Skip to main content
Erschienen in: Wiener klinische Wochenschrift 13-14/2019

08.05.2019 | original article

Real-world extravascular lung water index measurements in critically ill patients

Pulse index continuous cardiac output measurements: time course analysis and association with clinical characteristics

verfasst von: Matthias Werner, Bernhard Wernly, Michael Lichtenauer, Marcus Franz, Bjoern Kabisch, Johanna M Muessig, Maryna Masyuk, Paul Christian Schulze, Uta C. Hoppe, Malte Kelm, Alexander Lauten, Christian Jung, M.D., PhD

Erschienen in: Wiener klinische Wochenschrift | Ausgabe 13-14/2019

Einloggen, um Zugang zu erhalten

Summary

Background

Pulse index continuous cardiac output (PiCCO) is used for hemodynamic assessment. This study describes real world extravascular lung water index (EVLWI) measurements at three time points and relates them to other hemodynamic parameters and mortality in critically ill patients admitted to a medical intensive care unit (ICU).

Methods

A total of 198 patients admitted to a tertiary medical university hospital between February 2004 and December 2010 were included in this retrospective analysis. Patients were admitted for various diseases such as sepsis (n = 22), myocardial infarction (n = 53), pulmonary embolism (n = 3), cardiopulmonary resuscitation (n = 15), acute heart failure (AHF; n = 21) and pneumonia (n = 25).

Results

Patients included in this analysis were severely ill as represented by the high simplified acute physiology score 2 (SAPS2, 42 ± 18) and acute physiology and chronic health evaluation score 2 (APACHE2‚ 22 ± 9). Real-world values at three time points are provided. Intra-ICU mortality rates did not differ between the EVLWI > 7 vs. the ELVWI < 7 groups (15% vs. 13%; p = 0.82) and no association between hemodynamic measurements obtained by PiCCO with long-term mortality could be shown.

