Abstract

Background

Bony avulsion fractures of the distal phalanges can result in mallet finger deformity if not treated appropriately. Therefore, only minimally displaced fractures can be treated conservatively with a good outcome, as dislocation occurs very often. Several surgical treatment options have been developed during the past decades. Data concerning the recently developed hook plate are promising. So far, no data concerning the subjective satisfaction with this method have been published. Therefore, we have analyzed the outcome after hook plate implantation using a self-assessment score, which focuses also on subjective parameters and satisfaction.

Methods

Standardized questionnaires (self-assessment scores and SF-36 questionnaire) were sent to each patient treated with a hook plate due to fracture of the distal phalanx, type Doyle IVb and IVc. Clinical data were evaluated according to the medical record. Scores given per question range from 0 to 10, 10 is the worst and 0 the best outcome.

Results

From 69 patients treated, 38 (58%) were enrolled. The whole collective (n = 38) reached a score of 39.7 ± 28.7 points, while men had slightly better results. Men (n = 24) achieved 37.3 ± 27.9 points, women (n = 14) 43.9 ± 30.7 points. Women had significantly better results when analyzed later than 12 months after surgery (52.1 ± 27.9 vs. 29.1 ± 32.8), whereas no changes could be detected in the male group (37.1 ± 29.9 vs. 37.4 ± 27.6). Overall, men were slightly more satisfied than women. Most satisfaction was found regarding pain and fine motor skills (0–0.46 points). Esthetic aspect and nail deformities (3.65 points average) led to the highest dissatisfaction. No differences in the SF 36 score could be detected.

Conclusions

The hook plate is not only a convenient method but it also results in high patient satisfaction. Nail deformities are challenging; however, with increasing experience of the surgeon they decrease. SF 36 score is not an appropriate testing tool for this problem.
Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1186/​s40001-018-0332-y) contains supplementary material, which is available to authorized users.

Background

Traumatic mallet fractures are avulsion fractures of the distal phalangeal base including peri- or intraarticular fractures comprising the insertion of the extensor tendon. Indication for surgery depends on the fragment size and its dislocation, as well as a possible dislocation of the distal phalanx. These fractures are classified according to the Doyle classification. Fragments less than 50% of the articular joint (Doyle IVb) without dislocation could be treated conservatively with good results. However, in case of fragment dislocation (Doyle IVc) or dislocation of the distal phalanx surgical treatment is indicated [13].
Several treatment options for the bony mallet finger have been developed during the past decades [1416]. These are for example k-wire fixation [3], percutaneous extension block wiring [4, 5], screw osteosynthesis [6], compression pins [7], pull-through wires, figure of eight wiring [8, 9], tension band wiring [8, 10, 11], and umbrella handle k-wire fixation [12, 13]. However, these methods achieve only poor reduction and are associated with unsatisfactory outcomes and several complications [2, 17]. Temporary k-wire arthrodesis of the DIP, for example, increases the risk of DIP arthrosis and cartilage injury due to drilling heat and the damage done by the k-wiring. To avoid these problems, microscrew fixation has been tried [6, 18]. It allows a closed, rigid fixation without joint damage. However, small fragment are often fractured by the microscrew which makes a fixation impossible. Therefore, the hook plate has been developed [2, 17]. The first results of hook plate fixation for mallet fractures/Doyle IVc published seem promising [17, 19] (Fig. 1). There are a few studies published concerning functional outcome after hook plate fixation of avulsion fractures of phalanges. Aim of this study was to analyze the subjective and objective outcome and the patients’ satisfaction with this fixation method. In contrast to the preceding publications, this study has focused not only on objective parameters concerning the outcome but also on subjective patient satisfaction.

