Ultraschall Med 2011; 32: E141-E146
DOI: 10.1055/s-0031-1281669
Original Article

© Georg Thieme Verlag KG Stuttgart · New York

Continuous Independent Quality Control for Fetal Nuchal Translucency Measurements Provided by the Cumulative Summation Technique

Kontinuierliche unabhängige Qualitätskontrolle der fetalen Nackentransparenzmessungen durch kumulative SummentechnikD. Balsyte1 , L. Schäffer1 , T. Burkhardt1 , J. Wisser1 , A. Krafft1 , J. Kurmanavicius1
  • 1Frauenheilkunde, UniversitätsSpital Zürich
Further Information

Publication History

received: 31.1.2011

accepted: 18.7.2011

Publication Date:
29 August 2011 (online)

Zusammenfassung

Ziel: Die kumulative Summentechnik (CUSUM) ist eine innovative Methode zur Qualitätskontrolle der Nackentransparenzbestimmungen (NT-Bestimmung). CUSUM bietet die Möglichkeit eines direkten korrigierenden Eingriffs sobald eine nicht akzeptierbare Tendenz bemerkt wird. Das Ziel dieser Studie war die Einführung einer auf der CUSUM-Technik basierenden objektiven und dynamischen Kontrollmethode zur schnellen Analyse von fetalen NT-Bestimmungen, die auf die unterschiedlichen Standards in der klinischen Routinepraxis abgestimmt ist. Die Ergebnisse wurden mit den derzeit gebräuchlichen Standard-NT-Qualitätskontrollmethoden verglichen. Material und Methoden: Für die retrospektive Auswertung wurden drei fetale NT-Messreihen ausgewählt, die von drei erfahrenen Untersuchern (I, II und III) durchgeführt wurden. Ein zusätzliche NT-Messreihe durchgeführt von Untersucher IV wurde prospektiv bewertet, um der Praktikabilität der Methode zuzustimmen. Die NT-Messungen wurden gemäß den Empfehlungen der FMF Deutschland und London ausgeführt. Die NT-Werte wurden in Z-Faktoren umgewandelt. Zur Qualitäts- und Genauigkeitsbewertung wurden die Daten in die Digisono CUSUM Software eingespeichert, um doppelte CUSUM-Diagramme der Z-Faktoren zu gewinnen. Darüber hinaus wurden Histogramme der Z-Faktoren aus jeder Messreihe erstellt und gegen die Gaußsche Normalverteilung aufgetragen. Ergebnisse: Drei verschiedene Muster der retrospektiven Durchführung und eine prospektiv bewertete NT-Messreihe werden vorgestellt. Die vollständige Angleichung der Z-Faktoren mittels CUSUM-Kurven spiegelt die genauen Perioden der Unter- und Überschätzung der NT-Messungen wider. Die CUSUM-Diagramme des prospektiven Datensatzes zeigt, dass das sofortige korrigierende Einschreiten bei schlechter Darstellung zu einer Wiedererlangung optimaler Ergebnisse führte und eine ausreichende Kontrolle ermöglichte. Die Histogramme der NT-Z-Faktoren, die im Gegensatz dazu nur eine geringe positive oder negative Verschiebung im Vergleich zu den erwarteten Werten aufgrund der Gaußschen Normalverteilung zeigten, konnten jedoch nicht erhoben werden, wenn eine schlechte Darstellung vorlag. Schlussfolgerung: Die Anwendung der CUSUM-Technik zur Qualitätsanalyse von sonografischen NT-Messungen bietet die Möglichkeit, prospektiv die Entwicklung des Könnens des Untersucher zu beobachten, die Kompetenz aufrecht zu erhalten und schnell die Zeit festzulegen, wenn ungenaue Messungen beginnen aufzutreten.

Abstract

Purpose: The cumulative summation technique (CUSUM) is an innovative method for the quality control of nuchal translucency (NT) measurements. CUSUM allows immediate corrective intervention as soon as an unacceptable tendency is noted. The aim of this study was to implement an objective and dynamic quality control method based on the CUSUM technique for prompt analysis of fetal NT measurement which would be compatible with different standards in routine clinical practice. The findings were compared to the standard NT quality control methods currently in use. Materials and Methods: Three sets of fetal NT measurements performed by three experienced examiners (I, II and III) were selected for retrospective evaluation. One additional set of NT measurements performed by examiner IV was prospectively assessed to approve the practicability of the method. NT measurements were conducted according to the recommendations of Fetal Medical Foundation (FMF) Germany and London. NT values were converted to Z-scores. For quality and accuracy evaluation, data were fed into the Digisono CUSUM software to create double CUSUM charts of Z-scores. In addition, histograms were composed from the Z-scores of each set of measurements and plotted against a normal Gaussian distribution. Results: Three different patterns of retrospective performance and one set of NT measurements that was evaluated prospectively are presented. The full alignment of Z-scores using CUSUM curves reflected exact periods of under- and overestimation of NT measurements. The CUSUM chart of the prospective data set reveals that prompt corrective intervention of poor performance resulted in reconstitution of optimal results and provided sufficient control. In contrast, histograms of NT Z-scores only showed a minor positive or negative shift as compared to the expected values on the basis of Gaussian distribution, but could not identify poor performance. Conclusion: Use of the CUSUM technique analysing the quality of sonographic NT measurements provides the possibility to prospectively observe the development of the examiner’s skills, to maintain competence and to promptly define the time when inaccurate measurements start to occur.

