Cardiac catheterizations are among the X-ray procedures with the highest patient radiation dose and therefore are of great concern in pediatric settings. This study aimed to evaluate factors that influence variability of X-ray exposure in children with congenital heart diseases during cardiac catheterization. The study included 107 children who underwent either diagnostic (n = 46) or interventional (n = 61) procedures. A custom-made sheet for patient and procedural characteristics was designed. Data were collected, and different correlations were applied to determine factors that influence variability of X-ray exposure. The flouroscopy time (FT) differed significantly between the diagnostic (8.9 ± 6.3 min) and intervention (12.8 ± 9.98 min) groups (P = 0.032). The mean dose–area product (DAP) differed significantly between the two groups (3.775 ± 2.5 Gy/cm2 vs. 13.239 ± 15.4 Gy/cm2; P = 0.003). The highest DAP was during left anterior oblique (LAO) cranial 30° angulation (2.8 Gy/cm2/4 s cine). The mean cumulative dose (CD) was 0.053 Gy in diagnostic cases and 0.48 Gy in intervention cases. The effective dose was 5.97 ± 7.05 mSv for theraputic procedures compared with 3.42 ± 3.64 mSv for diagnostic procedures. The FT correlated significantly with both the DAP (r = 0.718; P < 0.001) and the CD (r = 0.701; P < 0.001). Other correlations were reported. An increasing number of therapeutic catheterization procedures are being performed for children. The justification for these procedures is evident because they avoid complicated surgery. However, the complexity of these procedures results in higher radiation exposures.
Literatur
1.
Zurück zum Zitat Ait-Ali L, Andreassi MG, Foffa I (2010) Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 96:269–274PubMedCrossRef Ait-Ali L, Andreassi MG, Foffa I (2010) Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 96:269–274PubMedCrossRef
2.
Zurück zum Zitat Allen HD, Driscoll DJ, Fricker FJ et al (1991) Guidelines for pediatric therapeutic cardiac catheterization: a statement for health professionals from the Committee on Congenital Cardiac Defects of the Council on Cardiovascular Disease in the Young, the American Heart Association. Circulation 84:2248–2258PubMed Allen HD, Driscoll DJ, Fricker FJ et al (1991) Guidelines for pediatric therapeutic cardiac catheterization: a statement for health professionals from the Committee on Congenital Cardiac Defects of the Council on Cardiovascular Disease in the Young, the American Heart Association. Circulation 84:2248–2258PubMed
3.
Zurück zum Zitat Bacher K, Bogaert E, Lapere R et al (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89PubMedCrossRef Bacher K, Bogaert E, Lapere R et al (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89PubMedCrossRef
4.
Zurück zum Zitat Baldazzi G, Corazza I, Rossi PL et al (2002) In vivo effectiveness of gadolinium filter for paediatric cardiac angiography in terms of image quality and radiation exposure. Phys Med 18:109–113 Baldazzi G, Corazza I, Rossi PL et al (2002) In vivo effectiveness of gadolinium filter for paediatric cardiac angiography in terms of image quality and radiation exposure. Phys Med 18:109–113
5.
Zurück zum Zitat Balter S (2006) Methods for measuring fluoroscopic skin dose. Pediatr Radiol 36(Suppl 2):136–140PubMedCrossRef Balter S (2006) Methods for measuring fluoroscopic skin dose. Pediatr Radiol 36(Suppl 2):136–140PubMedCrossRef
6.
Zurück zum Zitat Boothroyd A, McDonald E, Moores BM et al (1997) Radiation exposure to children during cardiac catheterization. Br J Radiol 70:180–185PubMed Boothroyd A, McDonald E, Moores BM et al (1997) Radiation exposure to children during cardiac catheterization. Br J Radiol 70:180–185PubMed