Conclusion

There were no associations of any PiCCO measurements with mortality most probably due to selection bias towards severely ill patients. Future prospective studies with predefined inclusion criteria and treatment algorithms are necessary to evaluate the value of PiCCO for prediction of mortality against simple clinical tools such as jugular venous pressure, edema and auscultation.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283(9):447–51.CrossRef Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283(9):447–51.CrossRef
2.
Zurück zum Zitat Kirton OC, Calabrese RC, Staff I. Increasing use of less-invasive hemodynamic monitoring in 3 specialty surgical intensive care units: A 5-year experience at a tertiary medical center. J Intensive Care Med. 2015;30(1):30–6.CrossRef Kirton OC, Calabrese RC, Staff I. Increasing use of less-invasive hemodynamic monitoring in 3 specialty surgical intensive care units: A 5-year experience at a tertiary medical center. J Intensive Care Med. 2015;30(1):30–6.CrossRef
3.
Zurück zum Zitat Wernly B, Lichtenauer M, Franz M, Fritzenwanger M, Kabisch B, Figulla HR, et al. Pulse contour cardiac output monitoring in acute heart failure patients: Assessment of hemodynamic measurements. Wien Klin Wochenschr. 2016;128(23/24):864–9.CrossRef Wernly B, Lichtenauer M, Franz M, Fritzenwanger M, Kabisch B, Figulla HR, et al. Pulse contour cardiac output monitoring in acute heart failure patients: Assessment of hemodynamic measurements. Wien Klin Wochenschr. 2016;128(23/24):864–9.CrossRef
4.
Zurück zum Zitat Gassanov N, Caglayan E, Nia A, Erdmann E, Er F. Hemodynamic monitoring in the intensive care unit: Pulmonary artery catheter versus PiCCO. Dtsch Med Wochenschr. 2011;136(8):376–80.CrossRef Gassanov N, Caglayan E, Nia A, Erdmann E, Er F. Hemodynamic monitoring in the intensive care unit: Pulmonary artery catheter versus PiCCO. Dtsch Med Wochenschr. 2011;136(8):376–80.CrossRef
5.
Zurück zum Zitat Gassanov N, Caglayan E, Nia A, Erdmann E, Er F. The PiCCO catheter. Dtsch Med Wochenschr. 2010;135(46):2311–4.CrossRef Gassanov N, Caglayan E, Nia A, Erdmann E, Er F. The PiCCO catheter. Dtsch Med Wochenschr. 2010;135(46):2311–4.CrossRef
6.
Zurück zum Zitat Oren-Grinberg A. The PiCCO monitor. Int Anesthesiol Clin. 2010;48(1):57–85.CrossRef Oren-Grinberg A. The PiCCO monitor. Int Anesthesiol Clin. 2010;48(1):57–85.CrossRef
7.
Zurück zum Zitat Litton E, Morgan M. The PiCCO monitor: A review. Anaesth Intensive Care. 2012;40(3):393–409.CrossRef Litton E, Morgan M. The PiCCO monitor: A review. Anaesth Intensive Care. 2012;40(3):393–409.CrossRef
8.
Zurück zum Zitat Cottis R, Magee N, Higgins DJ. Haemodynamic monitoring with pulse-induced contour cardiac output (PiCCO) in critical care. Intensive Crit Care Nurs. 2003;19(5):301–7.CrossRef Cottis R, Magee N, Higgins DJ. Haemodynamic monitoring with pulse-induced contour cardiac output (PiCCO) in critical care. Intensive Crit Care Nurs. 2003;19(5):301–7.CrossRef
9.
Zurück zum Zitat Monnet X, Teboul JL. Transpulmonary thermodilution: Advantages and limits. Crit Care. 2017;21(1):147.CrossRef Monnet X, Teboul JL. Transpulmonary thermodilution: Advantages and limits. Crit Care. 2017;21(1):147.CrossRef
10.
Zurück zum Zitat Lichtwarck-Aschoff M, Zeravik J, Pfeiffer UJ. Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation. Intensive Care Med. 1992;18(3):142–7.CrossRef Lichtwarck-Aschoff M, Zeravik J, Pfeiffer UJ. Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation. Intensive Care Med. 1992;18(3):142–7.CrossRef
11.
Zurück zum Zitat Lemson J, de Boode WP, Hopman JC, Singh SK, van der Hoeven JG. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model. Pediatr Crit Care Med. 2008;9(3):313–9.CrossRef Lemson J, de Boode WP, Hopman JC, Singh SK, van der Hoeven JG. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model. Pediatr Crit Care Med. 2008;9(3):313–9.CrossRef
12.
Zurück zum Zitat Sakka SG, Reuter DA, Perel A. The transpulmonary thermodilution technique. J Clin Monit Comput. 2012;26(5):347–53.CrossRef Sakka SG, Reuter DA, Perel A. The transpulmonary thermodilution technique. J Clin Monit Comput. 2012;26(5):347–53.CrossRef
