Abstract

Radiation dose monitoring in medical imaging examination areas is mandatory for the reduction of patient radiation exposure. Recently, dose monitoring techniques that use digital imaging and communications in medicine (DICOM) dose structured reports (SR) have been introduced. The present paper discusses the setup of a radiation dose monitoring system based on DICOM data from university hospitals in Korea. This system utilizes the radiation dose data-archiving method of standard DICOM dose SR combined with a DICOM modality performed procedure step (MPPS). The analysis of dose data based on a method utilizing DICOM tag information is proposed herein. This method supports the display of dose data from non-dosimeter-attached X-ray equipment. This system tracks data from 62 pieces of equipment to analyze digital radiographic, mammographic, mobile radiographic, CT, PET-CT, angiographic, and fluorographic modalities.
Literatur
1.
Zurück zum Zitat Kim YH, Choi JH, Kim CK, Kim JM, Kim SS, Oh YW, Lee CY, Kang DH, Lee YB, Cho PK, Kim HC: Patient dose measurements in diagnostic radiology procedures in Korea. Radiat Prot Dosim 123(4):540–545, 2007CrossRef Kim YH, Choi JH, Kim CK, Kim JM, Kim SS, Oh YW, Lee CY, Kang DH, Lee YB, Cho PK, Kim HC: Patient dose measurements in diagnostic radiology procedures in Korea. Radiat Prot Dosim 123(4):540–545, 2007CrossRef
2.
Zurück zum Zitat International Commission on Radiological Protection. Managing patient dose in digital radiology, ICRP Publication 93. Ann. ICRP 34, 1–74, 2004 International Commission on Radiological Protection. Managing patient dose in digital radiology, ICRP Publication 93. Ann. ICRP 34, 1–74, 2004
3.
Zurück zum Zitat Vano E, Fernandez JM, Ten JI, Gonzalez L, Guibelalde E, Prieto C: Patient dosimetry and image quality in digital radiology from online audit of the X-ray system. Radiat Prot Dosim 117(1–3):199–203, 2005 Vano E, Fernandez JM, Ten JI, Gonzalez L, Guibelalde E, Prieto C: Patient dosimetry and image quality in digital radiology from online audit of the X-ray system. Radiat Prot Dosim 117(1–3):199–203, 2005
4.
Zurück zum Zitat Ng CK, Sun Z: Development of an online automatic diagnostic reference levels management system for digital radiography: a pilot experience. Comput Methods Prog Biomed 103:145–150, 2011CrossRef Ng CK, Sun Z: Development of an online automatic diagnostic reference levels management system for digital radiography: a pilot experience. Comput Methods Prog Biomed 103:145–150, 2011CrossRef
6.
Zurück zum Zitat United Nations Scientific Committee on the Effects of Atomic Radiation. UNSCEAR 2008 Report. Vol. I sources of ionizing radiation Annex A: Medical radiation exposures, 2010 United Nations Scientific Committee on the Effects of Atomic Radiation. UNSCEAR 2008 Report. Vol. I sources of ionizing radiation Annex A: Medical radiation exposures, 2010
7.
Zurück zum Zitat Rehani M, Frush D: Patient exposure tracking: The IAEA smart card project. Radiat Prot Dosim 147(1–2):314–316, 2011CrossRef Rehani M, Frush D: Patient exposure tracking: The IAEA smart card project. Radiat Prot Dosim 147(1–2):314–316, 2011CrossRef
8.
Zurück zum Zitat Sodickson A, Baeyens PF, Andriole KP, Prevedello LM, Nawfel RD, Hanson R, Khorasani RK: Recurrent CT, cumulative radiation exposure, associated radiation-induced cancer risks from CT of adults. Radiology 251(1):175–184, 2009CrossRefPubMed Sodickson A, Baeyens PF, Andriole KP, Prevedello LM, Nawfel RD, Hanson R, Khorasani RK: Recurrent CT, cumulative radiation exposure, associated radiation-induced cancer risks from CT of adults. Radiology 251(1):175–184, 2009CrossRefPubMed
9.