Methods

From 2012 to 2015, 69 patients with a distal avulsion fracture were treated with hook plate fixation. The inclusion criteria included age > 18 years, fracture of the distal phalanx, fracture type Doyle IVb and IVc which were treated with hook plate fixation and willingness to give their informed consent to participation. Standardized questionnaires (self-assessment scores and SF-36 questionnaire) were sent to each patient postoperatively after having given their informed consent; clinical data, e.g., patient age, affected finger, and gender, were evaluated according to the medical record. The local ethical review committee of the Faculty of Medicine of the Technical University of Munich approved this study (369/14). The study was performed according to the Declaration of Helsinki in its newest version.
The self-assessment score was sent to the patients 3 months postoperatively at the earliest. It consists of 24 questions concerning individual satisfaction and range of movement (Table 1). Scores given per question range from 0 to 10, 10 is the worst and 0 the best outcome. Thus, the lower the maximum score the better the result (Additional file 1).
Table 1
The five best and worst rated items of the whole collective
Patients
Five best rated items
Five worst rated items
All patients
8, 6, 3, 7, 14
19, 11, 24, 17, 22
< 12 months postop
8, 7, 6, 3, 14
11, 19, 24, 17, 5
≥ 12 months postop
8, 6, 3, 14, 7
19, 17, 22, 11, 24
1. Intensity of pain, 4 weeks
2. Most intense pain, 4 weeks
3. Current intensity of pain
4. Frequency of pain, 4 weeks
5. Stress-induced pain
6. Rest pain
7. Pain-related sleeping problems
8. Frequency of intake of painkillers
9. Paraesthesia
10. Swelling
11. Nail deformity
12. Typing on a keyboard
13. To do up/undo one’s button
14. To lace up one’s shoes
15. Affection of work life
16. Affection of doing one‘s hobbies
17. Overall function
18. Images (➔ extension deficit)
19. Cosmetic result
20. Worries
21. Quality of life
22. Overall treatment result
23. Redecision for hook plate in case of another accident
24. Annoyance by hook plate (if in situ)
While pain intensity (during movement, during sleep, while rest) was low and painkiller intake was seldom, patients were unsatisfied with the cosmetic result and the stress-induced pain
Furthermore, the SF-36 life quality score was sent to all patients as well. Questionnaire evaluation was performed according to the SF-36 instructions.

Results

Epidemiology

Overall, we treated 69 patients with a hook plate due to a distal phalanx avulsion fracture. Three of them were younger than 18 years and excluded from the study. Of the remaining 66 patients, 28 (42%) had to be excluded because 6 were not reachable, 10 did not answer the questionnaire and 12 refused participation. Thus, 38 patients (58%) were enrolled, 38 questionnaires, and 36 SF 36 scores could be evaluated (Fig. 2).
Overall, the gender ratio was male:female 24:14; the mean age was 38.1 years (range 20–77), in 12 patients (m:f = 7:5) the hook plate had already been removed. 19 patients were analyzed 3–12 months and 19 patients were analyzed more than 12 months after implantation of the hook plate (Table 2).
Table 2
This table depicts the patient collective before and after metal removal
 
Male
Female
Male + female
Count
24 (63%)
14 (37%)
38 (100%)
Ø age
38.1 (20–77)
36.8 (23–74)
37.6 (20–77)
Removal of hook plate
8 (33%)
6 (43%)
14 (37%)
In 60.5% of the patients, the fifth finger was involved (n = 23), in 13.2% the third and ring finger (n = 5 each), in 10.5% the index finger (n = 4) and in 2.6% (n = 1) the thumb (Table 3).
Table 3
The distribution of the injured fingers
 
1
2
3
4
5
Count (L/R)
1
0
0
4
4
1
2
3
9
14
L + R
1 (2.6%)
4 (10.5%)
5 (13.2%)
5 (13.2%)
23 (60.5%)
Mean score
26.3
39.3
34.6
33.3
42.39
SF36 PHYSu/PSYSu
50.22/32.95
53.59/55.47
55.29/45.53
52.77/51.91
54.43/51.52
The left side was in 16 (42%) and the right side in 22 (58%) patients injured. The little finger (60.5%) was affected most frequently