13.
Zurück zum Zitat Kuzkov VV, Kirov MY, Sovershaev MA, Kuklin VN, Suborov EV, Waerhaug K, et al. Extravascular lung water determined with single transpulmonary thermodilution correlates with the severity of sepsis-induced acute lung injury. Crit Care Med. 2006;34(6):1647–53.CrossRef Kuzkov VV, Kirov MY, Sovershaev MA, Kuklin VN, Suborov EV, Waerhaug K, et al. Extravascular lung water determined with single transpulmonary thermodilution correlates with the severity of sepsis-induced acute lung injury. Crit Care Med. 2006;34(6):1647–53.CrossRef
14.
Zurück zum Zitat Wang ZY, Bai Y. Extravascular lung water and pulmonary vascular permeability index may inadvertently delay the identification of acute respiratory distress syndrome. Crit Care. 2013;17(2):420.CrossRef Wang ZY, Bai Y. Extravascular lung water and pulmonary vascular permeability index may inadvertently delay the identification of acute respiratory distress syndrome. Crit Care. 2013;17(2):420.CrossRef
15.
Zurück zum Zitat Wang H, Cui N, Su L, Long Y, Wang X, Zhou X, et al. Prognostic value of extravascular lung water and its potential role in guiding fluid therapy in septic shock after initial resuscitation. J Crit Care. 2016;33:106–13.CrossRef Wang H, Cui N, Su L, Long Y, Wang X, Zhou X, et al. Prognostic value of extravascular lung water and its potential role in guiding fluid therapy in septic shock after initial resuscitation. J Crit Care. 2016;33:106–13.CrossRef
16.
Zurück zum Zitat Jozwiak M, Silva S, Persichini R, Anguel N, Osman D, Richard C, et al. Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome. Crit Care Med. 2013;41(2):472–80.CrossRef Jozwiak M, Silva S, Persichini R, Anguel N, Osman D, Richard C, et al. Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome. Crit Care Med. 2013;41(2):472–80.CrossRef
17.
Zurück zum Zitat Cotter G, Moshkovitz Y, Milovanov O, Salah A, Blatt A, Krakover R, et al. Acute heart failure: A novel approach to its pathogenesis and treatment. Eur J Heart Fail. 2002;4(3):227–34.CrossRef Cotter G, Moshkovitz Y, Milovanov O, Salah A, Blatt A, Krakover R, et al. Acute heart failure: A novel approach to its pathogenesis and treatment. Eur J Heart Fail. 2002;4(3):227–34.CrossRef
18.
Zurück zum Zitat Rabuel C, Mebazaa A. Septic shock: A heart story since the 1960s. Intensive Care Med. 2006;32(6):799–807.CrossRef Rabuel C, Mebazaa A. Septic shock: A heart story since the 1960s. Intensive Care Med. 2006;32(6):799–807.CrossRef
19.
Zurück zum Zitat Young JD. The heart and circulation in severe sepsis. Br J Anaesth. 2004;93(1):114–20.CrossRef Young JD. The heart and circulation in severe sepsis. Br J Anaesth. 2004;93(1):114–20.CrossRef
20.
Zurück zum Zitat Masyuk M, Wernly B, Lichtenauer M, Franz M, Kabisch B, Muessig JM, et al. Prognostic relevance of serum lactate kinetics in critically ill patients. Intensive Care Med. 2019;45(1):55–61.CrossRef Masyuk M, Wernly B, Lichtenauer M, Franz M, Kabisch B, Muessig JM, et al. Prognostic relevance of serum lactate kinetics in critically ill patients. Intensive Care Med. 2019;45(1):55–61.CrossRef
21.
Zurück zum Zitat Knaus WA, Zimmerman JE, Wagner DP, Draper EA, Lawrence DE. APACHE-acute physiology and chronic health evaluation: A physiologically based classification system. Crit Care Med. 1981;9(8):591–7.CrossRef Knaus WA, Zimmerman JE, Wagner DP, Draper EA, Lawrence DE. APACHE-acute physiology and chronic health evaluation: A physiologically based classification system. Crit Care Med. 1981;9(8):591–7.CrossRef
22.
Zurück zum Zitat Le Gall JR, Lemeshow S, Saulnier F. A new simplified acute physiology score (SAPS II) based on a European/North American multicenter study. JAMA. 1993;270(24):2957–63.CrossRef Le Gall JR, Lemeshow S, Saulnier F. A new simplified acute physiology score (SAPS II) based on a European/North American multicenter study. JAMA. 1993;270(24):2957–63.CrossRef
23.
