Abstract

To promote rapid bone healing, an adequate stable fixation implant with a percutaneous reduction instrument should be used for Vancouver type B1 or C fractures. The objective of this study was to describe radiographic and clinical outcomes of patients with periprosthetic fracture (PPF) around a stable femoral stem, treated with a distal femoral locking plate alone or with a cerclage cable. A total of 21 patients with PPF amenable to either a reverse distal femoral locking plate (LCP DF®) alone or with a cerclage cable, with a mean age of 75.7 years, were included. In these patients, ten fractures were treated with a reverse LCP DF® alone and were classified as group I, and 11 additionally received a cerclage cable and were classified as group II. Group II had a significantly longer operation time (P = 0.019) than group I and included one patient with nonunion at the final 24-month follow-up visit after the initial fracture reduction. However, this difference in nonunion rate for the two groups is more likely to inappropriate indications than surgical techniques. When comparing the stability of the fractures in both groups, there was no statistically significant difference, which might be attributed to the stable fixed-angle implant.
Literatur
1.
Zurück zum Zitat Lindahl H, Garellick G, Regnér H, Herberts P, Malchau H (2006) Three hundred and twenty-one periprosthetic femoral fractures. J Bone Joint Surg Am 88(6):1215–1222PubMed Lindahl H, Garellick G, Regnér H, Herberts P, Malchau H (2006) Three hundred and twenty-one periprosthetic femoral fractures. J Bone Joint Surg Am 88(6):1215–1222PubMed
2.
Zurück zum Zitat Pellicci P, Tria AJ, Garvin K (2000) Orthopaedic knowledge update (hip and knee reconstruction 2). American Academy of Orthopaedic Surgeons, Rosemont (III) Pellicci P, Tria AJ, Garvin K (2000) Orthopaedic knowledge update (hip and knee reconstruction 2). American Academy of Orthopaedic Surgeons, Rosemont (III)
3.
Zurück zum Zitat Laurer HL, Wutzler S, Possner S, Geiger EV, El Saman A, Marzi I, Frank J (2011) Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty. Arch Orthop Trauma Surg 131(7):983–989CrossRefPubMed Laurer HL, Wutzler S, Possner S, Geiger EV, El Saman A, Marzi I, Frank J (2011) Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty. Arch Orthop Trauma Surg 131(7):983–989CrossRefPubMed
4.
Zurück zum Zitat Brady OH, Garbuz DS, Masri BA, Duncan CP (2000) The reliability of validity of the Vancouver classification of femoral fractures after hip replacement. J Arthroplasty 15(1):59–62CrossRefPubMed Brady OH, Garbuz DS, Masri BA, Duncan CP (2000) The reliability of validity of the Vancouver classification of femoral fractures after hip replacement. J Arthroplasty 15(1):59–62CrossRefPubMed
5.
Zurück zum Zitat Ninan T, Costa ML, Krikler S (2007) Classification of femoral periprosthetic fractures. Injury 38(6):661–668CrossRefPubMed Ninan T, Costa ML, Krikler S (2007) Classification of femoral periprosthetic fractures. Injury 38(6):661–668CrossRefPubMed
6.
Zurück zum Zitat Abhaykumar S, Elliott D (2000) Percutaneous plate fixation for periprosthetic femoral fractures—a preliminary report. Injury 31(8):627–630CrossRefPubMed Abhaykumar S, Elliott D (2000) Percutaneous plate fixation for periprosthetic femoral fractures—a preliminary report. Injury 31(8):627–630CrossRefPubMed
7.
Zurück zum Zitat Tsiridis E, Narvani A, Noorda RJ, Wuisman PI (2003) Mennen plate fixation for the treatment of periprosthetic femoral fractures. J Bone Joint Surg Am 85(9):1851CrossRefPubMed Tsiridis E, Narvani A, Noorda RJ, Wuisman PI (2003) Mennen plate fixation for the treatment of periprosthetic femoral fractures. J Bone Joint Surg Am 85(9):1851CrossRefPubMed
8.