Zurück zum Zitat Vano E, Fernandez JM, Ten JI, Guibelalde E, Gonzalez L, Pedrosa CS: A real-time measurement and audit of radiation dose to patients undergoing computed radiography. Radiology 2251:283–288, 2002CrossRef Vano E, Fernandez JM, Ten JI, Guibelalde E, Gonzalez L, Pedrosa CS: A real-time measurement and audit of radiation dose to patients undergoing computed radiography. Radiology 2251:283–288, 2002CrossRef
10.
Zurück zum Zitat Bongartz G, Golding S, Jurik A, Leonardi M, van Meerten EP, Geleijns J, Jessen KA, Panzer W, Shrimpton PC, Tosi G: European Guidelines for Multislice Computed Tomography. European Commission, 2004 Bongartz G, Golding S, Jurik A, Leonardi M, van Meerten EP, Geleijns J, Jessen KA, Panzer W, Shrimpton PC, Tosi G: European Guidelines for Multislice Computed Tomography. European Commission, 2004
11.
Zurück zum Zitat Shrimpton PC, Hillier MC, Lewis MA, Dunn M: National survey of doses from CT in the UK: 2003. Br J Radiol 79:968–980, 2006CrossRefPubMed Shrimpton PC, Hillier MC, Lewis MA, Dunn M: National survey of doses from CT in the UK: 2003. Br J Radiol 79:968–980, 2006CrossRefPubMed
12.
Zurück zum Zitat Noumeir R: Benefits of the DICOM modality performed procedure step. J Digit Imaging 118(4):260–269, 2005CrossRef Noumeir R: Benefits of the DICOM modality performed procedure step. J Digit Imaging 118(4):260–269, 2005CrossRef
13.
Zurück zum Zitat Noumeir R: Benefits of the DICOM structured report. J Digit Imaging 119(4):295–306, 2006CrossRef Noumeir R: Benefits of the DICOM structured report. J Digit Imaging 119(4):295–306, 2006CrossRef
14.
Zurück zum Zitat McCollough C, Cody D, Edyvean S, Geise R, Gould B, Keat N, Huda W, Judy P, Kalender W, McNitt-Gray M, et al: The Measurement, Reporting, Management of Radiation Dose in CT. Rep AAPM Task Group 23:1–28, 2008 McCollough C, Cody D, Edyvean S, Geise R, Gould B, Keat N, Huda W, Judy P, Kalender W, McNitt-Gray M, et al: The Measurement, Reporting, Management of Radiation Dose in CT. Rep AAPM Task Group 23:1–28, 2008
15.
Zurück zum Zitat Charnock P, Moores BM, Wilde R: Establishing local and regional DRLs by means of electronic radiographical X-ray examination records. Radiat Prot Dosim 157(1):62–75, 2013CrossRef Charnock P, Moores BM, Wilde R: Establishing local and regional DRLs by means of electronic radiographical X-ray examination records. Radiat Prot Dosim 157(1):62–75, 2013CrossRef
16.
Zurück zum Zitat Moores BM, Charnock P, Ward M: Web-based tools for quality assurance and radiation protection in diagnostic radiology. Radiat Prot Dosim 139(1–3):422–429, 2010CrossRef Moores BM, Charnock P, Ward M: Web-based tools for quality assurance and radiation protection in diagnostic radiology. Radiat Prot Dosim 139(1–3):422–429, 2010CrossRef
17.
Zurück zum Zitat Cook TS, Zimmerman SL, Steingall SR, Maidment ADA, Kim WJ, Boonn WW: RADIANCE: an automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates. Radiographics 31:1833–1846, 2011CrossRefPubMed Cook TS, Zimmerman SL, Steingall SR, Maidment ADA, Kim WJ, Boonn WW: RADIANCE: an automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates. Radiographics 31:1833–1846, 2011CrossRefPubMed
18.
Zurück zum Zitat Edmonds I: R: calculation of patient skin dose from diagnostic X-ray procedures. Br J Radiol 57:733–734, 1984CrossRefPubMed Edmonds I: R: calculation of patient skin dose from diagnostic X-ray procedures. Br J Radiol 57:733–734, 1984CrossRefPubMed
Metadaten
Titel
Real-Time Patient Radiation Dose Monitoring System Used in a Large University Hospital
verfasst von
Jungsu Kim
Yongsu Yoon
Deoknam Seo
Soonmu Kwon
Jina Shim
Jungmin Kim
Publikationsdatum
25.04.2016
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 5/2016
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-016-9880-2

Weitere Artikel der Ausgabe 5/2016

Journal of Digital Imaging 5/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.