Skip to main content
Erschienen in: Rechtsmedizin 4/2022

Open Access 19.10.2021 | Original reports

Post-mortem computed tomography is a useful tool for determining the pulmonary ventilation status in newborns

verfasst von: Florian T. Fischer, Michael Schwerer, Stefanie Lochner, Daniel Maxien, Fabian Mück, Laura Bechstein, Stefan Wirth, Jochen Grimm

Erschienen in: Rechtsmedizin | Ausgabe 4/2022

Abstract

Introduction

Lung ventilation is a standard sign of life in newborns. Post-mortem computed tomography (PMCT) is highly sensitive to the presence of gas in the body including the lungs. Current standard examinations to determine the pulmonary ventilation status in newborns are the flotation test and histology. The purpose of this study was to compare the accuracy of PMCT with the flotation test for determining the lung ventilation status with histological control as reference standard. A cut-off value as CT number in Hounsfield Units (HU) determining lung ventilation of newborns in PMCT should be established.

Methods

A total of 38 infant lungs were examined of which 21 lungs were from infants deceased shortly after live birth (control group) and 17 lungs belonged to infants where live birth was in question (study group). All lungs were examined using PMCT, flotation test, and histological examination.

Results

The control group showed an overall mean attenuation ± standard deviation of −219 HU ± 135; the study group of 45 ± 15 HU in histologically nonventilated lungs versus −192 ± 207 HU; (p < 0.001) in ventilated lungs. The best cut-off value for optimal discrimination of ventilated and nonventilated lungs in newborns was −35 mean HU.

Conclusion

PMCT is equally well suited to determine lung ventilation as the flotation test. It provides additional information regarding pulmonary infiltration, degree of putrefaction, or signs of trauma (fractures, pneumothorax). Histology remains mandatory in ambiguous cases.
Hinweise
Scan QR code & read article online
Key points
  • Post-mortem computed tomography (PMCT) is equally well suited to determine lung ventilation as the flotation test. The best cut-off value for optimal discrimination of ventilated and nonventilated lungs in newborns was −35 mean HU.
  • Histology remains mandatory in ambiguous cases.

Introduction

Post-mortem computed tomography (PMCT) has been proven to be a useful tool for detecting gas and its distribution patterns [1, 2]. It seems likely that the classical task of assessing the presence of air in the lungs of newborns by flotation tests [38] as a sign of life should be diagnosable by PMCT, because PMCT enables measuring Hounsfield units (HU) as a rough correlate of physical density, the same factor as examined with the flotation test. In recent studies, investigations including histology, macroscopic morphology and PMCT have been promoted. Few have been done so far but to our knowledge the number of cases examined in this manner and reported is still low [9, 10]. Thus, it seemed necessary to establish further data suitable for statistical evaluation concerning PMCT in newborns, especially regarding the question of pulmonary ventilation. If suitable for this task, PMCT would enable a quick and efficient diagnosis of lung ventilation.
The purpose of this study was to determine if PMCT delivers at least comparably reliable results as the established lung flotation test and determine its correlation with histology.

Material and methods

Study design

For this retrospective study we defined a control group (group 2) to evaluate a “normal” range of HU. The HU in the study group (group 1 with ventilated (1a) and nonventilated lungs (1b)) was compared with histology and the normal range of group 2.

Study population

The study population included all neonatal and infant cadavers examined at the Institute of Forensic Medicine during the period from June 2008 to February 2012.
The study group (group 1) comprised neonates determined or presumed dead within 24 h after birth with unclear lung ventilation status and unclear cause of death. After histological work-up group 1 was subdivided into a group 1a (nonventilated) and group 1b (ventilated).
The control group (group 2) included all infants examined during the study period who had lived beyond the immediate neonatal period (> 24 h) but died during the first 4 months post-partum. The control group was used to define a “physiological” range of HU in pediatric post-mortem CT (pedPMCT).
Cases with proven pulmonary pathology (n = 2, one case with pneumonia and one case with pneumothorax) were excluded from this control group (group 2) to make sure only physiological findings were used for the examination and analysis.

