Quantification of myocardial strain in patients with isolated left ventricular non-compaction and healthy subjects using deformable registration algorithm: comparison with feature tracking
Systolic dysfunction of the left ventricle is frequently associated with isolated left ventricular non-compaction (iLVNC). Clinically, the ejection fraction (EF) is the primary index of cardiac function. However, changes of EF usually occur later in the disease course. Feature tracking (FT) and deformable registration algorithm (DRA) have become appealing techniques for myocardial strain assessment.
Methods
Thirty patients with iLVNC (36.7 ± 13.3 years old) and fifty healthy volunteers (42.3 ± 13.6 years old) underwent cardiovascular magnetic resonance (CMR) examination on a 1.5 T MR scanner. Strain values in the radial, circumferential, longitudinal directions were analyzed based on the short-axis and long-axis cine images using FT and DRA methods. The iLVNC patients were further divided based on the ejection fraction, into EF ≥ 50% group (n = 11) and EF < 50% group (n = 19). Receiver-operating-characteristic (ROC) analysis was performed to assess the diagnostic performance of the global strain values. Intraclass correlation coefficient (ICC) analysis was used to evaluate the intra- and inter-observer agreement.
Results
Global radial strain (GRS) was statistically lower in EF ≥ 50% group compared with control group [GRS (DRA)/% vs. controls: 34.6 ± 7.0 vs. 37.6 ± 7.2, P < 0.001; GRS (FT)/% vs. controls: 37.4 ± 13.2 vs. 56.9 ± 16.4, P < 0.01]. ROC analysis of global strain values derived from DRA and FT demonstrated high area under curve (range, 0.743–0.854). DRA showed excellent intra- and inter-observer agreement of global strain in both iLVNC patients (ICC: 0.995–0.999) and normal controls (ICC: 0.934–0.996). While for FT analysis, global radial strain of normal controls showed moderate intra-observer (ICC: 0.509) and poor inter-observer agreement (ICC: 0.394).
Conclusions
In patients with iLVNC, DRA can be used to quantitatively analyze the strain of left ventricle, with global radial strain being an earlier marker of LV systolic dysfunction. DRA has better reproducibility in evaluating both the global and segmental strain.
Hinweise
Jia Liu and Yumin Li are the first authors of this article.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
iLVNC
Isolated left ventricular non-compaction
DRA
Deformable registration algorithm
FT
Feature tracking
LVEF
Left ventricular ejection fraction
CMR
Cardiovascular magnetic resonance
SSFP
Standard steady state free precession
BSA
Body surface area
EDVI
Left ventricular end-diastolic volume index
ESVI
End-systolic volume index
SVI
Stroke volume index
CI
Cardiac index
GRS
Global radial strain
GCS
Global circumferential strain
GLS
Global longitudinal strain
ROC
Receiver-operator-characteristic
ICC
Intraclass correlation coefficient
AUC
Area under curve
Background
Left ventricular non-compaction (LVNC) is an uncommon cardiomyopathy characterized by excessively prominent trabeculations and deep inter-trabecular recesses. The thickened wall of left ventricle (LV) consists of a thin compacted epicardial layer and a thick non-compacted endocardial layer. This disease is likely to result from an arrest of normal embryogenesis, mainly involving the endocardium and myocardium [1]. It may develop in isolation (isolated left ventricular non-compaction, iLVNC) or accompanied by congenital heart disease [2].
