Purpose

Although ultrasound has been widely used to evaluate transjugular intrahepatic portosystemic shunts (TIPS) patency, several studies have reported conflicting data regarding its performance. Therefore, we aimed to evaluate performance of ultrasound for detection of TIPS dysfunction by performing a meta-analysis.

Methods

Literature search was performed for studies evaluating ultrasound for TIPS dysfunction, stenosis, and occlusion using PubMed, EMBASE, Scopus, and Cochrane Library through February 2019. Pooled sensitivity, specificity, log diagnostic odds ratio (LDOR), and area under curve (AUC) of summary receiver-operating characteristic were calculated. Subgroup analyses were performed according to ultrasonographic criteria and type of stent.

Results

In total, 21 studies were evaluated. Pooled sensitivity, specificity, and LDOR of ultrasound for detection of TIPS dysfunction were 0.82 (0.67, 0.93), 0.58 (0.46, 0.70), and 1.77 (1.20, 2.35). Pooled sensitivity, specificity, and LDOR for TIPS stenosis were 0.80 (0.69, 0.90), 0.80 (0.69, 0.91), and 2.83 (1.88, 3.78). Pooled sensitivity, specificity, and LDOR for TIPS occlusion were 0.96 (0.92, 0.99), 1 (0.99, 1.00), and 6.28 (4.96, 7.60). AUCs of ultrasound for TIPS dysfunction, stenosis, and occlusion were 0.77, 0.86, and 0.95, respectively.

