Skip to main content
Erschienen in: Abdominal Radiology 1/2020

07.11.2019 | Hepatobiliary

Rate of gadoxetate disodium (Eovist®) induced transient respiratory motion in children and young adults

verfasst von: Hunter Lanier, Andrew Wallace, Geetika Khanna

Erschienen in: Abdominal Radiology | Ausgabe 1/2020

Einloggen, um Zugang zu erhalten

Abstract

Background

Gadoxetate disodium (Eovist®, Bayer Healthcare, Wayne, NJ) is the preferred MR contrast agent for pediatric hepatobiliary imaging. A known limitation of this contrast agent is transient severe respiratory artifacts during arterial phase imaging, and some adult studies have raised caution against its use for evaluation of arterial enhancing lesions. The reported rate of transient severe breathing motion is 5–22% in adult studies. This study seeks to evaluate the frequency of transient severe respiratory motion secondary to gadoxetate disodium in a pediatric cohort.

Materials and methods

This is a retrospective, IRB-approved study with informed consent waiver. The radiology information system of a children’s hospital was searched to identify all MRI studies performed with gadoxetate disodium during January 2016–June 2018. Two readers independently evaluated all phases of a dynamic liver protocol for respiratory motion artifact on a 5-point scale (1 none, 2 mild, 3 moderate, 4 severe—still diagnostic, 5 extreme—not diagnostic). Average scores of the 2 readers for each phase were used for analyses. Transient severe respiratory motion was defined as an increase in artifact score of ≥ 1.5 from pre-contrast to arterial phase that returned to < 3 in equilibrium phase of imaging.

Results

The study cohort consisted of 140 cases (60% female), age range: 1 month–23 years (median 13 years). 102/140 scans were performed non-sedated. Mean respiratory motion score for each phase of scan for the entire cohort were pre-contrast: 2.23, arterial: 2.56, portal venous: 2.39, and equilibrium: 2.31. Transient severe respiratory motion was seen in 8 non-sedated cases and in 0 sedated cases. The rate of transient severe respiratory motion in a non-sedated pediatric cohort was estimated at 7.84% (8/102 cases).

