Abstract

This study aimed to assess the reliability of stroke volume variation (SVV) in predicting cardiac output (CO) decrease and hypotension during induction of general anesthesia. Forty-five patients undergoing abdominal surgery under general anesthesia were enrolled. Before induction of anesthesia, patients were required to maintain deep breathing (6–8 times/min), and pre-anesthetic SVV was measured for 1 min by electrical cardiometry. General anesthesia was induced with propofol, remifentanil, rocuronium, and sevoflurane. Study duration was defined from the start of fluid administration till 5 min after tracheal intubation. Blood pressure (BP) was measured every minute. Cardiac output was measured continuously by electrical cardiometry. Receiver operating characteristics (ROC) curves were made regarding the incidence of decreased CO (less than 70% of the baseline) and hypotension (mean BP <65 mmHg). The risk of developing decreased CO and hypotension was evaluated by multivariate logistic regression analysis. The time from the start of the procedure to onset of decreased CO was analyzed by the Kaplan–Meier method. The area under the ROC curve and optimal threshold value of pre-anesthetic SVV for predicting decreased CO and hypotension were 0.857 and 0.693. Patients with lower SVV exhibited a significantly slower onset and lower incidence of decreased CO than those with higher SVV (p = 0.003). Multivariate logistic regression analysis indicated high pre-anesthetic SVV as being an independent risk factor for decreased CO and hypotension (odds ratio, 1.43 and 1.16, respectively). In conclusions, pre-anesthetic SVV can predict incidence of decreased CO and hypotension during induction of general anesthesia.
Literatur
1.
Zurück zum Zitat Bijker JB, van Klei WA, Kappen TH, van Wolfswinkel L, Moons KG, Kalkman CJ. Incidence of intraoperative hypotension as a function of the chosen definition: literature definitions applied to a retrospective cohort using automated data collection. Anesthesiology. 2007;107:213–20.CrossRefPubMed Bijker JB, van Klei WA, Kappen TH, van Wolfswinkel L, Moons KG, Kalkman CJ. Incidence of intraoperative hypotension as a function of the chosen definition: literature definitions applied to a retrospective cohort using automated data collection. Anesthesiology. 2007;107:213–20.CrossRefPubMed
2.
Zurück zum Zitat Zhang J, Critchley LA. Inferior vena cava ultrasonography before general anesthesia can predict hypotension after induction. Anesthesiology. 2016;124:580–9.CrossRefPubMed Zhang J, Critchley LA. Inferior vena cava ultrasonography before general anesthesia can predict hypotension after induction. Anesthesiology. 2016;124:580–9.CrossRefPubMed
3.
Zurück zum Zitat Lima EQ, Zanetta DM, Castro I, Massarollo PC, Mies S, Machado MM, Yu L. Risk factors for development of acute renal failure after liver transplantation. Ren Fail. 2003;25:553–60.CrossRefPubMed Lima EQ, Zanetta DM, Castro I, Massarollo PC, Mies S, Machado MM, Yu L. Risk factors for development of acute renal failure after liver transplantation. Ren Fail. 2003;25:553–60.CrossRefPubMed
4.
Zurück zum Zitat Latson TW, Ashmore TH, Reinhart DJ, Klein KW, Giesecke AH. Autonomic reflex dysfunction in patients presenting for elective surgery is associated with hypotension after anesthesia induction. Anesthesiology. 1994;80:326–37.CrossRefPubMed Latson TW, Ashmore TH, Reinhart DJ, Klein KW, Giesecke AH. Autonomic reflex dysfunction in patients presenting for elective surgery is associated with hypotension after anesthesia induction. Anesthesiology. 1994;80:326–37.CrossRefPubMed
5.