References

  • 1 Nyberg D A, Hyett J, Johnson J A et al. First-trimester screening.  Radiol Clin North Am. 2006;  44 837-861
  • 2 Axt-Fliedner R, Hartge D, Chiriac A et al. Long-term outcome for children born after a first-trimester measurement of increased nuchal translucency with a normal karyotype: a retrospective analysis.  Ultraschall in Med. 2009;  30 558-563
  • 3 Snijders R J, Noble P, Sebire N et al. UK multicentre project on assessment of risk of trisomy 21 by maternal age and fetal nuchal-translucency thickness at 10 – 14 weeks of gestation. Fetal Medicine Foundation First Trimester Screening Group.  Lancet. 1998;  352 343-346
  • 4 Czuba B, Borowski D, Cnota W et al. Ultrasonographic assessment of fetal nuchal translucency (NT) at 11th and 14th week of gestation – Polish multicentre study.  Neuro Endocrinol Lett. 2007;  28 175-181
  • 5 Rozenberg P, Malagrida L, Cuckle H et al. Down’s syndrome screening with nuchal translucency at 12(+ 0)–14(+ 0) weeks and maternal serum markers at 14(+ 1) – 17(+ 0) weeks: a prospective study.  Hum Reprod. 2002;  17 1093-1098
  • 6 Von Kaisenberg C S, Gasiorek-Wiens A, Bielicki M et al. Screening for trisomy 21 by maternal age, fetal nuchal translucency and maternal serum biochemistry at 11 – 14 weeks: a German multicenter study.  J Matern Fetal Neonatal Med. 2002;  12 89-94
  • 7 Merz E, Meinel K, Bald R et al. [DEGUM Level III recommendation for “follow-up” ultrasound examination ( = DEGUM Level II) in the 11-14 week period of pregnancy].  Ultraschall in Med. 2004;  25 299-301
  • 8 Herman A, Maymon R, Dreazen E et al. Nuchal translucency audit: a novel image-scoring method.  Ultrasound Obstet Gynecol. 1998;  12 398-403
  • 9 Nicolaides K H. First-trimester screening for chromosomal abnormalities.  Semin Perinatol. 2005;  29 190-194
  • 10 Merz E. First trimester screening - a new algorithm for risk calculation of chromosomal anomalies developed by FMF Germany.  Ultraschall in Med. 2007;  28 270-272 DOI: DOI 10.1055 /s-2007-963 257
  • 11 Spencer K, Bindra R, Nix A B et al. Delta-NT or NT MoM: which is the most appropriate method for calculating accurate patient-specific risks for trisomy 21 in the first trimester?.  Ultrasound Obstet Gynecol. 2003;  22 142-148
  • 12 Kestin I G. A statistical approach to measuring the competence of anaesthetic trainees at practical procedures.  Br J Anaesth. 1995;  75 805-809
  • 13 Bolsin S, Colson M. The use of the Cusum technique in the assessment of trainee competence in new procedures.  Int J Qual Health Care. 2000;  12 433-438
  • 14 Williams S M, Parry B R, Schlup M M. Quality control: an application of the cusum.  Bmj. 1992;  304 1359-1361
  • 15 Merz E, Thode C, Alkier A et al. A new approach to calculating the risk of chromosomal abnormalities with first-trimester screening data.  Ultraschall in Med. 2008;  29 639-645
  • 16 Wright D, Kagan K O, Molina F S et al. A mixture model of nuchal translucency thickness in screening for chromosomal defects.  Ultrasound Obstet Gynecol. 2008;  31 376-383
  • 17 Kurmanavicius J, Wright E M, Royston P et al. Fetal ultrasound biometry: 1. Head reference values.  Br J Obstet Gynaecol. 1999;  106 126-135
  • 18 Biau D J, Porcher R, Salomon L J. CUSUM: a tool for ongoing assessment of performance.  Ultrasound Obstet Gynecol. 2008;  31 252-255
  • 19 Wolfe R, Bolsin S, Colson M et al. Monitoring the rate of re-exploration for excessive bleeding after cardiac surgery in adults.  Qual Saf Health Care. 2007;  16 192-196
  • 20 Yap C H, Colson M E, Watters D A. Cumulative sum techniques for surgeons: a brief review.  ANZ J Surg. 2007;  77 583-586
  • 21 Maymon R, Tercanli S, Dreazen E et al. Comparison of pregnancy outcome of euploid fetuses with increased nuchal translucency (NT) expressed in NT MoM or delta-NT.  Ultrasound Obstet Gynecol. 2004;  23 477-481
  • 22 Staboulidou I, Wüstemann M, Vaske B et al. Interobserver Variability of the Measurement of Fetal Nasal Bone Length between 11 + 0 and 13 + 6 Gestation Weeks among Experienced and Inexperienced Sonographers.  Ultraschall in Med. 2009;  30  42-46
  • 23 Nisbet D L, Robertson A C, Schluter P J et al. Auditing ultrasound assessment of fetal nuchal translucency thickness: a review of Australian National Data 2002-2008.  Aust N Z J Obstet Gynaecol. 2010;  50 450-455
  • 24 Sabria J, Barcelo C, Arigita M et al. The cusum test applied in prospective nuchal translucency quality review.  Ultrasound Obstet Gynecol. 2011;  37 582-587
  • 25 D’Alton M E. Nuchal translucency quality monitoring: the transition from research to clinical care.  Obstet Gynecol. 2010;  116 806-807
  • 26 Kagan K O, Wright D, Etchegaray A et al. Effect of deviation of nuchal translucency measurements on the performance of screening for trisomy 21.  Ultrasound Obstet Gynecol. 2009;  33 657-664

Dr. Dalia Balsyte

Frauenheilkunde, UniversitätsSpital Zürich

Frauenklinikstrasse 10

8091 Zürich

Phone:  ++ 41/4 42/55 51 48

Fax:  ++ 41/4 42/55 44 30

Email: dalia.balsyte@usz.ch

    >