Skip to main content
Erschienen in: Respiratory Research 1/2018

Open Access 01.12.2018 | Letter to the Editor

Predictors of clinical response to extrafine and non-extrafine particle inhaled corticosteroids in smokers and ex-smokers with asthma

verfasst von: Fajri Gafar, Ilse M. Boudewijn, Claire A. Cox, Judith M. Vonk, Siebrig Schokker, Anne J. Lexmond, Henderik W. Frijlink, Paul Hagedoorn, Dirkje S. Postma, Maarten van den Berge

Erschienen in: Respiratory Research | Ausgabe 1/2018

Abstract

We performed a post-hoc analysis of the OLiVIA-study investigating whether current and ex-smoking asthmatics with small airways dysfunction (SAD) show a better response in airway hyperresponsiveness (AHR) to small particle adenosine after treatment with extrafine compared to non-extrafine particle inhaled corticosteroids (ICS), and to investigate which clinical parameters predict a favorable response to both treatments. We show that smoking and ex-smoking asthmatics with and without SAD have a similar treatment response with either extrafine or non-extrafine particle ICS. We also found that lower blood neutrophils are associated with a smaller ICS-response in smokers and ex-smokers with asthma, independent from the level of blood eosinophils.
Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1186/​s12931-018-0961-2) contains supplementary material, which is available to authorized users.
Abkürzungen
ΔPD20
The change from baseline to post-treatment in the provocative dose of small particle adenosine causing a 20% drop in forced expiratory volume in 1 s (FEV1)
AHR
Airway hyperresponsiveness
AX
The area under curve of reactance
BMI
Body mass index
CFC
Chlorofluorocarbon
FEF25–75
Forced expiratory flow between 25 and 75% of FVC
FVC
Forced vital capacity
Fres
Resonance frequency
HFA
Hydrofluoroalkane
ICS
Inhaled corticosteroids
LCI
Lung clearance index
LLN
Lower limit of normal
R5-R20
The difference between resistance at 5 Hz and 20 Hz
RV
Residual volume
RV/TLC
The ratio of residual volume to total lung capacity
SAD
Small airways dysfunction
Sacin
Ventilation heterogeneity of the acinar structures
Scond
Ventilation heterogeneity of the conductive airways
TLC
Total lung capacity
ULN
Upper limit of normal
X5
The reactance at 5 Hz
Asthma patients who smoke experience more severe symptoms as well as airflow limitation, and benefit less from treatment with inhaled corticosteroids (ICS) compared with non-smoking asthmatics [1]. Additionally, smoking is associated with small airways dysfunction (SAD) [2]. The small airways, defined by a diameter ≤ 2 mm contribute to the resistance in the airways of patients with obstructive airways disease [3]. This has a clinical impact since small airways can be inflamed in asthma and hence narrowed [4]. We hypothesized that smokers and ex-smokers with asthma would benefit more from extrafine than non-extrafine particle ICS. However, our OLiVIA-study showed that extrafine and non-extrafine particle ICS were equally effective in improving small airways function in current and ex-smokers with asthma [5]. This outcome might be ascribed to the fact that the presence of SAD was not an inclusion criterion in our study. Therefore, we performed a post-hoc analysis to investigate whether current and ex-smoking asthmatics with SAD show a better clinical response to extrafine compared to non-extrafine particle ICS. Next, we investigated which clinical parameters, apart from the presence of SAD, predict a favorable response to extrafine and non-extrafine particle ICS.
The OLiVIA-study was an open-label, randomized, three-way crossover, two-center study, comparing two-week treatment with extrafine hydrofluoroalkane (HFA)-beclomethasone 200 μg b.i.d. (QVAR) to non-extrafine HFA-beclomethasone 400 μg b.i.d. (Clenil) and non-extrafine HFA-fluticasone 250 μg b.i.d. (Flixotide) [5]. The primary outcome was the change in airway hyperresponsiveness (AHR) to small particle adenosine, expressed as the provocative dose of adenosine causing a 20% drop in FEV1 (forced expiratory volume at 1 s) from baseline to post-treatment (ΔPD20). Small particle adenosine is a provocative agent that acts indirectly via the release of mediators from inflammatory cells. It was chosen rather than methacholine as it is a more sensitive measurement to detect improvement in AHR after treatment with ICS in patients with asthma [6].