Cardiac magnetic resonance (CMR) imaging is considered as the standard of reference to clinically assess volumes and global systolic function of left ventricle [2]. LV systolic dysfunction is frequently associated with iLVNC [3]. Clinically, left ventricular ejection fraction (LVEF) is the most commonly used indicator for evaluating cardiac function. However, changes in the LVEF usually occur late in the disease course [4]. Besides, the wall motion is usually evaluated on a subjective basis and the accuracy may depend on the experience of the rater. Previous studies have shown that myocardial strain may facilitate early detection and outcome assessment of some cardiac diseases [5, 6]. The term “strain” is defined as the change in fiber length divided by the original length, and can be quantified in three directions of myocardial fiber (radial, circumferential, and longitudinal) [7]. Several post-processing methods have been applied using standard steady state free precession (SSFP) cine images, such as deformable registration algorithm (DRA) and feature tracking (FT). DRA and FT can evaluate both global and regional myocardial function in volunteers and patients [8, 9]. Recent FT studies indicated that global strain values based on CMR were impaired in LVNC patients [10, 11]. Up to date, DRA technique has not been applied to quantify myocardial strain in patients with iLVNC.
Anzeige
In the present study, we aimed to 1) investigate the role of strain assessment in detection of early dysfunction of left ventricle in patients with iLVNC, 2) assess the accuracy of global strain to distinguish iLVNC from healthy people, and 3) compare the reproducibility of global and segmental strains derived from DRA and FT in healthy volunteers and iLVNC patients.
Methods
Study population
The diagnosis of LVNC was based on the presence of established CMR and clinical criteria: 1) a thin, compacted (C) epicardial layer and a thick, non-compacted (NC) endocardial layer with prominent trabeculations and deep intertrabecular recesses; 2) NC/C ratio measured at end-diastole > 2.3 in at least one LV segment [12]. Exclusion criteria included: age < 18 years, significant valvular heart disease, clinical or CMR evidence of ischemic heart disease and evidence of concomitant congenital heart disease. Fifty age- and sex-matched healthy volunteers who responded to advertisements were recruited to participate in this study. Eventually, thirty patients with iLVNC (63.3% males, 36.7 ± 13.3 years old) and fifty healthy volunteers (58% males, 42.3 ± 13.6 years old) were included.
CMR imaging acquisition
All subjects underwent a standard CMR examination with a 1.5 T scanner (MAGNETOM Aera, Siemens Healthcare, Erlangen, Germany). A stack of short-axis views and three long-axis (2-, 3-, and 4-chamber) views were acquired. The whole LV was imaged from the base to the apex with the following parameters: repetition time (TR)/echo time (TE) of 2.9/1.2 ms, slice thickness of 6 mm, matrix of 186 × 256 pixels, and flip angle of 80°.
CMR image analysis
Cardiac function
A dedicated workstation employing commercial software (Argus, Siemens Healthcare, Erlangen, Germany) was used to analyze LV volume and function. Cardiac volumetric and functional parameters were quantified based on manual delineation of the endocardial and epicardial borders using a stack of continuous short-axis cine images. The trabeculae and papillary muscles were included in the left ventricular cavity. The end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) were measured and indexed to the patient’s body surface area (BSA).
Strain
Cine bSSFP-based peak systolic strains were analyzed using a prototype DRA software (TrufiStrain, version 2.0, Siemens Healthcare, Erlangen, Germany) and FT software (Medis Suite, version 3.0, Medis Medical Imaging Systems, Leiden, the Netherlands). For FT analysis, we delineated the endocardial and epicardial contours manually at end-systole and adjusted them at end-diastole. For DRA analysis, the contours were drawn manually at end-diastole; then the consecutive contours on the other phases were tracked automatically through the cardiac cycle (Fig. 1). Detailed analysis with DRA has been described previously [13]. The global longitudinal strain (GLS) was calculated based on the average of the peak systolic strain values measured by the three long axis orientations. Short-axis views of the basal, mid-ventricular, and apical levels were used to analyze radial and circumferential strain. After a reference point was set up at the anterior insertion site, segmental circumferential strain and radial strain were calculated based on the 16-segment model. Finally, the peak systolic global and segmental myocardial strains were obtained for analysis.
