CC BY-NC-ND 4.0 · Indian J Radiol Imaging 2014; 24(02): 135-138
DOI: 10.4103/0971-3026.134397
Vascular and Interventional Radiology

Intercostal artery pseudoaneurysm complicating corrosive acid poisoning: Diagnosis with CT and treatment with transarterial embolisation

MV Chalapathi Chalapathi Rao
Department of Radio diagnosis, Krishna Institute of Medical Sciences, Secunderabad, Andhra Pradesh, India
,
Abhishek A Rathi
Department of Radio diagnosis, Krishna Institute of Medical Sciences, Secunderabad, Andhra Pradesh, India
,
Sharath P Reddy
Department of Gastroenterology, Krishna Institute of Medical Sciences, Secunderabad, Andhra Pradesh, India
,
Sambit Sahu
Department of Critical Care, Krishna Institute of Medical Sciences, Secunderabad, Andhra Pradesh, India
› Author Affiliations

Abstract

Pseudoaneurysms of intercostal artery are very rare. All the published cases have been caused by trauma, either iatrogenic or otherwise. They can cause hemothorax, retroperitoneal hemorrhage or can present as pulsatile chest mass. Doppler ultrasound, contrast-enhanced CT and conventional angiogram can accurately diagnose this condition. All the reported cases have been treated by embolisation, stenting or surgery. We report an unusual case of intercostal artery pseudoaneurysm arising as a complication of corrosive poisoning presenting with hematemesis and treated by glue embolisation. The authors believe this to be the first case of intercostal artery pseudoaneurysm that is non-traumatic, complicating corrosive poisoning and presenting with hematemesis.



Publication History

Article published online:
02 August 2021

© 2014. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).

Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India

 
  • References

  • 1 Sekino S, Takagi H, Kubota H, Kato T, Matsuno Y, Umemoto T. Intercostal artery pseudoaneurysm due to stab wound. J Vasc Surg 2005;42:352-6.
  • 2 Callaway MP, Wilde P, Angelini G. Treatment of a false aneurysm of an intercostal artery using a covered intracoronary stent-graft and a radial artery puncture. Br J Radiol 2000;73:1317-9.
  • 3 Casas JD, Perendreu J, Gallart A, Muchart J. Intercostal artery pseudoaneurysm after a percutaneous biliary procedure: Diagnosis with CT and treatment with transarterial embolization. J Comput Assist Tomogr 1997;21:729-30.
  • 4 Atherton WG, Morgan WE. False aneurysm of an intercostal artery after thoracoscopic sympathectomy. Ann R Coll Surg Engl 1997;79:229-30.
  • 5 Aoki T, Okada A, Tsuchida M, Hayashi J. Ruptured intercostal artery pseudoaneurysm after blunt thoracic trauma. Thorac Cardiovasc Surg 2003;51:346-7.
  • 6 Bluebond-Langner R, Pinto PA, Kim FJ, Hsu T, Jarrett TW. Recurrent bleeding from intercostal arterial pseudoaneurysm after retroperitoneal laparoscopic radical nephrectomy. Urology 2002;60:1111.
  • 7 Yamakado K, Nakatsuka A, Tanaka N, Takano K, Matsumura K, Takeda K. Transcatheter arterial embolization of ruptured pseudoaneurysms with coils and n-butyl cyanoacrylate. J Vasc Interv Radiol 2000;11:66-72.
  • 8 Melloni G, Bandiera A, Crespi G, Zannini P. Intercostal artery pseudoaneurysm after computed tomography-guided percutaneous fine needle aspiration lung biopsy. J Thorac Imaging 2012;27:W48-9.
  • 9 Kawai H, Ito M. Intercostal artery pseudoaneurysm after thoracoscopic lung resection. Gen Thorac Cardiovasc Surg 2009;57:550-2.
  • 10 Kim J, Shin JH, Yoon HK, Ko GY, Gwon DI, Kim EY, et al. Transcatheter renal artery embolization with N-butyl cyanoacrylate. Acta Radiol 2012;53:415-21.
  • 11 Monsignore LM, Scarpelini S, Santos JS, Abud DG. Urgent percutaneous transcatheter embolization of hemorrhagic hepatic lesions with N-butyl cyanoacrylate. Diagn Interv Radiol 2012;18:403-9.
  • 12 Ramasamy K, Gumaste VV. Corrosive ingestion in adults. J Clin Gastroenterol 2003;37:119-24.