Since there is no clearly defined golden standard for SAD, we applied various parameters next to the PD20 adenosine, i.e. parameters of spirometry, body plethysmography, impulse oscillometry (IOS) and multiple breath nitrogen washout (MBNW). We used cut-off values for SAD parameters as follows: forced expiratory flow between 25 and 75% of forced vital capacity [FEF25–75] < lower limit of normal (LLN) from spirometry; ratio of residual volume to total lung capacity [RV/TLC] > upper limit of normal (ULN) from body plethysmography; difference between resistance at 5 Hz and 20 Hz [R5-R20] > 0.1 kPa sL− 1 from IOS [7]; and ventilation heterogeneity of the acinar structures [Sacin] and conductive airways [Scond] > ULN from MBNW [8]. These measurements were taken at the baseline visit after an ICS washout period of four to six weeks. The presence of SAD was defined as: at least 3 out of 5 criteria fulfilled when all lung function measurements were performed, or with 2 out of 3 criteria if MBNW was not carried out, which was the case in 8 patients.
We performed a two-sided paired t-test or Wilcoxon test to assess the difference in ΔPD20 adenosine after treatment with extrafine compared to non-extrafine particle ICS in patients with SAD and patients without SAD. PD20 values were log2-transformed prior to analyses. To investigate the difference in ΔPD20 between patients with SAD and without SAD within one treatment group, we performed a student t-test or Mann-Whitney test. Next, we explored which baseline variables (i.e. demographics, small and large function measures, presence of atopy and blood leukocyte counts) were associated with ΔPD20 adenosine after extrafine and non-extrafine particle ICS treatment using univariate linear regression analysis. We finally performed multivariate linear regression analyses for each treatment type to identify independent clinical predictors for ΔPD20 including age, sex, smoking status, numbers of neutrophils and eosinophils, and completed with those variables showing a trend towards association with ΔPD20 (p < 0.1) in the univariate analysis. We allowed a maximum of 7 variables to be included in the multivariate model. The variables in this final model were selected based on the following criteria: (1) the variable changed regression coefficients (B) > 10%, (2) the model had highest total explained variance (R2), and (3) the model preferably included the highest number of subjects.
We analyzed 43 asthma patients (22 smokers and 21 ex-smokers), 42% being male, with mean (standard deviation (SD)) age 45 (12.6) years, FEV1 83 (14.5) % predicted, and PD20 2.69 (3.41) mg. Baseline characteristics of the study population are presented in Additional file 1: Table S1. At baseline, we found that SAD was present in 18 (42%) patients (see Additional file 1: Table S2). Asthma patients with and without SAD had similar response in PD20 adenosine to extrafine (QVAR) and non-extrafine particle ICS treatments (Clenil and Flixotide) (Fig. 1; and Additional file 1: Table S3).
Results of the univariate linear regression analyses are presented in Additional file 1: Table S4. Multivariate linear regression analyses (Table 1) showed that no parameters of SAD were associated with treatment response to either small or large particle ICS. Lower numbers of blood neutrophils were associated with a larger increase in PD20 adenosine, independently from the level of blood eosinophils, in patients treated with QVAR, Clenil and Flixotide (all p < 0.05). Higher blood eosinophils were also associated with a larger increase in PD20 adenosine in patients treated with Flixotide (p < 0.05). Finally, younger age tended to be associated with a larger increase in PD20 adenosine after using Clenil (p = 0.05).
Table 1
Multivariate linear regression analysis of baseline variables with change in airway hyperresponsiveness to small particle adenosine (ΔPD20) as dependent variable in patients treated with QVAR, Clenil and Flixotide
 
