Skip to main content
main-content

01.06.2014 | Original Article | Ausgabe 6/2014

European Journal of Nuclear Medicine and Molecular Imaging 6/2014

Radiolabelled GLP-1 receptor antagonist binds to GLP-1 receptor-expressing human tissues

Zeitschrift:
European Journal of Nuclear Medicine and Molecular Imaging > Ausgabe 6/2014
Autoren:
Beatrice Waser, Jean Claude Reubi

Abstract

Purpose

Radiolabelled glucagon-like peptide 1 (GLP-1) receptor agonists have recently been shown to successfully image benign insulinomas in patients. For the somatostatin receptor targeting of tumours, however, it was recently reported that antagonist tracers were superior to agonist tracers. The present study therefore evaluated various forms of the 125iodinated-Bolton-Hunter (BH)-exendin(9–39) antagonist tracer for the in vitro visualization of GLP-1 receptor-expressing tissues in rats and humans and compared it with the agonist tracer 125I-GLP-1(7–36)amide.

Methods

Receptor autoradiography studies with 125I-GLP-1(7–36)amide agonist or 125I-BH-exendin(9–39) antagonist radioligands were performed in human and rat tissues.

Results

The antagonist 125I-BH-exendin(9–39) labelled at lysine 19 identifies all human and rat GLP-1 target tissues and GLP-1 receptor-expressing tumours. Binding is of high affinity and is comparable in all tested tissues in its binding properties with the agonist tracer 125I-GLP-1(7–36)amide. For comparison, 125I-BH-exendin(9–39) with the BH labelled at lysine 4 did identify the GLP-1 receptor in rat tissues but not in human tissues.

Conclusion

The GLP-1 receptor antagonist exendin(9–39) labelled with 125I-BH at lysine 19 is an excellent GLP-1 radioligand that identifies human and rat GLP-1 receptors in normal and tumoural tissues. It may therefore be the molecular basis to develop suitable GLP-1 receptor antagonist radioligands for in vivo imaging of GLP-1 receptor-expressing tissues in patients.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 6/2014

European Journal of Nuclear Medicine and Molecular Imaging 6/2014 Zur Ausgabe
  1. Sie können e.Med Radiologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  2. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.