Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 3/2020

31.10.2018 | Original Article

Radial head arthroplasty for radial head fractures: a clinical and radiological comparison of monopolar and bipolar radial head arthroplasty at a mean follow-up of 6 years

verfasst von: Sebastian Mukka, Pontus Sjöholm, Nikolaos Perisynakis, Per Wahlström, Hans Rahme, Bakir Kadum

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 3/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to compare clinical and radiographic outcomes of bipolar and monopolar radial head arthroplasty in treatment of radial head fracture at a mean follow-up of 6 years.

Methods

A retrospective multicentre cohort study of 30 patients treated for unreconstructable radial head fractures. Patients were treated either with a cemented bipolar or an uncemented monopolar radial head arthroplasty. All patients included were evaluated with patient-rated outcome questionnaire, physical examination, and radiographic evaluation at a mean of 6 years (range, 2–12 years) postoperatively.

Results

There was no statistical difference in QuickDASH between the bipolar or monopolar groups. The majority of patients had no to little pain during rest. Neither flexion nor extension of the injured arm was significantly affected by the type of prosthesis. None of the patients in the bipolar group had any secondary surgery at the time of follow-up. In the monopolar group, four patients required removal of the arthroplasty. Signs of ulnohumeral degenerative changes were seen in the majority of patients in both groups (55% in the monopolar group, 92% in the bipolar group).

Conclusion

In this retrospective cohort study comparing a bipolar and a monopolar radial head arthroplasty for treatment of radial head fractures, we found comparable functional outcome but more revision procedures in the monopolar group at a mean follow-up of 6 years.
Literatur
2.
Zurück zum Zitat Herbertsson P, Josefsson PO, Hasserius R, Besjakov J, Nyqvist F, Karlsson MK. Fractures of the radial head and neck treated with radial head excision. J Bone Joint Surg Am. 2004;86-A(9):1925–30.CrossRef Herbertsson P, Josefsson PO, Hasserius R, Besjakov J, Nyqvist F, Karlsson MK. Fractures of the radial head and neck treated with radial head excision. J Bone Joint Surg Am. 2004;86-A(9):1925–30.CrossRef
3.
Zurück zum Zitat Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y. Comminuted fractures of the radial head. Comparison of resection and internal fixation. J Bone Joint Surg Am. 2005;87(1):76–84.CrossRef Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y. Comminuted fractures of the radial head. Comparison of resection and internal fixation. J Bone Joint Surg Am. 2005;87(1):76–84.CrossRef
5.
Zurück zum Zitat Moro JK1, Werier J, MacDermid JC, Patterson SD, King GJ. Arthroplasty with a metal radial head for unreconstructible fractures of the radial head. J Bone Joint Surg Am. 2011;83-A(8):1201–11.CrossRef Moro JK1, Werier J, MacDermid JC, Patterson SD, King GJ. Arthroplasty with a metal radial head for unreconstructible fractures of the radial head. J Bone Joint Surg Am. 2011;83-A(8):1201–11.CrossRef
7.
9.
Zurück zum Zitat Johnston GW. A follow-up of one hundred cases of fracture of the head of the radius with a review of the literature. Ulster Med J. 1962;31:51–6.PubMedPubMedCentral Johnston GW. A follow-up of one hundred cases of fracture of the head of the radius with a review of the literature. Ulster Med J. 1962;31:51–6.PubMedPubMedCentral
10.
Zurück zum Zitat Beaton DE, Wright JG, Katz JN, Upper Extremity Collaborative Group. Development of the QuickDASH: comparison of three item-reduction approaches. J Bone Joint Surg Am. 2005;87(5):1038–46.PubMed Beaton DE, Wright JG, Katz JN, Upper Extremity Collaborative Group. Development of the QuickDASH: comparison of three item-reduction approaches. J Bone Joint Surg Am. 2005;87(5):1038–46.PubMed
11.
Zurück zum Zitat Scott J, Huskisson EC. Graphic representation of pain. Pain. 1976;2(2):175–84.CrossRef Scott J, Huskisson EC. Graphic representation of pain. Pain. 1976;2(2):175–84.CrossRef
13.
Zurück zum Zitat Moro JK, Werier J, MacDermid JC, Patterson SD, King GJ. Arthroplasty with a metal radial head for unreconstructable fractures of the radial head. J Bone Joint Surg Am. 2001;83-A(8):1201–11.CrossRef Moro JK, Werier J, MacDermid JC, Patterson SD, King GJ. Arthroplasty with a metal radial head for unreconstructable fractures of the radial head. J Bone Joint Surg Am. 2001;83-A(8):1201–11.CrossRef
20.
Zurück zum Zitat Popovic N, Lemaire R, Georis P, Gillet P. Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface. J Bone Joint Surg Am. 2007;89(11):2469–76.PubMed Popovic N, Lemaire R, Georis P, Gillet P. Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface. J Bone Joint Surg Am. 2007;89(11):2469–76.PubMed
Metadaten
Titel
Radial head arthroplasty for radial head fractures: a clinical and radiological comparison of monopolar and bipolar radial head arthroplasty at a mean follow-up of 6 years
verfasst von
Sebastian Mukka
Pontus Sjöholm
Nikolaos Perisynakis
Per Wahlström
Hans Rahme
Bakir Kadum
Publikationsdatum
31.10.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 3/2020
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-018-1042-4

Weitere Artikel der Ausgabe 3/2020

European Journal of Trauma and Emergency Surgery 3/2020 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.