Baseline predictors
B
95% CI
p-value
R2
ΔPD20 QVAR
Age, years
−0.10
− 0.06; 0.04
0.703
0.64
Sex, male/ female
0.41
−0.78; 1.60
0.485
Current smoking, yes/no
−0.47
−1.87; 0.93
0.493
Blood neutrophils, 109/L
−0.55
−1.00; − 0.09
0.020
Blood eosinophils, 109/L
2.81
−0.48; 6.09
0.090
FEV1, % predicted
0.04
−0.01; 0.09
0.090
LCI at 2.5%
−0.30
− 0.69; 0.08
0.117
ΔPD20 Clenil
Age, years
−0.06
− 0.12; 0.00
0.050
0.48
Sex, male/ female
0.80
−0.42; 2.03
0.192
Current smoking, yes/no
−0.95
−2.33; 0.43
0.170
Blood neutrophils, 109/L
−0.61
−1.04; − 0.18
0.006
Blood eosinophils, 109/L
3.04
−0.06; 6.15
0.054
FEV1, % predicted
0.03
−0.01; 0.07
0.180
ΔPD20 Flixotide
Age, years
−0.03
−0.08; 0.02
0.181
0.60
Sex, male/ female
0.85
−0.25; 1.96
0.125
Current smoking, yes/no
−0.33
−1.51; 0.85
0.573
Blood neutrophils, 109/L
−0.78
−1.13; −0.43
0.000
Blood eosinophils, 109/L
3.53
0.88; 6.17
0.011
FEV1, % predicted
0.002
−0.04; 0.04
0.937
RV/TLC, % predicted
−0.03
−0.06; 0.004
0.089
B: regression coefficients; CI: Confidence Intervals; R2: total explained variance; ΔPD20: the change from baseline to post-treatment in the provocative dose of small particle adenosine causing a 20% drop in FEV1; FEV1: forced expiratory volume in 1 s; LCI: lung clearance index; and RV/TLC: the ratio of residual volume to total lung capacity
We did not confirm our hypothesis that current and ex-smoking asthmatics with SAD had a better treatment response to QVAR compared to Clenil and Flixotide. In line with previous reports on better clinical effects of ICS in asthmatics with eosinophilia [911], we show that higher blood eosinophils are associated with a less severe AHR after treatment with non-extrafine particle ICS (Flixotide). Of interest, our study shows that higher blood neutrophils are associated with more severe AHR after treatment with both extrafine and non-extrafine particle ICS in smokers and ex-smokers with asthma, independently from the level of blood eosinophils. Findings by Telenga et al. support that lower blood neutrophils are associated with an increase in FEV1 after 2-week ICS-therapy [11]. Taken together, we find that higher blood neutrophils are associated with less clinical ICS-response in smokers and ex-smokers with asthma. However, our data (Additional file 1: Figure S1) do not clearly show a cut-off value for eosinophilia or neutrophilia that can be used in clinical practice to define a positive response. Future studies have to assess whether this change in inflammation in peripheral blood is reflected by changes in the small and larger airways.
A strength of the study is that we defined SAD by cut-off levels applying multiple measurement techniques including spirometry, body plethysmography, impulse oscillometry and multiple breath nitrogen washout. A limitation is the relatively small sample size of patients with SAD and non-SAD which limits the power of the study and raises the risk of type I error. However, a post-hoc power analysis indicated that we had a sufficient number of patients to detect a difference of one doubling dose increase in PD20 adenosine between patients with and without SAD. With a standard deviation of one doubling dose, β = 0.8 and α = 0.05, we would need 16 patients per group while in our study, 18 patients with and 23 patients without SAD were investigated. Further studies with larger sample sizes would provide a clearer picture of SAD in smokers and ex-smokers with asthma. Another possible limitation is that we treated for two weeks which may have been too short to improve SAD.
In conclusion, we show that smoking and ex-smoking asthmatics with and without SAD have a similar response to small particle adenosine after treatment with either extrafine or non-extrafine particle ICS. These findings suggest that clinicians may not need to consider SAD in order to decide whether current- and ex-smoking asthmatics would benefit preferentially from treatment with extrafine rather than non-extrafine particle ICS. Of importance, we find that lower blood neutrophils is a favorable predictor of ICS response, independent from the level of blood eosinophils.

