Abstract

The accuracy of the arterial pressure-based cardiac output FloTrac-Vigileo system remains unacceptably low during haemodynamic instability. Data show that the measurement of cardiac output (CO) is strongly influenced by changes in factors that affect arterial blood pressure (ABP) - for example, vascular tone and compliance and the arterial site - independently of true changes in CO. Although in theory the autocalibration algorithm of FloTrac-Vigileo should adjust for those changes, the model undercompensates (or overcompensates) for prominent increases (or decreases) in vascular tone and compliance, making the system largely dependent on changes in ABP. These limitations make FloTrac-Vigileo accurate in stable haemodynamic conditions only, and until more robust algorithms and further validation studies become available, we should be aware that during haemodynamic instability or in extreme conditions of vasodilation or vasoconstriction, the measured CO may diverge from an independent bolus indicator dilution measurement, particularly if a peripheral artery is used. In these conditions, we advocate the use of transpulmonary indicator dilution via a femoral artery.
Literatur
1.
Zurück zum Zitat Eleftheriadis S, Galatoudis Z, Didilis V, Bougioukas I, Schon J, Heinze H, Berger KU, Heringlake M: Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo(R)-derived cardiac output measurements: a prospective comparison study. Crit Care. 2009, 13: R179-10.1186/cc8161.PubMedCentralCrossRefPubMed Eleftheriadis S, Galatoudis Z, Didilis V, Bougioukas I, Schon J, Heinze H, Berger KU, Heringlake M: Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo(R)-derived cardiac output measurements: a prospective comparison study. Crit Care. 2009, 13: R179-10.1186/cc8161.PubMedCentralCrossRefPubMed
2.
Zurück zum Zitat Biancofiore G, Critchley LA, Lee A, Bindi L, Bisà M, Esposito M, Meacci L, Mozzo R, DeSimone P, Urbani L, Filipponi F: Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth. 2009, 102: 47-54. 10.1093/bja/aen343.CrossRefPubMed Biancofiore G, Critchley LA, Lee A, Bindi L, Bisà M, Esposito M, Meacci L, Mozzo R, DeSimone P, Urbani L, Filipponi F: Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth. 2009, 102: 47-54. 10.1093/bja/aen343.CrossRefPubMed
3.
Zurück zum Zitat Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, Sztark F: Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg. 2008, 106: 1480-1486. 10.1213/ane.0b013e318168b309. table of contentsCrossRefPubMed Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, Sztark F: Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg. 2008, 106: 1480-1486. 10.1213/ane.0b013e318168b309. table of contentsCrossRefPubMed
4.
Zurück zum Zitat Sakka SG, Kozieras J, Thuemer O, van Hout N: Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth. 2007, 99: 337-342. 10.1093/bja/aem177.CrossRefPubMed Sakka SG, Kozieras J, Thuemer O, van Hout N: Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth. 2007, 99: 337-342. 10.1093/bja/aem177.CrossRefPubMed
5.
Zurück zum Zitat Compton FD, Zukunft B, Hoffmann C, Zidek W, Schaefer JH: Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients. Br J Anaesth. 2008, 100: 451-456. 10.1093/bja/aem409.CrossRefPubMed Compton FD, Zukunft B, Hoffmann C, Zidek W, Schaefer JH: Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients. Br J Anaesth. 2008, 100: 451-456. 10.1093/bja/aem409.CrossRefPubMed
6.
Zurück zum Zitat Mayer J, Boldt J, Schollhorn T, Rohm KD, Mengistu AM, Suttner S: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth. 2007, 98: 176-182. 10.1093/bja/ael341.CrossRefPubMed Mayer J, Boldt J, Schollhorn T, Rohm KD, Mengistu AM, Suttner S: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth. 2007, 98: 176-182. 10.1093/bja/ael341.CrossRefPubMed
7.
Zurück zum Zitat Mayer J, Boldt J, Poland R, Peterson A, Manecke GR: Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis. J Cardiothorac Vasc Anesth. 2009, 23: 401-406. 10.1053/j.jvca.2009.03.003.CrossRefPubMed Mayer J, Boldt J, Poland R, Peterson A, Manecke GR: Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis. J Cardiothorac Vasc Anesth. 2009, 23: 401-406. 10.1053/j.jvca.2009.03.003.CrossRefPubMed
