Skip to main content
Erschienen in: International Orthopaedics 2/2017

10.08.2016 | Original Paper

Persistent non-union of the humeral shaft treated by plating and autologous bone grafting

verfasst von: Tristan Pollon, Nicolas Reina, Stéphanie Delclaux, Paul Bonnevialle, Pierre Mansat, Nicolas Bonnevialle

Erschienen in: International Orthopaedics | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Surgical treatment of persistent non-union of the humeral shaft is a complex situation because of the risk of failure and surgery-related complications. The primary objective of this study was to evaluate clinical and radiological results of a continuous series of persistent non-union treated with plating and bone grafting. The secondary objective was to expose factors contributing to the failure of prior bone union attempts.

Material and Methods

Sixteen patients (average age of 52 years) were treated for persistent non-union of the humeral shaft in our department; six of these patients had predisposing comorbidities or addictions. The persistent non-union was treated by plating with autologous bone graft from the iliac crest in a single-stage procedure in 12 cases and a two-stage procedure in three cases; one case was treated with plating and vascularized fibula graft.

Results

At a minimum follow-up of 12 months (average 78 months), four (25 %) failed to heal. The 12 other patients had bone union after an average of eight months. The average QuickDASH score was 48 points (18–72). A retrospective analysis of the prior attempts to treat the non-union revealed three cases of unstable fixation, four cases with no osteogenic supply and seven cases of positive microbiological cultures at the non-union site.

