Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention

Zeitschrift:
Heart and Vessels > Ausgabe 5/2016
Autoren:
Shigeru Nakamura, Tomoko Kobayashi, Atsushi Funatsu, Tadahisa Okada, Maria Mauti, Yuki Waizumi, Shinichi Yamada
Wichtige Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1007/​s00380-015-0667-z) contains supplementary material, which is available to authorized users.

Abstract

Coronary angiography and intervention can expose patients to high radiation dose. This retrospective study quantifies the patient dose reduction due to the introduction of a novel X-ray imaging noise reduction technology using advanced real-time image noise reduction algorithms and optimized acquisition chain for fluoroscopy and exposure in interventional cardiology. Patient, procedure and radiation dose data were retrospectively collected in the period August 2012–August 2013 for 883 patients treated with the image noise reduction technology (referred as “new system”). The same data were collected for 1083 patients in the period April 2011–July 2012 with a system using state-of-the-art image processing and reference acquisition chain (referred as “reference system”). Procedures were divided into diagnostic (CAG) and intervention (PCI). Acquisition parameters such as fluoroscopy time, volume of contrast medium, number of exposure images and number of stored fluoroscopy images were collected to classify procedure complexity. The procedural dose reduction was investigated separately for three main cardiologists. The new system provides significant dose reduction compared to the reference system. Median DAP values decreased for all procedures (p < 0.0001) from 172.7 to 59.4 Gy cm2, for CAG from 155.1 to 52.0 Gy cm2 and for PCI from 229.0 to 85.8 Gy cm2 with reduction quantified at 66, 66 and 63 %, respectively. Based on median values, the dose reduction for all procedures was 68, 60 and 67 % for cardiologists 1, 2 and 3, respectively. The X-ray imaging technology combining advanced real-time image noise reduction algorithms and anatomy-specific optimized fluoroscopy and cine acquisition chain provides 66 % patient dose reduction in interventional cardiology.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Zusatzmaterial
Supplementary material 1 (MPG 2940 kb)
380_2015_667_MOESM1_ESM.mpg
Supplementary material 2 (MPG 3790 kb)
380_2015_667_MOESM2_ESM.mpg
Supplementary material 3 (MPG 2708 kb)
380_2015_667_MOESM3_ESM.mpg
Supplementary material 4 (MPG 3914 kb)
380_2015_667_MOESM4_ESM.mpg
Supplementary material 5 (MPG 2614 kb)
380_2015_667_MOESM5_ESM.mpg
Supplementary material 6 (MPG 3298 kb)
380_2015_667_MOESM6_ESM.mpg
Supplementary material 7 (MPG 2616 kb)
380_2015_667_MOESM7_ESM.mpg
Supplementary material 8 (MPG 4620 kb)
380_2015_667_MOESM8_ESM.mpg
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 5/2016

Heart and Vessels 5/2016 Zur Ausgabe

Neu im Fachgebiet Kardiologie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Kardiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise