Skip to main content
Erschienen in: International Urogynecology Journal 11/2020

04.06.2020 | Original Article

Pelvic floor morphology in the standing position using upright computed tomography: age and sex differences

verfasst von: Keiichi Narita, Yoshitake Yamada, Minoru Yamada, Yoichi Yokoyama, Takehiro Nakahara, Masahiro Jinzaki

Erschienen in: International Urogynecology Journal | Ausgabe 11/2020

Einloggen, um Zugang zu erhalten

Abstract

Introduction and hypothesis

This study was aimed at comparing pelvic floor parameters between the standing and supine positions using upright computed tomography (CT) and evaluating the effects of sex and age in normal healthy volunteers.

Methods

In total, 139 volunteers (70 men, mean 46.7 years; 69 women, mean 47.3 years) underwent both upright CT in the standing position and conventional CT in the supine position. The distances from the bladder neck to the pubococcygeal line (PCL) and anorectal junction (ARJ), defined as the posterior aspect of the puborectalis muscle, to PCL were measured. The length, width, and area of the levator hiatus (LH) were measured on oblique axial images.

Results

The bladder neck (men, 22.2 ± 4.9 mm vs 28.3 ± 5.3 mm; women, 9.0 ± 5.1 mm vs 19.0 ± 4.0 mm) and ARJ (men, −18.8 ± 5.5 mm vs −12.1 ± 5.1 mm; women, −20.0 ± 4.7 mm vs −11.2 ± 4.3 mm) were significantly lower in the standing position than in the supine position (all p < 0.0001). The LH area (men, 1,990 ± 380 mm2 vs 1,697 ± 329 mm2; women, 2,284 ± 344 mm2 vs 1,811 ± 261 mm2) was significantly larger in the standing position (both p < 0.0001). Differences in all parameters between the standing and supine positions were larger in women than in men. ARJ in women showed a significant tendency to descend with age only in the standing position (r = −0.29, p = 0.017).

Conclusions

The bladder neck and ARJ descend and the LH area enlarges in the standing position. Pelvic floor mobility is greater in women than in men. Descent of the ARJ in the standing position is associated with aging in women.
Literatur
5.
Zurück zum Zitat Jinzaki M, Yamada Y, Nagura T, Nakahara T, Yokoyama Y, Narita K, et al. Development of upright computed tomography with area detector for whole-body scans: phantom study, efficacy on workflow, effect of gravity on human body, and potential clinical impact. Investig Radiol. 2020;55:73–83. https://doi.org/10.1097/RLI.0000000000000603.CrossRef Jinzaki M, Yamada Y, Nagura T, Nakahara T, Yokoyama Y, Narita K, et al. Development of upright computed tomography with area detector for whole-body scans: phantom study, efficacy on workflow, effect of gravity on human body, and potential clinical impact. Investig Radiol. 2020;55:73–83. https://​doi.​org/​10.​1097/​RLI.​0000000000000603​.CrossRef
6.
Zurück zum Zitat MacLennan AH, Taylor AW, Wilson DH, Wilson D. The prevalence of pelvic floor disorders and their relationship to gender, age, parity and mode of delivery. BJOG. 2000;107:1460–70. MacLennan AH, Taylor AW, Wilson DH, Wilson D. The prevalence of pelvic floor disorders and their relationship to gender, age, parity and mode of delivery. BJOG. 2000;107:1460–70.
7.
Zurück zum Zitat Yamada Y, Yamada M, Yokoyama Y, Tanabe A, Matsuoka S, Niijima Y, et al. Differences in lung and lobe volumes between supine and standing positions scanned with conventional and newly developed 320-detector-row upright CT: intra-individual comparison. Respiration. 2020. https://doi.org/10.1159/000507265.CrossRef Yamada Y, Yamada M, Yokoyama Y, Tanabe A, Matsuoka S, Niijima Y, et al. Differences in lung and lobe volumes between supine and standing positions scanned with conventional and newly developed 320-detector-row upright CT: intra-individual comparison. Respiration. 2020. https://​doi.​org/​10.​1159/​000507265.CrossRef
11.
Zurück zum Zitat Barbaric ZL, Marumoto AK, Raz S. Magnetic resonance imaging of the perineum and pelvic floor. Top Magn Reson Imaging. 2001;12:83–92. Barbaric ZL, Marumoto AK, Raz S. Magnetic resonance imaging of the perineum and pelvic floor. Top Magn Reson Imaging. 2001;12:83–92.
22.
23.
Zurück zum Zitat Mouritsen L, Bach P. Ultrasonic evaluation of bladder neck position and mobility: the influence of urethral catheter, bladder volume, and body position. Neurourol Urodyn. 1994;13:637–46. Mouritsen L, Bach P. Ultrasonic evaluation of bladder neck position and mobility: the influence of urethral catheter, bladder volume, and body position. Neurourol Urodyn. 1994;13:637–46.
28.
Zurück zum Zitat Howard D, Delancey JO, Tunn R, Ashton-Miller JA. Racial differences in the structure and function of the stress urinary continence mechanism. Obstet Gynecol. 2000;95:713–7. Howard D, Delancey JO, Tunn R, Ashton-Miller JA. Racial differences in the structure and function of the stress urinary continence mechanism. Obstet Gynecol. 2000;95:713–7.
Metadaten
Titel
Pelvic floor morphology in the standing position using upright computed tomography: age and sex differences
verfasst von
Keiichi Narita
Yoshitake Yamada
Minoru Yamada
Yoichi Yokoyama
Takehiro Nakahara
Masahiro Jinzaki
Publikationsdatum
04.06.2020
Verlag
Springer International Publishing
Erschienen in
International Urogynecology Journal / Ausgabe 11/2020
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-020-04335-z

Weitere Artikel der Ausgabe 11/2020

International Urogynecology Journal 11/2020 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.