Acknowledgements

We would like to thank all patients for their participation in the study.

Funding

This study was supported by TEVA pharmaceutical Industries Ltd., which was in no way involved in study design, writing or reviewing of the manuscript.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Author contributions

DSP and MvdB designed the study. IMB and CAC performed data collection. FG performed data analysis under supervision of DSP, MvdB and IMB. FG, MvdB, DSP, IMB and CAC interpreted the data. FG drafted the manuscript under supervision of IMB, DSP and MvdB. JMV advised and revised the statistical analysis. IMB, CAC, JMV, SS, AJL, HWF, PH, DSP and MvdB have full access to study data and are accountable for all aspects of the work. DSP, IMB and MvdB supervised the entire project. All authors critically revised for important intellectual content and approved the final version of the manuscript.
The initial OLIVIA-study was approved by the ethical committee of the University Medical Center Groningen, and registered on ClinicalTrials.​gov (NCT01741285).
Not applicable.

Competing interests

The University of Groningen received fees for consultancy for IMB from GlaxoSmithKline. Based on a patent of the Genuair of which PH and HWF are co-inventors, the University of Groningen received royalty payments from Astra Zeneca. PH received fees paid to the University of Groningen for patent of the Novolizer, Twincer and Cyclops and his employer receives royalties from the sales of the Novolizer and Genuair. DSP has received research grants from GlaxoSmithKline, fees for consultancies from Chiesi and Astra Zeneca, and speaker’s fees from Chiesi, all of which paid to the University of Groningen. MvdB has received grants paid to the University of Groningen from GlaxoSmithKline, Chiesi and TEVA Pharma. FG, CAC, JMV, AJL and SS do not have any conflict of interest to declare.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Thomson NC, Spears M. The influence of smoking on the treatment response in patients with asthma. Curr Opin Allergy Clin Immunol. 2005;5(1):57–63.CrossRef Thomson NC, Spears M. The influence of smoking on the treatment response in patients with asthma. Curr Opin Allergy Clin Immunol. 2005;5(1):57–63.CrossRef
2.
Zurück zum Zitat Verbanck S, Schuermans D, Meysman M, Paiva M, Vincken W. Noninvasive assessment of airway alterations in smokers: the small airways revisited. Am J Respir Crit Care Med. 2004;170(4):414–9.CrossRef Verbanck S, Schuermans D, Meysman M, Paiva M, Vincken W. Noninvasive assessment of airway alterations in smokers: the small airways revisited. Am J Respir Crit Care Med. 2004;170(4):414–9.CrossRef
3.
Zurück zum Zitat van der Wiel E, ten Hacken NH, Postma DS, van den Berge M. Small-airways dysfunction associates with respiratory symptoms and clinical features of asthma: a systematic review. J Allergy Clin Immunol. 2013;131(3):646–57.CrossRef van der Wiel E, ten Hacken NH, Postma DS, van den Berge M. Small-airways dysfunction associates with respiratory symptoms and clinical features of asthma: a systematic review. J Allergy Clin Immunol. 2013;131(3):646–57.CrossRef
4.
Zurück zum Zitat Kraft M, Pak J, Martin RJ, Kaminsky D, Irvin CG. Distal lung dysfunction at night in nocturnal asthma. Am J Respir Crit Care Med. 2001;163:1551–6.CrossRef Kraft M, Pak J, Martin RJ, Kaminsky D, Irvin CG. Distal lung dysfunction at night in nocturnal asthma. Am J Respir Crit Care Med. 2001;163:1551–6.CrossRef
5.