CT image acquisition

The CT scans were performed on 64 row multidetector CT, a GE Discovery HD 750 (GE Healthcare GmbH, Solingen, Germany) or a Philips Brilliance 64 (Philips GmbH, Hamburg, Germany). Imaging parameters were 120 kV and modulated tube current in helical mode with slice collimation of 0.625 mm, with slice thickness of 2.5 mm after reconstruction. Images were reviewed on certified workstations, density measurements were done on the same equipment.

CT image analysis

A board-certified radiologist and a board-certified forensic pathologist both with 5 or more years experience in post-mortem imaging analyzed all thoracic images and placed all regions of interest (ROIs) in consensus. At the time of image analysis, the investigators were blinded with respect to autopsy and histology results. Measurements of attenuation values were performed on axial slices at the height of the center of the intervertebral discs of the thoracic vertebral column at levels of vertebrae 2/3, 3/4, 4/5, 5/6, 6/7 and 7/8. On each axial image 6 ovoid ROIs of 0.3–0.9 cm2 were defined, 3 in the right and 3 in the left lung (anterior, central and posterior on both sides, Fig. 1). Potential overlap with structures other than lung tissue (ribs, mediastinal structures, pleural air or fluid) was carefully avoided, as each ROI was optimized for maximum size. For each ROI, the mean attenuation value was recorded.

Autopsy findings and flotation tests

After image analysis the results of autopsy reports were analyzed in a systematic fashion. Autopsies were conducted according to German legislation. Specifically, the results of the floatation tests of the lungs were recorded. It was found to be positive if the lungs floated on the surface, holding neck organs when immersed in water, or the lungs separately, or parts of the lungs floated on the surface. In the control group, flotation tests were not performed because all children had breathed freely at some point after birth and no child in this group had lived less than 24 h.

Histology

Histology provided the reference standard for the diagnosis of lung ventilation. All cases of the study and control groups were examined histologically. After fixation in buffered formalin solution and paraffin embedding routine serial sections were stained with hematoxylin and eosin staining (HE). A board-certified pathologist performed the histological examinations. Specimens were examined for aeration, packing of cells, aspiration, atelectasis, and infiltration.

Statistical analysis

Statistical analysis included the Mann-Whitney U‑test for continuous variables as well as a receiver operating characteristic (ROC) analysis to determine the best CT attenuation cut-off value for the distinction of ventilated and nonventilated lungs.
Statistical analysis was performed using SPSS version16.0.1 for Windows (IBM, Armonk, NY, USA).

Results

Study population

The study population included 38 neonatal and infant cadavers (Table 1) examined at the Institute of Forensic Medicine of the Ludwig Maximilians University Munich during the period from June 2008 to February 2012. The study group (group 1) comprised 17 infants with possible stillbirth and unclear cause of death.
Table 1
Demographics. Continuous variables are given as mean (± standard deviation, SD), categorical variables are given as absolute number and percentage of the total
 
Group 1
Group 2
Subgroup 1a
Subgroup 1b
Age at time of death
Perinatal
Perinatal
7.9 (±3.1) weeks
Sex
10 male/7 female
10 male/11 female
Height
50.8 (±3.96) cm
57.4 (±2.73) cm
Weight
3112 (±798) g
4578 (±1178) g
Time interval between death and PMCT
< 36 h
< 36 h
< 36 h
 
Height
Weight
Age
Group 1 (neonates)
50.8 cm (SD 4.08)
3112 g (SD 823)
Perinatal death
Group 2 (control)
57.4 cm (SD 2.73)
4578 g (SD 1178)
7.9 weeks (SD 3.1)
The control group (group 2) consisted of the remaining 21 infants with certain live birth. Of these 21 infants the cause of death was determined as sudden infant death syndrome (SIDS) in 17 cases, battered child syndrome with blunt cerebral trauma in 2 cases, 1 case had suffered a cerebral sinus thrombosis and 1 had died from accidental strangulation.