7.
Zurück zum Zitat Chida K, Saito H, Otani H et al (2006) Relationship between fluoroscopic time, dose–area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. AJR Am J Roentgenol 186:774–778PubMedCrossRef Chida K, Saito H, Otani H et al (2006) Relationship between fluoroscopic time, dose–area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. AJR Am J Roentgenol 186:774–778PubMedCrossRef
8.
Zurück zum Zitat Chida K, Ohno T, Kakizaki S et al (2010) Radiation dose to the pediatric cardiac catheterization and intervention patient. AJR Am J Roentgenol 195:1175–1179PubMedCrossRef Chida K, Ohno T, Kakizaki S et al (2010) Radiation dose to the pediatric cardiac catheterization and intervention patient. AJR Am J Roentgenol 195:1175–1179PubMedCrossRef
9.
Zurück zum Zitat Guibelalde E, Vano E, Gonzalez L et al (2003) Practical aspects for the evaluation of skin doses in interventional cardiology using a new slow film. Br J Radiol 76:332–336PubMedCrossRef Guibelalde E, Vano E, Gonzalez L et al (2003) Practical aspects for the evaluation of skin doses in interventional cardiology using a new slow film. Br J Radiol 76:332–336PubMedCrossRef
10.
Zurück zum Zitat Justino H (2006) The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose. Pediatr Radiol 36(Suppl 2):146–153PubMedCrossRef Justino H (2006) The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose. Pediatr Radiol 36(Suppl 2):146–153PubMedCrossRef
11.
Zurück zum Zitat Kuon E, Dahm J, Empen K et al (2004) Identification of less-irradiating tube angulations in invasive cardiology. J Am Coll Cardiol 44:1420–1428PubMedCrossRef Kuon E, Dahm J, Empen K et al (2004) Identification of less-irradiating tube angulations in invasive cardiology. J Am Coll Cardiol 44:1420–1428PubMedCrossRef
12.
Zurück zum Zitat Larrazet F, Dibie A, Philippe F et al (2003) Factors influencing fluoroscopy time and dose–area product values during ad hoc one-vessel percutaneous coronary angioplasty. Br J Radiol 76:473–477PubMedCrossRef Larrazet F, Dibie A, Philippe F et al (2003) Factors influencing fluoroscopy time and dose–area product values during ad hoc one-vessel percutaneous coronary angioplasty. Br J Radiol 76:473–477PubMedCrossRef
13.
14.
Zurück zum Zitat Li LB, Kai M, Kusama T (2001) Radiation exposure to patients during paediatric cardiac catheterization. Radiat Prot Dosimetry 94:323–327PubMed Li LB, Kai M, Kusama T (2001) Radiation exposure to patients during paediatric cardiac catheterization. Radiat Prot Dosimetry 94:323–327PubMed
15.
Zurück zum Zitat Mesbahi A, Aslanabadi N (2008) A study on patients’ radiation doses from interventional cardiac procedures in Tabriz, Iran. Radiat Protect Dosimetry 132:375–380CrossRef Mesbahi A, Aslanabadi N (2008) A study on patients’ radiation doses from interventional cardiac procedures in Tabriz, Iran. Radiat Protect Dosimetry 132:375–380CrossRef
16.
Zurück zum Zitat Miller DL, Balter S, Patricia E et al (2003) Radiation doses in interventional radiology procedures: The RAD-IR Study Part I: overall measures of dose. JVIR 14:711–727PubMedCrossRef Miller DL, Balter S, Patricia E et al (2003) Radiation doses in interventional radiology procedures: The RAD-IR Study Part I: overall measures of dose. JVIR 14:711–727PubMedCrossRef
17.
Zurück zum Zitat Onnasch DGW, Schroder FK, Fischer G et al (2007) Diagnostic reference levels and effective dose in paediatric cardiac catheterization. Br J Radiol 80:177–183PubMedCrossRef Onnasch DGW, Schroder FK, Fischer G et al (2007) Diagnostic reference levels and effective dose in paediatric cardiac catheterization. Br J Radiol 80:177–183PubMedCrossRef
