Skip to main content
main-content

01.05.2009 | Original | Ausgabe 5/2009

Intensive Care Medicine 5/2009

Patient–ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter study

Zeitschrift:
Intensive Care Medicine > Ausgabe 5/2009
Autoren:
Laurence Vignaux, Frédéric Vargas, Jean Roeseler, Didier Tassaux, Arnaud W. Thille, Michel P. Kossowsky, Laurent Brochard, Philippe Jolliet
Wichtige Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1007/​s00134-009-1416-5) contains supplementary material, which is available to authorized users.
This study was presented in abstract form at the 2008 Annual Meeting of the American Thoracic Society.

Abstract

Objective

To determine the prevalence of patient–ventilator asynchrony in patients receiving non-invasive ventilation (NIV) for acute respiratory failure.

Design

Prospective multicenter observation study.

Setting

Intensive care units in three university hospitals.

Methods

Patients consecutively admitted to ICU were included. NIV, performed with an ICU ventilator, was set by the clinician. Airway pressure, flow, and surface diaphragmatic electromyography were recorded continuously for 30 min. Asynchrony events and the asynchrony index (AI) were determined from visual inspection of the recordings and clinical observation.

Results

A total of 60 patients were included, 55% of whom were hypercapnic. Auto-triggering was present in 8 (13%) patients, double triggering in 9 (15%), ineffective breaths in 8 (13%), premature cycling 7 (12%) and late cycling in 14 (23%). An AI > 10%, indicating severe asynchrony, was present in 26 patients (43%), whose median (25–75 IQR) AI was 26 (15–54%). A significant correlation was found between the magnitude of leaks and the number of ineffective breaths and severity of delayed cycling. Multivariate analysis indicated that the level of pressure support and the magnitude of leaks were weakly, albeit significantly, associated with an AI > 10%. Patient comfort scale was higher in pts with an AI < 10%.

Conclusion

Patient–ventilator asynchrony is common in patients receiving NIV for acute respiratory failure. Our results suggest that leaks play a major role in generating patient–ventilator asynchrony and discomfort, and point the way to further research to determine if ventilator functions designed to cope with leaks can reduce asynchrony in the clinical setting.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag als Mediziner

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Weitere Produktempfehlungen anzeigen
Zusatzmaterial
Nur für berechtigte Nutzer zugänglich
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 5/2009

Intensive Care Medicine 5/2009 Zur Ausgabe
  1. Sie können e.Med Innere Medizin 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  2. Sie können e.Med AINS 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

Neu im Fachgebiet AINS

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update AINS und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise