Performance of closed-loop resuscitation in a pig model of haemorrhagic shock with fluid alone or in combination with norepinephrine, a pilot study

verfasst von: Nicolas Libert, Guillaume Chenegros, Anatole Harrois, Nathalie Baudry, Benoit Decante, Gilles Cordurie, Ryad Benosman, Olaf Mercier, Eric Vicaut, Jacques Duranteau

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2021

Einloggen, um Zugang zu erhalten

Abstract

We evaluated the performance of a new device to control the administration of fluid alone or co-administration of fluid and norepinephrine in a pig model of haemorrhagic shock in two sets of experiments. In the first one, resuscitation was guided using continuous arterial pressure measurements (three groups: resuscitation with fluid by a physician, CL resuscitation with fluid, and CL resuscitation with fluid and norepinephrine). In the second one, resuscitation was guided using discontinuous arterial pressure measurements (three groups: CL resuscitation with fluid alone, CL resuscitation with fluid and moderate dose norepinephrine, and CL resuscitation with fluid and a high dose of norepinephrine). Pigs were resuscitated for 1 h. In the first set of experiments, proportion of time spent in the target area of 78–88 mmHg of systolic arterial pressure was not statistically different between the three groups: manual, 71.2% (39.1–80.1); CL with fluid, 87.8% (68.3–97.4); and CL with fluid and norepinephrine, 78.1% (59.2–83.6), p = 0.151. In the second set of experiments, performance of CL resuscitation with fluid or with combination of fluid and high or moderate dose of norepinephrine was not significantly different (p = 0.543 for time in target). Pigs resuscitated with norepinephrine required less fluid and had less haemodilution than pigs resuscitated with fluid alone. Performance of CL resuscitation using continuous arterial pressure measurement was not significantly different than optimised manual treatment by a dedicated physician. Performance of CL resuscitation was reduced with discontinuous arterial pressure measurements in comparison with continuous arterial pressure measurements.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Rossaint R, Bouillon B, Cerny V, Coats TJ, Duranteau J, Fernandez-Mondejar E, et al. The European guideline on management of major bleeding and coagulopathy following trauma: fourth edition. Crit Care. 2016;20:100.CrossRef Rossaint R, Bouillon B, Cerny V, Coats TJ, Duranteau J, Fernandez-Mondejar E, et al. The European guideline on management of major bleeding and coagulopathy following trauma: fourth edition. Crit Care. 2016;20:100.CrossRef
2.
Zurück zum Zitat Kramer GC, Kinsky MP, Prough DS, Salinas J, Sondeen JL, Hazel-Scerbo ML, et al. Closed-loop control of fluid therapy for treatment of hypovolemia. J Trauma. 2008;64(4 Suppl):S333–S34141.PubMed Kramer GC, Kinsky MP, Prough DS, Salinas J, Sondeen JL, Hazel-Scerbo ML, et al. Closed-loop control of fluid therapy for treatment of hypovolemia. J Trauma. 2008;64(4 Suppl):S333–S34141.PubMed
3.
Zurück zum Zitat Salinas J, Chung KK, Mann EA, Cancio LC, Kramer GC, Serio-Melvin ML, et al. Computerized decision support system improves fluid resuscitation following severe burns: an original study. Crit Care Med. 2011;39(9):2031–8.CrossRef Salinas J, Chung KK, Mann EA, Cancio LC, Kramer GC, Serio-Melvin ML, et al. Computerized decision support system improves fluid resuscitation following severe burns: an original study. Crit Care Med. 2011;39(9):2031–8.CrossRef
4.
Zurück zum Zitat Ying H, Bonnerup C, Kirschner R, Deyo D, Michell M, Kramer G (2002) (eds) Closed-loop fuzzy control of resuscitation of hemorrhagic shock in sheep. Engineering in Medicine and Biology, 2002 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002 Proceedings of the Second Joint; 2002: IEEE. Ying H, Bonnerup C, Kirschner R, Deyo D, Michell M, Kramer G (2002) (eds) Closed-loop fuzzy control of resuscitation of hemorrhagic shock in sheep. Engineering in Medicine and Biology, 2002 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002 Proceedings of the Second Joint; 2002: IEEE.
5.
Zurück zum Zitat Joosten A, Alexander B, Duranteau J, Taccone FS, Creteur J, Vincent JL, et al. Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk surgery. Br J Anaesth. 2019;123(4):430–8.CrossRef Joosten A, Alexander B, Duranteau J, Taccone FS, Creteur J, Vincent JL, et al. Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk surgery. Br J Anaesth. 2019;123(4):430–8.CrossRef
6.
Zurück zum Zitat Joosten A, Delaporte A, Alexander B, Su F, Creteur J, Vincent JL, et al. Automated titration of vasopressor infusion using a closed-loop controller: in vivo feasibility study using a swine model. Anesthesiology. 2019;130(3):394–403.CrossRef Joosten A, Delaporte A, Alexander B, Su F, Creteur J, Vincent JL, et al. Automated titration of vasopressor infusion using a closed-loop controller: in vivo feasibility study using a swine model. Anesthesiology. 2019;130(3):394–403.CrossRef
7.
Zurück zum Zitat Rinehart J, Joosten A, Ma M, Calderon MD, Cannesson M. Closed-loop vasopressor control: in-silico study of robustness against pharmacodynamic variability. J Clin Monit Comput. 2019;33(5):795–802.CrossRef Rinehart J, Joosten A, Ma M, Calderon MD, Cannesson M. Closed-loop vasopressor control: in-silico study of robustness against pharmacodynamic variability. J Clin Monit Comput. 2019;33(5):795–802.CrossRef
8.
Zurück zum Zitat Rinehart J, Lee C, Canales C, Kong A, Kain Z, Cannesson M. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study. Anesth Analg. 2013;117(5):1119–29.CrossRef Rinehart J, Lee C, Canales C, Kong A, Kain Z, Cannesson M. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study. Anesth Analg. 2013;117(5):1119–29.CrossRef
9.
Zurück zum Zitat Marques NR, Whitehead WE, Kallu UR, Kinsky MP, Funston JS, Wassar T, et al. Physician-directed versus computerized closed-loop control of blood pressure using phenylephrine in a Swine model. Anesth Analg. 2017;125(1):110–6.CrossRef Marques NR, Whitehead WE, Kallu UR, Kinsky MP, Funston JS, Wassar T, et al. Physician-directed versus computerized closed-loop control of blood pressure using phenylephrine in a Swine model. Anesth Analg. 2017;125(1):110–6.CrossRef
10.
Zurück zum Zitat Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest. 2003;124(5):1900–8.CrossRef Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest. 2003;124(5):1900–8.CrossRef
11.
Zurück zum Zitat Hofer CK, Furrer L, Matter-Ensner S, Maloigne M, Klaghofer R, Genoni M, et al. Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth. 2005;94(6):748–55.CrossRef Hofer CK, Furrer L, Matter-Ensner S, Maloigne M, Klaghofer R, Genoni M, et al. Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth. 2005;94(6):748–55.CrossRef
12.
Zurück zum Zitat Wiggers CJ. The present status of the shock problem. Physiol Rev. 1942;22:74–123.CrossRef Wiggers CJ. The present status of the shock problem. Physiol Rev. 1942;22:74–123.CrossRef
13.
Zurück zum Zitat Daye P, Ieng SH, Benosman R. A Theory for sparse event-based closed loop control. Front Neurosci. 2019;13:827.CrossRef Daye P, Ieng SH, Benosman R. A Theory for sparse event-based closed loop control. Front Neurosci. 2019;13:827.CrossRef
14.
Zurück zum Zitat Libert N, Chenegros G, Harrois A, Baudry N, Cordurie G, Benosman R, et al. Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study. Ann Intensive Care. 2018;8(1):89.CrossRef Libert N, Chenegros G, Harrois A, Baudry N, Cordurie G, Benosman R, et al. Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study. Ann Intensive Care. 2018;8(1):89.CrossRef
15.
Zurück zum Zitat Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC. Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma. 2003;54(5 Suppl):S183–S192192.PubMed Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC. Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma. 2003;54(5 Suppl):S183–S192192.PubMed
16.
Zurück zum Zitat Rafie AD, Rath PA, Michell MW, Kirschner RA, Deyo DJ, Prough DS, et al. Hypotensive resuscitation of multiple hemorrhages using crystalloid and colloids. Shock. 2004;22(3):262–9.CrossRef Rafie AD, Rath PA, Michell MW, Kirschner RA, Deyo DJ, Prough DS, et al. Hypotensive resuscitation of multiple hemorrhages using crystalloid and colloids. Shock. 2004;22(3):262–9.CrossRef
17.
Zurück zum Zitat Do Nascimento P Jr, Vaid SU, Hoskins SL, Espana JM, Kinsky MP, Kramer GC. Hypertonic 15% sodium pyruvate offers no initial resuscitation advantage compared with 8% hypertonic NACl in sheep with multiple hemorrhages. Shock. 2007;27(5):565–71.CrossRef Do Nascimento P Jr, Vaid SU, Hoskins SL, Espana JM, Kinsky MP, Kramer GC. Hypertonic 15% sodium pyruvate offers no initial resuscitation advantage compared with 8% hypertonic NACl in sheep with multiple hemorrhages. Shock. 2007;27(5):565–71.CrossRef
