmann S, Moroni P, Massey D, Qidan M. Respimat Soft Mist inhaler versus hydrofluoroalkane metered dose inhaler: patient preference and satisfaction. Treat Respir Med. 2005;4(1):53–61.CrossRefPubMed
28.
Zurück zum Zitat Van Der Palen J, Eijsvogel MM, Kuipers BF, Schipper M, Vermue NA. Comparison of the Diskus inhaler and the Handihaler regarding preference and ease of use. J Aerosol Med. 2007;20(1):38–44.CrossRef Van Der Palen J, Eijsvogel MM, Kuipers BF, Schipper M, Vermue NA. Comparison of the Diskus inhaler and the Handihaler regarding preference and ease of use. J Aerosol Med. 2007;20(1):38–44.CrossRef
29.
Zurück zum Zitat van der Palen J, Ginko T, Kroker A, van der Valk P, Goosens M, Padulles L, et al. Preference, satisfaction and errors with two dry powder inhalers in patients with COPD. Expert Opin Drug Deliv. 2013;10(8):1023–31.CrossRefPubMed van der Palen J, Ginko T, Kroker A, van der Valk P, Goosens M, Padulles L, et al. Preference, satisfaction and errors with two dry powder inhalers in patients with COPD. Expert Opin Drug Deliv. 2013;10(8):1023–31.CrossRefPubMed
30.
Zurück zum Zitat Vincken W, Dekhuijzen PR, Barnes P. The ADMIT series - Issues in inhalation therapy. 4) How to choose inhaler devices for the treatment of COPD. Prim Care Respir J. 2010;19(1):10–20.CrossRefPubMed Vincken W, Dekhuijzen PR, Barnes P. The ADMIT series - Issues in inhalation therapy. 4) How to choose inhaler devices for the treatment of COPD. Prim Care Respir J. 2010;19(1):10–20.CrossRefPubMed
31.
Zurück zum Zitat Weiss KB, Paramore LC, Liljas B, Revicki DA, Luce BR. Patient satisfaction with budesonide Turbuhaler versus triamcinolone acetonide administered via pressurized metered-dose inhaler in a managed care setting. J Asthma. 2005;42(9):769–76.CrossRefPubMed Weiss KB, Paramore LC, Liljas B, Revicki DA, Luce BR. Patient satisfaction with budesonide Turbuhaler versus triamcinolone acetonide administered via pressurized metered-dose inhaler in a managed care setting. J Asthma. 2005;42(9):769–76.CrossRefPubMed
32.
Zurück zum Zitat Welch MJ, Nelson HS, Shapiro G, Bensch GW, Sokol WN, Smith JA, et al. Comparison of patient preference and ease of teaching inhaler technique for Pulmicort Turbuhaler versus pressurized metered-dose inhalers. J Aerosol Med. 2004;17(2):129–39.CrossRefPubMed Welch MJ, Nelson HS, Shapiro G, Bensch GW, Sokol WN, Smith JA, et al. Comparison of patient preference and ease of teaching inhaler technique for Pulmicort Turbuhaler versus pressurized metered-dose inhalers. J Aerosol Med. 2004;17(2):129–39.CrossRefPubMed
33.
Zurück zum Zitat Papi A, Haughney J, Virchow JC, Roche N, Palkonen S, Price D. Inhaler devices for asthma: a call for action in a neglected field. Eur Respir J. 2011;37(5):982–5.CrossRefPubMed Papi A, Haughney J, Virchow JC, Roche N, Palkonen S, Price D. Inhaler devices for asthma: a call for action in a neglected field. Eur Respir J. 2011;37(5):982–5.CrossRefPubMed
34.
Zurück zum Zitat Arora P, Kumar L, Vohra V, Sarin R, Jaiswal A, Puri MM, et al. Evaluating the technique of using inhalation device in COPD and bronchial asthma patients. Respir Med. 2014;108(7):992–8.CrossRefPubMed Arora P, Kumar L, Vohra V, Sarin R, Jaiswal A, Puri MM, et al. Evaluating the technique of using inhalation device in COPD and bronchial asthma patients. Respir Med. 2014;108(7):992–8.CrossRefPubMed
35.