Zurück zum Zitat Lonjaret L, Lairez O, Minville V, Geeraerts T. Optimal perioperative management of arterial blood pressure. Integr Blood Press Control. 2014;7:49–59.CrossRefPubMedPubMedCentral Lonjaret L, Lairez O, Minville V, Geeraerts T. Optimal perioperative management of arterial blood pressure. Integr Blood Press Control. 2014;7:49–59.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Lin FQ, Li C, Zhang LJ, Fu SK, Chen GQ, Yang XH, Zhu CY, Li Q. Effect of rapid plasma volume expansion during anesthesia induction on haemodynamics and oxygen balance in patients undergoing gastrointestinal surgery. Int J Med Sci. 2013;10:355–61.CrossRefPubMedPubMedCentral Lin FQ, Li C, Zhang LJ, Fu SK, Chen GQ, Yang XH, Zhu CY, Li Q. Effect of rapid plasma volume expansion during anesthesia induction on haemodynamics and oxygen balance in patients undergoing gastrointestinal surgery. Int J Med Sci. 2013;10:355–61.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat van Waes JA, van Klei WA, Wijeysundera DN, van Wolfswinkel L, Lindsay TF, Beattie WS. Association between intraoperative hypotension and myocardial injury after vascular surgery. Anesthesiology. 2016;124:35–44.CrossRefPubMed van Waes JA, van Klei WA, Wijeysundera DN, van Wolfswinkel L, Lindsay TF, Beattie WS. Association between intraoperative hypotension and myocardial injury after vascular surgery. Anesthesiology. 2016;124:35–44.CrossRefPubMed
8.
Zurück zum Zitat Onuigbo MA, Agbasi N. Association of intraoperative hypotension with acute kidney injury after elective non-cardiac surgery-prevention is better than cure. Ren Fail. 2016;38:168–9.CrossRefPubMed Onuigbo MA, Agbasi N. Association of intraoperative hypotension with acute kidney injury after elective non-cardiac surgery-prevention is better than cure. Ren Fail. 2016;38:168–9.CrossRefPubMed
9.
Zurück zum Zitat Bijker JB, van Klei WA, Vergouwe Y, Eleveld DJ, van Wolfswinkel L, Moons KG, Kalkman CJ. Intraoperative hypotension and 1-year mortality after noncardiac surgery. Anesthesiology. 2009;111:1217–26.CrossRefPubMed Bijker JB, van Klei WA, Vergouwe Y, Eleveld DJ, van Wolfswinkel L, Moons KG, Kalkman CJ. Intraoperative hypotension and 1-year mortality after noncardiac surgery. Anesthesiology. 2009;111:1217–26.CrossRefPubMed
10.
Zurück zum Zitat Walsh M, Devereaux PJ, Garg AX, Kurz A, Turan A, Rodseth RN, Cywinski J, Thabane L, Sessler DI. Relationship between intraoperative mean arterial pressure and clinical outcomes after noncardiac surgery: toward an empirical definition of hypotension. Anesthesiology. 2013;119:507–15.CrossRefPubMed Walsh M, Devereaux PJ, Garg AX, Kurz A, Turan A, Rodseth RN, Cywinski J, Thabane L, Sessler DI. Relationship between intraoperative mean arterial pressure and clinical outcomes after noncardiac surgery: toward an empirical definition of hypotension. Anesthesiology. 2013;119:507–15.CrossRefPubMed
11.
Zurück zum Zitat Lienhart A, Auroy Y, Pequignot F, Benhamou D, Warszawski J, Bovet M, Jougla E. Survey of anesthesia-related mortality in France. Anesthesiology. 2006;105:1087–97.CrossRefPubMed Lienhart A, Auroy Y, Pequignot F, Benhamou D, Warszawski J, Bovet M, Jougla E. Survey of anesthesia-related mortality in France. Anesthesiology. 2006;105:1087–97.CrossRefPubMed
12.
Zurück zum Zitat Kim KM, Gwak MS, Choi SJ, Kim MH, Park MH, Heo BY. Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy. Korean J Anesthesiol. 2013;65:237–243.CrossRefPubMedPubMedCentral Kim KM, Gwak MS, Choi SJ, Kim MH, Park MH, Heo BY. Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy. Korean J Anesthesiol. 2013;65:237–243.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Suehiro K, Tanaka K, Mukai A, Joosten A, Desebbe O, Alexander B, Cannesson M, Nishikawa K. Hemodynamic monitoring and management in high-risk surgery: a survey among Japanese anesthesiologists. J Anesth. 2016;30:526–9.CrossRefPubMed Suehiro K, Tanaka K, Mukai A, Joosten A, Desebbe O, Alexander B, Cannesson M, Nishikawa K. Hemodynamic monitoring and management in high-risk surgery: a survey among Japanese anesthesiologists. J Anesth. 2016;30:526–9.CrossRefPubMed
14.
Zurück zum Zitat Suehiro K, Rinka H, Ishikawa J, Fuke A, Arimoto H, Miyaichi T. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation. Anaesth Intensive Care. 2012;40:767–72.PubMed Suehiro K, Rinka H, Ishikawa J, Fuke A, Arimoto H, Miyaichi T. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation. Anaesth Intensive Care. 2012;40:767–72.PubMed
15.
