Skip to main content
Erschienen in: Radiological Physics and Technology 4/2017

08.09.2017

Quantitative analysis of effects of hemodynamic stress on temporal variations of cardiac phases in models of human carotid bulbs

verfasst von: Tatsunori Saho, Hideo Onishi

Erschienen in: Radiological Physics and Technology | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Abstract

In this study, we evaluated the hemodynamics of carotid artery models with carotid bulbs of various sizes using computational fluid dynamics (CFD) and the Fluent CFD software. The oscillatory shear index (OSI) and flow velocity distribution were evaluated in carotid models without a carotid bulb and with carotid bulbs of known geometry (major axis of 10, 11, 12, 13, and 14 mm; carotid bifurcation angle of 50°). Furthermore, the diameters of the common carotid artery, the external carotid artery, and the internal carotid artery were defined as 7.2, 4.0, and 4.5 mm, respectively. The accuracy of the CFD analysis in this study was verified using a flow phantom and measuring velocities with phase-contrast cine magnetic resonance imaging. The CFD parameters were defined as follows: rigid and no-slip walls, pulsatile flow, and 0 Pa of peripheral pressure. The OSI in the carotid bulb tended to show a high value during the expansion of the carotid bulb (maximum and minimum OSI: 0.11 ± 0.08 at d bulb: 14 mm; 0.0013 ± 0.0011 at no bulb), and the region of high OSI expanded with the expansion of the carotid bulb. The flow separated near the carotid bulb, and the flow deceleration expanded downstream as the size of the bulb increased. These findings suggest that the size of the carotid bulbs contributed to the OSI because the larger bulbs exhibited higher OSI values. The relation between the OSI and the carotid bulb size could serve as a risk indicator for atherosclerosis.
Literatur
1.
Zurück zum Zitat Harald CG, Lenette S. Quirijn B.MRI-based quantification of boundary conditions for computational fluid dynamics of stenosed human carotid arteries. J Biomech. 2010;43:2332–8.CrossRef Harald CG, Lenette S. Quirijn B.MRI-based quantification of boundary conditions for computational fluid dynamics of stenosed human carotid arteries. J Biomech. 2010;43:2332–8.CrossRef
2.
Zurück zum Zitat Sho E, Sho M, Singh TM, Xu C, Zarins CK, Masuda H. Blood flow decrease induces apoptosis of endothelial cells in previously dilated arteries resulting from chronic high blood flow. Arterioscler Thromb Vasc Biol. 2001;21(7):1139–45.CrossRefPubMed Sho E, Sho M, Singh TM, Xu C, Zarins CK, Masuda H. Blood flow decrease induces apoptosis of endothelial cells in previously dilated arteries resulting from chronic high blood flow. Arterioscler Thromb Vasc Biol. 2001;21(7):1139–45.CrossRefPubMed
3.
Zurück zum Zitat Iwase H, Himeno R, Kato Y. Development of a highly efficient system for the simulation of hemodynamics. Trans Jpn Soc Med Bioeng. 2006;44(3):428–34 (in Japanese). Iwase H, Himeno R, Kato Y. Development of a highly efficient system for the simulation of hemodynamics. Trans Jpn Soc Med Bioeng. 2006;44(3):428–34 (in Japanese).
4.
Zurück zum Zitat Cenic A, Nabavi DG, Craen RA, Gelb AW, Lee TY. A CT method to measure hemodynamics in brain tumors: validation and application of cerebral blood flow maps. Am J Neuroradiol. 2000;21(3):462–70.PubMed Cenic A, Nabavi DG, Craen RA, Gelb AW, Lee TY. A CT method to measure hemodynamics in brain tumors: validation and application of cerebral blood flow maps. Am J Neuroradiol. 2000;21(3):462–70.PubMed
5.