×
Statistical analysis
SPSS (version 22.0; Chicago, IL, USA) and MedCalc (version 19.0.7; Ostend, Belgium) software was used to perform the statistical analyses. The Anderson–Darling test was used to check the normality. Continuous data were expressed as the mean ± standard deviation. Means of two continuous normally distributed variables were compared by independent samples Student’s t-test. Other comparisons were performed using the Mann–Whitney U test. Pairwise comparisons between groups were performed using one-way ANOVA (normal distribution) or Kruskal–Wallis test with Bonferroni correction (non-normal distribution).
Anzeige
Receiver-operator-characteristic (ROC) analyses of global strains determined by DRA and FT were performed to assess the diagnostic capability of strain parameters in distinguishing iLVNC from healthy volunteers. The comparisons of areas under the curve (AUC) were performed using Delong test [14]. Correlation analysis between two parameters used the Spearman rank correlation test or Pearson correlation analysis.
For strain analysis, reproducibility was tested by using the intraclass correlation coefficient (ICC) on 15 healthy volunteers and 15 iLVNC patients. Inter-observer variability was analyzed on the same image set by two independent investigators (J.L., YM.L.). Intra-observer variability was analyzed on the same image set by one investigator (J.L.) with two readings 2 weeks apart. Based on the 95% confidence interval of the ICC estimate, values less than 0.50, between 0.50 and 0.75, between 0.75 and 0.90, and greater than 0.90 were indicative of poor, moderate, good, and excellent reliability, respectively [15].
Results
Demographic and clinical characteristics
All demographic and cardiac MRI characteristics are shown in Table 1.
Table 1
Clinical characteristics and parameters of cardiac function and myocardial deformation
Parameters
iLVNC (n = 30)
Controls (n = 50)
P value
Age (years)
36.7 ± 13.3
42.3 ± 13.6
0.101
Male (%)
19 (63.3%)
29 (58%)
0.637
BMI (kg/m2)
23.2 ± 3.7
22.8 ± 2.9
0.588
HR (bpm)
66.7 ± 9.0
65.3 ± 9.2
0.249
LVEF (%)
42.5 ± 14.3
57.7 ± 4.7
< 0.001
EDVI (ml·m− 2)
79.5 ± 44.8
69.8 ± 13.3
0.827
ESVI (ml·m− 2)
49.1 ± 40.0
29.9 ± 7.4
0.016
SVI (ml·m− 2)
30.4 ± 12.4
39.9 ± 7.4
< 0.001
CI (L·min− 1·m− 2)
2.0 ± 0.8
2.6 ± 0.5
< 0.001
NoNC
4.0 ± 2.2
–
–
GLS (DRA)/%
−11.9 ± 3.9
− 14.5 ± 1.4
0.001
GRS (DRA)/%
26.3 ± 11.0
37.6 ± 7.2
< 0.001
GCS (DRA) /%
−12.1 ± 4.2
−16.4 ± 1.6
< 0.001
GLS (FT)/%
−17.8 ± 6.4
− 23.3 ± 2.8
< 0.001
GRS (FT)/%
33.2 ± 23.5
56.9 ± 16.4
< 0.001
GCS (FT) /%
−15.5 ± 6.6
−22.5 ± 2.6
< 0.001
BMI Body mass index, HR Heart rate, LVEF Left ventricular ejection fraction, EDVI End-diastolic volume index, ESVI End-systolic volume index, SVI Stroke volume index, CI Cardiac index, NoNC Number of non-compacted segment, DRA Deformable registered algorithm, FT Feature tracking, GRS Global radial strain, GCS Global circumferential strain, GLS Global longitudinal strain
Correlations between LVEF and global strain of iLVNC patients
Correlations between left ventricular ejection fraction (LVEF) and global strain values derived from DRA and FT in iLVNC patients are shown in Fig. 2. All global strain values showed significant correlations with LVEF (P < 0.001 for all).
×
Comparison of strain values derived from DRA and FT among iLVNC patients with EF ≥ 50% group, EF < 50% group, and control group
As shown in Table 2, global radial strain (GRS) values derived from DRA and FT were significantly lower in iLVNC patients with EF ≥ 50% than those in control group, whereas global circumferential strain (GCS) and global longitudinal strain (GLS) values didn’t show significant difference between iLVNC patients with EF ≥ 50% and normal subjects.