Self-assessment score

The whole collective (n = 38) reached a score of 39.7 ± 28.7 points. Men (n = 24) achieved 37.3 ± 27.9 points, women (n = 14) 43.9 ± 30.7 points. Metal removal did not change the score in the male group (n = 7) 36.7 ± 17.7 before vs. 37.5 ± 31.7 points after metal removal and significantly in the female group (n = 5) 49.8 ± 23.3 after vs. 40.6 ± 34.0 before metal removal. The whole collective before metal removal had an overall score of 38.4 ± 31 points (n = 26) (Table 4).
Table 4
This table depicts the results of the self evaluation questionnaires
 
Male
Mean score (SD) (n)
Female
Mean score (SD) (n)
Male + female
Mean score (SD) (n)
Mean score
37.3 (27.9) (24)
43.9 (30.7) (14)
39.7 (28.7) (38)
After removal of HP
36.7 (17.7) (7)
49.8 (23.2) (5)
41.6 (20.6) (12)
Before removal of HP
37.5 (31.7) (17)
40.6 (34.0) (9)
38.4 (31) (26)
< 12 months postop
37.1 (29.9) (10)
52.1 (27.9) (9)
44.2 (29.2) (19)
≥ 12 months postop
37.4 (27.6) (14)
29.1 (32.8)(5)
35.2 (28.3) (19)
Moreover, there were no differences in score in the male group concerning the time after implantation of the hook plate (< 12 months vs. ≥ 12 months: 37.1 ± 29.9 vs. 37.4 ± 27.6). However, women had significant better scores 12 months after surgery compared with those analyzed earlier (29.1 ± 32.8 vs. 52.1 ± 27.9) (Table 4).
Overall, men (n = 24) were slightly more satisfied with the hook plate treatment than women (n = 14) (37.3 ± 27.9 vs. 43.9 ± 30.7) (Table 4).
Regarding the single questions, the most satisfaction was found regarding pain (0.05 points average), pain killer intake (0 points), paraesthesia (0.81 points), and fine motor skills such as buttoning the shirt (0.68 points) or tying the shoelaces (0.46 points). The highest score, which means the highest dissatisfaction, could be found regarding the esthetic aspect (4.32 points), nail deformities (4.16 points), and the bulky appearing of the finger due to the plate with an overall feeling of impairment (3.65 points average) (Table 1).
Regarding the outcome after metal removal, no significant changes could be found in the whole collective, except a significant higher dissatisfaction regarding cosmetic result and nail deformities after metal removal compared to the patients with implanted hook plate. However, the stress-induced pain was reduced after hook plate removal (Fig. 3).
Moreover, no significant changes could be detected regarding the time except nail deformity and annoyance concerning the plate. The period of time after surgery has no significant impact on the subjective satisfaction (Fig. 4, Table 3).

SF-36 life quality score

Regarding the SF-36 life quality score, we could detect no differences in the whole collective. The mean SF 36 Score was about 50 points in men, women, before removal of the plate, after removal of the plate, within 12 months post surgery as well as later than 12 months after surgery. As 50 points is defined as the baseline, according to the mean score of a predetermined population, no changes in SF-36 score could be detected, although some patients were unsatisfied with the esthetic aspect of the hook plate (Table 5).
Table 5
In this table the results of the SF 36 score are depicted
Scale
Male
Female
Male + female
Mean score
53.40 (5.44) (23)
49.60 (7.50) (23)
55.38 (3.09) (13)
52.56 (6.18) (13)
54.11 (4.78) (36)
50.67 (7.11) (36)
After removal of hook plate
56.12 (4.16) (6)
45.26 (5.75) (6)
55.50 (3.53) (4)
51.84 (3.57) (4)
55.87 (3.73) (10)
47.89 (5.84) (10)
Hook plate in situ
52.43 (5.62) (17)
51.13 (7.58) (17)
55.32 (3.11) (9)
52.89 (7.22) (9)
53.43 (5.02) (26)
51.74 (7.37) (26)
< 12 months
51.76 (5.45) (10)
50.54 (8.71) (10)
54.87 (3.06) (8)
52.71 (7.10) (8)
53.14 (4.70) (18)
51.51 (7.89) (18)
≥ 12 months
54.66 (5.30) (13)
48.87 (6.70) (13)
56.18 (3.31) (5)
52.33 (5.12) (5)
55.08 (4.79) (18)
49.83 (6.35) (18)
The mean score is shown with the standard deviation (SD) and number of patients in braces. In the first box the score of the physical health summary scale is depicted and in the second box the score of the mental health summary scale is shown. No significant differences could be detected

