Skip to main content
Erschienen in: International Ophthalmology 3/2017

20.07.2016 | Original Paper

Precut cornea for Descemet’s stripping endothelial keratoplasty: experience at a single eye bank

verfasst von: Ashik Mohamed, Sunita Chaurasia, Venkataswamy Chandragiri, Srinivas Kandhibanda, Srinivas Gunnam, Prashant Garg

Erschienen in: International Ophthalmology | Ausgabe 3/2017

Einloggen, um Zugang zu erhalten

Abstract

The aim of the study is to describe the experience with precut facility for endothelial keratoplasty at a single eye bank affiliated to a tertiary eye care center in India. Data on precut tissues from Nov 2012 to Dec 2014 were retrospectively reviewed from the electronic database of the eye bank of a tertiary eye care center in South India. Donor characteristic data including donor age, precut and postcut endothelial cell density (ECD), recipient age, and thickness of graft were collected. The number of precuts increased from 42 in 2012 (Nov and Dec) and 422 in 2013 to 584 in 2014. Of the total of 1048 precuts, seven (0.67 %) were miscut and could not be utilized for transplants. The donor age ranged from 2 to 89 years. A mean change of 43.6 ± 325.2 cells/mm2 in ECD was noted after cut, proportional increase in mean being 1.9 %. The change in ECD after cut was negatively correlated with ECD before cut. The recipient age ranged from 1 to 89 years. The median thickness of donor lenticule after cut was 148 µm (interquartile range 131–166 µm). Analysis of precut donor corneas from a single eye bank shows that the ECD of the processed tissues was excellent for transplantation. The tissue wastage in the hands of eye bank personal was minimal.
Literatur
1.
Zurück zum Zitat Chen ES, Terry MA, Shamie N, Hoar KL, Friend DJ (2008) Precut tissue in Descemet’s stripping automated endothelial keratoplasty donor characteristics and early postoperative complications. Ophthalmology 115(3):497–502CrossRefPubMed Chen ES, Terry MA, Shamie N, Hoar KL, Friend DJ (2008) Precut tissue in Descemet’s stripping automated endothelial keratoplasty donor characteristics and early postoperative complications. Ophthalmology 115(3):497–502CrossRefPubMed
2.
Zurück zum Zitat Nelson BA, Ritenour RJ (2014) Tissue quality of eye-bank-prepared precut corneas for Descemet’s stripping automated endothelial keratoplasty. Can J Ophthalmol 49(1):92–95CrossRefPubMed Nelson BA, Ritenour RJ (2014) Tissue quality of eye-bank-prepared precut corneas for Descemet’s stripping automated endothelial keratoplasty. Can J Ophthalmol 49(1):92–95CrossRefPubMed
3.
Zurück zum Zitat Katzman LR, Hoover CK, Khalifa YM, Jeng BH (2015) Assessment of the accuracy and cut-failure rates of eye bank-cut corneas for use in endothelial keratoplasty: a comparison of outcomes between 2010 and 2013. Cornea 34(11):1365–1368CrossRefPubMed Katzman LR, Hoover CK, Khalifa YM, Jeng BH (2015) Assessment of the accuracy and cut-failure rates of eye bank-cut corneas for use in endothelial keratoplasty: a comparison of outcomes between 2010 and 2013. Cornea 34(11):1365–1368CrossRefPubMed
4.
Zurück zum Zitat Price MO, Baig KM, Brubaker JW, Price FW Jr (2008) Randomized, prospective comparison of precut versus surgeon-dissected grafts for descemet stripping automated endothelial keratoplasty. Am J Ophthalmol 146(1):36–41CrossRefPubMed Price MO, Baig KM, Brubaker JW, Price FW Jr (2008) Randomized, prospective comparison of precut versus surgeon-dissected grafts for descemet stripping automated endothelial keratoplasty. Am J Ophthalmol 146(1):36–41CrossRefPubMed
5.
Zurück zum Zitat Liu YC, Alvarez Paraz CM, Cajucom-Uy HY, Agahari D, Sethuraman S, Tan DT et al (2014) Risk factors for donor endothelial loss in eye bank-prepared posterior lamellar corneal tissue for descemet stripping automated endothelial keratoplasty. Cornea 33(7):677–682CrossRefPubMed Liu YC, Alvarez Paraz CM, Cajucom-Uy HY, Agahari D, Sethuraman S, Tan DT et al (2014) Risk factors for donor endothelial loss in eye bank-prepared posterior lamellar corneal tissue for descemet stripping automated endothelial keratoplasty. Cornea 33(7):677–682CrossRefPubMed
6.
Zurück zum Zitat Kelliher C, Engler C, Speck C, Ward D, Farazdaghi S, Jun AS (2009) A comprehensive analysis of eye bank-prepared posterior lamellar corneal tissue for use in endothelial keratoplasty. Cornea 28(9):966–970CrossRefPubMed Kelliher C, Engler C, Speck C, Ward D, Farazdaghi S, Jun AS (2009) A comprehensive analysis of eye bank-prepared posterior lamellar corneal tissue for use in endothelial keratoplasty. Cornea 28(9):966–970CrossRefPubMed
7.
Zurück zum Zitat Price MO, Price FW Jr, Stoeger C, Soper M, Locke GD, Bavuso T (2008) Central thickness variation in precut DSAEK donor grafts. J Cataract Refract Surg 34(9):1423–1424CrossRefPubMed Price MO, Price FW Jr, Stoeger C, Soper M, Locke GD, Bavuso T (2008) Central thickness variation in precut DSAEK donor grafts. J Cataract Refract Surg 34(9):1423–1424CrossRefPubMed
Metadaten
Titel
Precut cornea for Descemet’s stripping endothelial keratoplasty: experience at a single eye bank
verfasst von
Ashik Mohamed
Sunita Chaurasia
Venkataswamy Chandragiri
Srinivas Kandhibanda
Srinivas Gunnam
Prashant Garg
Publikationsdatum
20.07.2016
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 3/2017
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-016-0297-1

Weitere Artikel der Ausgabe 3/2017

International Ophthalmology 3/2017 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.