Zurück zum Zitat Lee KS, Abbas AE, Khandheria BK, Lester SJ. Echocardiographic assessment of right heart hemodynamic parameters. J Am Soc Echocardiogr. 2007;20(6):773–82.CrossRef Lee KS, Abbas AE, Khandheria BK, Lester SJ. Echocardiographic assessment of right heart hemodynamic parameters. J Am Soc Echocardiogr. 2007;20(6):773–82.CrossRef
24.
Zurück zum Zitat Sivak ED, Richmond BJ, O’Donavan PB, Borkowski GP. Value of extravascular lung water measurement vs portable chest x‑ray in the management of pulmonary edema. Crit Care Med. 1983;11(7):498–501.CrossRef Sivak ED, Richmond BJ, O’Donavan PB, Borkowski GP. Value of extravascular lung water measurement vs portable chest x‑ray in the management of pulmonary edema. Crit Care Med. 1983;11(7):498–501.CrossRef
25.
Zurück zum Zitat Milne EN. Correlation of physiologic findings with chest roentgenology. Radiol Clin North Am. 1973;11(1):17–47.PubMed Milne EN. Correlation of physiologic findings with chest roentgenology. Radiol Clin North Am. 1973;11(1):17–47.PubMed
26.
Zurück zum Zitat Drazner MH, Rame JE, Stevenson LW, Dries DL. Prognostic importance of elevated jugular venous pressure and a third heart sound in patients with heart failure. N Engl J Med. 2001;345(8):574–81.CrossRef Drazner MH, Rame JE, Stevenson LW, Dries DL. Prognostic importance of elevated jugular venous pressure and a third heart sound in patients with heart failure. N Engl J Med. 2001;345(8):574–81.CrossRef
27.
Zurück zum Zitat Drazner MH, Rame JE, Dries DL. Third heart sound and elevated jugular venous pressure as markers of the subsequent development of heart failure in patients with asymptomatic left ventricular dysfunction. Am J Med. 2003;114(6):431–7.CrossRef Drazner MH, Rame JE, Dries DL. Third heart sound and elevated jugular venous pressure as markers of the subsequent development of heart failure in patients with asymptomatic left ventricular dysfunction. Am J Med. 2003;114(6):431–7.CrossRef
28.
Zurück zum Zitat Lindqvist P, Calcutteea A, Henein M. Echocardiography in the assessment of right heart function. Eur J Echocardiogr. 2008;9(2):225–34.PubMed Lindqvist P, Calcutteea A, Henein M. Echocardiography in the assessment of right heart function. Eur J Echocardiogr. 2008;9(2):225–34.PubMed
29.
Zurück zum Zitat Chaudhry SI, Wang Y, Concato J, Gill TM, Krumholz HM. Patterns of weight change preceding hospitalization for heart failure. Circulation. 2007;116(14):1549–54.CrossRef Chaudhry SI, Wang Y, Concato J, Gill TM, Krumholz HM. Patterns of weight change preceding hospitalization for heart failure. Circulation. 2007;116(14):1549–54.CrossRef
30.
Zurück zum Zitat Torgersen C, Schmittinger CA, Wagner S, Ulmer H, Takala J, Jakob SM, et al. Hemodynamic variables and mortality in cardiogenic shock: A retrospective cohort study. Crit Care. 2009;13(5):R157.CrossRef Torgersen C, Schmittinger CA, Wagner S, Ulmer H, Takala J, Jakob SM, et al. Hemodynamic variables and mortality in cardiogenic shock: A retrospective cohort study. Crit Care. 2009;13(5):R157.CrossRef
31.
Zurück zum Zitat Yang Y, Ma J, Zhao L. High central venous pressure is associated with acute kidney injury and mortality in patients underwent cardiopulmonary bypass surgery. J Crit Care. 2018;48:211–5.CrossRef Yang Y, Ma J, Zhao L. High central venous pressure is associated with acute kidney injury and mortality in patients underwent cardiopulmonary bypass surgery. J Crit Care. 2018;48:211–5.CrossRef
33.
Zurück zum Zitat Tan C, Rubenson D, Srivastava A, Mohan R, Smith MR, Billick K, et al. Left ventricular outflow tract velocity time integral outperforms ejection fraction and Doppler-derived cardiac output for predicting outcomes in a select advanced heart failure cohort. Cardiovasc Ultrasound. 2017;15(1):18.CrossRef Tan C, Rubenson D, Srivastava A, Mohan R, Smith MR, Billick K, et al. Left ventricular outflow tract velocity time integral outperforms ejection fraction and Doppler-derived cardiac output for predicting outcomes in a select advanced heart failure cohort. Cardiovasc Ultrasound. 2017;15(1):18.CrossRef
34.