Discussion

The avulsion of the terminal extensor tendon from the base of the distal phalanx with or without a bony fragment is called a mallet finger. The disruption of the terminal extensor tendon results in the characteristic flexion deformity of the distal interphalangeal joint. Axial loading or a forceful flexion of the extended digit, as it can be found typically in ball-related sports injuries, is the common trauma mechanisms [20]. Inadequate treatment results in extensor lag, early osteoarthritic changes of the distal interphalangeal joint, or even a swan neck deformity [1, 21].
Treatment options include conservative strategies and surgical procedures. Some authors suggest surgery for avulsion fractures when more than one-third of the articular surface is involved as well as for subluxation or fragment displacement which cannot be reduced in a finger splint completely extending the distal interphalangeal joint [22]. Other authors advocate conservative treatment with splint fixation. However, due to the high complication rate during conservative treatment like losing reduction, and reduced flexion of the distal interphalangeal joint [1], the authors advocate surgical treatment of all bony lesions already with only minimal displacement.
Aims of the surgical treatment are restoration of a congruent articular arc without subluxation and of an anatomical reduction and fixation of the bony fragment to prevent joint deformity, post-traumatic arthrosis and stiffness. Several different surgical techniques exist and have been discussed in the literature: open reduction and k-wire fixation [23], tension band wire [10, 11], tenodermodesis [24], pull-out steel wires [11] and screw fixation [6]. Percutaneous pin fixation [16, 25], percutaneous extension block pinning [26] and percutaneous compression fixation pins [18] and the so-called fish hook technique [27] have also been tried to minimize surgical complications while improving fragment reduction.
Although numerous different surgical techniques exist, the postoperative complication rate in general has been rather high, ranging from 3 to 55% depending on the study cited [19, 28, 29]. However, the recently developed hook plate showed promising results. Unfortunately, the few studies published deal only with a small number of patients, i.e., n = 9 [2] or n = 13 [30]. Szalay et al. [17] were the first with a higher number of 59 patients. In their study, nail deformity occurred in 12% using the Stryker hook plate. Teoh et al. also used the Medartis® hook plate and reported nail deformities in 23% (3 patients out of 9) [2]. We had a collective of 38 patients enrolled and nail deformity was also the most criticized aspect of this treatment. In fact, it was one of the subjectively most criticized aspects of this treatment followed immediately by the unhappiness concerning the esthetic aspect of the distal phalanx due to the bulking of the plate. However, we noticed a certain training curve concerning the nail deformities, as their frequency became less over time. Like Teoh and Lee [2], we recommend removal of the plate 3–6 months after implantation. However, not all patients wanted a plate removal because they did not feel annoyed by it.
So far, the outcome of the treatment with a hook plate has not been analyzed concerning the subjective satisfaction of the patients. Studies could show good to excellent radiological and clinical outcomes with complete bony consolidation and proper plate positioning as well as good tendon function and proper movement of the finger. This study has focused on the subjective outcome of the patient concerning the individual satisfaction with the surgery.
Moreover, the time period after implantation has no decisive impact on the subjective satisfaction except, once again nail deformity and subjective annoyance by the hook plate. Both issues were rated worse from the patients within the first 12 months after surgery. One reason for that might be that the patients asked to a later time were already used to the plate and temporary nail deformities might have already healed.
After removal of the hook plate, the self-assessment score concerning stress-induced pain got significantly better while subjective satisfaction concerning cosmetic outcome and nail deformity got significantly worse. This might be due to the high expectations patients have concerning the metal removal. Often, nail deformities are due to an injury of the nail bed, which might be irreparably injured or healing takes a long time and cannot be accelerated by metal removal. Moreover, postoperative swelling and reddening of the distal phalanx might still have been present. Finally, some patients still have a deficiency concerning maximum extension of the finger.
The SF-36 score is widely acknowledged as a life quality score used generally in all studies concerning satisfaction and personnel happiness after trauma or surgery of the upper extremities [31, 32]. However, it does not seem to be a reasonable questionnaire for analyzing this special outcome in the phalangeal area. It is far too unspecific as only one finger is concerned. In our collective, we could find more or less no difference in the scores of our collective compared with the standardized comparison group of the American individual. All individuals achieved around about 50 points. Regarding the single questions in detail, not all of them were really satisfied with the finger, which of course also has a certain impact on life quality.
However, this study has some limitations. First, we could enroll only 44 patients, which is good compared to other published studies, but further studies with more patients are needed for improvement of statistical power. Moreover, we could show only a few significant results, which might be due to the small patient number.