Zurück zum Zitat Haddad FS, Duncan CP, Berry DJ, Lewallen DG, Gross AE, Chandler HP (2002) Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate. J Bone Joint Surg Am 84(6):945–950CrossRefPubMed Haddad FS, Duncan CP, Berry DJ, Lewallen DG, Gross AE, Chandler HP (2002) Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate. J Bone Joint Surg Am 84(6):945–950CrossRefPubMed
9.
Zurück zum Zitat Ricci WM, Bolhofner BR, Loftus T, Cox C, Mitchell S, Borrelli J Jr (2005) Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. J Bone Joint Surg Am 87(10):2240–2245PubMed Ricci WM, Bolhofner BR, Loftus T, Cox C, Mitchell S, Borrelli J Jr (2005) Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. J Bone Joint Surg Am 87(10):2240–2245PubMed
10.
Zurück zum Zitat Kolb W, Guhlmann H, Friedel R, Nestmann H (2003) Fixation of periprosthetic femur fractures with the less invasive stabilization system (LISS)—a new minimally invasive treatment with locked fixed-angle screws. Zent Chir 128(1):53–59CrossRef Kolb W, Guhlmann H, Friedel R, Nestmann H (2003) Fixation of periprosthetic femur fractures with the less invasive stabilization system (LISS)—a new minimally invasive treatment with locked fixed-angle screws. Zent Chir 128(1):53–59CrossRef
11.
Zurück zum Zitat Fulkerson E, Tejwani N, Stuchin S, Egol K (2007) Management of periprosthetic femur fractures with a first generation locking plate. Injury 38(8):965–972CrossRefPubMed Fulkerson E, Tejwani N, Stuchin S, Egol K (2007) Management of periprosthetic femur fractures with a first generation locking plate. Injury 38(8):965–972CrossRefPubMed
12.
Zurück zum Zitat Chakravarthy J, Bansal R, Cooper J (2007) Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. Injury 38(6):725–733CrossRefPubMed Chakravarthy J, Bansal R, Cooper J (2007) Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. Injury 38(6):725–733CrossRefPubMed
13.
Zurück zum Zitat Wood GC, Naudie DR, McAuley J, McCalden RW (2011) Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants. J Arthroplasty 26(6):886–892CrossRefPubMed Wood GC, Naudie DR, McAuley J, McCalden RW (2011) Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants. J Arthroplasty 26(6):886–892CrossRefPubMed
14.
Zurück zum Zitat Shi HY, Chang JK, Wong CY, Wang JW, Tu YK, Chiu HC, Lee KT (2010) Responsiveness and minimal important differences after revision total hip arthroplasty. BMC Musculoskelet Disord 11:261CrossRefPubMedPubMedCentral Shi HY, Chang JK, Wong CY, Wang JW, Tu YK, Chiu HC, Lee KT (2010) Responsiveness and minimal important differences after revision total hip arthroplasty. BMC Musculoskelet Disord 11:261CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Tsiridis E, Haddad FS, Gie GA (2003) Dall-Miles plates for periprosthetic femoral fractures: a critical review of 16 cases. Injury 34(2):107–110CrossRefPubMed Tsiridis E, Haddad FS, Gie GA (2003) Dall-Miles plates for periprosthetic femoral fractures: a critical review of 16 cases. Injury 34(2):107–110CrossRefPubMed
16.
Zurück zum Zitat Venu K, Koka R, Garikipati R, Shenava Y, Madhu T (2001) Dall-Miles cable and plate fixation for the treatment of peri-prosthetic femoral fractures-analysis of results in 13 cases. Injury 32(5):395–400CrossRefPubMed Venu K, Koka R, Garikipati R, Shenava Y, Madhu T (2001) Dall-Miles cable and plate fixation for the treatment of peri-prosthetic femoral fractures-analysis of results in 13 cases. Injury 32(5):395–400CrossRefPubMed
17.
Zurück zum Zitat Springer BD, Berry DJ, Lewallen DG (2003) Treatment of periprosthetic femoral fractures following total hip arthroplasty with femoral component revision. J Bone Joint Surg Am 85(11):2156–2162CrossRefPubMed Springer BD, Berry DJ, Lewallen DG (2003) Treatment of periprosthetic femoral fractures following total hip arthroplasty with femoral component revision. J Bone Joint Surg Am 85(11):2156–2162CrossRefPubMed
18.