8.
Zurück zum Zitat Chauhan S, Saxena N, Mehrotra S, Rao BH, Sahu M: Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass. J Cardiothorac Vasc Anesth. 2000, 14: 274-276. 10.1016/S1053-0770(00)90124-1.CrossRefPubMed Chauhan S, Saxena N, Mehrotra S, Rao BH, Sahu M: Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass. J Cardiothorac Vasc Anesth. 2000, 14: 274-276. 10.1016/S1053-0770(00)90124-1.CrossRefPubMed
9.
Zurück zum Zitat Manecke GR, Parimucha M, Stratmann G, Wilson WC, Roth DM, Auger WR, Kerr KM, Jamieson SW, Kapelanski DP, Mitchell MM: Deep hypothermic circulatory arrest and the femoral-to-radial arterial pressure gradient. J Cardiothorac Vasc Anesth. 2004, 18: 175-179. 10.1053/j.jvca.2004.01.023.CrossRefPubMed Manecke GR, Parimucha M, Stratmann G, Wilson WC, Roth DM, Auger WR, Kerr KM, Jamieson SW, Kapelanski DP, Mitchell MM: Deep hypothermic circulatory arrest and the femoral-to-radial arterial pressure gradient. J Cardiothorac Vasc Anesth. 2004, 18: 175-179. 10.1053/j.jvca.2004.01.023.CrossRefPubMed
10.
Zurück zum Zitat Rivers EP, Lozon J, Enriquez E, Havstad SV, Martin GB, Lewandowski CA, Goetting MG, Rosenberg JA, Paradis NA, Nowak RM: Simultaneous radial, femoral, and aortic arterial pressures during human cardiopulmonary resuscitation. Crit Care Med. 1993, 21: 878-883. 10.1097/00003246-199306000-00016.CrossRefPubMed Rivers EP, Lozon J, Enriquez E, Havstad SV, Martin GB, Lewandowski CA, Goetting MG, Rosenberg JA, Paradis NA, Nowak RM: Simultaneous radial, femoral, and aortic arterial pressures during human cardiopulmonary resuscitation. Crit Care Med. 1993, 21: 878-883. 10.1097/00003246-199306000-00016.CrossRefPubMed
11.
Zurück zum Zitat Dorman T, Breslow MJ, Lipsett PA, Rosenberg JM, Balser JR, Almog Y, Rosenfeld BA: Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med. 1998, 26: 1646-1649. 10.1097/00003246-199810000-00014.CrossRefPubMed Dorman T, Breslow MJ, Lipsett PA, Rosenberg JM, Balser JR, Almog Y, Rosenfeld BA: Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med. 1998, 26: 1646-1649. 10.1097/00003246-199810000-00014.CrossRefPubMed
12.
Zurück zum Zitat Arnal D, Garutti I, Perez-Pena J, Olmedilla L, Tzenkov IG: Radial to femoral arterial blood pressure differences during liver transplantation. Anaesthesia. 2005, 60: 766-771. 10.1111/j.1365-2044.2005.04257.x.CrossRefPubMed Arnal D, Garutti I, Perez-Pena J, Olmedilla L, Tzenkov IG: Radial to femoral arterial blood pressure differences during liver transplantation. Anaesthesia. 2005, 60: 766-771. 10.1111/j.1365-2044.2005.04257.x.CrossRefPubMed
13.
Zurück zum Zitat Nichols WW, O'Rourke MF: McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles. 2005, London: Hodder Arnold, 5 Nichols WW, O'Rourke MF: McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles. 2005, London: Hodder Arnold, 5
14.
Zurück zum Zitat Hofer CK, Button D, Weibel L, Genoni M, Zollinger A: Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients. J Cardiothorac Vasc Anesth. 2009. Hofer CK, Button D, Weibel L, Genoni M, Zollinger A: Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients. J Cardiothorac Vasc Anesth. 2009.
15.
Zurück zum Zitat Schramm S, Albrecht E, Frascarolo P, Chassot PG, Spahn DR: Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary catheter thermodilution measurements?. J Cardiothorac Vasc Anesth. 2009. Schramm S, Albrecht E, Frascarolo P, Chassot PG, Spahn DR: Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary catheter thermodilution measurements?. J Cardiothorac Vasc Anesth. 2009.
Metadaten
Titel
Pitfalls in haemodynamic monitoring based on the arterial pressure waveform
verfasst von
Luigi Camporota
Richard Beale
Publikationsdatum
01.04.2010
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 2/2010
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc8845

Weitere Artikel der Ausgabe 2/2010

Critical Care 2/2010 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.