Conclusions

In conclusion, the hook plate is a reliable and safe method for treatment of bony avulsion fractures of the distal phalanx as several authors have shown before. Concerning the subjective satisfaction of the patient, the results [2, 17, 30] are good to excellent with only two deficits, which are the cosmetic outcome and the nail deformity. Patients should be informed about this during the informative conversation before giving their informed consent.

Authors’ contributions

HV has designed the study and the questionnaire, has enrolled the patients, has interpreted the data, and has written the manuscript. LS has performed the analysis of the questionnaires and the data. FvM has helped with the database, the data interpretation, and the manuscript. MB has helped designing the questionnaire. MvG contributed to the study design, the interpretation of the data, and the writing of the manuscript. SD has helped enrolling the patients and designing the score. All the authors read and approved the final manuscript.

Acknowledgements

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Not applicable.
The local ethical review committee of the Faculty of Medicine of the Technical University of Munich approved this study (369/14).

Funding

No funding has been received.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Salazar Botero S, Hidalgo Diaz JJ, Benaida A, Collon S, Facca S, Liverneaux PA. Review of acute traumatic closed mallet finger injuries in adults. Arch Plast Surg. 2016;43:134–44.CrossRefPubMedPubMedCentral Salazar Botero S, Hidalgo Diaz JJ, Benaida A, Collon S, Facca S, Liverneaux PA. Review of acute traumatic closed mallet finger injuries in adults. Arch Plast Surg. 2016;43:134–44.CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Teoh LC, Lee JY. Mallet fractures: a novel approach to internal fixation using a hook plate. J Hand Surg Eur. 2007;32:24–30.CrossRef Teoh LC, Lee JY. Mallet fractures: a novel approach to internal fixation using a hook plate. J Hand Surg Eur. 2007;32:24–30.CrossRef
4.
Zurück zum Zitat Ishiguro T, Itoh Y, Yabe Y, Hashizume N. Operation des dislozierten knöchernen Strecksehnenausrisses an den Langfingern. Operative Orthopädie und Traumatologie. 1999;11:107–13.CrossRefPubMed Ishiguro T, Itoh Y, Yabe Y, Hashizume N. Operation des dislozierten knöchernen Strecksehnenausrisses an den Langfingern. Operative Orthopädie und Traumatologie. 1999;11:107–13.CrossRefPubMed
5.
Zurück zum Zitat Hofmeister EP, Mazurek MT, Shin AY, Bishop AT. Extension block pinning for large mallet fractures. J Hand Surg. 2003;28:453–9.CrossRef Hofmeister EP, Mazurek MT, Shin AY, Bishop AT. Extension block pinning for large mallet fractures. J Hand Surg. 2003;28:453–9.CrossRef
6.
Zurück zum Zitat Kronlage SC, Faust D. Open reduction and screw fixation of mallet fractures. J Hand Surg Br. 2004;29:135–8.CrossRefPubMed Kronlage SC, Faust D. Open reduction and screw fixation of mallet fractures. J Hand Surg Br. 2004;29:135–8.CrossRefPubMed
7.