Table 2
Comparison between iLVNC patients with EF ≥ 50%, EF < 50% and normal controls
Parameters
iLVNC (n = 30)
Controls (n = 50)
EF ≥ 50% (n = 11)
EF < 50% (n = 19)
GRS (DRA)/%
34.6 ± 7.0*
21.4 ± 10.0*
37.6 ± 7.2
GCS (DRA)/%
−15.6 ± 1.1
−10.0 ± 4.0*
− 16.4 ± 1.6
GLS (DRA)/%
−14.0 ± 2.4
− 10.1 ± 3.5*
−14.5 ± 1.4
GRS (FT)/%
37.4 ± 13.2#
26.6 ± 16.3*
56.9 ± 16.4
GCS (FT)/%
−21.3 ± 3.2
−12.2 ± 5.7*
−22.5 ± 2.6
GLS (FT)/%
− 22.9 ± 2.6
−14.8 ± 6.0*
−23.3 ± 2.8
EF
56.4 ± 3.9
34.5 ± 11.6*
57.7 ± 4.7
#P < 0.01 vs. controls, *P < 0.001 vs. controls
Distinction of iLVNC patients and normal subjects
The results of ROC analyses using global strains to distinguish iLVNC patients from normal controls are shown in Table 3. ROC analysis using GLS, GRS, and GCS derived from DRA and FT all demonstrated high AUC values. However, on pairwise comparison of ROC curves, there were no statistically significant differences (P > 0.05).
Table 3
Accuracy of the global strains (GLS, GRS and GCS) derived from two methods (DRA and FT) for the distinction of iLVNC
Sensitivity (%)
Specificity (%)
AUC
Cutoff value
95% CI
GLS
DRA
76.7
68.0
0.743
−13.7
0.616–0.871
FT
60.0
100.0
0.794
−18.9
0.680–0.908
GRS
DRA
68.0
90.0
0.850
35.0
0.765–0.935
FT
88.0
73.3
0.854
40.1
0.761–0.947
GCS
DRA
60.0
86.0
0.749
−14.8
0.631–0.868
FT
70.0
80.0
0.818
−20.0
0.715–0.921
AUC Area under the curve, CI Confidence interval
Intra-observer and inter-observer reproducibility of global strains
Intra- and inter-observer agreements of global myocardial strain for DRA and FT are shown in Table 4. DRA showed excellent intra- and inter-observer agreement in both iLVNC patients and normal controls. While for FT analysis, GRS of normal controls showed moderate intra-observer and poor inter-observer agreement. The intra- and inter-observer agreements of global strain derived from FT performed in iLVNC patients were higher than those in normal controls, especially the GRS.
Table 4
Reproducibility of the global strains (GLS, GRS and GCS) derived from two methods (DRA and FT) using intraclass correlation coefficient analysis
Controls
iLVNC
DRA
FT
DRA
FT
GRS
inter
0.996a
0.394
0.999a
0.716
intra
0.996a
0.509
0.996a
0.785a
GCS
inter
0.934a
0.891a
0.996a
0.986a
intra
0.958a
0.843a
0.995a
0.982a
GLS
inter
0.982a
0.891a
0.995a
0.976a
intra
0.977a
0.879a
0.997a
0.980a
intra Intra-observer agreement, inter Inter-observer agreement
a Intraclass correlation coefficient>75%
Intra-observer and inter-observer reproducibility of segmental strains
As shown in Table 5, DRA showed better observer agreement for segmental strains compared with FT in both healthy volunteers and patients.
