Abstract

This study compared the overall outcome after salvage revision total knee arthroplasty using hinged and nonhinged designs. We followed 26 total knee arthroplasties for an average of 20.4 months. The average age was 68.5 years. All patients had a salvage situation secondary to excessive bone loss, enlarged flexion gap, collateral ligament insufficiency, or extensor mechanism insufficiency. Ten patients received a hinged implant after an average of 2.8 prior total knee replacements. Sixteen patients received nonhinged constrained implants after an average of 3.4 prior total knee replacements. The outcome was evaluated using the Hospital for Special Surgery Score (HSS), the Knee Society Score (KSS), the Visual Analogue Scale for pain (VAS), the Tegner Activity Score, the Patella Score, and the Short Form-36 Health Survey (SF-36). There was a statistically significant difference in flexion range of motion between hinged and nonhinged designs (96.5° vs. 107.5°) but not in HSS, KSS, VAS, Tegner Activity Score, or Patella Score. Patients with hinged and nonhinged prostheses had significantly lower scores than an age-matched normal population in physical functioning, role limitations, and bodily pain on the SF-36 survey. However, patients with a hinged implant had no statistically significant difference compared to controls in the mental component summary. In salvage total knee arthroplasty the implant design does not significantly affect the overall functional outcome. However, patients with a hinged implant had significant better scores in the mental components of the SF36 quality-of-life assessment.
Literatur
1.
Zurück zum Zitat Bain AM (1973) Replacement of the knee joint with the Walldius prosthesis using cement fixation. Clin Orthop 94:65–71PubMed Bain AM (1973) Replacement of the knee joint with the Walldius prosthesis using cement fixation. Clin Orthop 94:65–71PubMed
2.
Zurück zum Zitat Barrack RL (2002) Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics 25:1020:1058 Barrack RL (2002) Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics 25:1020:1058
3.
Zurück zum Zitat Barrack RL, Lyons TR, Ingraham RQ, Johnson JC (2000) The use of a modular rotating hinge component in salvage revision total knee arthroplasty. J Arthroplasty 15:858–866CrossRefPubMed Barrack RL, Lyons TR, Ingraham RQ, Johnson JC (2000) The use of a modular rotating hinge component in salvage revision total knee arthroplasty. J Arthroplasty 15:858–866CrossRefPubMed
4.
Zurück zum Zitat Bugbee WD, Ammeen DJ, Engh GA (2001) Does implant selection affect outcome of revision knee arthroplasty. J Arthroplasty 16:581–585CrossRefPubMed Bugbee WD, Ammeen DJ, Engh GA (2001) Does implant selection affect outcome of revision knee arthroplasty. J Arthroplasty 16:581–585CrossRefPubMed
5.
Zurück zum Zitat Cameron HU, Hu C, Vyamont D (1997) Hinge total knee replacement revisited. Can J Surg 40:278–283PubMed Cameron HU, Hu C, Vyamont D (1997) Hinge total knee replacement revisited. Can J Surg 40:278–283PubMed
6.
Zurück zum Zitat Goldberg VM, Figgie MP, Figgie HE 3rd, Sobel M (1988) The results of revision total knee arthroplasty. Clin Orthop 226:86–92PubMed Goldberg VM, Figgie MP, Figgie HE 3rd, Sobel M (1988) The results of revision total knee arthroplasty. Clin Orthop 226:86–92PubMed
7.
Zurück zum Zitat Hassenpflug J (2000) Starr coupled knee endoprostheses as revision implants. Orthopade 29 [Suppl 1]:50 Hassenpflug J (2000) Starr coupled knee endoprostheses as revision implants. Orthopade 29 [Suppl 1]:50
8.
Zurück zum Zitat Hui FC, Fitzgerald RHJr (1980) Hinged total knee arthroplasty. J Bone Joint Surg Am 62:513–519PubMed Hui FC, Fitzgerald RHJr (1980) Hinged total knee arthroplasty. J Bone Joint Surg Am 62:513–519PubMed