CT examination

The median time interval between PMCT and autopsy was less than 1 day, ranging from 4h to 24 h. An interval greater than 36 h between death and PMCT was excluded. Typical examples with histology are displayed in Figs. 2 and 3.
Of all examined ROIs the overall mean HU in the histologically nonventilated study group (group 1a) was 45 HU (SD 15 HU) versus −192 HU (SD 207 HU) in the ventilated study group (group 1b) whereas in the control group (group 2) mean CT attenuation was −219 HU (SD 135 HU) (Table 1). Differences of mean HU between groups 1a and 2, and 1a and 1b were statistically significant (both p < 0.001), while no significant difference was found between groups 1b and 2. No statistically significant differences could be found between the anatomic regions, when comparing ventral with dorsal areas or cranial with caudal areas (Table 2).
Table 2
CT attenuation of examined ROIs
 
N
Minimum
Maximum
Mean
Std. Deviation
Nonventilated (1a)
313
−50
72
45.25
15.617
Ventilated (1b)
917
−817
67
−192.10
207.602
Control group (2)
708
−684
33
−219.60
135.675
Mean HU values of all ROIs are illustrated in histograms (Fig. 4a–c). Note the similar distributions of CT attenuation values for ventilated lungs in study group and control group. While the shape of the distribution curve is similar in nonventilated specimens, the mean values differ strongly between ventilated and nonventilated lungs.
Mean and median densities of the nonventilated (1a) against ventilated study group (1b) showed a significantly different result (p < 0.05).
When comparing the control group (2) with the ventilated study group, no significant difference was found.
A receiver operating characteristic (ROC) analysis of the mean HU provided an optimal cut-off value of −35 HU.
Using the mentioned cut-off value of −35 HU results in sensitivity, specificity, positive and negative predictive value, and accuracy of 86%, 90%, 86%, 90%, and 88% respectively, for the discrimination of ventilated and nonventilated lungs in the study group.

Flotation test and histology

A negative test was interpreted as nonventilated lungs (stillborn), a positive test was interpreted as ventilated lungs (survived birth). In the study group a flotation test was done in all cases. It was found to be negative in 10 out of the 17 cases and positive in the remaining 7 cases; the result was confirmed by histology in 15 out of 17 cases. Those cases with unconfirmed result are discussed further.
In the control group, due to the fact that these infants had lived for at least 3 weeks, flotation tests were not applied during autopsy.

Control group (group 2)

The ventilated lungs of the control group showed uniform patterns of well-aerated and developed tissue: Dilated terminal bronchioli as well as open alveolar spaces intermingled with artificially collapsed tissue areas. Higher magnifications showed open alveolar spaces with a single, flattened cell layer on the alveolar septae.

Study group (group 1)

The cases in the study group that presented with high attenuation and negative flotation test showed no histological signs of ventilation in all cases but one. The bronchial wall involved immature cartilage tissue; the lung parenchyma was densely packed and displayed an abundance of hyperaemic capillaries. The alveolar walls were closely packed without any open spaces between the alveolar septae. Lung parenchyma in some of these cases furthermore showed artificially dilated alveolar spaces with small amounts of fluid in central portions. Pneumocytes had lost contact to the alveolar basal membrane, were rounded and hydropically swollen. Numerous erythrocytes were present within the lung capillaries as sign of congestion.
Two cases of the study group showed a different pattern due to acute infection and putrefaction, respectively. They explain the singular false negative and false positive results. In these cases, histology was essential to determine the correct diagnosis. One of these cases showed a negative flotation test and a mean attenuation of 46.1 HU (SD 5.3 HU); histology revealed acute pneumonia. The second case showed a partially positive lung flotation, with a mean attenuation of 22.1 HU (SD 32.1 HU); histology revealed that the alveoli were still densely packed, immature cartilage prevailed the overall picture, detritus and fluids combined with a bubbly appearance, so the diagnosis of an unventilated but putrefied lung was established.