Zurück zum Zitat Cox CA, Boudewijn IM, Vroegop SJ, Schokker S, Lexmond AJ, Frijlink HW, et al. Extrafine compared to non-extrafine particle inhaled corticosteroids in smokers and ex-smokers with asthma. Respir Med. 2017;130:35–42.CrossRef Cox CA, Boudewijn IM, Vroegop SJ, Schokker S, Lexmond AJ, Frijlink HW, et al. Extrafine compared to non-extrafine particle inhaled corticosteroids in smokers and ex-smokers with asthma. Respir Med. 2017;130:35–42.CrossRef
6.
Zurück zum Zitat van den Berge M, Meijer RJ, Kerstjens HA, de Reus DM, Koeter GH, Kauffman HF, et al. PC(20) adenosine 5′-monophosphate is more closely associated with airway inflammation in asthma than PC(20) methacholine. Am J Respir Crit Care Med. 2001;163(7):1546–50.CrossRef van den Berge M, Meijer RJ, Kerstjens HA, de Reus DM, Koeter GH, Kauffman HF, et al. PC(20) adenosine 5′-monophosphate is more closely associated with airway inflammation in asthma than PC(20) methacholine. Am J Respir Crit Care Med. 2001;163(7):1546–50.CrossRef
7.
Zurück zum Zitat Manoharan A, Anderson WJ, Lipworth J, Lipworth BJ. Assessment of spirometry and impulse oscillometry in relation to asthma control. Lung. 2015;193(1):47–51.CrossRef Manoharan A, Anderson WJ, Lipworth J, Lipworth BJ. Assessment of spirometry and impulse oscillometry in relation to asthma control. Lung. 2015;193(1):47–51.CrossRef
8.
Zurück zum Zitat Verbanck S, Thompson BR, Schuermans D, Kalsi H, Biddiscombe M, Stuart-Andrews C, et al. Ventilation heterogeneity in the acinar and conductive zones of the normal ageing lung. Thorax. 2012;67(9):789–95.CrossRef Verbanck S, Thompson BR, Schuermans D, Kalsi H, Biddiscombe M, Stuart-Andrews C, et al. Ventilation heterogeneity in the acinar and conductive zones of the normal ageing lung. Thorax. 2012;67(9):789–95.CrossRef
9.
Zurück zum Zitat Szefler SJ, Martin RJ, King TS, Boushey HA, Cherniack RM, Chinchilli VM, et al. Significant variability in response to inhaled corticosteroids for persistent asthma. J Allergy Clin Immunol. 2002;109(3):410–8.CrossRef Szefler SJ, Martin RJ, King TS, Boushey HA, Cherniack RM, Chinchilli VM, et al. Significant variability in response to inhaled corticosteroids for persistent asthma. J Allergy Clin Immunol. 2002;109(3):410–8.CrossRef
10.
Zurück zum Zitat Meijer RJ, Postma DS, Kauffman HF, Arends LR, Koeter GH, Kerstjens HA. Accuracy of eosinophils and eosinophil cationic protein to predict steroid improvement in asthma. Clin Exp Allergy. 2002;32:1096–103.CrossRef Meijer RJ, Postma DS, Kauffman HF, Arends LR, Koeter GH, Kerstjens HA. Accuracy of eosinophils and eosinophil cationic protein to predict steroid improvement in asthma. Clin Exp Allergy. 2002;32:1096–103.CrossRef
11.
Zurück zum Zitat Telenga ED, Kerstjens HA, Ten Hacken NH, Postma DS, van den Berge M. Inflammation and corticosteroid responsiveness in ex-, current- and never-smoking asthmatics. BMC Pulm Med. 2013;13:58.CrossRef Telenga ED, Kerstjens HA, Ten Hacken NH, Postma DS, van den Berge M. Inflammation and corticosteroid responsiveness in ex-, current- and never-smoking asthmatics. BMC Pulm Med. 2013;13:58.CrossRef
Metadaten
Titel
Predictors of clinical response to extrafine and non-extrafine particle inhaled corticosteroids in smokers and ex-smokers with asthma
verfasst von
Fajri Gafar
Ilse M. Boudewijn
Claire A. Cox
Judith M. Vonk
Siebrig Schokker
Anne J. Lexmond
Henderik W. Frijlink
Paul Hagedoorn
Dirkje S. Postma
Maarten van den Berge
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
Respiratory Research / Ausgabe 1/2018
Elektronische ISSN: 1465-993X
DOI
https://doi.org/10.1186/s12931-018-0961-2

Weitere Artikel der Ausgabe 1/2018

Respiratory Research 1/2018 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.