Skip to main content
Erschienen in: Journal of Artificial Organs 4/2018

02.06.2018 | Case Report

Rapid-onset plasma leakage of extracorporeal oxygenation membranes possibly due to hyperbilirubinemia

verfasst von: Yoshiko Kida, Shinichiro Ohshimo, Michihito Kyo, Yuko Tanabe, Kei Suzuki, Koji Hosokawa, Nobuaki Shime

Erschienen in: Journal of Artificial Organs | Ausgabe 4/2018

Einloggen, um Zugang zu erhalten

Abstract

Extracorporeal membrane oxygenation (ECMO) is an emerging tool for supporting cardiopulmonary function in patients with cardiorespiratory failure or arrest. The oxygenator of the ECMO circuit requires effective oxygenation and removal of carbon dioxide from the blood. Major problems that can occur with the oxygenator include plasma leakage, one of the late-onset serious complications necessitating device replacement. However, the rapid onset of plasma leakage is rare. We present a 1-year-old boy with acute respiratory failure due to Pneumocystis and Aspergillus pneumonia. He presented with tachypnea, tachycardia, and hypoxemia despite the ventilatory support, and was therefore placed on venoarterial ECMO with a drainage catheter from the right internal jugular vein (12 Fr) and a return catheter to the right internal carotid artery (10 Fr). Extracorporeal circulation was initiated at a blood flow of 1 L/min (145 mL/kg/min) and a sweep gas flow of 1 L/min with FiO2 of 0.7. Although he was successfully weaned from the venoarterial ECMO on day 15 with an improvement of cardiopulmonary function, he was later placed on venoarterial ECMO again because of the progression of pulmonary hypertension. Laboratory tests showed increased concentrations of hepatic enzymes and hyperbilirubinemia (total bilirubin 31.6 mg/dL). Six hours after starting ECMO circulation, plasma leakage from the oxygenator occurred. Although we replaced the oxygenator with a new one, the replacement showed plasma leakage after 6 h. Disassembly of the oxygenator revealed congestion from bilirubin in the membrane fibers. We described a case of repeated, rapid-onset plasma leakage after implementation of ECMO. Hyperbilirubinemia was likely associated with the plasma leakage of this patient.
Literatur
1.
Zurück zum Zitat Park TK, Yang JH, Jeon K, et al. Extracorporeal membrane oxygenation for refractory septic shock in adults. Eur J Cardiothorac Surg. 2015;47:e68–74.CrossRef Park TK, Yang JH, Jeon K, et al. Extracorporeal membrane oxygenation for refractory septic shock in adults. Eur J Cardiothorac Surg. 2015;47:e68–74.CrossRef
2.
Zurück zum Zitat Australia and New Zealand Extracorporeal Membrane Oxygenation (ANZ ECMO) Influenza Investigators, Davies A, Jones D, et al. Extracorporeal membrane oxygenation for 2009 influenza A(H1N1) acute respiratory distress syndrome. JAMA 2009;302:1888–95.CrossRef Australia and New Zealand Extracorporeal Membrane Oxygenation (ANZ ECMO) Influenza Investigators, Davies A, Jones D, et al. Extracorporeal membrane oxygenation for 2009 influenza A(H1N1) acute respiratory distress syndrome. JAMA 2009;302:1888–95.CrossRef
3.
Zurück zum Zitat Posluszny J, Rycus PT, Bartlett RH, et al. Outcome of adult respiratory failure patients receiving prolonged (≥ 14 days) ECMO. Ann Surg. 2016;263:573–81.CrossRef Posluszny J, Rycus PT, Bartlett RH, et al. Outcome of adult respiratory failure patients receiving prolonged (≥ 14 days) ECMO. Ann Surg. 2016;263:573–81.CrossRef
4.
Zurück zum Zitat Kind K, Reiss N, Knobl HJ, et al. Introduction of a new oxygenator including a tight fiber for long-term ECMO in infants. ASAIO J. 2006;52:217–8.CrossRef Kind K, Reiss N, Knobl HJ, et al. Introduction of a new oxygenator including a tight fiber for long-term ECMO in infants. ASAIO J. 2006;52:217–8.CrossRef