Conclusions

Although ultrasound had excellent performance for TIPS occlusion and acceptable performance for TIP stenosis, most studies utilized bare metal stent, and therefore, application to current practice is limited. Ultrasound for TIPS dysfunction in the setting of covered metal stent appeared to have acceptable sensitivity of 0.82, but limited specificity of 0.58 and low LDOR of 1.77. A new noninvasive tool is needed for detection of TIPS dysfunction in the era of covered metal stent.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Foshager, M.C., et al., Duplex sonography after transjugular intrahepatic portosystemic shunts (TIPS): normal hemodynamic findings and efficacy in predicting shunt patency and stenosis. AJR Am J Roentgenol, 1995. 165(1): p. 1-7.CrossRefPubMed Foshager, M.C., et al., Duplex sonography after transjugular intrahepatic portosystemic shunts (TIPS): normal hemodynamic findings and efficacy in predicting shunt patency and stenosis. AJR Am J Roentgenol, 1995. 165(1): p. 1-7.CrossRefPubMed
2.
Zurück zum Zitat Bureau, C., et al., Patency of stents covered with polytetrafluoroethylene in patients treated by transjugular intrahepatic portosystemic shunts: long-term results of a randomized multicentre study. Liver International, 2007. 27(6): p. 742-747.CrossRefPubMed Bureau, C., et al., Patency of stents covered with polytetrafluoroethylene in patients treated by transjugular intrahepatic portosystemic shunts: long-term results of a randomized multicentre study. Liver International, 2007. 27(6): p. 742-747.CrossRefPubMed
3.
Zurück zum Zitat Perarnau, J.M., et al., Covered vs. uncovered stents for transjugular intrahepatic portosystemic shunt: a randomized controlled trial. Journal of hepatology, 2014. 60(5): p. 962-968. Perarnau, J.M., et al., Covered vs. uncovered stents for transjugular intrahepatic portosystemic shunt: a randomized controlled trial. Journal of hepatology, 2014. 60(5): p. 962-968.
4.
Zurück zum Zitat Cura, M., et al., Causes of TIPS dysfunction. American Journal of Roentgenology, 2008. 191(6): p. 1751-1757.CrossRefPubMed Cura, M., et al., Causes of TIPS dysfunction. American Journal of Roentgenology, 2008. 191(6): p. 1751-1757.CrossRefPubMed
5.
Zurück zum Zitat Abraldes, J.G., et al., Utility of color Doppler ultrasonography predicting tips dysfunction. Am J Gastroenterol, 2005. 100(12): p. 2696-701.CrossRefPubMed Abraldes, J.G., et al., Utility of color Doppler ultrasonography predicting tips dysfunction. Am J Gastroenterol, 2005. 100(12): p. 2696-701.CrossRefPubMed
6.
Zurück zum Zitat Benito, A., et al., Doppler ultrasound for TIPS: does it work? Abdom Imaging, 2004. 29(1): p. 45-52.CrossRefPubMed Benito, A., et al., Doppler ultrasound for TIPS: does it work? Abdom Imaging, 2004. 29(1): p. 45-52.CrossRefPubMed
7.
Zurück zum Zitat Middleton, W.D., S.A. Teefey, and M.D. Darcy, Doppler evaluation of transjugular intrahepatic portosystemic shunts. Ultrasound Q, 2003. 19(2): p. 56-70; quiz 108 - 10. Middleton, W.D., S.A. Teefey, and M.D. Darcy, Doppler evaluation of transjugular intrahepatic portosystemic shunts. Ultrasound Q, 2003. 19(2): p. 56-70; quiz 108 - 10.
8.
Zurück zum Zitat Feldstein, V.A., M.D. Patel, and J.M. LaBerge, Transjugular intrahepatic portosystemic shunts: accuracy of Doppler US in determination of patency and detection of stenoses. Radiology, 1996. 201(1): p. 141-7.CrossRefPubMed Feldstein, V.A., M.D. Patel, and J.M. LaBerge, Transjugular intrahepatic portosystemic shunts: accuracy of Doppler US in determination of patency and detection of stenoses. Radiology, 1996. 201(1): p. 141-7.CrossRefPubMed
9.
Zurück zum Zitat Owens, C.A., et al., The inaccuracy of duplex ultrasonography in predicting patency of transjugular intrahepatic portosystemic shunts. Gastroenterology, 1998. 114(5): p. 975-980.CrossRefPubMed Owens, C.A., et al., The inaccuracy of duplex ultrasonography in predicting patency of transjugular intrahepatic portosystemic shunts. Gastroenterology, 1998. 114(5): p. 975-980.CrossRefPubMed
10.
Zurück zum Zitat Macaskill, P., et al., Cochrane handbook for systematic reviews of diagnostic test accuracy. Version 0.9. 0. London: The Cochrane Collaboration, 2010. Macaskill, P., et al., Cochrane handbook for systematic reviews of diagnostic test accuracy. Version 0.9. 0. London: The Cochrane Collaboration, 2010.
11.
12.