Zurück zum Zitat Price D, Fletcher M, van der Molen T. Asthma control and management in 8000 European patients: the REcognise Asthma and LInk to Symptoms and Experience (REALISE) survey. NPJ Prim Care Respir Med. 2014;24:14009.CrossRefPubMedPubMedCentral Price D, Fletcher M, van der Molen T. Asthma control and management in 8000 European patients: the REcognise Asthma and LInk to Symptoms and Experience (REALISE) survey. NPJ Prim Care Respir Med. 2014;24:14009.CrossRefPubMedPubMedCentral
37.
Zurück zum Zitat Chrystyn H, Price DB, Molimard M, Haughney J, Bosnic-Anticevich S, Lavorini F, et al. Comparison of serious inhaler technique errors made by device-naive patients using three different dry powder inhalers: a randomised, crossover, open-label study. BMC Pulm Med. 2016;16:12.CrossRefPubMedPubMedCentral Chrystyn H, Price DB, Molimard M, Haughney J, Bosnic-Anticevich S, Lavorini F, et al. Comparison of serious inhaler technique errors made by device-naive patients using three different dry powder inhalers: a randomised, crossover, open-label study. BMC Pulm Med. 2016;16:12.CrossRefPubMedPubMedCentral
38.
Zurück zum Zitat Canonica GW, Arp J, Keegstra JR, Chrystyn H. Spiromax, a new dry powder inhaler: dose consistency under simulated real-world conditions. J Aerosol Med Pulm Drug Deliv. 2015;28(5):309–19.CrossRefPubMedPubMedCentral Canonica GW, Arp J, Keegstra JR, Chrystyn H. Spiromax, a new dry powder inhaler: dose consistency under simulated real-world conditions. J Aerosol Med Pulm Drug Deliv. 2015;28(5):309–19.CrossRefPubMedPubMedCentral
39.
Zurück zum Zitat Kawata AK, Kleinman L, Harding G, Ramachandran S. Evaluation of patient preference and willingness to pay for attributes of maintenance medication for chronic obstructive pulmonary disease (COPD). Patient. 2014;7(4):413–26.CrossRefPubMedPubMedCentral Kawata AK, Kleinman L, Harding G, Ramachandran S. Evaluation of patient preference and willingness to pay for attributes of maintenance medication for chronic obstructive pulmonary disease (COPD). Patient. 2014;7(4):413–26.CrossRefPubMedPubMedCentral
41.
Zurück zum Zitat Surveillance épidémiologique de la broncho-pneumopathie chronique obstructive et de l’insuffisance respiratoire chronique en France. Link: http://www.invs.sante.fr/Dossiers-thematiques/Maladies-chroniques-et-traumatismes/Broncho-pneumopathie-chronique-obstructive-et-insuffisance-respiratoire-chronique/Surveillance-epidemiologique-de-la-broncho-pneumopathie-chronique-obstructive-et-de-l-insuffisance-respiratoire-chronique-en-France. Surveillance épidémiologique de la broncho-pneumopathie chronique obstructive et de l’insuffisance respiratoire chronique en France. Link: http://​www.​invs.​sante.​fr/​Dossiers-thematiques/​Maladies-chroniques-et-traumatismes/​Broncho-pneumopathie-chronique-obstructive-et-insuffisance-respiratoire-chronique/​Surveillance-epidemiologique-de-la-broncho-pneumopathie-chronique-obstructive-et-de-l-insuffisance-respiratoire-chronique-en-France.​
Metadaten
Titel
Patient preferences for dry powder inhaler attributes in asthma and chronic obstructive pulmonary disease in France: a discrete choice experiment
verfasst von
Natalia Hawken
Saku Torvinen
Mohamed-Elmoctar Neine
Ikbel Amri
Mondher Toumi
Samuel Aballéa
Adam Plich
Nicolas Roche
Publikationsdatum
01.12.2017
Verlag
BioMed Central
Erschienen in
BMC Pulmonary Medicine / Ausgabe 1/2017
Elektronische ISSN: 1471-2466
DOI
https://doi.org/10.1186/s12890-017-0439-x

Weitere Artikel der Ausgabe 1/2017

BMC Pulmonary Medicine 1/2017 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.