Abstract

This study was designed to verify whether preheating could decrease the complications that may be associated with the use of streamlined liner of pharyngeal airway (SLIPA). We evaluated the incidence of sore throat, maximum sealing pressure, hoarseness and blood stains after preheating of SLIPA. Eighty patients scheduled for hysteroscopic surgery to whom the SLIPA was considered suitable were randomly allocated to preheating group or control group. The SLIPA in preheating group was placed in the incubator at 42 °C. The control group temperature was 24 °C. The mean maximum sealing pressure and duration of insertion were compared. Patients were interviewed at recovery room about sore throat and other complications. There were statistical differences in incidence of sore throat, severity of sore throat and blood stains between groups. However there was no statistical difference in the maximum sealing pressure. Our results suggest preheating of the SLIPA decreased the complications related with the insertion of SLIPA.
Clinical Trials.gov Identifier NCT02539485.
Literatur
1.
Zurück zum Zitat Robak O, Leonardelli M, Zedtwitz-Liebenstein K, Rützler K, Schuster E, Vaida S, et al. Feasibility and speed of insertion of seven supraglottic airway devices under simulated airway conditions. Can J Emerg Med. 2012;14:330–4. Robak O, Leonardelli M, Zedtwitz-Liebenstein K, Rützler K, Schuster E, Vaida S, et al. Feasibility and speed of insertion of seven supraglottic airway devices under simulated airway conditions. Can J Emerg Med. 2012;14:330–4.
2.
Zurück zum Zitat Timmermann A. Supraglottic airways in difficult airway management: successes, failures, use and misuse. Anesthesia. 2011;66(Suppl 2):45–56.CrossRef Timmermann A. Supraglottic airways in difficult airway management: successes, failures, use and misuse. Anesthesia. 2011;66(Suppl 2):45–56.CrossRef
3.
Zurück zum Zitat Woo YC, Cha SM, Kang H, Baek CW, Jung YH, Kim JY, et al. Less perilaryngeal gas leakage with SLIPATM than with LMA-ProSealTM in paralyzed patients. Can J Anaesth. 2011;58:48–54.CrossRefPubMed Woo YC, Cha SM, Kang H, Baek CW, Jung YH, Kim JY, et al. Less perilaryngeal gas leakage with SLIPATM than with LMA-ProSealTM in paralyzed patients. Can J Anaesth. 2011;58:48–54.CrossRefPubMed
4.
Zurück zum Zitat Abdellatif AA, Ali MA. Comparison of streamlined liner of the pharynx airway (SLIPATM) with the laryngeal mask airway ProsealTM for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients. Saudi J Anaesth. 2011;5:270–6.CrossRefPubMedPubMedCentral Abdellatif AA, Ali MA. Comparison of streamlined liner of the pharynx airway (SLIPATM) with the laryngeal mask airway ProsealTM for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients. Saudi J Anaesth. 2011;5:270–6.CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Choi YM, Cha SM, Kang H, Baek CW, Jung YH, Woo YC, et al. The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA) compared with the laryngeal mask airway ProSeal during general anesthesia. Korean J Anesthesiol. 2010;58:450–7.CrossRefPubMedPubMedCentral Choi YM, Cha SM, Kang H, Baek CW, Jung YH, Woo YC, et al. The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA) compared with the laryngeal mask airway ProSeal during general anesthesia. Korean J Anesthesiol. 2010;58:450–7.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Markus L, Franz K. The effectiveness and patient comfort of the novel streamlined pharynx airway liner (SLIPA) compared with the conventional laryngeal mask airway in ophthalmic surgery. Anesth Analg. 2007;104:431–4.CrossRef Markus L, Franz K. The effectiveness and patient comfort of the novel streamlined pharynx airway liner (SLIPA) compared with the conventional laryngeal mask airway in ophthalmic surgery. Anesth Analg. 2007;104:431–4.CrossRef
7.
Zurück zum Zitat Miller DM, Camporota L. Advantages of ProSeal and SLIPA airways over tracheal tubes for gynecological laparoscopies. Can J Anaesth. 2006;53:188–93.CrossRefPubMed Miller DM, Camporota L. Advantages of ProSeal and SLIPA airways over tracheal tubes for gynecological laparoscopies. Can J Anaesth. 2006;53:188–93.CrossRefPubMed
8.
Zurück zum Zitat Miller DM, Light D. Laboratory and clinical comparisons of the streamlined liner of the pharynx airway (SLIPA™) with the laryngeal mask airway. Anaesthesia. 2003;58:136–42.CrossRefPubMed Miller DM, Light D. Laboratory and clinical comparisons of the streamlined liner of the pharynx airway (SLIPA™) with the laryngeal mask airway. Anaesthesia. 2003;58:136–42.CrossRefPubMed
9.
Zurück zum Zitat Ahn EJ, Kang H, Choi GJ, Yang SY, Shin HY, Baek CW, et al. Streamlined liner of the pharynx airway: randomized comparison of size selection strategies with regard to patient height vs. thyroid cartilage width. Hong Kong J Emerg Med. 2015;22:303–11. Ahn EJ, Kang H, Choi GJ, Yang SY, Shin HY, Baek CW, et al. Streamlined liner of the pharynx airway: randomized comparison of size selection strategies with regard to patient height vs. thyroid cartilage width. Hong Kong J Emerg Med. 2015;22:303–11.
10.
Zurück zum Zitat Kang H, Kim DR, Jung YH, et al. Pre-warming the streamlined liner of the pharynx airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study. Int Anesth Res Soc BMC Anesthesiol. 2015;15:167–73. Kang H, Kim DR, Jung YH, et al. Pre-warming the streamlined liner of the pharynx airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study. Int Anesth Res Soc BMC Anesthesiol. 2015;15:167–73.
11.
Zurück zum Zitat Puri GD, Hegde HV, Jayant A, Bhukal I. Haemodynamic and bispectral index response to insertion of the streamlined liner of the pharynx airway (SLIPA): comparison with the laryngeal mask airway. Anaesth Intensive Care. 2008;36:404–10.PubMed Puri GD, Hegde HV, Jayant A, Bhukal I. Haemodynamic and bispectral index response to insertion of the streamlined liner of the pharynx airway (SLIPA): comparison with the laryngeal mask airway. Anaesth Intensive Care. 2008;36:404–10.PubMed
12.
Zurück zum Zitat Weiler N, Latorre F, Eberle B, Goedecke R, Heinrichs W. Respiratory mechanics, gastric insufflation pressure and air leakage of the laryngeal mask airway. Anesth Analg. 1997;84:1025–8.CrossRefPubMed Weiler N, Latorre F, Eberle B, Goedecke R, Heinrichs W. Respiratory mechanics, gastric insufflation pressure and air leakage of the laryngeal mask airway. Anesth Analg. 1997;84:1025–8.CrossRefPubMed
Metadaten
Titel
Preheating of streamlined liner of pharyngeal airway (SLIPA) reduced the related complications: a randomized control study
verfasst von
Guiqi Geng
Yingjie Chen
Hailian Liu
Publikationsdatum
08.04.2016
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 3/2017
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-016-9875-z

Weitere Artikel der Ausgabe 3/2017

Journal of Clinical Monitoring and Computing 3/2017 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.