5.
Zurück zum Zitat Tatsumi E, Taenaka Y, Nakatani, et al. A VAD and novel high performance compact oxygenator for long-term ECMO with local anticoagulation. Trans Am Soc Artif Intern Organs. 1990;36:M480–3. Tatsumi E, Taenaka Y, Nakatani, et al. A VAD and novel high performance compact oxygenator for long-term ECMO with local anticoagulation. Trans Am Soc Artif Intern Organs. 1990;36:M480–3.
6.
Zurück zum Zitat Thiara AP, Hoel TN, Kristiansen F, et al. Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation. Perfusion. 2007;22:323–6.CrossRef Thiara AP, Hoel TN, Kristiansen F, et al. Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation. Perfusion. 2007;22:323–6.CrossRef
7.
Zurück zum Zitat Akasu H, Anazawa T. Development of a membrane oxygenator using novel polyolefin hollow fibers with blind-ended micropores. Jpn J Biomater. 1990;8:141–7. Akasu H, Anazawa T. Development of a membrane oxygenator using novel polyolefin hollow fibers with blind-ended micropores. Jpn J Biomater. 1990;8:141–7.
8.
Zurück zum Zitat Meyns B, Vercaemst L, Vandezande E, et al. Plasma leakage of oxygenators in ECMO depends on the type of oxygenator and on patient variables. Int J Artif Organs. 2005;28:30–4.CrossRef Meyns B, Vercaemst L, Vandezande E, et al. Plasma leakage of oxygenators in ECMO depends on the type of oxygenator and on patient variables. Int J Artif Organs. 2005;28:30–4.CrossRef
9.
Zurück zum Zitat Montoya JP, Shanley CJ, Merz SI, et al. Plasma leakage through microporous membranes. Role of phospholipids. ASAIO J. 1992;38:M399–405.CrossRef Montoya JP, Shanley CJ, Merz SI, et al. Plasma leakage through microporous membranes. Role of phospholipids. ASAIO J. 1992;38:M399–405.CrossRef
10.
Zurück zum Zitat Eash HJ, Jones HM, Hattler BG, et al. Evaluation of plasma resistant hollow fiber membranes for artificial lungs. ASAIO J. 2004;50:491–7.CrossRef Eash HJ, Jones HM, Hattler BG, et al. Evaluation of plasma resistant hollow fiber membranes for artificial lungs. ASAIO J. 2004;50:491–7.CrossRef
11.
Zurück zum Zitat Toomasian JM, Schreiner RJ, Meyer DE, et al. A polymethylpentene fiber gas exchanger for long-term extracorporeal life support. ASAIO J. 2005;51:390–7.CrossRef Toomasian JM, Schreiner RJ, Meyer DE, et al. A polymethylpentene fiber gas exchanger for long-term extracorporeal life support. ASAIO J. 2005;51:390–7.CrossRef
12.
Zurück zum Zitat Jacobsen J. Binding of bilirubin to human serum albumin—determination of the dissociation constants. FEBS Lett. 1969;5:112–4.CrossRef Jacobsen J. Binding of bilirubin to human serum albumin—determination of the dissociation constants. FEBS Lett. 1969;5:112–4.CrossRef
13.
Zurück zum Zitat Murrsy RK. Porphyrin and bile pigments. 24 ed Harper’s biochemistry. London: Appleton & Lange; 1996. Murrsy RK. Porphyrin and bile pigments. 24 ed Harper’s biochemistry. London: Appleton & Lange; 1996.
14.
Zurück zum Zitat Wildschut ED, Ahsman MJ, Allegaert K, et al. Determinants of drug absorption in different ECMO circuits. Intensive Care Med. 2010;36:2109–16.CrossRef Wildschut ED, Ahsman MJ, Allegaert K, et al. Determinants of drug absorption in different ECMO circuits. Intensive Care Med. 2010;36:2109–16.CrossRef
Metadaten
Titel
Rapid-onset plasma leakage of extracorporeal oxygenation membranes possibly due to hyperbilirubinemia
verfasst von
Yoshiko Kida
Shinichiro Ohshimo
Michihito Kyo
Yuko Tanabe
Kei Suzuki
Koji Hosokawa
Nobuaki Shime
Publikationsdatum
02.06.2018
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 4/2018
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-018-1051-4

Weitere Artikel der Ausgabe 4/2018

Journal of Artificial Organs 4/2018 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.