Zurück zum Zitat Yamanaka K, Sasaki T. Treatment of mallet fractures using compression fixation pins. J Hand Surg Br Eur. 1999;24:358–60.CrossRef Yamanaka K, Sasaki T. Treatment of mallet fractures using compression fixation pins. J Hand Surg Br Eur. 1999;24:358–60.CrossRef
8.
Zurück zum Zitat Jupiter JB, Sheppard JE. Tension wire fixation of avulsion fractures in the hand. Clin Orthop Relat Res. 1987;214:113–20. Jupiter JB, Sheppard JE. Tension wire fixation of avulsion fractures in the hand. Clin Orthop Relat Res. 1987;214:113–20.
9.
Zurück zum Zitat Zhang X, Meng H, Shao X, Wen S, Zhu H, Mi X. Pull-out wire fixation for acute mallet finger fractures with k-wire stabilization of the distal interphalangeal joint. J Hand Surg Am. 2010;35:1864–9.CrossRefPubMed Zhang X, Meng H, Shao X, Wen S, Zhu H, Mi X. Pull-out wire fixation for acute mallet finger fractures with k-wire stabilization of the distal interphalangeal joint. J Hand Surg Am. 2010;35:1864–9.CrossRefPubMed
10.
Zurück zum Zitat Bischoff R, Buechler U, De Roche R, Jupiter J. Clinical results of tension band fixation of avulsion fractures of the hand. J Hand Surg Am. 1994;19:1019–26.CrossRefPubMed Bischoff R, Buechler U, De Roche R, Jupiter J. Clinical results of tension band fixation of avulsion fractures of the hand. J Hand Surg Am. 1994;19:1019–26.CrossRefPubMed
11.
Zurück zum Zitat Damron TA, Engber WD. Surgical treatment of mallet finger fractures by tension band technique. Clin Orthop Relat Res. 1994;300:133–40. Damron TA, Engber WD. Surgical treatment of mallet finger fractures by tension band technique. Clin Orthop Relat Res. 1994;300:133–40.
12.
Zurück zum Zitat Ender HG, Hintringer W. Die perkutane Versorgung von knöchernen Ausrissen der Strecksehnen und Seitenbänder an den Fingern mit dem „Hakendraht”. Unfallchirurgie. 1986;12:143–7.CrossRefPubMed Ender HG, Hintringer W. Die perkutane Versorgung von knöchernen Ausrissen der Strecksehnen und Seitenbänder an den Fingern mit dem „Hakendraht”. Unfallchirurgie. 1986;12:143–7.CrossRefPubMed
13.
Zurück zum Zitat Rocchi L, Genitiempo M, Fanfani F. Percutaneous fixation of mallet fractures by the “umbrella handle” technique. J Hand Surg Br. 2006;31:407–12.CrossRefPubMed Rocchi L, Genitiempo M, Fanfani F. Percutaneous fixation of mallet fractures by the “umbrella handle” technique. J Hand Surg Br. 2006;31:407–12.CrossRefPubMed
14.
Zurück zum Zitat Chung DW, Lee JH. Anatomic reduction of mallet fractures using extension block and additional intrafocal pinning techniques. Clin Orthop Surg. 2012;4:72–6.CrossRefPubMedPubMedCentral Chung DW, Lee JH. Anatomic reduction of mallet fractures using extension block and additional intrafocal pinning techniques. Clin Orthop Surg. 2012;4:72–6.CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Shimura H, Wakabayashi Y, Nimura A. A novel closed reduction with extension block and flexion block using Kirschner wires and microscrew fixation for mallet fractures. J Orthop Sci. 2014;19:308–12.CrossRefPubMedPubMedCentral Shimura H, Wakabayashi Y, Nimura A. A novel closed reduction with extension block and flexion block using Kirschner wires and microscrew fixation for mallet fractures. J Orthop Sci. 2014;19:308–12.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Tetik C, Gudemez E. Modification of the extension block Kirschner wire technique for mallet fractures. Clin Orthop Relat Res. 2002;404:284–90.CrossRef Tetik C, Gudemez E. Modification of the extension block Kirschner wire technique for mallet fractures. Clin Orthop Relat Res. 2002;404:284–90.CrossRef