18.
Zurück zum Zitat Rassow J, Schmaltz AA, Hentrich F et al (2000) Effective doses to patients from paediatric cardiac catheterization. Br J Radiol 73:172–183PubMed Rassow J, Schmaltz AA, Hentrich F et al (2000) Effective doses to patients from paediatric cardiac catheterization. Br J Radiol 73:172–183PubMed
19.
Zurück zum Zitat Ross RD, Joshi V, Carravallah DJ et al (1997) Reduced radiation during cardiac catheterization of infants using acquisition zoom technology. Am J Cardiol 79:691–693PubMedCrossRef Ross RD, Joshi V, Carravallah DJ et al (1997) Reduced radiation during cardiac catheterization of infants using acquisition zoom technology. Am J Cardiol 79:691–693PubMedCrossRef
20.
Zurück zum Zitat ICRP (1991) Recommendations of the International Commission on Radiological Protection. Publication 60. Pergamon Press, Oxford ICRP (1991) Recommendations of the International Commission on Radiological Protection. Publication 60. Pergamon Press, Oxford
21.
Zurück zum Zitat Schueler BA, Julsrud PR, Gray JE et al (1994) Radiation exposure and efficacy of exposure-reduction techniques during cardiac catheterization in children. Am J Roentgenol 162:173–177 Schueler BA, Julsrud PR, Gray JE et al (1994) Radiation exposure and efficacy of exposure-reduction techniques during cardiac catheterization in children. Am J Roentgenol 162:173–177
22.
Zurück zum Zitat Stratis A, Anthopoulos P, Gavaliatsis I et al (2009) Patient dose in cardiac radiology. Hellenic J Cardiol 50:17–25PubMed Stratis A, Anthopoulos P, Gavaliatsis I et al (2009) Patient dose in cardiac radiology. Hellenic J Cardiol 50:17–25PubMed
23.
Zurück zum Zitat Tsapaki V, Kottou S, Vano E et al (2003) Patient dose values in a dedicated Greek cardiac centre. Br J Radiol 76:726–730PubMedCrossRef Tsapaki V, Kottou S, Vano E et al (2003) Patient dose values in a dedicated Greek cardiac centre. Br J Radiol 76:726–730PubMedCrossRef
24.
Zurück zum Zitat Verghese GR, McElhinney DB, Bergersen L (2010) Characterization of high levels of radiation exposure in a large volume pediatric cardiac catheterization lab. J Am Coll Cardiol 55:A211. E1998. doi:10.1016/S0735-1097(10)61999-7 Verghese GR, McElhinney DB, Bergersen L (2010) Characterization of high levels of radiation exposure in a large volume pediatric cardiac catheterization lab. J Am Coll Cardiol 55:A211. E1998. doi:10.​1016/​S0735-1097(10)61999-7
25.
Zurück zum Zitat Watson L (1997) Radiation exposure during cardiology fellowship training. Health Phys 73:690–693PubMedCrossRef Watson L (1997) Radiation exposure during cardiology fellowship training. Health Phys 73:690–693PubMedCrossRef
26.
Zurück zum Zitat Žontar D, Kuhelj D, Škrk D et al (2010) Patient peak skin doses from cardiac interventional procedures. Radiat Prot Dosimetry 139:262–265PubMedCrossRef Žontar D, Kuhelj D, Škrk D et al (2010) Patient peak skin doses from cardiac interventional procedures. Radiat Prot Dosimetry 139:262–265PubMedCrossRef
Metadaten
Titel
Radiation Exposure in Children During the Current Era of Pediatric Cardiac Intervention
verfasst von
Maiy Hamdy El Sayed
Alaa Mahmoud Roushdy
Hala El Farghaly
Ahmad El Sherbini
Publikationsdatum
01.01.2012
Verlag
Springer-Verlag
Erschienen in
Pediatric Cardiology / Ausgabe 1/2012
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-011-0064-z

Weitere Artikel der Ausgabe 1/2012

Pediatric Cardiology 1/2012 Zur Ausgabe

From Other Journals

From Other Journals

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.