Skip to main content
Erschienen in: European Spine Journal 11/2017

06.02.2017 | Original Article

Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study

verfasst von: Ludovic Kaminski, V. Cordemans, O. Cartiaux, M. Van Cauter

Erschienen in: European Spine Journal | Ausgabe 11/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The goals of this paper are to assess the ionizing radiation exposure to the patients during thoracic and lumbar spinal fusion using a new intraoperative 3D imaging system and to evaluate the factors that could explain the variability in the observed doses.

Method

We retrospectively reviewed 97 patients who underwent posterior instrumented thoracic and/or lumbar spinal fusion from December 2013 to November 2014. Primary data were the total dose area product (total DAP, Gy cm2) and total skin dose (total SD, mGy). Influence of different variables (patient characteristics, surgical technique, and intraoperative imaging system parameters) that could influence patients’ exposure was analyzed.

Results

Radiation dose imparted to patients depended on four parameters including acquisition protocol, surgical technique, patient’s BMI and operative time. Minimally invasive surgery (MIS) resulted in twofold higher dose for patients, compared to open surgery. The use of low dose acquisition protocols reduced patient exposure by a factor three.

Conclusion

Patient exposure was highly variable. Four parameters were found to explain about 68% of its variance when using a multi-axis robotic C-arm system. MIS technique (with navigation or not) as well as the acquisition protocol dramatically increases the radiation dose for patients. These results show the necessity to develop specific strategies adapted to patients and surgical procedures.
Literatur
1.
4.
Zurück zum Zitat Perisinakis K, Theocharopoulos N, Damilakis J et al (2004) Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion. Spine 29:1555–1560CrossRefPubMed Perisinakis K, Theocharopoulos N, Damilakis J et al (2004) Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion. Spine 29:1555–1560CrossRefPubMed
6.
Zurück zum Zitat IEC (2010) Report 60601 medical electrical equipment—part 2-43: particular requirements for the safety of X-ray equipment for interventional procedures, 2nd edn. International Electrotechnical Commission, Geneva IEC (2010) Report 60601 medical electrical equipment—part 2-43: particular requirements for the safety of X-ray equipment for interventional procedures, 2nd edn. International Electrotechnical Commission, Geneva
11.
Zurück zum Zitat Harstall R, Heini PF, Mini RL, Orler R (2005) Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study. Spine 30:1893–1898CrossRefPubMed Harstall R, Heini PF, Mini RL, Orler R (2005) Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study. Spine 30:1893–1898CrossRefPubMed
14.
Zurück zum Zitat Raftopoulos C, Waterkeyn F, Fomekong E, Duprez T (2012) Percutaneous pedicle screw implantation for refractory low back pain: from manual 2D to fully robotic intraoperative 2D/3D fluoroscopy. Adv Tech Stand Neurosurg 38:75–93. doi:10.1007/978-3-7091-0676-1_4 CrossRefPubMed Raftopoulos C, Waterkeyn F, Fomekong E, Duprez T (2012) Percutaneous pedicle screw implantation for refractory low back pain: from manual 2D to fully robotic intraoperative 2D/3D fluoroscopy. Adv Tech Stand Neurosurg 38:75–93. doi:10.​1007/​978-3-7091-0676-1_​4 CrossRefPubMed
15.
Zurück zum Zitat Kraus M, Fischer E, Gebhard F, Richter PH (2015) Image quality and effective dose of a robotic flat panel 3D C-arm vs computed tomography. Int J Med Robot Comput Assist Surg MRCAS. doi:10.1002/rcs.1718 Kraus M, Fischer E, Gebhard F, Richter PH (2015) Image quality and effective dose of a robotic flat panel 3D C-arm vs computed tomography. Int J Med Robot Comput Assist Surg MRCAS. doi:10.​1002/​rcs.​1718
18.
Zurück zum Zitat Rampersaud YR, Foley KT, Shen AC et al (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine 25:2637–2645CrossRefPubMed Rampersaud YR, Foley KT, Shen AC et al (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine 25:2637–2645CrossRefPubMed
19.
Zurück zum Zitat Crawley MT, Rogers AT (2000) Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels. Br J Radiol 73:740–744CrossRefPubMed Crawley MT, Rogers AT (2000) Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels. Br J Radiol 73:740–744CrossRefPubMed
21.
22.
Zurück zum Zitat Erken HY, Burc H, Saka G et al (2013) Can radiation exposure to the surgeon be reduced with free-hand pedicle screw fixation technique in pediatric spinal deformity correction?: a prospective multi-center study. Spine. doi:10.1097/BRS.0000000000000172 Erken HY, Burc H, Saka G et al (2013) Can radiation exposure to the surgeon be reduced with free-hand pedicle screw fixation technique in pediatric spinal deformity correction?: a prospective multi-center study. Spine. doi:10.​1097/​BRS.​0000000000000172​
Metadaten
Titel
Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study
verfasst von
Ludovic Kaminski
V. Cordemans
O. Cartiaux
M. Van Cauter
Publikationsdatum
06.02.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 11/2017
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-017-4968-z

Weitere Artikel der Ausgabe 11/2017

European Spine Journal 11/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.