Skip to main content

06.09.2024 | Imaging Informatics and Artificial Intelligence

Quality of radiomics research: comprehensive analysis of 1574 unique publications from 89 reviews

verfasst von: Burak Kocak, Ali Keles, Fadime Kose, Abdurrezzak Sendur

Erschienen in: European Radiology

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study aims to comprehensively evaluate the quality of radiomics research by examining unique papers from reviews using the radiomics quality score (RQS).

Methods

A literature search was conducted in PubMed (last search date: April 14, 2024). Systematic or non-systematic reviews using the RQS to evaluate radiomic studies were potentially included. Exclusion was applied at two levels: first, at the review level, and second, at the study level (i.e., for the individual articles previously evaluated within the reviews). Score-wise and item-wise analyses were performed, along with trend, multivariable, and subgroup analyses based on baseline study characteristics and validation methods.

Results

A total of 1574 unique papers (published online between 1999 and 2023) from 89 reviews were included in the final analysis. The median RQS percentage was 31% with an IQR of 25% (25th–75th percentiles, 14–39%). A positive correlation between median RQS percentage and publication year (2014–2023) was found, with Kendall’s tau coefficient of 0.908 (p < 0.001), suggesting an improvement in quality over time. The quality of radiomics publications significantly varied according to different subfields of radiology (p < 0.001). Around one-third of the publications (32%) lacked a separate validation set. Papers with internal validation (54%) dominated those with external validation (14%). Higher-quality validation practices were significantly associated with better RQS percentage scores, independent of the validation’s effect on the final score. Item-wise analysis revealed significant shortcomings in several areas.

Conclusion

Radiomics research quality is low but improving according to RQS. Significant variation exists across radiology subfields. Critical areas were identified for targeted improvement.

Clinical relevance statement

Our study shows that the quality of radiomics research is generally low but improving over time, with item-wise analysis highlighting critical areas needing improvement. It also reveals that the quality of radiomics research differs across subfields and validation methods.

Key Points

  • Overall quality of radiomics research remains low and highly variable, although a significant positive trend suggests an improvement in quality over time.
  • Considerable variations exist in the quality of radiomics publications across different subfields of radiology and validation types.
  • The item-wise analysis highlights several critical areas requiring attention, emphasizing the need for targeted improvements.

Graphical abstract

Anhänge
Nur mit Berechtigung zugänglich
Literatur
Metadaten
Titel
Quality of radiomics research: comprehensive analysis of 1574 unique publications from 89 reviews
verfasst von
Burak Kocak
Ali Keles
Fadime Kose
Abdurrezzak Sendur
Publikationsdatum
06.09.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-024-11057-z

Neu im Fachgebiet Radiologie

KI-gestütztes Mammografiescreening überzeugt im Praxistest

Mit dem Einsatz künstlicher Intelligenz lässt sich die Detektionsrate im Mammografiescreening offenbar deutlich steigern. Mehr unnötige Zusatzuntersuchungen sind laut der Studie aus Deutschland nicht zu befürchten.

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Die elektronische Patientenakte kommt: Das sollten Sie jetzt wissen

Am 15. Januar geht die „ePA für alle“ zunächst in den Modellregionen an den Start. Doch schon bald soll sie in allen Praxen zum Einsatz kommen. Was ist jetzt zu tun? Was müssen Sie wissen? Wir geben in einem FAQ Antworten auf 21 Fragen.

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.