Abstract

Purpose

To reveal whether minimal invasive implantation of a novel intramedullary device produces comparable outcomes with LCP fixation in patients with displaced midshaft clavicle fractures.

Methods

A prospective randomized two-arm study was performed on patients presenting with Robinson type 2B1 and 2B2 displaced midshaft clavicle fractures with >2 cm shortening. In group 1 (n = 35, mean age; 42.02 ± 13.87) patients received minimal invasive intramedullary fixation with Sonoma Crx device (Sonoma, USA) whereas in group 2 (n = 40, mean age; 39.07 ± 7.04) patients received 3.5 mm locking compression plate (Synthes, USA). Functional assessment was made using range of motion measurement (ROM), constant shoulder score and DASH disability of the arm, shoulder and hand (DASH) scoring.

Results

Mean time of operation was similar between the two groups (p = 0.46) whereas mean time of fluoroscopy was significantly longer in group 1 compared to group 2 (p < 0.001). At the 12 month follow-up, there was a slight but significant difference in ROM degrees between the two groups (p = 0.005). Mean quick DASH score was significantly lower in group 1 than that in group 2 (p < 0.001) whereas there was no significant difference in constant shoulder scores between the two groups (p = 0.06). Time to bony union was also shorter in group 1 compared to group 2 (p < 0.001).