9.
Zurück zum Zitat Iorio R, Healy WL, Richards JA (1999) Comparison of the hospital cost of primary and revision total hip arthroplasty after cost containment. Orthopedics 22:195–199PubMed Iorio R, Healy WL, Richards JA (1999) Comparison of the hospital cost of primary and revision total hip arthroplasty after cost containment. Orthopedics 22:195–199PubMed
10.
Zurück zum Zitat Ranawat CS, Flynn WF Jr, Saddler S, Hansraj KK, Maynard MJ (1993) Long-term results of the total condylar knee arthroplasty. A 15-year survivorship study. Clin Orthop 286:94–102 Ranawat CS, Flynn WF Jr, Saddler S, Hansraj KK, Maynard MJ (1993) Long-term results of the total condylar knee arthroplasty. A 15-year survivorship study. Clin Orthop 286:94–102
11.
Zurück zum Zitat Rand JA (1991) Revision total knee arthroplasty using the total condylar III prosthesis. J Arthroplasty 6:279–284PubMed Rand JA (1991) Revision total knee arthroplasty using the total condylar III prosthesis. J Arthroplasty 6:279–284PubMed
12.
Zurück zum Zitat Robertsson O, Dunbar M, Knutson K, Lewold S, Lidgren L (1999) Validation of the Swedish Knee Arthroplasty Register: a postal survey regarding 30,376 knees operated on between 1975 and 1995. Acta Orthop Scand 70:467–472PubMed Robertsson O, Dunbar M, Knutson K, Lewold S, Lidgren L (1999) Validation of the Swedish Knee Arthroplasty Register: a postal survey regarding 30,376 knees operated on between 1975 and 1995. Acta Orthop Scand 70:467–472PubMed
13.
Zurück zum Zitat Shaw JA, Balcom W, Greer RB 3rd (1989) Total knee arthroplasty using the kinematic rotating hinge prosthesis. Orthopedics 12:647–654PubMed Shaw JA, Balcom W, Greer RB 3rd (1989) Total knee arthroplasty using the kinematic rotating hinge prosthesis. Orthopedics 12:647–654PubMed
14.
Zurück zum Zitat Springer BD, Hanssen AD, Sim FH, Lewallen DG (2001) The kinematic rotating hinge prosthesis for complex knee arthroplasty. Clin Orthop 392:283–291PubMed Springer BD, Hanssen AD, Sim FH, Lewallen DG (2001) The kinematic rotating hinge prosthesis for complex knee arthroplasty. Clin Orthop 392:283–291PubMed
15.
Zurück zum Zitat Van Loon CJ, Pluk C, de Waal Malefijt MC, de Kock M, Veth RP (2001) The GSB total knee arthroplasty. A medium- and long term follow-up and survival analysis. Arch Orthop Trauma Surg 121:26–30CrossRefPubMed Van Loon CJ, Pluk C, de Waal Malefijt MC, de Kock M, Veth RP (2001) The GSB total knee arthroplasty. A medium- and long term follow-up and survival analysis. Arch Orthop Trauma Surg 121:26–30CrossRefPubMed
16.
Zurück zum Zitat Walker PS, Manktelow AR (2001) Comparison between a constrained condylar and a rotating hinge in revision knee surgery. Knee 8:269–279CrossRefPubMed Walker PS, Manktelow AR (2001) Comparison between a constrained condylar and a rotating hinge in revision knee surgery. Knee 8:269–279CrossRefPubMed
17.
Zurück zum Zitat Westrich GH, Mollano AV, Sculco TP, Buly RL, Laskin RS, Windsor R (2000) Rotating hinge total knee arthroplasty in severely affected knees. Clin Orthop 379:195–208PubMed Westrich GH, Mollano AV, Sculco TP, Buly RL, Laskin RS, Windsor R (2000) Rotating hinge total knee arthroplasty in severely affected knees. Clin Orthop 379:195–208PubMed
Metadaten
Titel
Quality of life and clinical outcome in salvage revision total knee replacement: hinged vs. total condylar design
verfasst von
Susanne Fuchs
Christian Sandmann
Georg Gerdemann
Adrian Skwara
Carsten O. Tibesku
Friedrich Bottner
Publikationsdatum
01.03.2004
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 2/2004
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-003-0401-8

Weitere Artikel der Ausgabe 2/2004

Knee Surgery, Sports Traumatology, Arthroscopy 2/2004 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.