Zurück zum Zitat Buttaro M, Farfalli G, Núñez MP, Comba F, Piccaluga F (2007) Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am 89(9):1964–1969PubMed Buttaro M, Farfalli G, Núñez MP, Comba F, Piccaluga F (2007) Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am 89(9):1964–1969PubMed
19.
Zurück zum Zitat Bryant GK, Morshed S, Agel J, Henley MB, Barei DP, Taitsman LA, Nork SE (2009) Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury 40(11):1180–1186CrossRefPubMed Bryant GK, Morshed S, Agel J, Henley MB, Barei DP, Taitsman LA, Nork SE (2009) Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury 40(11):1180–1186CrossRefPubMed
20.
Zurück zum Zitat O’Toole RV, Gobezie R, Hwang R, Chandler AR, Smith RM, Estok DM, Vrahas MS (2006) Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty. Clin Orthop Relat Res 450:203–210CrossRefPubMed O’Toole RV, Gobezie R, Hwang R, Chandler AR, Smith RM, Estok DM, Vrahas MS (2006) Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty. Clin Orthop Relat Res 450:203–210CrossRefPubMed
21.
Zurück zum Zitat Xue H, Tu Y, Cai M, Yang A (2011) Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures: preliminary results at average 30-month follow-up. J Arthroplasty 26(3):467–471CrossRefPubMed Xue H, Tu Y, Cai M, Yang A (2011) Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures: preliminary results at average 30-month follow-up. J Arthroplasty 26(3):467–471CrossRefPubMed
22.
Zurück zum Zitat Erhardt J, Grob K, Roderer G, Hoffmann A, Forster T, Kuster M (2008) Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant. Arch Orthop Trauma Surg 128(4):409–416CrossRefPubMed Erhardt J, Grob K, Roderer G, Hoffmann A, Forster T, Kuster M (2008) Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant. Arch Orthop Trauma Surg 128(4):409–416CrossRefPubMed
23.
Zurück zum Zitat Ebraheim NA, Gomez C, Ramineni SK, Liu J (2009) Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate. J Trauma 66(4):1152–1157CrossRefPubMed Ebraheim NA, Gomez C, Ramineni SK, Liu J (2009) Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate. J Trauma 66(4):1152–1157CrossRefPubMed
24.
Zurück zum Zitat Lenz M, Perren SM, Gueorguiev B, Richards RG, Hofmann GO, Fernandez dell’Oca A, Höntzsch D, Windolf M (2014) A biomechanical study on proximal plate fixation techniques in periprosthetic femur fractures. Injury 45:S71–S75CrossRefPubMed Lenz M, Perren SM, Gueorguiev B, Richards RG, Hofmann GO, Fernandez dell’Oca A, Höntzsch D, Windolf M (2014) A biomechanical study on proximal plate fixation techniques in periprosthetic femur fractures. Injury 45:S71–S75CrossRefPubMed
25.
Zurück zum Zitat Kampshoff J, Stoffel KK, Yates PJ, Erhardt JB, Kuster MS (2010) The treatment of periprosthetic fractures with locking plates: effect of drill and screw type on cement mantles: a biomechanical analysis. Arch Orthop Trauma Surg 130(5):627–632CrossRefPubMed Kampshoff J, Stoffel KK, Yates PJ, Erhardt JB, Kuster MS (2010) The treatment of periprosthetic fractures with locking plates: effect of drill and screw type on cement mantles: a biomechanical analysis. Arch Orthop Trauma Surg 130(5):627–632CrossRefPubMed
Metadaten
Titel
Periprosthetic fracture around a stable femoral stem treated with locking plate osteosynthesis: distal femoral locking plate alone versus with cerclage cable
verfasst von
Young-Soo Shin
Seung-Beom Han
Publikationsdatum
16.01.2017
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 5/2017
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-017-1900-5

Weitere Artikel der Ausgabe 5/2017

European Journal of Orthopaedic Surgery & Traumatology 5/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.