Skip to main content
Erschienen in: International Journal of Legal Medicine 1/2018

14.09.2017 | Original Article

Postmortem MR diffusion-weighted imaging of the liver: time-behavior of the hepatic apparent diffusion coefficient in the early death interval

verfasst von: Sarah Keller, Tony M. Schmidt, Anne Catherine Kim, Roland Fischer, Axel Heinemann, Gerhard Adam, Jin Yamamura

Erschienen in: International Journal of Legal Medicine | Ausgabe 1/2018

Einloggen, um Zugang zu erhalten

Abstract

Objective

The objective of this study is to assess postmortem changes of the hepatic apparent diffusion coefficient (ADC) at multiple time points in the time interval of 16 hours postmortem in comparison to in vivo controls and to literature data.

Material and methods

Hepatic diffusion-weighted imaging (DWI) was repeatedly performed at 1.5 Tesla (b values 50, 400, and 800 s/mm2) in 2-hourly steps within 16 hours postmortem in 19 cases (male to female 13:6, mean age 68.5 ± 12.2 years) and 5 in vivo controls. The core body temperature was measured rectally prior to every scan. Mean ADC values were calculated from regions of interest (ROIs) and compared to in vivo healthy controls and to literature data of normal liver parenchyma. Spearman rank correlation and Levenberg-Marquardt algorithm were used to assess a relationship between postmortem core body temperature and ADC values.

Results

Mean hepatic ADC values were significantly lower in postmortem cases than in in vivo controls (52.0 ± 15.0 · 10−5 mm2/s vs. 111.0 ± 15.7 · 10−5 mm2/s, p < 0.0001). The ex vivo liver ADC correlated inversely to calculated liver temperature (−3.5 ± 0.8) · 10−5 mm2/s/°C, r = −0.44, p < 0.0001. At low calculated liver temperature (< 30 °C), the ADC described an average increase of (22 ± 10) · 10−5 mm2/s/°C.