Zurück zum Zitat Sekulic AD, Trpkovic SV, Pavlovic AP, Marinkovic OM, Ilic AN. Scoring systems in assessing survival of critically ill ICU patients. Med Sci Monit. 2015;21:2621–9.CrossRef Sekulic AD, Trpkovic SV, Pavlovic AP, Marinkovic OM, Ilic AN. Scoring systems in assessing survival of critically ill ICU patients. Med Sci Monit. 2015;21:2621–9.CrossRef
35.
Zurück zum Zitat Houwink AP, Rijkenberg S, Bosman RJ, van der Voort PH. The association between lactate, mean arterial pressure, central venous oxygen saturation and peripheral temperature and mortality in severe sepsis: A retrospective cohort analysis. Crit Care. 2016;20:56.CrossRef Houwink AP, Rijkenberg S, Bosman RJ, van der Voort PH. The association between lactate, mean arterial pressure, central venous oxygen saturation and peripheral temperature and mortality in severe sepsis: A retrospective cohort analysis. Crit Care. 2016;20:56.CrossRef
36.
Zurück zum Zitat Brivet FG, Kleinknecht DJ, Loirat P, Landais PJ. Acute renal failure in intensive care units—Causes, outcome, and prognostic factors of hospital mortality; a prospective, multicenter study. French Study Group on Acute Renal Failure. Crit Care Med. 1996;24(2):192–8.CrossRef Brivet FG, Kleinknecht DJ, Loirat P, Landais PJ. Acute renal failure in intensive care units—Causes, outcome, and prognostic factors of hospital mortality; a prospective, multicenter study. French Study Group on Acute Renal Failure. Crit Care Med. 1996;24(2):192–8.CrossRef
37.
Zurück zum Zitat Cardoso FS, Marcelino P, Bagulho L, Karvellas CJ. Acute liver failure: An up-to-date approach. J Crit Care. 2017;39:25–30.CrossRef Cardoso FS, Marcelino P, Bagulho L, Karvellas CJ. Acute liver failure: An up-to-date approach. J Crit Care. 2017;39:25–30.CrossRef
38.
Zurück zum Zitat Fincke R, Hochman JS, Lowe AM, Menon V, Slater JN, Webb JG, et al. Cardiac power is the strongest hemodynamic correlate of mortality in cardiogenic shock: A report from the SHOCK trial registry. J Am Coll Cardiol. 2004;44(2):340–8.CrossRef Fincke R, Hochman JS, Lowe AM, Menon V, Slater JN, Webb JG, et al. Cardiac power is the strongest hemodynamic correlate of mortality in cardiogenic shock: A report from the SHOCK trial registry. J Am Coll Cardiol. 2004;44(2):340–8.CrossRef
39.
Zurück zum Zitat Mutoh T, Kazumata K, Ajiki M, Ushikoshi S, Terasaka S. Goal-directed fluid management by bedside transpulmonary hemodynamic monitoring after subarachnoid hemorrhage. Stroke. 2007;38(12):3218–24.CrossRef Mutoh T, Kazumata K, Ajiki M, Ushikoshi S, Terasaka S. Goal-directed fluid management by bedside transpulmonary hemodynamic monitoring after subarachnoid hemorrhage. Stroke. 2007;38(12):3218–24.CrossRef
40.
Zurück zum Zitat Ritter S, Rudiger A, Maggiorini M. Transpulmonary thermodilution-derived cardiac function index identifies cardiac dysfunction in acute heart failure and septic patients: An observational study. Crit Care. 2009;13(4):R133.CrossRef Ritter S, Rudiger A, Maggiorini M. Transpulmonary thermodilution-derived cardiac function index identifies cardiac dysfunction in acute heart failure and septic patients: An observational study. Crit Care. 2009;13(4):R133.CrossRef
Metadaten
Titel
Real-world extravascular lung water index measurements in critically ill patients
Pulse index continuous cardiac output measurements: time course analysis and association with clinical characteristics
verfasst von
Matthias Werner
Bernhard Wernly
Michael Lichtenauer
Marcus Franz
Bjoern Kabisch
Johanna M Muessig
Maryna Masyuk
Paul Christian Schulze
Uta C. Hoppe
Malte Kelm
Alexander Lauten
Christian Jung, M.D., PhD
Publikationsdatum
08.05.2019
Verlag
Springer Vienna
Erschienen in
Wiener klinische Wochenschrift / Ausgabe 13-14/2019
Print ISSN: 0043-5325
Elektronische ISSN: 1613-7671
DOI
https://doi.org/10.1007/s00508-019-1501-x

Weitere Artikel der Ausgabe 13-14/2019

Wiener klinische Wochenschrift 13-14/2019 Zur Ausgabe

mitteilungen der gesellschaft der ärzte in wien

Veranstaltungstipps

MUW researcher of the month

MUW researcher of the month

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.