Purpose

Accurate placement of medical devices is crucial in critical care to prevent severe complications. This study aims to evaluate radiology residents' proficiency in identifying four specific critical misplacements of medical devices using the Wisdom in Diagnostic Imaging Simulation (WIDI SIM).

Methods

A retrospective analysis was conducted on 1,102 responses from radiology residents who participated in the WIDI SIM between 2010 and 2022. The majority were first- and second-year residents from multiple institutions. The simulation presented four specific cases featuring misplacements of an endotracheal tube in the esophagus, an intrauterine device embedded in the myometrium, a peripherally inserted central catheter in the right internal jugular vein, and an umbilical venous catheter in the splenic vein. Residents provided free-text interpretations scored on a 0–10 scale by subspecialty radiologists. Errors were categorized as observational (failure to identify misplacement) or interpretive (misinterpretation of identified misplacement). Statistical analyses were performed using Kruskal–Wallis and Dunn's multiple comparisons tests.

Results

Across all cases, residents' average scores did not meet the acceptable standard of 7 points. Observational errors were predominant, indicating a failure to recognize these specific device misplacements. Effective report rates were low: 58% for the endotracheal tube case, 35% for the intrauterine device, 19% for the peripherally inserted central catheter, and 25% for the umbilical venous catheter. Significant performance improvements were observed between first- and second-year residents in three of the four cases (p-values ranging from < 0.0001 to 0.0238), but overall proficiency remained suboptimal even among senior residents.

Conclusion

This study reveals gaps in radiology residents' ability to identify these specific misplaced lines, tubes, and devices accurately. The consistent pattern of underperformance, primarily due to observational errors, suggests a need for targeted educational interventions to improve resident proficiency in this aspect of emergency radiology.
Literatur
12.
Metadaten
Titel
Radiology resident proficiency in identifying misplaced lines, tubes, and devices: a simulation-based study using WIDI SIM
verfasst von
Alexandria Iakovidis
Kevin Pierre
Abheek Raviprasad
Isabella Carvalho
Alina Zankevich
Roberta Slater
Christopher Sistrom
Otgonbayar Batmunh
Priya Sharma
Anthony Mancuso
Dhanashree Rajderkar
Publikationsdatum
06.12.2024
Verlag
Springer International Publishing
Erschienen in
Emergency Radiology
Print ISSN: 1070-3004
Elektronische ISSN: 1438-1435
DOI
https://doi.org/10.1007/s10140-024-02295-1

Neu im Fachgebiet Radiologie

KI-gestütztes Mammografiescreening überzeugt im Praxistest

Mit dem Einsatz künstlicher Intelligenz lässt sich die Detektionsrate im Mammografiescreening offenbar deutlich steigern. Mehr unnötige Zusatzuntersuchungen sind laut der Studie aus Deutschland nicht zu befürchten.

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Die elektronische Patientenakte kommt: Das sollten Sie jetzt wissen

Am 15. Januar geht die „ePA für alle“ zunächst in den Modellregionen an den Start. Doch schon bald soll sie in allen Praxen zum Einsatz kommen. Was ist jetzt zu tun? Was müssen Sie wissen? Wir geben in einem FAQ Antworten auf 21 Fragen.

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.