17.
Zurück zum Zitat Szalay G, Schleicher I, Schiefer UR, Alt V, Schnettler R. Operative treatment of osseous pull out of the extensor tendon using a hook plate. Oper Orthop Traumatol. 2011;23:151–7.CrossRefPubMed Szalay G, Schleicher I, Schiefer UR, Alt V, Schnettler R. Operative treatment of osseous pull out of the extensor tendon using a hook plate. Oper Orthop Traumatol. 2011;23:151–7.CrossRefPubMed
18.
Zurück zum Zitat Yamanaka K, Sasaki T. Treatment of mallet fractures using compression fixation pins. J Hand Surg Br. 1999;24:358–60.CrossRefPubMed Yamanaka K, Sasaki T. Treatment of mallet fractures using compression fixation pins. J Hand Surg Br. 1999;24:358–60.CrossRefPubMed
19.
Zurück zum Zitat King HJ, Shin SJ, Kang ES. Complications of operative treatment for mallet fractures of the distal phalanx. J Hand Surg Br. 2001;26:28–31.CrossRefPubMed King HJ, Shin SJ, Kang ES. Complications of operative treatment for mallet fractures of the distal phalanx. J Hand Surg Br. 2001;26:28–31.CrossRefPubMed
20.
Zurück zum Zitat Chauhan A, Jacobs B, Andoga A, Baratz ME. Extensor tendon injuries in athletes. Sports Med Arthrosc Rev. 2014;22:45–55.CrossRefPubMed Chauhan A, Jacobs B, Andoga A, Baratz ME. Extensor tendon injuries in athletes. Sports Med Arthrosc Rev. 2014;22:45–55.CrossRefPubMed
21.
Zurück zum Zitat Handoll HH, Vaghela MV. Interventions for treating mallet finger injuries. Cochrane Database Syst Rev. 2004;3:CD004574. Handoll HH, Vaghela MV. Interventions for treating mallet finger injuries. Cochrane Database Syst Rev. 2004;3:CD004574.
22.
Zurück zum Zitat Schadel-Hopfner M, Logters T, Windolf J, Gehrmann S, Eisenschenk A, Junge A. Current concepts in the treatment of mallet fractures of the distal phalanx. Unfallchirurg. 2011;114:591–6.CrossRefPubMed Schadel-Hopfner M, Logters T, Windolf J, Gehrmann S, Eisenschenk A, Junge A. Current concepts in the treatment of mallet fractures of the distal phalanx. Unfallchirurg. 2011;114:591–6.CrossRefPubMed
23.
Zurück zum Zitat Takami H, Takahashi S, Ando M. Operative treatment of mallet finger due to intra-articular fracture of the distal phalanx. Arch Orthop Trauma Surg. 2000;120:9–13.CrossRefPubMed Takami H, Takahashi S, Ando M. Operative treatment of mallet finger due to intra-articular fracture of the distal phalanx. Arch Orthop Trauma Surg. 2000;120:9–13.CrossRefPubMed
24.
Zurück zum Zitat Iselin F, Levame J, Godoy J. A simplified technique for treating mallet fingers: tenodermodesis. J Hand Surg Am. 1977;2:118–21.CrossRefPubMed Iselin F, Levame J, Godoy J. A simplified technique for treating mallet fingers: tenodermodesis. J Hand Surg Am. 1977;2:118–21.CrossRefPubMed
25.
