Skip to main content
Erschienen in: The Journal of Obstetrics and Gynecology of India 5/2016

15.03.2015 | Original Article

Pregnancy Outcome in Women with Mechanical Prosthetic Heart Valves Treated with Unfractionated Heparin (UFH) or Enoxaparin

verfasst von: Khalid Abd Aziz Mohamad Khader, Ahmed Samy Saad, Mohammed Abdelshafy

Erschienen in: The Journal of Obstetrics and Gynecology of India | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

Objective

This study was carried out to determine the maternal (including thromboembolic and hemorrhagic complications) and fetal outcomes (including miscarriage, stillbirth, baby death, and live birth) in women with mechanical heart valves managed with therapeutic doses of unfractionated heparin (UFH) versus enoxaparin during pregnancy.

Methods

This is a prospective comparative, nonrandomized study. Pregnant women with mechanical heart valves presenting to high-risk pregnancy unit of Benha University Hospital, Egypt were treated with UFH 15,000 U/12 h versus enoxaparin (Clexane) 1 mg/kg SC/12 h during pregnancy and the results were analyzed.

Results

40 pregnant women were included in the study. In 20 pregnant women, anticoagulation was with UFH, and 20 pregnant women received enoxaparin. One (3 %) thrombotic complication occurred with enoxaparin treatment. Noncompliance or subtherapeutic levels contributed to this outcome in this case. Antenatal hemorrhage occurred in 4 (10 %) and postpartum hemorrhagic complications in 5 (12.5 %) pregnancies. Of the 32 pregnant women who continued after 20 weeks’ gestation, 100 % (17/17) of the women taking predominantly UFH had a surviving infant compared with 93 % (14/15) of the women taking primarily enoxaparin (p = 0.25). One intrauterine fetal death occurred in the enoxaparin group. There was no significant difference in the live birth rates between the two groups (p = 0.31).