Conclusion

Plating and autologous bone grafting resulted in union in only 75 % of persistent non-union of the humeral shaft. The persistent nature of the humeral shaft non-union could be attributed to deviating from validated rules for surgical treatment and/or the presence of a surgical site infection.
Literatur
3.
Zurück zum Zitat Bernard de Dompsure R, Peter R, Hoffmeyer P (2010) Uninfected nonunion of the humeral diaphysis: review of 21 patients treated with shingling, compression plate, and autologous bone graft. Orthop Traumatol Surg Res 96:139–146. doi:10.1016/j.rcot.2010.02.003 CrossRefPubMed Bernard de Dompsure R, Peter R, Hoffmeyer P (2010) Uninfected nonunion of the humeral diaphysis: review of 21 patients treated with shingling, compression plate, and autologous bone graft. Orthop Traumatol Surg Res 96:139–146. doi:10.​1016/​j.​rcot.​2010.​02.​003 CrossRefPubMed
4.
Zurück zum Zitat Barquet A, Fernandez A, Luvizio J, Masliah R (1989) A combined therapeutic protocol for aseptic nonunion of the humeral shaft: a report of 25 cases. J Trauma 29:95–98CrossRefPubMed Barquet A, Fernandez A, Luvizio J, Masliah R (1989) A combined therapeutic protocol for aseptic nonunion of the humeral shaft: a report of 25 cases. J Trauma 29:95–98CrossRefPubMed
5.
Zurück zum Zitat Borus TA, Yian EH, Karunakar MA (2005) A case series and review of salvage surgery for refractory humeral shaft nonunion following two or more prior surgical procedures. Iowa Orthop J 25:194–199PubMedPubMedCentral Borus TA, Yian EH, Karunakar MA (2005) A case series and review of salvage surgery for refractory humeral shaft nonunion following two or more prior surgical procedures. Iowa Orthop J 25:194–199PubMedPubMedCentral
7.
Zurück zum Zitat Dujardin FH, Mazirt N, Tobenas AC, Duparc F, Thomine JM (2000) Failure of locked centro-medullary nailing in pseudarthrosis of the humeral diaphysis. Rev Chir Orthop Reparatrice Appar Mot 86:773–80PubMed Dujardin FH, Mazirt N, Tobenas AC, Duparc F, Thomine JM (2000) Failure of locked centro-medullary nailing in pseudarthrosis of the humeral diaphysis. Rev Chir Orthop Reparatrice Appar Mot 86:773–80PubMed
8.
Zurück zum Zitat Gross JB, Diligent J, Bensoussan D, Galois L, Stoltz JF, Mainard D (2015) Percutaneous autologous bone marrow injection for treatment of delayed and non-union of long bone: a retrospective study of 45 cases. Biomed Mater Eng 25:187–97. doi:10.3233/BME-141235 PubMed Gross JB, Diligent J, Bensoussan D, Galois L, Stoltz JF, Mainard D (2015) Percutaneous autologous bone marrow injection for treatment of delayed and non-union of long bone: a retrospective study of 45 cases. Biomed Mater Eng 25:187–97. doi:10.​3233/​BME-141235 PubMed
9.
Zurück zum Zitat Healy WL, White GM, Mick CA, Brooker AF Jr, Weiland AJ (1987) Nonunion of the humeral shaft. Clin Orthop Relat Res 219:206–213 Healy WL, White GM, Mick CA, Brooker AF Jr, Weiland AJ (1987) Nonunion of the humeral shaft. Clin Orthop Relat Res 219:206–213
10.
Zurück zum Zitat Hierholzer C, Sama D, Toro JB, Peterson M, Helfet DL (2006) Plate fixation of ununited humeral shaft fractures: effect of type of bone graft on healing. J Bone Joint Surg Am 88:1442–1447. doi:10.2106/JBJS.E.00332 PubMed Hierholzer C, Sama D, Toro JB, Peterson M, Helfet DL (2006) Plate fixation of ununited humeral shaft fractures: effect of type of bone graft on healing. J Bone Joint Surg Am 88:1442–1447. doi:10.​2106/​JBJS.​E.​00332 PubMed
11.
Zurück zum Zitat Jupiter JB, von Deck M (1998) Ununited humeral diaphysis. J Shoulder Elbow Surg 1998 7:644–53CrossRef Jupiter JB, von Deck M (1998) Ununited humeral diaphysis. J Shoulder Elbow Surg 1998 7:644–53CrossRef
16.
Zurück zum Zitat Lang NW, Ostermann RC, Arthold C, Joestl J, Platzer P (2016) Retrospective case series with one year follow-up after radial nerve palsy associated with humeral fractures. Int Orthop (In Press) Lang NW, Ostermann RC, Arthold C, Joestl J, Platzer P (2016) Retrospective case series with one year follow-up after radial nerve palsy associated with humeral fractures. Int Orthop (In Press)
17.
19.
Zurück zum Zitat McKee MD, Miranda MA, Riemer BL, Blasier RB, Redmond BJ, Sims SH, Waddell JP, Jupiter JB (1996) Management of humeral nonunion after the failure of locking intramedullary nails. J Orthop Trauma 10:492–499CrossRefPubMed McKee MD, Miranda MA, Riemer BL, Blasier RB, Redmond BJ, Sims SH, Waddell JP, Jupiter JB (1996) Management of humeral nonunion after the failure of locking intramedullary nails. J Orthop Trauma 10:492–499CrossRefPubMed
20.
Zurück zum Zitat Muller ME, Thomas RJ (1979) Treatment of non-union in fractures of long bones. Clin Orthop Relat Res 138:141–153 Muller ME, Thomas RJ (1979) Treatment of non-union in fractures of long bones. Clin Orthop Relat Res 138:141–153
21.
Zurück zum Zitat Marti RK, Verheyen CC, Besselaar PP (2002) Humeral shaft nonunion: evaluation of uniform surgical repair in fifty-one patients. J Orthop Trauma 16:108–115CrossRefPubMed Marti RK, Verheyen CC, Besselaar PP (2002) Humeral shaft nonunion: evaluation of uniform surgical repair in fifty-one patients. J Orthop Trauma 16:108–115CrossRefPubMed