Zurück zum Zitat Suehiro K, Okutani R. Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation. J Anesth. 2011;25:777–80.CrossRefPubMed Suehiro K, Okutani R. Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation. J Anesth. 2011;25:777–80.CrossRefPubMed
16.
Zurück zum Zitat Suehiro K, Okutani R. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing one-lung ventilation. J Cardiothorac Vasc Anesth. 2010;24:772–5.CrossRefPubMed Suehiro K, Okutani R. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing one-lung ventilation. J Cardiothorac Vasc Anesth. 2010;24:772–5.CrossRefPubMed
17.
Zurück zum Zitat Suehiro K, Tanaka K, Matsuura T, Funao T, Yamada T, Mori T, Nishikawa K. The Vigileo-FloTrac system: arterial waveform analysis for measuring cardiac output and predicting fluid responsiveness: a clinical review. J Cardiothorac Vasc Anesth. 2014;28:1361–74.CrossRefPubMed Suehiro K, Tanaka K, Matsuura T, Funao T, Yamada T, Mori T, Nishikawa K. The Vigileo-FloTrac system: arterial waveform analysis for measuring cardiac output and predicting fluid responsiveness: a clinical review. J Cardiothorac Vasc Anesth. 2014;28:1361–74.CrossRefPubMed
18.
Zurück zum Zitat Suehiro K, Tanaka K, Yamada T, Matsuura T, Mori T, Funao T, Nishikawa K. The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation. J Clin Monit Comput. 2015;29:333–9.CrossRefPubMed Suehiro K, Tanaka K, Yamada T, Matsuura T, Mori T, Funao T, Nishikawa K. The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation. J Clin Monit Comput. 2015;29:333–9.CrossRefPubMed
19.
Zurück zum Zitat Slagt C, Malagon I, Groeneveld AB. Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation. Br J Anaesth. 2014;112:626–37.CrossRefPubMed Slagt C, Malagon I, Groeneveld AB. Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation. Br J Anaesth. 2014;112:626–37.CrossRefPubMed
20.
Zurück zum Zitat Hanss R, Renner J, Ilies C, Moikow L, Buell O, Steinfath M, Scholz J, Bein B. Does heart rate variability predict hypotension and bradycardia after induction of general anaesthesia in high risk cardiovascular patients? Anaesthesia. 2008;63:129–35.CrossRefPubMed Hanss R, Renner J, Ilies C, Moikow L, Buell O, Steinfath M, Scholz J, Bein B. Does heart rate variability predict hypotension and bradycardia after induction of general anaesthesia in high risk cardiovascular patients? Anaesthesia. 2008;63:129–35.CrossRefPubMed
21.
Zurück zum Zitat Tsuchiya M, Yamada T, Asada A. Pleth variability index predicts hypotension during anesthesia induction. Acta Anaesthesiol Scand. 2010;54:596–602.CrossRefPubMed Tsuchiya M, Yamada T, Asada A. Pleth variability index predicts hypotension during anesthesia induction. Acta Anaesthesiol Scand. 2010;54:596–602.CrossRefPubMed
22.
Zurück zum Zitat Derichard A, Robin E, Tavernier B, Costecalde M, Fleyfel M, Onimus J, Lebuffe G, Chambon JP, Vallet B. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth. 2009;103:678–84.CrossRefPubMed Derichard A, Robin E, Tavernier B, Costecalde M, Fleyfel M, Onimus J, Lebuffe G, Chambon JP, Vallet B. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth. 2009;103:678–84.CrossRefPubMed
23.
Zurück zum Zitat Ramsingh DS, Sanghvi C, Gamboa J, Cannesson M, Applegate RL 2nd. Outcome impact of goal directed fluid therapy during high risk abdominal surgery in low to moderate risk patients: a randomized controlled trial. J Clin Monit Comput. 2013;27:249–57.CrossRefPubMed Ramsingh DS, Sanghvi C, Gamboa J, Cannesson M, Applegate RL 2nd. Outcome impact of goal directed fluid therapy during high risk abdominal surgery in low to moderate risk patients: a randomized controlled trial. J Clin Monit Comput. 2013;27:249–57.CrossRefPubMed
24.