Conclusion

The rate of transient severe respiratory motion in the non-sedated pediatric population is in the lower end of the range reported in adults. Transient severe respiratory motion is not observed in sedated patients.
Literatur
1.
Zurück zum Zitat Ayyala RS, Anupindi SA, Callahan MJ (2017) Practical use and pitfalls of hepatocyte-specific contrast agents (HSCAs) for pediatric hepatic and biliary magnetic resonance imaging. Abdom Radiol (NY) 42:502-520.CrossRef Ayyala RS, Anupindi SA, Callahan MJ (2017) Practical use and pitfalls of hepatocyte-specific contrast agents (HSCAs) for pediatric hepatic and biliary magnetic resonance imaging. Abdom Radiol (NY) 42:502-520.CrossRef
2.
Zurück zum Zitat Meyers AB, Towbin AJ, Serai S, et al (2011) Characterization of pediatric liver lesions with gadoxetate disodium. Pediatr Radiol 41:1183-1197.CrossRef Meyers AB, Towbin AJ, Serai S, et al (2011) Characterization of pediatric liver lesions with gadoxetate disodium. Pediatr Radiol 41:1183-1197.CrossRef
3.
Zurück zum Zitat Davenport MS, Viglianti BL, Al-Hawary MM, et al (2013) Comparison of acute transient dyspnea after intravenous administration of gadoxetate disodium and gadobenate dimeglumine: effect on arterial phase image quality. Radiology 266:452-461.CrossRef Davenport MS, Viglianti BL, Al-Hawary MM, et al (2013) Comparison of acute transient dyspnea after intravenous administration of gadoxetate disodium and gadobenate dimeglumine: effect on arterial phase image quality. Radiology 266:452-461.CrossRef
4.
Zurück zum Zitat Motosugi U (2015) Gadoxetic acid-induced acute transient dyspnea: the perspective of Japanese radiologists. Magn Reson Med Sci 14:163-164.CrossRef Motosugi U (2015) Gadoxetic acid-induced acute transient dyspnea: the perspective of Japanese radiologists. Magn Reson Med Sci 14:163-164.CrossRef
5.
Zurück zum Zitat Well L, Rausch VH, Adam G, et al (2017) Transient Severe Motion Artifact Related to Gadoxetate Disodium-Enhanced Liver MRI: Frequency and Risk Evaluation at a German Institution. Rofo 189:651-660.CrossRef Well L, Rausch VH, Adam G, et al (2017) Transient Severe Motion Artifact Related to Gadoxetate Disodium-Enhanced Liver MRI: Frequency and Risk Evaluation at a German Institution. Rofo 189:651-660.CrossRef
6.
Zurück zum Zitat Motosugi U, Bannas P, Bookwalter CA, et al (2016) An Investigation of Transient Severe Motion Related to Gadoxetic Acid-enhanced MR Imaging. Radiology 279:93-102.CrossRef Motosugi U, Bannas P, Bookwalter CA, et al (2016) An Investigation of Transient Severe Motion Related to Gadoxetic Acid-enhanced MR Imaging. Radiology 279:93-102.CrossRef
7.
Zurück zum Zitat Luetkens JA, Kupczyk PA, Doerner J, et al (2015) Respiratory motion artefacts in dynamic liver MRI: a comparison using gadoxetate disodium and gadobutrol. Eur Radiol 25:3207-3213.CrossRef Luetkens JA, Kupczyk PA, Doerner J, et al (2015) Respiratory motion artefacts in dynamic liver MRI: a comparison using gadoxetate disodium and gadobutrol. Eur Radiol 25:3207-3213.CrossRef
8.
Zurück zum Zitat Davenport MS, Caoili EM, Kaza RK, et al (2014) Matched within-patient cohort study of transient arterial phase respiratory motion-related artifact in MR imaging of the liver: gadoxetate disodium versus gadobenate dimeglumine. Radiology 272:123-131.CrossRef Davenport MS, Caoili EM, Kaza RK, et al (2014) Matched within-patient cohort study of transient arterial phase respiratory motion-related artifact in MR imaging of the liver: gadoxetate disodium versus gadobenate dimeglumine. Radiology 272:123-131.CrossRef
9.
Zurück zum Zitat Gilligan LA, Trout AT, Anton CG, et al (2019) Respiratory motion in children and young adults undergoing liver magnetic resonance imaging with intravenous gadoxetate disodium contrast material. Pediatr Radiol 49:1171-1176.CrossRef Gilligan LA, Trout AT, Anton CG, et al (2019) Respiratory motion in children and young adults undergoing liver magnetic resonance imaging with intravenous gadoxetate disodium contrast material. Pediatr Radiol 49:1171-1176.CrossRef
10.
Zurück zum Zitat McClellan TR, Motosugi U, Middleton MS, et al (2017) Intravenous Gadoxetate Disodium Administration Reduces Breath-holding Capacity in the Hepatic Arterial Phase: A Multi-Center Randomized Placebo-controlled Trial. Radiology 282:361-368.CrossRef McClellan TR, Motosugi U, Middleton MS, et al (2017) Intravenous Gadoxetate Disodium Administration Reduces Breath-holding Capacity in the Hepatic Arterial Phase: A Multi-Center Randomized Placebo-controlled Trial. Radiology 282:361-368.CrossRef
11.
Zurück zum Zitat Davenport MS, Bashir MR, Pietryga JA, et al (2014) Dose-toxicity relationship of gadoxetate disodium and transient severe respiratory motion artifact. AJR Am J Roentgenol 203:796-802.CrossRef Davenport MS, Bashir MR, Pietryga JA, et al (2014) Dose-toxicity relationship of gadoxetate disodium and transient severe respiratory motion artifact. AJR Am J Roentgenol 203:796-802.CrossRef
12.
Zurück zum Zitat Kim SY, Park SH, Wu EH, et al (2015) Transient respiratory motion artifact during arterial phase MRI with gadoxetate disodium: risk factor analyses. AJR Am J Roentgenol 204:1220-1227.CrossRef Kim SY, Park SH, Wu EH, et al (2015) Transient respiratory motion artifact during arterial phase MRI with gadoxetate disodium: risk factor analyses. AJR Am J Roentgenol 204:1220-1227.CrossRef
13.
Zurück zum Zitat Polanec SH, Bickel H, Baltzer PAT, et al (2017) Respiratory motion artifacts during arterial phase imaging with gadoxetic acid: Can the injection protocol minimize this drawback? J Magn Reson Imaging 46:1107-1114.CrossRef Polanec SH, Bickel H, Baltzer PAT, et al (2017) Respiratory motion artifacts during arterial phase imaging with gadoxetic acid: Can the injection protocol minimize this drawback? J Magn Reson Imaging 46:1107-1114.CrossRef
14.
Zurück zum Zitat Ringe KI, von Falck C, Raatschen HJ, et al (2018) Evaluation of transient respiratory motion artifact at gadoxetate disodium-enhanced MRI-Influence of different contrast agent application protocols. PLoS One 13:e0200887.CrossRef Ringe KI, von Falck C, Raatschen HJ, et al (2018) Evaluation of transient respiratory motion artifact at gadoxetate disodium-enhanced MRI-Influence of different contrast agent application protocols. PLoS One 13:e0200887.CrossRef
15.
Zurück zum Zitat Yoon JH, Lee JM, Yu MH, et al (2018) Evaluation of Transient Motion During Gadoxetic Acid-Enhanced Multiphasic Liver Magnetic Resonance Imaging Using Free-Breathing Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging. Invest Radiol 53:52-61.CrossRef Yoon JH, Lee JM, Yu MH, et al (2018) Evaluation of Transient Motion During Gadoxetic Acid-Enhanced Multiphasic Liver Magnetic Resonance Imaging Using Free-Breathing Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging. Invest Radiol 53:52-61.CrossRef
Metadaten
Titel
Rate of gadoxetate disodium (Eovist®) induced transient respiratory motion in children and young adults
verfasst von
Hunter Lanier
Andrew Wallace
Geetika Khanna
Publikationsdatum
07.11.2019
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 1/2020
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-019-02296-6

Weitere Artikel der Ausgabe 1/2020

Abdominal Radiology 1/2020 Zur Ausgabe

Classics in Abdominal Radiology

The Ring Sign

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.