18.
Zurück zum Zitat Vaid SU, Shah A, Michell MW, Rafie AD, Deyo DJ, Prough DS, et al. Normotensive and hypotensive closed-loop resuscitation using 3.0% NaCl to treat multiple hemorrhages in sheep. Crit Care Med. 2006;34(4):1185–92.CrossRef Vaid SU, Shah A, Michell MW, Rafie AD, Deyo DJ, Prough DS, et al. Normotensive and hypotensive closed-loop resuscitation using 3.0% NaCl to treat multiple hemorrhages in sheep. Crit Care Med. 2006;34(4):1185–92.CrossRef
19.
Zurück zum Zitat Marques NR, Ford BJ, Khan MN, Kinsky M, Deyo DJ, Mileski WJ, et al. Automated closed-loop resuscitation of multiple hemorrhages: a comparison between fuzzy logic and decision table controllers in a sheep model. Disaster Mil Med. 2017;3:1.CrossRef Marques NR, Ford BJ, Khan MN, Kinsky M, Deyo DJ, Mileski WJ, et al. Automated closed-loop resuscitation of multiple hemorrhages: a comparison between fuzzy logic and decision table controllers in a sheep model. Disaster Mil Med. 2017;3:1.CrossRef
20.
Zurück zum Zitat Varvel JR, Donoho DL, Shafer SL. Measuring the predictive performance of computer-controlled infusion pumps. J Pharmacokinet Biopharm. 1992;20(1):63–94.CrossRef Varvel JR, Donoho DL, Shafer SL. Measuring the predictive performance of computer-controlled infusion pumps. J Pharmacokinet Biopharm. 1992;20(1):63–94.CrossRef
21.
Zurück zum Zitat Sng BL, Wang H, Assam PN, Sia AT. Assessment of an updated double-vasopressor automated system using Nexfin for the maintenance of haemodynamic stability to improve peri-operative outcome during spinal anaesthesia for caesarean section. Anaesthesia. 2015;70(6):691–8.CrossRef Sng BL, Wang H, Assam PN, Sia AT. Assessment of an updated double-vasopressor automated system using Nexfin for the maintenance of haemodynamic stability to improve peri-operative outcome during spinal anaesthesia for caesarean section. Anaesthesia. 2015;70(6):691–8.CrossRef
22.
Zurück zum Zitat Ngan Kee WD, Khaw KS, Tam YH, Ng FF, Lee SW. Performance of a closed-loop feedback computer-controlled infusion system for maintaining blood pressure during spinal anaesthesia for caesarean section: a randomized controlled comparison of norepinephrine versus phenylephrine. J Clin Monit Comput. 2017;31(3):617–23.CrossRef Ngan Kee WD, Khaw KS, Tam YH, Ng FF, Lee SW. Performance of a closed-loop feedback computer-controlled infusion system for maintaining blood pressure during spinal anaesthesia for caesarean section: a randomized controlled comparison of norepinephrine versus phenylephrine. J Clin Monit Comput. 2017;31(3):617–23.CrossRef
23.
Zurück zum Zitat Ngan Kee WD, Tam YH, Khaw KS, Ng FF, Critchley LA, Karmakar MK. Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study. Anaesthesia. 2007;62(12):1251–6.CrossRef Ngan Kee WD, Tam YH, Khaw KS, Ng FF, Critchley LA, Karmakar MK. Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study. Anaesthesia. 2007;62(12):1251–6.CrossRef
24.
Zurück zum Zitat Kashihara K, Kawada T, Uemura K, Sugimachi M, Sunagawa K. Adaptive predictive control of arterial blood pressure based on a neural network during acute hypotension. Ann Biomed Eng. 2004;32(10):1365–83.CrossRef Kashihara K, Kawada T, Uemura K, Sugimachi M, Sunagawa K. Adaptive predictive control of arterial blood pressure based on a neural network during acute hypotension. Ann Biomed Eng. 2004;32(10):1365–83.CrossRef
25.
Zurück zum Zitat Uemura K, Kawada T, Zheng C, Li M, Sugimachi M. Computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in endotoxin-induced shock. BMC Anesthesiol. 2017;17(1):145.CrossRef Uemura K, Kawada T, Zheng C, Li M, Sugimachi M. Computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in endotoxin-induced shock. BMC Anesthesiol. 2017;17(1):145.CrossRef
Metadaten
Titel
Performance of closed-loop resuscitation in a pig model of haemorrhagic shock with fluid alone or in combination with norepinephrine, a pilot study
verfasst von
Nicolas Libert
Guillaume Chenegros
Anatole Harrois
Nathalie Baudry
Benoit Decante
Gilles Cordurie
Ryad Benosman
Olaf Mercier
Eric Vicaut
Jacques Duranteau
Publikationsdatum
12.06.2020
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2021
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00542-7

Weitere Artikel der Ausgabe 4/2021

Journal of Clinical Monitoring and Computing 4/2021 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.