Table 5
Reproducibility of segmental strains (RS, CS and LS) using two methods (DRA and FT) in controls and iLVNC patients
Segment
Controls
iLVNC
DRA
FT
DRA
FT
RS
CS
LS
RS
CS
LS
RS
CS
LS
RS
CS
LS
1
inter
0.984a
0.866a
0.714
0.266
0.747
0.702
0.720
0.704
0.951a
0.312
0.704
0.886a
intra
0.984a
0.919a
0.991a
0.629
0.782a
0.744
0.978a
0.959a
0.939a
0.265
0.578
0.919a
2
inter
0.713
0.870a
0.989a
0.448
0.600
0.804a
0.979a
0.746
0.993a
0.561
0.746
0.532
intra
0.804a
0.902a
0.996a
0.752a
0.661
0.820a
0.936a
0.794a
0.996a
0.233
0.649
0.891a
3
inter
0.984a
0.933a
0.922a
0.709
0.612
0.771a
0.730
0.823a
0.969a
0.619
0.823a
0.853a
intra
0.989a
0.989a
0.936a
0.802a
0.766a
0.806a
0.932a
0.962a
0.984a
0.618
0.821a
0.745
4
inter
0.706
0.909a
0.940a
0.369
0.786a
0.578
0.912a
0.860a
0.979a
0.718
0.860a
0.946a
intra
0.740
0.951a
0.971a
0.683
0.904a
0.694
0.996a
0.989a
0.978a
0.876a
0.805a
0.916a
5
inter
0.686
0.910a
0.924a
0.174
0.771a
0.809a
0.913a
0.427
0.970a
0.775a
0.427
0.923a
intra
0.739
0.920a
0.958a
0.435
0.800a
0.841a
0.998a
0.993a
0.965a
0.503
0.389
0.560
6
inter
0.880a
0.915a
0.962a
0.164
0.861a
0.935a
0.883a
0.274
0.914a
0.423
0.274
0.854a
intra
0.892a
0.922a
0.989a
0.337
0.893a
0.956a
0.996a
0.858a
0.982a
0.173
0.338
0.688
7
inter
0.967a
0.956a
0.976a
0.337
0.809a
0.761a
0.951a
0.914a
0.955a
0.576
0.914a
0.934a
intra
0.980a
0.979a
0.981a
0.403
0.881a
0.798a
0.998a
0.982a
0.978a
0.491
0.894a
0.868a
8
inter
0.915a
0.827a
0.784a
0.133
0.554
0.681
0.929a
0.883a
0.964a
0.074
0.883a
0.543
intra
0.936a
0.868a
0.680
0.303
0.656
0.752a
0.994a
0.528
0.956a
0.428
0.627
0.854a
9
inter
0.740
0.978a
0.980a
0.049
0.850a
0.558
0.695
0.979a
0.988a
0.742
0.979a
0.901a
intra
0.735
0.975a
0.976a
0.509
0.875a
0.776a
0.823a
0.982a
0.991a
0.756a
0.943a
0.898a
10
inter
0.939a
0.774a
0.955a
0.100
0.643
0.827a
0.948a
0.923a
0.981a
0.328
0.923a
0.949a
intra
0.951a
0.843a
0.945a
0.098
0.678
0.850a
0.964a
0.977a
0.921a
0.475
0.823a
0.920a
11
inter
0.839a
0.910a
0.982a
0.292
0.716
0.856a
0.980a
0.916a
0.978a
0.733
0.916a
0.956a
intra
0.842a
0.945a
0.980a
0.294
0.718
0.896a
0.992a
0.985a
0.989a
0.689
0.711
0.759a
12
inter
0.976a
0.794a
0.985a
0.144
0.580
0.691
0.934a
0.944a
0.976a
0.658
0.944a
0.867a
intra
0.981a
0.867a
0.989a
0.310
0.586
0.710
0.994a
0.963a
0.994a
0.708
0.892a
0.723
13
inter
0.980a
0.830a
0.991a
0.334
0.890a
0.893a
0.579
0.784a
0.994a
0.426
0.784a
0.908a
intra
0.981a
0.861a
0.991a
0.367
0.912a
0.898a
0.988a
0.975a
0.995a
0.541
0.819a
0.959a
14
inter
0.977a
0.957a
0.975a
0.189
0.909a
0.649
0.848a
0.660
0.986a
0.418
0.660
0.953a
intra
0.989a
0.958a
0.984a
0.335
0.928a
0.685
0.995a
0.447
0.961a
0.563
0.887a
0.834a
15
inter
0.739
0.942a
0.975a
0.051
0.838a
0.816a
0.804a
0.931a
0.964a
0.352
0.931a
0.840a
intra
0.791a
0.951a
0.992a
0.095
0.868a
0.906a
0.984a
0.960a
0.993a
0.638
0.936a