Zurück zum Zitat Whiting, P.F., et al., QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Annals of internal medicine, 2011. 155(8): p. 529-536.CrossRefPubMed Whiting, P.F., et al., QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Annals of internal medicine, 2011. 155(8): p. 529-536.CrossRefPubMed
13.
Zurück zum Zitat Fluss, R., D. Faraggi, and B. Reiser, Estimation of the Youden Index and its associated cutoff point. Biometrical Journal: Journal of Mathematical Methods in Biosciences, 2005. 47(4): p. 458-472.CrossRef Fluss, R., D. Faraggi, and B. Reiser, Estimation of the Youden Index and its associated cutoff point. Biometrical Journal: Journal of Mathematical Methods in Biosciences, 2005. 47(4): p. 458-472.CrossRef
14.
Zurück zum Zitat DerSimonian, R. and N. Laird, Meta-analysis in clinical trials. Control Clin Trials, 1986. 7(3): p. 177-88.CrossRefPubMed DerSimonian, R. and N. Laird, Meta-analysis in clinical trials. Control Clin Trials, 1986. 7(3): p. 177-88.CrossRefPubMed
15.
Zurück zum Zitat Reitsma, J.B., et al., Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. J Clin Epidemiol, 2005. 58(10): p. 982-90.CrossRefPubMed Reitsma, J.B., et al., Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. J Clin Epidemiol, 2005. 58(10): p. 982-90.CrossRefPubMed
16.
Zurück zum Zitat Walter, S.D., The partial area under the summary ROC curve. Stat Med, 2005. 24(13): p. 2025-40.CrossRefPubMed Walter, S.D., The partial area under the summary ROC curve. Stat Med, 2005. 24(13): p. 2025-40.CrossRefPubMed
17.
Zurück zum Zitat Deeks, J.J., P. Macaskill, and L. Irwig, The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol, 2005. 58(9): p. 882-93.CrossRefPubMed Deeks, J.J., P. Macaskill, and L. Irwig, The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol, 2005. 58(9): p. 882-93.CrossRefPubMed
18.
Zurück zum Zitat Haskal, Z.J., et al., Sonography of Transjugular Intrahepatic Portosystemic Shunts: Detection of Elevated Portosystemic Gradients and Loss of Shunt Function. Journal of Vascular and Interventional Radiology, 1997. 8(4): p. 549-556.CrossRefPubMed Haskal, Z.J., et al., Sonography of Transjugular Intrahepatic Portosystemic Shunts: Detection of Elevated Portosystemic Gradients and Loss of Shunt Function. Journal of Vascular and Interventional Radiology, 1997. 8(4): p. 549-556.CrossRefPubMed
19.
Zurück zum Zitat Uggowitzer, M.M., et al., Value of echo-enhanced Doppler sonography in evaluation of transjugular intrahepatic portosystemic shunts. AJR Am J Roentgenol, 1998. 170(4): p. 1041-6.CrossRefPubMed Uggowitzer, M.M., et al., Value of echo-enhanced Doppler sonography in evaluation of transjugular intrahepatic portosystemic shunts. AJR Am J Roentgenol, 1998. 170(4): p. 1041-6.CrossRefPubMed
20.
Zurück zum Zitat Fanelli, F., et al., Multidetector-row computed tomography in the evaluation of transjugular intrahepatic portosystemic shunt performed with expanded-polytetrafluoroethylene-covered stent-graft. Cardiovasc Intervent Radiol, 2011. 34(1): p. 100-5.CrossRefPubMed Fanelli, F., et al., Multidetector-row computed tomography in the evaluation of transjugular intrahepatic portosystemic shunt performed with expanded-polytetrafluoroethylene-covered stent-graft. Cardiovasc Intervent Radiol, 2011. 34(1): p. 100-5.CrossRefPubMed
21.
Zurück zum Zitat Engstrom, B.I., et al., Covered transjugular intrahepatic portosystemic shunts: accuracy of ultrasound in detecting shunt malfunction. AJR Am J Roentgenol, 2013. 200(4): p. 904-8.CrossRefPubMed Engstrom, B.I., et al., Covered transjugular intrahepatic portosystemic shunts: accuracy of ultrasound in detecting shunt malfunction. AJR Am J Roentgenol, 2013. 200(4): p. 904-8.CrossRefPubMed
22.
Zurück zum Zitat Owen, J.M. and R.C. Gaba, Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography. J Clin Imaging Sci, 2016. 6: p. 29.CrossRefPubMedPubMedCentral Owen, J.M. and R.C. Gaba, Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography. J Clin Imaging Sci, 2016. 6: p. 29.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Micol, C., et al., Contrast-enhanced ultrasound: a new method for TIPS follow-up. Abdom Imaging, 2012. 37(2): p. 252-60.CrossRefPubMed Micol, C., et al., Contrast-enhanced ultrasound: a new method for TIPS follow-up. Abdom Imaging, 2012. 37(2): p. 252-60.CrossRefPubMed
24.
Zurück zum Zitat Chong, W.K., et al., Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity. Radiology, 1993. 189(3): p. 789-93.CrossRefPubMed Chong, W.K., et al., Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity. Radiology, 1993. 189(3): p. 789-93.CrossRefPubMed