Conclusion

Hepatic ADC values show a characteristic change in the immediate 16 hours postmortem, which is influenced by the postmortem liver temperature change. With the knowledge of characteristic postmortem liver changes, diffusion-weighted imaging could be added to conventional postmortem MRI for virtual autopsy.
Literatur
4.
Zurück zum Zitat Breeze AC, Jessop FA, Set PA, Whitehead AL, Cross JJ, Lomas DJ, Hackett GA, Joubert I, Lees CC (2011) Minimally-invasive fetal autopsy using magnetic resonance imaging and percutaneous organ biopsies: clinical value and comparison to conventional autopsy. Ultrasound Obstet Gynecol 37(3):317–323. https://doi.org/10.1002/uog.8844 PubMedCrossRef Breeze AC, Jessop FA, Set PA, Whitehead AL, Cross JJ, Lomas DJ, Hackett GA, Joubert I, Lees CC (2011) Minimally-invasive fetal autopsy using magnetic resonance imaging and percutaneous organ biopsies: clinical value and comparison to conventional autopsy. Ultrasound Obstet Gynecol 37(3):317–323. https://​doi.​org/​10.​1002/​uog.​8844 PubMedCrossRef
6.
Zurück zum Zitat Thayyil S, Sebire NJ, Chitty LS, Wade A, Chong W, Olsen O, Gunny RS, Offiah AC, Owens CM, Saunders DE, Scott RJ, Jones R, Norman W, Addison S, Bainbridge A, Cady EB, Vita ED, Robertson NJ, Taylor AM, group Mc (2013) Post-mortem MRI versus conventional autopsy in fetuses and children: a prospective validation study. Lancet 382(9888):223–233. https://doi.org/10.1016/S0140-6736(13)60134-8 PubMedCrossRef Thayyil S, Sebire NJ, Chitty LS, Wade A, Chong W, Olsen O, Gunny RS, Offiah AC, Owens CM, Saunders DE, Scott RJ, Jones R, Norman W, Addison S, Bainbridge A, Cady EB, Vita ED, Robertson NJ, Taylor AM, group Mc (2013) Post-mortem MRI versus conventional autopsy in fetuses and children: a prospective validation study. Lancet 382(9888):223–233. https://​doi.​org/​10.​1016/​S0140-6736(13)60134-8 PubMedCrossRef
7.
Zurück zum Zitat Fiehler J, Fiebach JB, Gass A, Hoehn M, Kucinski T, Neumann-Haefelin T, Schellinger PD, Siebler M, Villringer A, Rother J (2002) Diffusion-weighted imaging in acute stroke—a tool of uncertain value? Cerebrovasc Dis 14(3-4):187–196 doi:65675PubMedCrossRef Fiehler J, Fiebach JB, Gass A, Hoehn M, Kucinski T, Neumann-Haefelin T, Schellinger PD, Siebler M, Villringer A, Rother J (2002) Diffusion-weighted imaging in acute stroke—a tool of uncertain value? Cerebrovasc Dis 14(3-4):187–196 doi:65675PubMedCrossRef
12.
Zurück zum Zitat Al-Alousi LM, Anderson RA, Worster DM, Land DV (2002) Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF). Part I. A study of the effect of body variables and covering of the torso on the postmortem brain, liver and rectal cooling rates in 117 forensic cases. Forensic Sci Int 125(2–3):223–230PubMedCrossRef Al-Alousi LM, Anderson RA, Worster DM, Land DV (2002) Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF). Part I. A study of the effect of body variables and covering of the torso on the postmortem brain, liver and rectal cooling rates in 117 forensic cases. Forensic Sci Int 125(2–3):223–230PubMedCrossRef
13.
Zurück zum Zitat Al-Alousi LM, Anderson RA, Worster DM, Land DV (2002) Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF). Part II. A study of the effect of body temperature at the moment of death on the postmortem brain, liver and rectal cooling in 117 forensic cases. Forensic Sci Int 125(2–3):231–236PubMedCrossRef Al-Alousi LM, Anderson RA, Worster DM, Land DV (2002) Factors influencing the precision of estimating the postmortem interval using the triple-exponential formulae (TEF). Part II. A study of the effect of body temperature at the moment of death on the postmortem brain, liver and rectal cooling in 117 forensic cases. Forensic Sci Int 125(2–3):231–236PubMedCrossRef
14.
Zurück zum Zitat Henssge C, Brinkmann B, Puschel K (1984) Determination of the time of death by measurement of rectal temperature of corpses suspended in water. Z Rechtsmed 92(4):255–276PubMedCrossRef Henssge C, Brinkmann B, Puschel K (1984) Determination of the time of death by measurement of rectal temperature of corpses suspended in water. Z Rechtsmed 92(4):255–276PubMedCrossRef
16.
21.
Zurück zum Zitat Garcia-Valdecasas JC, Tabet J, Valero R, Deulofeu R, Taura P, Rull R, Capdevila L, Cifuentes A, Gonzalez FX, Net M, Beltran J, Lopez-Boado MA, Palacin J, Garcia F, Visa J (1999) Evaluation of ischemic injury during liver procurement from non-heart-beating donors. Eur Surg Res 31(6):447–456 doi:8724PubMedCrossRef Garcia-Valdecasas JC, Tabet J, Valero R, Deulofeu R, Taura P, Rull R, Capdevila L, Cifuentes A, Gonzalez FX, Net M, Beltran J, Lopez-Boado MA, Palacin J, Garcia F, Visa J (1999) Evaluation of ischemic injury during liver procurement from non-heart-beating donors. Eur Surg Res 31(6):447–456 doi:8724PubMedCrossRef
23.
Zurück zum Zitat Hutchins GM (1985) Body temperature is elevated in the early postmortem period. Hum Pathol 16(6):560–561PubMedCrossRef Hutchins GM (1985) Body temperature is elevated in the early postmortem period. Hum Pathol 16(6):560–561PubMedCrossRef
Metadaten
Titel
Postmortem MR diffusion-weighted imaging of the liver: time-behavior of the hepatic apparent diffusion coefficient in the early death interval
verfasst von
Sarah Keller
Tony M. Schmidt
Anne Catherine Kim
Roland Fischer
Axel Heinemann
Gerhard Adam
Jin Yamamura
Publikationsdatum
14.09.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Legal Medicine / Ausgabe 1/2018
Print ISSN: 0937-9827
Elektronische ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-017-1685-4

Weitere Artikel der Ausgabe 1/2018

International Journal of Legal Medicine 1/2018 Zur Ausgabe

Neu im Fachgebiet Rechtsmedizin