Zurück zum Zitat Isoda H, Hirano M, Takeda H, Kosugi T, Alley MT, Markl M, Pelc NJ, Sakahara H. Visualization of hemodynamics in a silicon aneurysm model using time-resolved, 3D, phase-contrast MRI. Am J Neuroradiol. 2006;27(5):1119–22.PubMed Isoda H, Hirano M, Takeda H, Kosugi T, Alley MT, Markl M, Pelc NJ, Sakahara H. Visualization of hemodynamics in a silicon aneurysm model using time-resolved, 3D, phase-contrast MRI. Am J Neuroradiol. 2006;27(5):1119–22.PubMed
6.
Zurück zum Zitat Kudo M. Multistep human hepatocarcinogenesis: correlation of imaging with pathology. J Gastroenterol. 2009;44(19):112–8.CrossRefPubMed Kudo M. Multistep human hepatocarcinogenesis: correlation of imaging with pathology. J Gastroenterol. 2009;44(19):112–8.CrossRefPubMed
7.
Zurück zum Zitat Maruyama C, Tsushima M, Kyotani S, Nakamori T, Fukushima S, Maruyama T. Cerebral blood flow velocity and serum fatty acid composition. Nutr Metab Cardiovasc Diseases. 1996;6(2):81–9. Maruyama C, Tsushima M, Kyotani S, Nakamori T, Fukushima S, Maruyama T. Cerebral blood flow velocity and serum fatty acid composition. Nutr Metab Cardiovasc Diseases. 1996;6(2):81–9.
8.
Zurück zum Zitat Sitzer M, Puac D, Buehler A, Steckel AD, Kegler S, Markus SH, Steinmetz H. Internal carotid artery angle of origin: a novel risk factor for early carotid atherosclerosis. Stroke. 2003;34:950–5.CrossRefPubMed Sitzer M, Puac D, Buehler A, Steckel AD, Kegler S, Markus SH, Steinmetz H. Internal carotid artery angle of origin: a novel risk factor for early carotid atherosclerosis. Stroke. 2003;34:950–5.CrossRefPubMed
9.
Zurück zum Zitat Kumar V, Cotran SR, Robbins LS. Section 10 vascular. In: Robbins Basic Pathology 7th edn. Philadelphia: Elsevier Saunders; 2003. pp. 409–54. Kumar V, Cotran SR, Robbins LS. Section 10 vascular. In: Robbins Basic Pathology 7th edn. Philadelphia: Elsevier Saunders; 2003. pp. 409–54.
10.
Zurück zum Zitat Vanka SP. A calculation procedure for three-dimensional steady recirculating flows using multigrid methods. Comput Methods Appl Mech Eng. 1986;55(3):321–38.CrossRef Vanka SP. A calculation procedure for three-dimensional steady recirculating flows using multigrid methods. Comput Methods Appl Mech Eng. 1986;55(3):321–38.CrossRef
11.
Zurück zum Zitat Sonesson B, Länne T, Vernersson E, Hansen F. Sex difference in the mechanical properties of the abdominal aorta in human beings. J Vascsurg. 1994;20(6):959–69. Sonesson B, Länne T, Vernersson E, Hansen F. Sex difference in the mechanical properties of the abdominal aorta in human beings. J Vascsurg. 1994;20(6):959–69.
12.
Zurück zum Zitat Ku DN, Giddens DP, Zarins CK, and Glagov S. Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. Arterioscler Thromb Vasc Biol. 1985; 5(3):293–2. Ku DN, Giddens DP, Zarins CK, and Glagov S. Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. Arterioscler Thromb Vasc Biol. 1985; 5(3):293–2.
13.
Zurück zum Zitat Saho T, Onishi H. Evaluation of the impact of carotid artery bifurcation angle on hemodynamics by use of computational fluid dynamics: a simulation and volunteer study. Radiol phys and technol. 2016;9(2):277–85.CrossRef Saho T, Onishi H. Evaluation of the impact of carotid artery bifurcation angle on hemodynamics by use of computational fluid dynamics: a simulation and volunteer study. Radiol phys and technol. 2016;9(2):277–85.CrossRef
14.
Zurück zum Zitat Lee SW, Antiga L, Spence JD, Steinman DA. Geometry of the carotid bifurcation predicts its exposure to disturbed flow. Stroke. 2008;39:2341–7.CrossRefPubMed Lee SW, Antiga L, Spence JD, Steinman DA. Geometry of the carotid bifurcation predicts its exposure to disturbed flow. Stroke. 2008;39:2341–7.CrossRefPubMed
15.
