Skip to main content
Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging 13/2019

29.08.2019 | Original Article

PET image denoising using unsupervised deep learning

verfasst von: Jianan Cui, Kuang Gong, Ning Guo, Chenxi Wu, Xiaxia Meng, Kyungsang Kim, Kun Zheng, Zhifang Wu, Liping Fu, Baixuan Xu, Zhaohui Zhu, Jiahe Tian, Huafeng Liu, Quanzheng Li

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 13/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Image quality of positron emission tomography (PET) is limited by various physical degradation factors. Our study aims to perform PET image denoising by utilizing prior information from the same patient. The proposed method is based on unsupervised deep learning, where no training pairs are needed.

Methods

In this method, the prior high-quality image from the patient was employed as the network input and the noisy PET image itself was treated as the training label. Constrained by the network structure and the prior image input, the network was trained to learn the intrinsic structure information from the noisy image and output a restored PET image. To validate the performance of the proposed method, a computer simulation study based on the BrainWeb phantom was first performed. A 68Ga-PRGD2 PET/CT dataset containing 10 patients and a 18F-FDG PET/MR dataset containing 30 patients were later on used for clinical data evaluation. The Gaussian, non-local mean (NLM) using CT/MR image as priors, BM4D, and Deep Decoder methods were included as reference methods. The contrast-to-noise ratio (CNR) improvements were used to rank different methods based on Wilcoxon signed-rank test.

Results

For the simulation study, contrast recovery coefficient (CRC) vs. standard deviation (STD) curves showed that the proposed method achieved the best performance regarding the bias-variance tradeoff. For the clinical PET/CT dataset, the proposed method achieved the highest CNR improvement ratio (53.35% ± 21.78%), compared with the Gaussian (12.64% ± 6.15%, P = 0.002), NLM guided by CT (24.35% ± 16.30%, P = 0.002), BM4D (38.31% ± 20.26%, P = 0.002), and Deep Decoder (41.67% ± 22.28%, P = 0.002) methods. For the clinical PET/MR dataset, the CNR improvement ratio of the proposed method achieved 46.80% ± 25.23%, higher than the Gaussian (18.16% ± 10.02%, P < 0.0001), NLM guided by MR (25.36% ± 19.48%, P < 0.0001), BM4D (37.02% ± 21.38%, P < 0.0001), and Deep Decoder (30.03% ± 20.64%, P < 0.0001) methods. Restored images for all the datasets demonstrate that the proposed method can effectively smooth out the noise while recovering image details.

Conclusion

The proposed unsupervised deep learning framework provides excellent image restoration effects, outperforming the Gaussian, NLM methods, BM4D, and Deep Decoder methods.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT scanner for clinical oncology. J Nucl Med. 2000;41:1369–79.PubMed Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT scanner for clinical oncology. J Nucl Med. 2000;41:1369–79.PubMed
3.
Zurück zum Zitat Schwaiger M, Ziegler S, Nekolla SG. PET/CT: challenge for nuclear cardiology. J Nucl Med. 2005;46:1664–78.PubMed Schwaiger M, Ziegler S, Nekolla SG. PET/CT: challenge for nuclear cardiology. J Nucl Med. 2005;46:1664–78.PubMed
17.
Zurück zum Zitat He K, Sun J, Tang X. Guided image filtering. IEEE Trans Pattern Anal Mach Intell. 2013;35:1397–409.CrossRefPubMed He K, Sun J, Tang X. Guided image filtering. IEEE Trans Pattern Anal Mach Intell. 2013;35:1397–409.CrossRefPubMed
24.
Zurück zum Zitat Wu D, Kim K, Fakhri G El, Li Q. A cascaded convolutional neural network for x-ray low-dose CT image denoising 2017. Wu D, Kim K, Fakhri G El, Li Q. A cascaded convolutional neural network for x-ray low-dose CT image denoising 2017.
31.
34.
Zurück zum Zitat Nesterov Y. A method for unconstrained convex minimization problem with the rate of convergence o(1/k^2). Dokl AN USSR. 1983;269:543–7. Nesterov Y. A method for unconstrained convex minimization problem with the rate of convergence o(1/k^2). Dokl AN USSR. 1983;269:543–7.
35.
Zurück zum Zitat Cocosco CA, Kollokian V, Kwan RK-S, Pike GB, Evans AC. Brainweb: online interface to a 3D MRI simulated brain database. Citeseer: Neuroimage; 1997. Cocosco CA, Kollokian V, Kwan RK-S, Pike GB, Evans AC. Brainweb: online interface to a 3D MRI simulated brain database. Citeseer: Neuroimage; 1997.
Metadaten
Titel
PET image denoising using unsupervised deep learning
verfasst von
Jianan Cui
Kuang Gong
Ning Guo
Chenxi Wu
Xiaxia Meng
Kyungsang Kim
Kun Zheng
Zhifang Wu
Liping Fu
Baixuan Xu
Zhaohui Zhu
Jiahe Tian
Huafeng Liu
Quanzheng Li
Publikationsdatum
29.08.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 13/2019
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-019-04468-4

Weitere Artikel der Ausgabe 13/2019

European Journal of Nuclear Medicine and Molecular Imaging 13/2019 Zur Ausgabe