Conclusion

Minimal invasive intramedullary implantation technique provided satisfactory clinical outcomes and shortened the time until bony union compared to LCP fixation. Further study on larger populations is required to establish whether the technique offers lower complication rates than LCP fixation.
Literatur
1.
Zurück zum Zitat Jørgensen A, Troelsen A, Ban I (2014) Predictors associated with nonunion and symptomatic malunion following non-operative treatment of displaced midshaft clavicle fractures—a systematic review of the literature. Int Orthop 38:2543–2549CrossRefPubMed Jørgensen A, Troelsen A, Ban I (2014) Predictors associated with nonunion and symptomatic malunion following non-operative treatment of displaced midshaft clavicle fractures—a systematic review of the literature. Int Orthop 38:2543–2549CrossRefPubMed
2.
Zurück zum Zitat Lenza M, Buchbinder R, Johnston RV, Belloti JC, Faloppa F (2013) Surgical versus conservative interventions for treating fractures of the middle third of the clavicle. Cochrane Database Syst Rev 6:CD009363 Lenza M, Buchbinder R, Johnston RV, Belloti JC, Faloppa F (2013) Surgical versus conservative interventions for treating fractures of the middle third of the clavicle. Cochrane Database Syst Rev 6:CD009363
3.
Zurück zum Zitat Ranalletta M, Rossi LA, Piuzzi NS, Bertona A, Bongiovanni SL, Maignon G (2014) Return to sports after plate fixation of displaced midshaft clavicular fractures in athletes. Am J Sports Med doi: 10.1177/0363546513501494 Ranalletta M, Rossi LA, Piuzzi NS, Bertona A, Bongiovanni SL, Maignon G (2014) Return to sports after plate fixation of displaced midshaft clavicular fractures in athletes. Am J Sports Med doi: 10.​1177/​0363546513501494​
4.
Zurück zum Zitat Robinson CM, Goudie EB, Murray IR, Jenkins PJ, Ahktar MA, Read EO et al (2013) Open reduction and plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a multicenter, randomized, controlled trial. J Bone Joint Surg Am 95:1576–1584CrossRefPubMed Robinson CM, Goudie EB, Murray IR, Jenkins PJ, Ahktar MA, Read EO et al (2013) Open reduction and plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a multicenter, randomized, controlled trial. J Bone Joint Surg Am 95:1576–1584CrossRefPubMed
5.
Zurück zum Zitat van der Meijden OA, Gaskill TR, Millett PJ (2012) Treatment of clavicle fractures: current concepts review. J Shoulder Elb Surg 21:423–429CrossRef van der Meijden OA, Gaskill TR, Millett PJ (2012) Treatment of clavicle fractures: current concepts review. J Shoulder Elb Surg 21:423–429CrossRef
6.
Zurück zum Zitat Will R, Englund R, Lubahn J, Cooney TE (2011) Locking plates have increased torsional stiffness compared to standard plates in a segmental defect model of clavicle fracture. Arch Orthop Trauma Surg 131:841–847CrossRefPubMed Will R, Englund R, Lubahn J, Cooney TE (2011) Locking plates have increased torsional stiffness compared to standard plates in a segmental defect model of clavicle fracture. Arch Orthop Trauma Surg 131:841–847CrossRefPubMed
7.
Zurück zum Zitat Golish SR, Oliviero JA, Francke EI, Miller MD (2008) A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation. J Orthop Surg Res 3:28CrossRefPubMedPubMedCentral Golish SR, Oliviero JA, Francke EI, Miller MD (2008) A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation. J Orthop Surg Res 3:28CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat King PR, Ikram A, Lamberts RP (2014) The treatment of clavicular shaft fractures with an innovative locked intramedullary device. J Shoulder Elb Surg 17 King PR, Ikram A, Lamberts RP (2014) The treatment of clavicular shaft fractures with an innovative locked intramedullary device. J Shoulder Elb Surg 17
9.
Zurück zum Zitat Beaton DE, Wright JG, Katz JN (2005) Development of the QuickDASH: comparison of three item-reduction approaches. J Bone Joint Surg Am 87:1038–1046PubMed Beaton DE, Wright JG, Katz JN (2005) Development of the QuickDASH: comparison of three item-reduction approaches. J Bone Joint Surg Am 87:1038–1046PubMed
10.
Zurück zum Zitat Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164 Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164
11.
Zurück zum Zitat Assobhi JE (2011) Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fractures. J Orthop Traumatol 12:185–192CrossRefPubMedPubMedCentral Assobhi JE (2011) Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fractures. J Orthop Traumatol 12:185–192CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Richardson M, Asadollahi S, Richardson L (2013) Management of acute displaced midshaft clavicular fractures using Herbert cannulated screw: technique and results in 114 patients. Int J Shoulder Surg 7:52–58CrossRefPubMedPubMedCentral Richardson M, Asadollahi S, Richardson L (2013) Management of acute displaced midshaft clavicular fractures using Herbert cannulated screw: technique and results in 114 patients. Int J Shoulder Surg 7:52–58CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Wu CL, Chang HC, Lu KH (2013) Risk factors for nonunion in 337 displaced midshaft clavicular fractures treated with Knowles pin fixation. Arch Orthop Trauma Surg 133:15–22CrossRefPubMed Wu CL, Chang HC, Lu KH (2013) Risk factors for nonunion in 337 displaced midshaft clavicular fractures treated with Knowles pin fixation. Arch Orthop Trauma Surg 133:15–22CrossRefPubMed
14.