Zurück zum Zitat Markl M, Wegent F, Zech T, Bauer S, Strecker C, Schumacher M, Weiller C, Hennig J, Harloff A. In vivo wall shear stress distribution in the carotid artery effect of bifurcation geometry, internal carotid artery stenosis, and recanalization therapy. Circulation: cardiovasc. Imaging. 2010;3(6):647–55. Markl M, Wegent F, Zech T, Bauer S, Strecker C, Schumacher M, Weiller C, Hennig J, Harloff A. In vivo wall shear stress distribution in the carotid artery effect of bifurcation geometry, internal carotid artery stenosis, and recanalization therapy. Circulation: cardiovasc. Imaging. 2010;3(6):647–55.
16.
Zurück zum Zitat Grinberg L, Karniadakis GE. Outflow boundary conditions for arterial networks with multiple outlets. Ann Biomed Eng. 2008;36(9):1496–514.CrossRefPubMed Grinberg L, Karniadakis GE. Outflow boundary conditions for arterial networks with multiple outlets. Ann Biomed Eng. 2008;36(9):1496–514.CrossRefPubMed
17.
Zurück zum Zitat Reynolds O. An experimental investigation of the circumstances which determine whether the motion of water shall be direct or sinuous, and of the law of resistance in parallel channels. R Soc Lond. 1883;35(226):84–99.CrossRef Reynolds O. An experimental investigation of the circumstances which determine whether the motion of water shall be direct or sinuous, and of the law of resistance in parallel channels. R Soc Lond. 1883;35(226):84–99.CrossRef
18.
Zurück zum Zitat Sarpkaya T. Experimental determination of the critical Reynolds number for pulsating Poiseuille flow. J Fluids Eng. 1966;88(3):589–98. Sarpkaya T. Experimental determination of the critical Reynolds number for pulsating Poiseuille flow. J Fluids Eng. 1966;88(3):589–98.
19.
Zurück zum Zitat Frayne R, Steinman DA, Rutt BK, Ethier CR. Accuracy of MR phase contrast velocity measurements for unsteady flow. J Magn Reson Imaging. 1995;5(4):428–31.CrossRefPubMed Frayne R, Steinman DA, Rutt BK, Ethier CR. Accuracy of MR phase contrast velocity measurements for unsteady flow. J Magn Reson Imaging. 1995;5(4):428–31.CrossRefPubMed
20.
Zurück zum Zitat Marshall I, Zhao S, Papathanasopoulou P, Hoskins P, Xu XY. MRI and CFD studies of pulsatile flow in healthy and stenosed carotid bifurcation models. J Biomech. 2004;37(5):679–87.CrossRefPubMed Marshall I, Zhao S, Papathanasopoulou P, Hoskins P, Xu XY. MRI and CFD studies of pulsatile flow in healthy and stenosed carotid bifurcation models. J Biomech. 2004;37(5):679–87.CrossRefPubMed
21.
Zurück zum Zitat Saho T, Onishi H. Quantitative comparison of hemodynamics in simulated and 3D angiography models of cerebral aneurysms by use of computational fluid dynamics. Radiol Phys Technol. 2015;8(2):258–65.CrossRefPubMed Saho T, Onishi H. Quantitative comparison of hemodynamics in simulated and 3D angiography models of cerebral aneurysms by use of computational fluid dynamics. Radiol Phys Technol. 2015;8(2):258–65.CrossRefPubMed
22.
Zurück zum Zitat Maurits NM, Loots GE, Veldman AEP. The influence of vessel wall elasticity and peripheral resistance on the carotid artery flow wave form: a CFD model compared to in vivo ultrasound measurements. J Biomech. 2007;40(2):427–36.CrossRefPubMed Maurits NM, Loots GE, Veldman AEP. The influence of vessel wall elasticity and peripheral resistance on the carotid artery flow wave form: a CFD model compared to in vivo ultrasound measurements. J Biomech. 2007;40(2):427–36.CrossRefPubMed
Metadaten
Titel
Quantitative analysis of effects of hemodynamic stress on temporal variations of cardiac phases in models of human carotid bulbs
verfasst von
Tatsunori Saho
Hideo Onishi
Publikationsdatum
08.09.2017
Verlag
Springer Singapore
Erschienen in
Radiological Physics and Technology / Ausgabe 4/2017
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-017-0421-6

Weitere Artikel der Ausgabe 4/2017

Radiological Physics and Technology 4/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.