Discussion

The ventilation status of newborn lungs has been a constant topic in forensic medicine. From the very early conceptions of flotation tests by Johannes Schreyer in 1690 [9] to recent studies utilizing imaging techniques, mainly CT [913], proving that a newborn has been alive is mainly based on these findings, with histology as gold standard in ambiguous cases. The flotation test has been discussed extensively [3, 4, 14], its use criticized but maintained until today. It is known to deliver unreliable results in cases of putrefaction or infections. Our results indicate that the attenuation value of PMCT with the appropriate cut-off value is equally well suited, but with the same shortcomings as the flotation test to determine lung ventilation.
These numbers might add to a basis of forensic radiological knowledge that is necessary to interpret post-mortem CT. It seems obvious that ventilated lungs should show lower attenuation; however, our study was sufficiently large to support this hypothesis with statistical significance. Based on these results and our experience we believe that our cut-off values allow for a sufficiently reliable distinction between ventilated and nonventilated lungs within forensic requirements. The calculated optimal cut-off value is remarkably high when compared to regular lung parenchyma, but therefore should also include aerated lungs with moderate infiltrations.
The histograms of the mean HU distributions illustrate well how accurate the discrimination is.
Unfortunately, the study design is not able to discriminate artificially ventilated lungs from lungs of children having actively breathed, but the same is true for the flotation test.
In addition to the results of previous studies, our results suggest a useful cut-off value for mean pulmonary CT attenuation of −35 HU. Using this cut-off value, PMCT can be expected to accurately mirror results of a floatation test and to correctly determine the ventilation status of infant lungs in the vast majority of cases. It might be interesting to evaluate the amount of gas in the gastrointestinal tract to differentiate between natural breathing and ventilation in intubated patients. When we compared only neonates, we found relatively high values for sensitivity, specificity, positive and negative predictive values, and accuracy, concurring with forensic requirements, to be confirmed with histology in ambiguous cases.
Errors can occur especially in cases of live birth with pulmonary infiltration (e.g. pneumonia, pulmonary edema), or stillbirth with either advanced putrefaction or external ventilation, because these changes affect the measurable pulmonary attenuation; however, the flotation test is subject to the same errors for the same reasons. The CT in these cases is at this point not suitable to replace a histological examination, but it should render the flotation test unnecessary. Considering that every deceased infant or newborn should ideally undergo a PMCT screening for traumatic injury, the CT-based lung ventilation status would be a useful by-product, and a flotation test would not be necessary anymore.
Isolated putrefaction of lungs would be a rare finding [4], which reflects routine autopsy experience. If it occurs, aspiration, e.g. of stomach contents, has to be considered, which may be diagnosed on PMCT by an experienced reader. PMCT examinations can establish a distribution pattern of gas, which can be used to stage putrefaction [2]. Application of the radiological alteration index (RAI) might be a way to optimize the reliability of a PMCT-based lung ventilation status. We did not calculate the RAI, because it is currently not evaluated for children, this might be an interesting topic of future research.
On the other hand, lung infiltration patterns on PMCT often hint at their pathological cause if interpreted by an experienced reader. Thus, PMCT can help to identify ambiguous cases and to determine if further histological evaluation is necessary or not.
In addition to evaluating lung ventilation and its reliability, PMCT offers various other advantages. The changes inflicted to bodies by resuscitation efforts very often result in a gas-distended stomach or pneumothorax, because of the mainly used initial approach of bag-mask ventilation. CT easily evaluates this due to its sensitivity to the presence of even small amounts of gas. Furthermore, in contrast to the flotation test, PMCT can be re-evaluated at any time after the initial interpretation, if necessary. Logistically, if PMCT is performed for its other advantages, an additional flotation test is unnecessary.
In comparison with post-mortem magnetic resonance imaging (MRI), CT seems better suited for evaluation of the ventilation status of newborn lungs for a number of reasons [13, 15, 16]. Firstly, CT is more widely available, cheaper, easier to interpret and the examination time is shorter. Secondly, its physical principle is closer to the flotation test, as the attenuation value is related to the physical density of an object and thus better reflects the rationale behind the flotation test, which also very simply measures lung density compared to water. The MRI on the other hand only measures signal intensity, which is not correlated with physical density and shows a dependence on temperature [17]. Also, MRI can be expected to be less precise for determining the presence of gas, because various conditions can exhibit low signal intensity, e.g. calcifications such as gas are hypointense on all sequences and can thus easily be confounded.
This study has some limitations.
Firstly, a control group of stillborn infants was not included, because these are very rarely examined for ethical reasons and if they are, the examination generally takes place in the department of clinical pathology, access was therefore limited. The inclusion of a control group of stillborn infants was considered less important, because we expected a relatively uniform attenuation distribution for ventilated lungs compared to a less homogeneous distribution of attenuation in nonventilated lungs. Furthermore, the difference in attenuation between ventilated and nonventilated lungs was expected to be high, so that a control group of one of the two states of ventilation was considered sufficient. Also, and most importantly, histological evaluation was used as reference to clearly diagnose ambiguous cases. Because of using the histological examination as ground truth, all cases examined could be used to determine a cut-off value for lung attenuation to distinguish ventilated from nonventilated lungs and the total case number for both ventilated and nonventilated lungs was sufficient for statistical evaluation.
Secondly, the examined group of infants is still small. Nonetheless, it is to our knowledge larger than any other case group published in this context. It also allows for statistical evaluation and therefore is less likely to be biased than previous studies.
Thirdly, since the control group (group 2) was chosen retrospectively, we could not perform a floatation test on these. Since all infants in the control group had lived well beyond birth and at least at some point after birth had breathed freely as proof of lung ventilation, we considered a flotation test unnecessary.