Zurück zum Zitat Mudd CD, Quigley KJ, Gross LB (2011) Excessive complications of open intramedullary nailing of midshaft clavicle fractures with the Rockwood Clavicle Pin. Clin Orthop Relat Res 469:3364–3370CrossRefPubMedPubMedCentral Mudd CD, Quigley KJ, Gross LB (2011) Excessive complications of open intramedullary nailing of midshaft clavicle fractures with the Rockwood Clavicle Pin. Clin Orthop Relat Res 469:3364–3370CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Narsaria N, Singh AK, Arun GR, Seth RR (2014) Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating. J Orthop Traumatol 25 Narsaria N, Singh AK, Arun GR, Seth RR (2014) Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating. J Orthop Traumatol 25
16.
Zurück zum Zitat Wijdicks FJ, Houwert RM, Millett PJ, Verleisdonk EJ, Van der Meijden OA (2013) Systematic review of complications after intramedullary fixation for displaced midshaft clavicle fractures. Can J Surg 56:58–64CrossRefPubMedPubMedCentral Wijdicks FJ, Houwert RM, Millett PJ, Verleisdonk EJ, Van der Meijden OA (2013) Systematic review of complications after intramedullary fixation for displaced midshaft clavicle fractures. Can J Surg 56:58–64CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat King R, Ikram A (2013) Intramedullary locked fixation of clavicle shaft fractures–review of early results. Bone Joint J Orthop Proc Suppl 95:71 King R, Ikram A (2013) Intramedullary locked fixation of clavicle shaft fractures–review of early results. Bone Joint J Orthop Proc Suppl 95:71
18.
Zurück zum Zitat Wilson DJ, Weaver DL, Balog TP, Arrington ED (2013) Early postoperative failure of a new intramedullary fixation device for midshaft clavicle fractures. Orthopedics 36:1450–1453CrossRef Wilson DJ, Weaver DL, Balog TP, Arrington ED (2013) Early postoperative failure of a new intramedullary fixation device for midshaft clavicle fractures. Orthopedics 36:1450–1453CrossRef
19.
Zurück zum Zitat Palmer DK, Husain A, Phipatanakul WP, Wongworawat MD (2011) Failure of a new intramedullary device in fixation of clavicle fractures: a report of two cases and review of the literature. J Shoulder Elb Surg 20:1–4CrossRef Palmer DK, Husain A, Phipatanakul WP, Wongworawat MD (2011) Failure of a new intramedullary device in fixation of clavicle fractures: a report of two cases and review of the literature. J Shoulder Elb Surg 20:1–4CrossRef
20.
Zurück zum Zitat Jiang H, Qu W (2012) Operative treatment of clavicle midshaft fractures using a locking compression plate: comparison between mini-invasive plate osteosynthesis (MIPPO) technique and conventional open reduction. Orthop Traumatol Surg Res 98:666–671CrossRefPubMed Jiang H, Qu W (2012) Operative treatment of clavicle midshaft fractures using a locking compression plate: comparison between mini-invasive plate osteosynthesis (MIPPO) technique and conventional open reduction. Orthop Traumatol Surg Res 98:666–671CrossRefPubMed
21.
Zurück zum Zitat Duan X, Zhong G, Cen S, Huang F, Xiang Z (2011) Plating versus intramedullary pin or conservative treatment for midshaft fracture of clavicle: a meta-analysis of randomized controlled trials. J Shoulder Elb Surg 20:1008–1015CrossRef Duan X, Zhong G, Cen S, Huang F, Xiang Z (2011) Plating versus intramedullary pin or conservative treatment for midshaft fracture of clavicle: a meta-analysis of randomized controlled trials. J Shoulder Elb Surg 20:1008–1015CrossRef
22.
Zurück zum Zitat Houwert RM, Wijdicks FJ, Steins Bisschop C, Verleisdonk EJ, Kruyt M (2012) Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review. Int Orthop 36:579–585CrossRefPubMed Houwert RM, Wijdicks FJ, Steins Bisschop C, Verleisdonk EJ, Kruyt M (2012) Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review. Int Orthop 36:579–585CrossRefPubMed
23.
Zurück zum Zitat Barlow T, Beazley J, Barlow D (2013) A systematic review of plate versus intramedullary fixation in the treatment of midshaft clavicle fractures. Scott Med J 58:163–167CrossRefPubMed Barlow T, Beazley J, Barlow D (2013) A systematic review of plate versus intramedullary fixation in the treatment of midshaft clavicle fractures. Scott Med J 58:163–167CrossRefPubMed
24.
Zurück zum Zitat Zhu Y, Tian Y, Dong T, Chen W, Zhang F, Zhang Y (2015) Management of the mid-shaft clavicle fractures using plate fixation versus intramedullary fixation: an updated meta-analysis. Int Orthop 39:319–328CrossRefPubMed Zhu Y, Tian Y, Dong T, Chen W, Zhang F, Zhang Y (2015) Management of the mid-shaft clavicle fractures using plate fixation versus intramedullary fixation: an updated meta-analysis. Int Orthop 39:319–328CrossRefPubMed
25.
Zurück zum Zitat Zhou Y, Li XY, Li H, Xiao T (2015) Letter regarding article by Zhu et al: management of the mid-shaft clavicle fractures using plate fixation versus intramedullary fixation: an updated meta-analysis. Int Orthop 39:2521–2522CrossRefPubMed Zhou Y, Li XY, Li H, Xiao T (2015) Letter regarding article by Zhu et al: management of the mid-shaft clavicle fractures using plate fixation versus intramedullary fixation: an updated meta-analysis. Int Orthop 39:2521–2522CrossRefPubMed
Metadaten
Titel
Prospective randomized study comparing results of fixation for clavicular shaft fractures with intramedullary nail or locking compression plate
verfasst von
Murat Calbiyik
Deniz Ipek
Mehmet Taskoparan
Publikationsdatum
02.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 1/2017
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3192-5

Weitere Artikel der Ausgabe 1/2017

International Orthopaedics 1/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.