Conclusions

Compliance with therapeutic dose of UFH during pregnancy in women with mechanical heart valves is associated with a low risk of valve thrombosis and good fetal outcomes, but meticulous monitoring is essential.
Literatur
1.
Zurück zum Zitat Elkayam U, Bitar F. Valvular heart disease and pregnancy: part II: prosthetic valves. J Am Coll Cardiol. 2005;46:403–10.CrossRefPubMed Elkayam U, Bitar F. Valvular heart disease and pregnancy: part II: prosthetic valves. J Am Coll Cardiol. 2005;46:403–10.CrossRefPubMed
2.
Zurück zum Zitat Chan WS, Anand S, Ginsberg JS. Anticoagulation of pregnant women with mechanical heart valves: a systematic review of the literature. Arch Intern Med. 2000;160:191–6.CrossRefPubMed Chan WS, Anand S, Ginsberg JS. Anticoagulation of pregnant women with mechanical heart valves: a systematic review of the literature. Arch Intern Med. 2000;160:191–6.CrossRefPubMed
3.
4.
Zurück zum Zitat Hall JG, Pauli RM, Wilson KM. Maternal and fetal sequelae of anticoagulation during pregnancy. Am J Med. 1980;68:122–40.CrossRefPubMed Hall JG, Pauli RM, Wilson KM. Maternal and fetal sequelae of anticoagulation during pregnancy. Am J Med. 1980;68:122–40.CrossRefPubMed
5.
Zurück zum Zitat Briggs GB, Bodendorfer JW, Freeman RK, et al., editors. Drugs in pregnancy and lactation. Baltimore: Williams and Wilkins; 1994. Briggs GB, Bodendorfer JW, Freeman RK, et al., editors. Drugs in pregnancy and lactation. Baltimore: Williams and Wilkins; 1994.
6.
Zurück zum Zitat Rowan JA, McLintock C, Taylor RS, et al. Prophylactic and therapeutic enoxaparin during pregnancy: indications, outcomes and monitoring. Aust N Z J Obstet Gynaecol. 2003;43(2):123–8.CrossRefPubMed Rowan JA, McLintock C, Taylor RS, et al. Prophylactic and therapeutic enoxaparin during pregnancy: indications, outcomes and monitoring. Aust N Z J Obstet Gynaecol. 2003;43(2):123–8.CrossRefPubMed
7.
Zurück zum Zitat Huxtable LM, Tafreshi MJ, Ondreyco SM. A protocol for the use of enoxaparin during pregnancy: results from 85 pregnancies including 13 multiple gestation pregnancies. Clin Appl Thromb Hemost. 2005;11(2):171–81.CrossRefPubMed Huxtable LM, Tafreshi MJ, Ondreyco SM. A protocol for the use of enoxaparin during pregnancy: results from 85 pregnancies including 13 multiple gestation pregnancies. Clin Appl Thromb Hemost. 2005;11(2):171–81.CrossRefPubMed
8.
Zurück zum Zitat Oran B, Lee-Parritz A, Ansell J. Low molecular weight heparin for the prophylaxis of thromboembolism in women with prosthetic mechanical heart valves during pregnancy. Thromb Haemost. 2004;92(4):747–51.PubMed Oran B, Lee-Parritz A, Ansell J. Low molecular weight heparin for the prophylaxis of thromboembolism in women with prosthetic mechanical heart valves during pregnancy. Thromb Haemost. 2004;92(4):747–51.PubMed
9.
Zurück zum Zitat Maslovitz S, Many A, Landsberg JA, et al. The safety of low molecular weight heparin therapy during labor. Matern Fetal Neonatal Med. 2005;17(1):39–43.CrossRef Maslovitz S, Many A, Landsberg JA, et al. The safety of low molecular weight heparin therapy during labor. Matern Fetal Neonatal Med. 2005;17(1):39–43.CrossRef
10.
Zurück zum Zitat Bates Shannon M, Greer Ian A, Pabinger Ingrid, et al. Use of thrombotic agents during pregnancy: the eighth ACCP conference on antithrombotic and thrombolytic therapy. Chest. 2008;133(6):844S–86S.CrossRefPubMed Bates Shannon M, Greer Ian A, Pabinger Ingrid, et al. Use of thrombotic agents during pregnancy: the eighth ACCP conference on antithrombotic and thrombolytic therapy. Chest. 2008;133(6):844S–86S.CrossRefPubMed
11.
Zurück zum Zitat Danik S, Fuster V. Anticoagulation pregnant women with prosthetic heart valves. Mt Sinai J Med. 2004;71(5):322–9.PubMed Danik S, Fuster V. Anticoagulation pregnant women with prosthetic heart valves. Mt Sinai J Med. 2004;71(5):322–9.PubMed
12.
Zurück zum Zitat Kawamata K, Neki R, Yamanaka K, et al. Risks and pregnancy out come in women with prosthetic mechanical heart valve replacement. Circ J. 2007;71(2):211–3.CrossRefPubMed Kawamata K, Neki R, Yamanaka K, et al. Risks and pregnancy out come in women with prosthetic mechanical heart valve replacement. Circ J. 2007;71(2):211–3.CrossRefPubMed
13.
Zurück zum Zitat Born D, Martinez EE, Almeida PA, et al. Pregnancy in patients with prosthetic heart valves: the effects of anticoagulation on mother, fetus, and neonate. Am Heart J. 1992;124(2):413–7.CrossRefPubMed Born D, Martinez EE, Almeida PA, et al. Pregnancy in patients with prosthetic heart valves: the effects of anticoagulation on mother, fetus, and neonate. Am Heart J. 1992;124(2):413–7.CrossRefPubMed