Zurück zum Zitat Salmasi V, Maheshwari K, Yang D, Mascha EJ, Singh A, Sessler DI, Kurz A. Relationship between intraoperative hypotension, defined by either reduction from baseline or absolute thresholds, and acute kidney and myocardial injury after noncardiac surgery: a retrospective cohort analysis. Anesthesiology. 2017;126:47–65.CrossRefPubMed Salmasi V, Maheshwari K, Yang D, Mascha EJ, Singh A, Sessler DI, Kurz A. Relationship between intraoperative hypotension, defined by either reduction from baseline or absolute thresholds, and acute kidney and myocardial injury after noncardiac surgery: a retrospective cohort analysis. Anesthesiology. 2017;126:47–65.CrossRefPubMed
25.
Zurück zum Zitat Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.CrossRefPubMed Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.CrossRefPubMed
26.
Zurück zum Zitat De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23.CrossRefPubMed De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23.CrossRefPubMed
27.
Zurück zum Zitat Heenen S, De Backer D, Vincent JL. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care. 2006;10:R102.CrossRefPubMedPubMedCentral Heenen S, De Backer D, Vincent JL. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care. 2006;10:R102.CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Soubrier S, Saulnier F, Hubert H, Delour P, Lenci H, Onimus T, Nseir S, Durocher A. Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med. 2007;33:1117–24.CrossRefPubMed Soubrier S, Saulnier F, Hubert H, Delour P, Lenci H, Onimus T, Nseir S, Durocher A. Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med. 2007;33:1117–24.CrossRefPubMed
29.
Zurück zum Zitat Bronzwaer AS, Ouweneel DM, Stok WJ, Westerhof BE, van Lieshout JJ. Arterial pressure variation as a biomarker of preload dependency in spontaneously breathing subjects—a proof of principle. PLoS ONE. 2015;10:e0137364.CrossRefPubMedPubMedCentral Bronzwaer AS, Ouweneel DM, Stok WJ, Westerhof BE, van Lieshout JJ. Arterial pressure variation as a biomarker of preload dependency in spontaneously breathing subjects—a proof of principle. PLoS ONE. 2015;10:e0137364.CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Suehiro K, Joosten A, Murphy LS, Desebbe O, Alexander B, Kim SH, Cannesson M. Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis. J Clin Monit Comput. 2016;30:603–20.CrossRefPubMed Suehiro K, Joosten A, Murphy LS, Desebbe O, Alexander B, Kim SH, Cannesson M. Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis. J Clin Monit Comput. 2016;30:603–20.CrossRefPubMed
31.
Zurück zum Zitat Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Schalte G. Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand. 2007;51:1314–9.CrossRefPubMed Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Schalte G. Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand. 2007;51:1314–9.CrossRefPubMed
32.
Zurück zum Zitat Joosten A, Desebbe O, Suehiro K, Murphy LS, Essiet M, Alexander B, Fischer MO, Barvais L, Van Obbergh L, Maucort-Boulch D, Cannesson M. Accuracy and precision of non-invasive cardiac output monitoring devices in perioperative medicine: a systematic review and meta-analysisdagger. Br J Anaesth. 2017;118:298–310.CrossRefPubMed Joosten A, Desebbe O, Suehiro K, Murphy LS, Essiet M, Alexander B, Fischer MO, Barvais L, Van Obbergh L, Maucort-Boulch D, Cannesson M. Accuracy and precision of non-invasive cardiac output monitoring devices in perioperative medicine: a systematic review and meta-analysisdagger. Br J Anaesth. 2017;118:298–310.CrossRefPubMed
33.
Zurück zum Zitat Min JJ, Lee JH, Hong KY, Choi SJ. Utility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position. J Clin Monit Comput. 2017;31:397–405.CrossRefPubMed Min JJ, Lee JH, Hong KY, Choi SJ. Utility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position. J Clin Monit Comput. 2017;31:397–405.CrossRefPubMed
Metadaten
Titel
Pre-anesthetic stroke volume variation can predict cardiac output decrease and hypotension during induction of general anesthesia
verfasst von
Takashi Juri
Koichi Suehiro
Sayaka Tsujimoto
Shigemune Kuwata
Akira Mukai
Katsuaki Tanaka
Tokuhiro Yamada
Takashi Mori
Kiyonobu Nishikawa
Publikationsdatum
24.06.2017
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 3/2018
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-017-0038-7

Weitere Artikel der Ausgabe 3/2018

Journal of Clinical Monitoring and Computing 3/2018 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.