Zurück zum Zitat Fritz D, Lutz M, Arora R, Gabl M, Wambacher M, Pechlaner S. Delayed single Kirschner wire compression technique for mallet fracture. J Hand Surg Br. 2005;30:180–4.CrossRefPubMed Fritz D, Lutz M, Arora R, Gabl M, Wambacher M, Pechlaner S. Delayed single Kirschner wire compression technique for mallet fracture. J Hand Surg Br. 2005;30:180–4.CrossRefPubMed
26.
Zurück zum Zitat Hofmeister EP, Mazurek MT, Shin AY, Bishop AT. Extension block pinning for large mallet fractures. J Hand Surg Am. 2003;28:453–9.CrossRefPubMed Hofmeister EP, Mazurek MT, Shin AY, Bishop AT. Extension block pinning for large mallet fractures. J Hand Surg Am. 2003;28:453–9.CrossRefPubMed
27.
Zurück zum Zitat Kim DH, Kang HJ, Choi JW. The “Fish Hook” technique for bony mallet finger. Orthopedics. 2016;39:1–4.CrossRef Kim DH, Kang HJ, Choi JW. The “Fish Hook” technique for bony mallet finger. Orthopedics. 2016;39:1–4.CrossRef
28.
Zurück zum Zitat Kim JK, Kim DJ. The risk factors associated with subluxation of the distal interphalangeal joint in mallet fracture. J Hand Surg Eur. 2015;40:63–7.CrossRef Kim JK, Kim DJ. The risk factors associated with subluxation of the distal interphalangeal joint in mallet fracture. J Hand Surg Eur. 2015;40:63–7.CrossRef
29.
Zurück zum Zitat Pegoli L, Toh S, Arai K, Fukuda A, Nishikawa S, Vallejo IG. The Ishiguro extension block technique for the treatment of mallet finger fracture: indications and clinical results. J Hand Surg Br. 2003;28:15–7.CrossRefPubMed Pegoli L, Toh S, Arai K, Fukuda A, Nishikawa S, Vallejo IG. The Ishiguro extension block technique for the treatment of mallet finger fracture: indications and clinical results. J Hand Surg Br. 2003;28:15–7.CrossRefPubMed
30.
Zurück zum Zitat Acar MA, Guzel Y, Gulec A, Uzer G, Elmadag M. Clinical comparison of hook plate fixation versus extension block pinning for bony mallet finger: a retrospective comparison study. J Hand Surg Eur. 2015;40:832–9.CrossRef Acar MA, Guzel Y, Gulec A, Uzer G, Elmadag M. Clinical comparison of hook plate fixation versus extension block pinning for bony mallet finger: a retrospective comparison study. J Hand Surg Eur. 2015;40:832–9.CrossRef
31.
Zurück zum Zitat Patel AA, Donegan D, Albert T. The 36-item short form. J Am Acad Orthop Surg. 2007;15:126–34.CrossRefPubMed Patel AA, Donegan D, Albert T. The 36-item short form. J Am Acad Orthop Surg. 2007;15:126–34.CrossRefPubMed
32.
Zurück zum Zitat Schuind FA, Mouraux D, Robert C, Brassinne E, Remy P, Salvia P, Meyer A, Moulart F, Burny F. Functional and outcome evaluation of the hand and wrist. Hand Clin. 2003;19:361–9.CrossRefPubMed Schuind FA, Mouraux D, Robert C, Brassinne E, Remy P, Salvia P, Meyer A, Moulart F, Burny F. Functional and outcome evaluation of the hand and wrist. Hand Clin. 2003;19:361–9.CrossRefPubMed
Metadaten
Titel
Patient satisfaction after hook plate treatment of bony avulsion fracture of the distal phalanges
verfasst von
H. Vester
L. Schul
F. von Matthey
M. Beirer
M. van Griensven
S. Deiler
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
European Journal of Medical Research / Ausgabe 1/2018
Elektronische ISSN: 2047-783X
DOI
https://doi.org/10.1186/s40001-018-0332-y

Weitere Artikel der Ausgabe 1/2018

European Journal of Medical Research 1/2018 Zur Ausgabe