Conclusion

Lung attenuation values from PMCT allow for a reliable distinction between ventilated and nonventilated lungs using a cut-off value of −35 HU in newborns.
Using this cut-off value, PMCT and flotation test deliver identical results for diagnosing lung ventilation with a sensitivity of 86% and a specificity of 90%. When PMCT is performed in infants, an additional flotation test can be considered unnecessary. In ambiguous cases, PMCT and flotation test both need to be complemented with histological work-up.

Declarations

Conflict of interest

F. T. Fischer, M. Schwerer, S. Lochner, D. Maxien, F. Mück, L. Bechstein, S. Wirth and J. Grimm declare that they have no competing interests.
All investigations on humans or human tissues described in this article were carried out with the approval of the responsible ethics committee, in accordance with national law and the Declaration of Helsinki from 1975 (in its current revised form). The investigations were carried out according to the specifications of the Central Ethics Committee of the Federal Medical Council.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Unsere Produktempfehlungen

Rechtsmedizin

Print-Titel

• Einzige deutschsprachige Zeitschrift für Rechtsmedizinerinnen und Rechtsmediziner

• Ausgewählte Übersichtsbeiträge zu aktuellen Themenschwerpunkten

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Literatur
12.
Metadaten
Titel
Post-mortem computed tomography is a useful tool for determining the pulmonary ventilation status in newborns
verfasst von
Florian T. Fischer
Michael Schwerer
Stefanie Lochner
Daniel Maxien
Fabian Mück
Laura Bechstein
Stefan Wirth
Jochen Grimm
Publikationsdatum
19.10.2021
Verlag
Springer Medizin
Erschienen in
Rechtsmedizin / Ausgabe 4/2022
Print ISSN: 0937-9819
Elektronische ISSN: 1434-5196
DOI
https://doi.org/10.1007/s00194-021-00536-y

Weitere Artikel der Ausgabe 4/2022

Rechtsmedizin 4/2022 Zur Ausgabe

Rechtsprechung

Rechtsreport

Neu im Fachgebiet Rechtsmedizin