15.
Zurück zum Zitat Bonow RO, Carabello BA, Chatterjee K, et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease. J Am Coll Cardiol. 2006;48:140–8.CrossRef Bonow RO, Carabello BA, Chatterjee K, et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease. J Am Coll Cardiol. 2006;48:140–8.CrossRef
16.
Zurück zum Zitat Hung L, Rahimtoola SH. Prosthetic heart valves and pregnancy. Circulation. 2003;107:1240–6.CrossRefPubMed Hung L, Rahimtoola SH. Prosthetic heart valves and pregnancy. Circulation. 2003;107:1240–6.CrossRefPubMed
17.
Zurück zum Zitat Nassar AH, Hobeika EM, Essamad HMA. Pregnancy outcome in women with prosthetic heart valves. Am J Obstet Gynecol. 2004;191(3):1009–13.CrossRefPubMed Nassar AH, Hobeika EM, Essamad HMA. Pregnancy outcome in women with prosthetic heart valves. Am J Obstet Gynecol. 2004;191(3):1009–13.CrossRefPubMed
18.
Zurück zum Zitat Geelani MA, Singh S, Verma A, et al. Anticoagulation in patients with mechanical valves during pregnancy. Asian Cardiovasc Thorac Ann. 2005;13(1):30–3.CrossRefPubMed Geelani MA, Singh S, Verma A, et al. Anticoagulation in patients with mechanical valves during pregnancy. Asian Cardiovasc Thorac Ann. 2005;13(1):30–3.CrossRefPubMed
19.
Zurück zum Zitat Cotrufo M, De Feo M, De Santo LS, et al. Risk of warfarin during pregnancy with mechanical valve prostheses. Obstet Gynecol. 2002;99(1):35–40.PubMed Cotrufo M, De Feo M, De Santo LS, et al. Risk of warfarin during pregnancy with mechanical valve prostheses. Obstet Gynecol. 2002;99(1):35–40.PubMed
20.
Zurück zum Zitat Al-Lawati AA, Venkitraman M, Al-Delaime T, et al. Pregnancy and mechanical heart valves replacement; dilemma of anticoagulation. Eur J Cardiothorac Surg. 2002;22(2):223–7.CrossRefPubMed Al-Lawati AA, Venkitraman M, Al-Delaime T, et al. Pregnancy and mechanical heart valves replacement; dilemma of anticoagulation. Eur J Cardiothorac Surg. 2002;22(2):223–7.CrossRefPubMed
21.
Zurück zum Zitat Akhtar RP, Abid AR, Zafar H, et al. Anticoagulation in pregnancy with mechanical heart valves: 10-year experience. Asian Cardiovasc Thorac Ann. 2007;15(6):497–501.CrossRefPubMed Akhtar RP, Abid AR, Zafar H, et al. Anticoagulation in pregnancy with mechanical heart valves: 10-year experience. Asian Cardiovasc Thorac Ann. 2007;15(6):497–501.CrossRefPubMed
22.
Zurück zum Zitat Salazar E, Izaguirre R, Verdejo J, et al. Failure of adjusted doses of subcutaneous heparin to prevent thromboembolic phenomena in pregnant patients with mechanical cardiac valve prostheses. J Am Coll Cardiol. 1996;27(7):1698–703.CrossRefPubMed Salazar E, Izaguirre R, Verdejo J, et al. Failure of adjusted doses of subcutaneous heparin to prevent thromboembolic phenomena in pregnant patients with mechanical cardiac valve prostheses. J Am Coll Cardiol. 1996;27(7):1698–703.CrossRefPubMed
23.
Zurück zum Zitat James AH, Brancazio LR, Gehrig TR. Low-molecular-weight heparin for thromboprophylaxis in pregnant women with mechanical heart valves. J Matern Fetal Neonatal Med. 2006;19:543–9.CrossRefPubMed James AH, Brancazio LR, Gehrig TR. Low-molecular-weight heparin for thromboprophylaxis in pregnant women with mechanical heart valves. J Matern Fetal Neonatal Med. 2006;19:543–9.CrossRefPubMed
24.
Zurück zum Zitat Rowan JA, McCowan LM, Raudkivi PJ, et al. Enoxaparin treatment in women with mechanical heart valves during pregnancy. Am J Obstet Gynecol. 2001;185:633–7.CrossRefPubMed Rowan JA, McCowan LM, Raudkivi PJ, et al. Enoxaparin treatment in women with mechanical heart valves during pregnancy. Am J Obstet Gynecol. 2001;185:633–7.CrossRefPubMed
25.
Zurück zum Zitat Kim KH, Jeong DS, Ahn H. Anticoagulation in pregnant women with a bileaflet mechanical cardiac valve replacement. Heart Surg Forum. 2007;10(4):E 267–27007;71(2):211–3. Kim KH, Jeong DS, Ahn H. Anticoagulation in pregnant women with a bileaflet mechanical cardiac valve replacement. Heart Surg Forum. 2007;10(4):E 267–27007;71(2):211–3.
Metadaten
Titel
Pregnancy Outcome in Women with Mechanical Prosthetic Heart Valves Treated with Unfractionated Heparin (UFH) or Enoxaparin
verfasst von
Khalid Abd Aziz Mohamad Khader
Ahmed Samy Saad
Mohammed Abdelshafy
Publikationsdatum
15.03.2015
Verlag
Springer India
Erschienen in
The Journal of Obstetrics and Gynecology of India / Ausgabe 5/2016
Print ISSN: 0971-9202
Elektronische ISSN: 0975-6434
DOI
https://doi.org/10.1007/s13224-015-0678-9

Weitere Artikel der Ausgabe 5/2016

The Journal of Obstetrics and Gynecology of India 5/2016 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.