0.682
16
inter
0.786a
0.796a
0.951a
0.008
0.812a
0.885a
0.951a
0.938a
0.997a
0.426
0.938a
0.954a
intra
0.808a
0.846a
0.965a
0.024
0.908a
0.886a
0.998a
0.325
0.989a
0.552
0.881a
0.935a
intra Intra-observer agreement, inter Inter-observer agreement
a Intraclass correlation coefficient>75%
Anzeige
Discussion
Our study found that global radial strain derived from DRA and FT was reduced in iLVNC patients with normal EF. Global strain values had high diagnostic capability to distinguish iLVNC from healthy volunteers. Compared with FT, DRA showed better intra- and inter-observer agreement for global and segmental strains in both normal controls and iLVNC patients.
In our study, global strains derived from both DRA and FT had good correlation with the LVEF. Compared to EF which acts as a global functional parameter, strain reveals the microscopic view of myocardial function. Murphy and colleagues have stated that there is a long preclinical phase of disease during which patients have no symptoms or are pauci-symptomatic [16]. A previous study pointed out that patients with EF < 50% were eligible for drug treatment [17]. In our study, patients with iLVNC were further divided into two groups based on the ejection fraction (EF): EF ≥ 50% and EF < 50%. We found that GRS values derived from DRA and FT were significantly reduced in iLVNC patients with EF ≥ 50%. This indicates that GRS may detect early left ventricular dysfunction in iLVNC patients with normal EF. As previous studies have proposed, the compaction progress of the myocardium develops from the epicardium to the endocardium and from the ventricular base to the apex; therefore, arrest of the compaction process is prone to occur in the apical endocardium of the ventricle [18, 19]. The left ventricular apex has a great component of radially and circumferentially oriented myocardial fibers, rather than longitudinally oriented fibers, while circumferential myofibers typically distribute in the epicardial region of LV wall [20]. The differences of anatomy may help understand the potentially superior clinical significance of radial strain in iLVNC patients.
In our study, all three global strains by the DRA and FT had high AUC values (0.743 and higher) in distinguishing iLVNC from healthy volunteers. However, there was no statistically significance difference of the AUC values between the two methods in any orientation. As mentioned, arrest of the compaction process is prone to occur in the apical endocardium of the ventricle [18]. However, in real situation, the distribution of the trabeculae may be random and complex. In addition, the strain reduction may further aggravate in the range and extent as the disease progresses, hence the global strains may be affected in all directions with no significant differences.