23.
Zurück zum Zitat Matheson LN, Melhorn JM, Mayer TG, Theodore BR, Gatchel RJ (2006) Reliability of a visual analog version of the Quick DASH. J Bone Joint Surg Am 88:1782–1787. doi:10.2106/JBJS.F.00406 PubMed Matheson LN, Melhorn JM, Mayer TG, Theodore BR, Gatchel RJ (2006) Reliability of a visual analog version of the Quick DASH. J Bone Joint Surg Am 88:1782–1787. doi:10.​2106/​JBJS.​F.​00406 PubMed
24.
25.
Zurück zum Zitat Neel M (2004) Successful treatment of a persistent humeral shaft nonunion using open reduction internal fixation, electrical stimulation, and AlloMatrix Custom Bone Putty. Orthopedics 27:109–111 Neel M (2004) Successful treatment of a persistent humeral shaft nonunion using open reduction internal fixation, electrical stimulation, and AlloMatrix Custom Bone Putty. Orthopedics 27:109–111
26.
Zurück zum Zitat Otsuka NY, McKee MD, Liew A, Richards RR, Waddell JP (1998) The effect of comorbidity and duration of nonunion on outcome after surgical treatment for nonunion of the humerus. J Shoulder Elb Surg 7:127–133CrossRef Otsuka NY, McKee MD, Liew A, Richards RR, Waddell JP (1998) The effect of comorbidity and duration of nonunion on outcome after surgical treatment for nonunion of the humerus. J Shoulder Elb Surg 7:127–133CrossRef
28.
Zurück zum Zitat Pietu G, Raynaud G, Letenneur J (1994) Treatment of delayed and nonunions of the humeral shaft using the Seidel locking nail: a preliminary report of five cases. J Orthop Trauma 8:240–244CrossRefPubMed Pietu G, Raynaud G, Letenneur J (1994) Treatment of delayed and nonunions of the humeral shaft using the Seidel locking nail: a preliminary report of five cases. J Orthop Trauma 8:240–244CrossRefPubMed
29.
Zurück zum Zitat Ring D, Perey BH, Jupiter JB (1999) The functional outcome of operative treatment of ununited fractures of the humeral diaphysis in older patients. J Bone Joint Surg Am 81:177–190CrossRefPubMed Ring D, Perey BH, Jupiter JB (1999) The functional outcome of operative treatment of ununited fractures of the humeral diaphysis in older patients. J Bone Joint Surg Am 81:177–190CrossRefPubMed
30.
Zurück zum Zitat Ring D, Kloen P, Kadzielski J, Helfet D, Jupiter JB (2004) Locking compression plates for osteoporotic nonunions of the diaphyseal humerus. Clin Orthop Relat Res 425:50–54CrossRef Ring D, Kloen P, Kadzielski J, Helfet D, Jupiter JB (2004) Locking compression plates for osteoporotic nonunions of the diaphyseal humerus. Clin Orthop Relat Res 425:50–54CrossRef
31.
Zurück zum Zitat Ring D, Jupiter JB, Quintero J, Sanders RA, Marti RK (2000) Atrophic ununited diaphyseal fractures of the humerus with a bony defect: treatment by wave-plate osteosynthesis. J Bone Joint Surg (Br) 82:867–871CrossRef Ring D, Jupiter JB, Quintero J, Sanders RA, Marti RK (2000) Atrophic ununited diaphyseal fractures of the humerus with a bony defect: treatment by wave-plate osteosynthesis. J Bone Joint Surg (Br) 82:867–871CrossRef
32.
Zurück zum Zitat Rosen H (1990) The treatment of nonunions and pseudarthrosis of the humeral shaft. Orthop Clin N Am 21:725–742 Rosen H (1990) The treatment of nonunions and pseudarthrosis of the humeral shaft. Orthop Clin N Am 21:725–742
33.
Zurück zum Zitat Segonds JM, Alnot JY, Masmejean E (2003) Aseptic non-union of humeral shaft fractures treated by plating and bone grafting. Rev Chir Orthop Reparatrice Appar Mot 89:107–14PubMed Segonds JM, Alnot JY, Masmejean E (2003) Aseptic non-union of humeral shaft fractures treated by plating and bone grafting. Rev Chir Orthop Reparatrice Appar Mot 89:107–14PubMed
34.
Zurück zum Zitat Singh AK, Arun GR, Narsaria N, Srivastava A (2009) Treatment of non-union of humerus diaphyseal fractures: a prospective study comparing interlocking nail and locking compression plate. J Trauma 67:1393–1396. doi:10.1007/s00402-014-1973-0 CrossRef Singh AK, Arun GR, Narsaria N, Srivastava A (2009) Treatment of non-union of humerus diaphyseal fractures: a prospective study comparing interlocking nail and locking compression plate. J Trauma 67:1393–1396. doi:10.​1007/​s00402-014-1973-0 CrossRef
35.
Zurück zum Zitat Thompson AG, Batten RL (1977) The application of rigid internal fixation to the treatment of non-union and delayed union using the AO technique. Injury 8:188–9824CrossRefPubMed Thompson AG, Batten RL (1977) The application of rigid internal fixation to the treatment of non-union and delayed union using the AO technique. Injury 8:188–9824CrossRefPubMed
Metadaten
Titel
Persistent non-union of the humeral shaft treated by plating and autologous bone grafting
verfasst von
Tristan Pollon
Nicolas Reina
Stéphanie Delclaux
Paul Bonnevialle
Pierre Mansat
Nicolas Bonnevialle
Publikationsdatum
10.08.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 2/2017
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3267-3

Weitere Artikel der Ausgabe 2/2017

International Orthopaedics 2/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.