25.
Zurück zum Zitat Dodd, G.D., 3rd, et al., Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex Doppler sonography. AJR Am J Roentgenol, 1995. 164(5): p. 1119-24.CrossRefPubMed Dodd, G.D., 3rd, et al., Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex Doppler sonography. AJR Am J Roentgenol, 1995. 164(5): p. 1119-24.CrossRefPubMed
26.
Zurück zum Zitat Ferguson, J.M., et al., The role of duplex and colour Doppler ultrasound in the follow-up evaluation of transjugular intrahepatic portosystemic stent shunt (TIPSS). Br J Radiol, 1995. 68(810): p. 587-9.CrossRefPubMed Ferguson, J.M., et al., The role of duplex and colour Doppler ultrasound in the follow-up evaluation of transjugular intrahepatic portosystemic stent shunt (TIPSS). Br J Radiol, 1995. 68(810): p. 587-9.CrossRefPubMed
27.
Zurück zum Zitat Kanterman, R.Y., et al., Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction. AJR Am J Roentgenol, 1997. 168(2): p. 467-72.CrossRefPubMed Kanterman, R.Y., et al., Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction. AJR Am J Roentgenol, 1997. 168(2): p. 467-72.CrossRefPubMed
28.
Zurück zum Zitat Kimura, M., et al., Efficacy of Doppler ultrasonography for assessment of transjugular intrahepatic portosystemic shunt patency. Cardiovasc Intervent Radiol, 1996. 19(6): p. 397-400.CrossRefPubMed Kimura, M., et al., Efficacy of Doppler ultrasonography for assessment of transjugular intrahepatic portosystemic shunt patency. Cardiovasc Intervent Radiol, 1996. 19(6): p. 397-400.CrossRefPubMed
29.
Zurück zum Zitat Klinger, C., et al., Doppler ultrasound surveillance of TIPS-patency in the era of covered stents–retrospective analysis of a large single-center cohort. Zeitschrift für Gastroenterologie, 2018. 56(09): p. 1053-1062.CrossRefPubMed Klinger, C., et al., Doppler ultrasound surveillance of TIPS-patency in the era of covered stentsretrospective analysis of a large single-center cohort. Zeitschrift für Gastroenterologie, 2018. 56(09): p. 1053-1062.CrossRefPubMed
30.
Zurück zum Zitat Murphy, T.P., et al., Long-term follow-up after TIPS: use of Doppler velocity criteria for detecting elevation of the portosystemic gradient. J Vasc Interv Radiol, 1998. 9(2): p. 275-81.CrossRefPubMed Murphy, T.P., et al., Long-term follow-up after TIPS: use of Doppler velocity criteria for detecting elevation of the portosystemic gradient. J Vasc Interv Radiol, 1998. 9(2): p. 275-81.CrossRefPubMed
31.
Zurück zum Zitat Nicolas, C., et al., Evaluation of Doppler-ultrasonography in the diagnosis of transjugular intrahepatic portosystemic shunt dysfunction: A prospective study. World journal of hepatology, 2017. 9(27): p. 1125.CrossRefPubMedPubMedCentral Nicolas, C., et al., Evaluation of Doppler-ultrasonography in the diagnosis of transjugular intrahepatic portosystemic shunt dysfunction: A prospective study. World journal of hepatology, 2017. 9(27): p. 1125.CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Young, S., et al., Duplex Ultrasound Versus Clinical Surveillance in the Prediction of TIPS Malfunction Placed for Refractory Ascites: Is Ultrasound Surveillance Useful? Cardiovasc Intervent Radiol, 2017. 40(12): p. 1861-1865.CrossRefPubMed Young, S., et al., Duplex Ultrasound Versus Clinical Surveillance in the Prediction of TIPS Malfunction Placed for Refractory Ascites: Is Ultrasound Surveillance Useful? Cardiovasc Intervent Radiol, 2017. 40(12): p. 1861-1865.CrossRefPubMed
33.
Zurück zum Zitat Zizka, J., et al., Value of Doppler sonography in revealing transjugular intrahepatic portosystemic shunt malfunction: a 5-year experience in 216 patients. AJR Am J Roentgenol, 2000. 175(1): p. 141-8.CrossRefPubMed Zizka, J., et al., Value of Doppler sonography in revealing transjugular intrahepatic portosystemic shunt malfunction: a 5-year experience in 216 patients. AJR Am J Roentgenol, 2000. 175(1): p. 141-8.CrossRefPubMed
Metadaten
Titel
Performance of ultrasound for detection of transjugular intrahepatic portosystemic shunt dysfunction: a meta-analysis
verfasst von
Wuttiporn Manatsathit
Hrishikesh Samant
Panadeekarn Panjawatanan
Annie Braseth
Jane Suh
Mohammad Esmadi
Noah Wiedel
Thammasin Ingviya
Publikationsdatum
23.03.2019
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 7/2019
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-019-01981-w

Weitere Artikel der Ausgabe 7/2019

Abdominal Radiology 7/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.