When evaluating the robustness of a strain-analysis method, reproducibility is an important factor. In our study, the reproducibility analysis was performed in both iLVNC patients and volunteers. We found that the intra- and inter-observer agreements of global and segmental strains were better for DRA than FT in both normal controls and iLVNC patients, especially for radial strain analysis. This is probably because that DRA is a novel method to analyze cardiac strain on a pixel-by-pixel basis. Furthermore, DRA can automatically segment the left ventricle on CMR cine images. It helps obtain the deformation from any frame to any other frame in the cardiac cycle by recovering a set of both forward and backward deformation fields. Different segmentation contours can be formed on each phase in the cardiac cycle, and then propagated to other phases [21, 22]. Thereafter, the best combination of contour series is retained which makes the algorithm more efficient and time-saving. Although the FT algorithm has been developed for analyzing myocardial motion for a long time, applying it to clinical image data is challenging. After delineating the contours on one reliable image, the traced contours are propagated in time by identifying the same features in the following frames (optical flow technique). But some features may fade from one frame to another during tracking, and blood motion can interfere with the deformation computation [8]. It is very likely that small differences in manual contouring of endo- and epicardial borders between observers may have an important impact on radial strain measurements, while the impact on the reproducibility of longitudinal or circumferential strain is much smaller. A previous study also reported that reproducibility in DRA analysis was better than FT [23]. As mentioned above, the tracking signal sources are different between the two techniques, and readers need to adjust the contours when performing FT analysis, which is not needed when using DRA. The better reproducibility of DRA in both global and segmental view might be, more likely, related to the fully automated segmentation approach, as compared with FT [21]. A recent study comparing DRA and tagged CMR showed that the DRA demonstrated a strong relationship with the harmonic phase (HARP) for myocardial GLS (R2 = 0.75; P < 0.0001) and GCS (R2 = 0.61; P < 0.0001), and DRA demonstrated consistently lower coefficient of variation (CV) than tagged CMR [24].
Anzeige
A study using speckle tracking echocardiography indicated that apical circumferential strain may be a potential diagnostic tool for children with noncompaction cardiomyopathy (sensitivity: 87%, specificity: 79%, AUC: 0.88, P < 0.001) [25]. Since DRA showed better reproducibility in segmental strain in our study, we believe that it may be a good tool for evaluating the value of CMR-based segmental strain in diagnosing iLVNC patients in the future.
Meanwhile, we found that reproducibility of FT-based GRS performed in iLVNC patients was better than that in normal controls, while FT-based GCS and GLS both showed a good reproducibility in controls and iLVNC patients. The radial strain estimate heavily depends on how well the myocardial border is detected, and large variations were observed in radial strain [26]. As for the better reproducibility in iLVNC patients in our study, we assume that patients with iLVNC have thinner myocardium and weaker myocardial motion than normal people. Therefore, to some extent, the contour can be better and more accurately tracked by readers. In terms of absolute values, DRA-derived strain values were consistently lower (more negative) compared to FT, especially for radial strain values. Previous studies have demonstrated higher absolute values by FT compared to CMR tagging [27, 28]. Results of the DRA analysis in our study are within normal ranges of reported MR tagging data. Strain quantification methods differ considerably in their registration of myocardial motion, so it is not surprising that some techniques generate similar values [29, 30] while others do not [31, 32].
Limitations
This study has some limitations that should be acknowledged. Patients with iLVNC were retrospectively enrolled, the limitations of which are well known. Additionally, our study was a single-center study and the sample size was relatively small. We also didn’t consider the possible combination of iLVNC with myocardial fibrosis.
Conclusions
In conclusion, DRA can be used to quantitatively analyze the strain of left ventricle in patients with iLVNC, and GRS is an earlier marker than LVEF of LV systolic dysfunction. Global strains can distinguish patients with iLVNC from healthy subjects with high diagnostic accuracy. Compared with FT, DRA has an excellent reproducibility in evaluating both global and segmental strain values in iLVNC patients and healthy population. Therefore, DRA can be a reliable tool to clinically assess global and segmental myocardial function of iLVNC patients.
Anzeige
Acknowledgements
The authors thank the study patients and volunteers for participation and the study personnel for their invaluable contribution.
Ethics approval and consent to participate
The study was approved by the Ethics Committee of Tongji Medical College, Huazhong University of Science and Technology. Written informed consent was obtained from all the participants.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Quantification of myocardial strain in patients with isolated left ventricular non-compaction and healthy subjects using deformable registration algorithm: comparison with feature tracking
verfasst von
Jia Liu Yumin Li Yue Cui Yukun Cao Sheng Yao Xiaoyue Zhou Jens Wetzl Wenjuan Zeng Heshui Shi