Skip to main content
Erschienen in: Cardiovascular Ultrasound 1/2013

Open Access 01.12.2013 | Research

Reference values for fetal tissue velocity imaging and a new approach to evaluate fetal myocardial function

verfasst von: Nina NE Elmstedt, Jonas JJ Johnson, Britta BL Lind, Kjerstin KFW Ferm-Widlund, Lotta LH Herling, Magnus MW Westgren, Lars-Åke LAB Brodin

Erschienen in: Cardiovascular Ultrasound | Ausgabe 1/2013

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Objectives

Myocardial function can be evaluated using color-coded tissue velocity imaging (TVI) to analyze the longitudinal myocardial velocity profile, and by expressing the motion of the atrioventricular plane during a cardiac cycle as coordinated events in the cardiac state diagram (CSD). The objective of this study was to establish gestational age specific reference values for fetal TVI measurements and to introduce the CSD as a potential aid in fetal myocardial evaluation.

Methods

TVI recordings from 125 healthy fetuses, at 18 to 42 weeks of gestation, were performed with the transducer perpendicular to the apex to provide a four-chamber view. The myocardial velocity data was extracted from the basal segment of septum as well as the left and right ventricular free wall for subsequent offline analysis.

Results

During a cardiac cycle the longitudinal peak velocities of septum increased with gestational age, as did the peak velocities of the left and right ventricular free wall, except for the peak velocity of post ejection. The duration of rapid filling and atrial contraction increased during pregnancy while the duration of post ejection decreased. The duration of pre ejection and ventricular ejection did not change significantly with gestational age.

Conclusion

Evaluating fetal systolic and diastolic performance using TVI together with CSD could contribute to increase the knowledge and understanding of fetal myocardial function and dysfunction. The pre and post ejection phases are the variables most likely to indicate fetuses with abnormal myocardial function.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1476-7120-11-29) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

NE, BL, LÅB and MW participated in the design of the study and the interpretation of data, as well as revised the maniscript. NE performed the offline measurements, statistical analysis and drafted the manuscript. JJ performed the software development, defined the timing of the mechanical events during a cardiac cycle, participated in the interpretation of data and revised the manuscript. KFW and LH performed the ultrasound image acquisition ande revised the manuscript. All authors read and approved the final manuscript.

Introduction

In the progression of fetal hemodynamic adaptation, the assessment of fetal myocardial function could be of crucial importance when evaluating fetuses at risk or suffering from intrauterine hypoxia [1, 2]. Although this has been common knowledge since many years, myocardial performance is typically evaluated by specialists in fetal cardiology, and methods to perform these evaluations are regarded as rather cumbersome and have consequently not been introduced in clinical practice. Furthermore, most studies on myocardial performance have until now been based on conventional Doppler, which measures global cardiac function restricted to flow measurements [37]. Color-coded tissue velocity imaging (TVI) offers quantitative measurements of regional myocardial function, and can potentially provide more sensitive and thus earlier indications of myocardial dysfunction. TVI enables adequate temporal resolution (>200 frames/s) [8] unlike speckle tracking (<80 frames/s) [9] and doesn’t overestimate true motion or alter offline gain settings in contrast to spectral Doppler [10]. Velocity can also be measured simultaneously in the different myocardial walls during the same cardiac cycle.
The cardiac state diagram (CSD) is a new visualization tool for the pumping and regulating function of the heart [11] that provides quantitative analysis of the timing of mechanical events in the cardiac cycle without the need of a concurrent ECG signal. Based on the hypothesis that the heart’s pumping and regulating function acts according to the Dynamic Adaptive Piston Pump (DAPP) [12], this tool presents comparative data of systolic and diastolic performance and improve separate assessment thereof - providing a more complete overview of the cardiac function [13]. The different time intervals during a cardiac cycle are displayed in a circular diagram, a visual interpretation of which can be seen in Figure 1. To be able to understand fetal cardiac physiology it is essential to understand fetal myocardial function and development throughout gestation. Thus, the general objective of this study was to establish normal reference ranges and gestational age related changes of fetal TVI measurements and to introduce the CSD as a potential aid in fetal myocardial evaluation.

Methods

The study included 125 fetuses, at a gestational age of 18 to 42 weeks, all referred to the Centre of Fetal Medicine at the Karolinska University Hospital Huddinge during 2009–2012. Gestational age was determined according to ultrasound in the 16-18th week of gestation. Characteristics of the study population are presented in Table 1. All women enrolled were healthy, and experienced a normal singleton pregnancy. Twin pregnancies and in vitro fertilization (IVF) were excluded. The study was approved by the Regional Ethics committee of Stockholm, Sweden, and all subjects gave their informed consent to participate.
Table 1
Characteristics of the studied fetal population
Number of subjects
Sex female/male
GA
GA at delivery
MA
BW
125
62/63
30 (18–42)
40 (38–42)
30 (19–46)
3525 (2538–4815)
GA, Gestational age (weeks); MA, Maternal age (years) and BW, Birth weight (g) presented as median (range).
Tissue Doppler echocardiography data was obtained with a GE Vivid-i equipment (GE Vingmed, Norway), using a 3S-RS transducer. All recordings were performed with the transducer perpendicular to the apex, providing a view of the fetal myocardium equivalent to an apical four-chamber view. The 2D and TVI sector widths were minimized to obtain a frame rate > 200 frames/s (median 209 frames/s, range 200 to 273), which is necessary for adequate reconstruction of TVI data for the fetal myocardium [8]. The recordings were performed by an experienced midwife and stored as cine loops of five to 10 consecutive cardiac cycles for offline analysis using EchoPAC (GE Vingmed, Norway) and GHLab (Gripping Heart AB, Sweden). Longitudinal myocardial tissue velocity was extracted from fixed region of interest (ROI) in the basal segment of septum as well as the left and right ventricular free wall during the end of systole in the same cardiac cycle, apical to the atrioventricular plane (AV-piston), as illustrated in Figure 2. The ROI was set between 1–3 mm, depending on image characteristics such as thickness of the myocardial wall and interference from valve motion or fetal/maternal movement. According to DAPP technology the term AV-piston was used instead of the conventional term AV-plane, better describing the cardiac mechanics.
The cardiac cycle was divided into six main phases: atrial contraction, pre ejection, ventricular ejection, post ejection, rapid filling and slow filling. Systole was defined as pre ejection and ventricular ejection, while diastole was defined as post ejection, rapid filling, atrial contraction and slow filling. The time intervals were measured according to the changes from static to dynamic work, based on the motion shifts of the AV-piston, in compliance with DAPP technology. This makes identification of the time intervals possible without a concurrent ECG signal. The measuring points are slightly different from prevalent measuring points, as the phases of pre and post ejection are defined according to heart mechanics unlike the isovolumetric contraction and relaxation, identified based on the zero axis crossing points of the velocity curve. This is usually carried out in combination with reference points in the ECG signal, and the occasional anatomical M-mode image, in order to acquire a precise electrophysiological timing. This is not possible when screening the fetus, which precludes accurate timing of the mechanical events. The phases are displayed in Figure 1 and the time intervals defined as follows.
Atrial contraction begins with an elevation of the AV-piston, during which tension forces are created in the ventricular walls. When these tension forces become greater than the contraction forces in the atria the AV-piston start to move down towards the apex and the atrial contraction phase ends. This ventricular reshaping together with the vortex formations created in the flow behind the atrioventricular valves initiate the closure of the atrioventricular valves and is the beginning of pre ejection - the transition phase (volume to tension) between atrial contraction and ventricular ejection. During pre ejection the atrioventricular valves close and the interventricular pressure rises. This phase ends with a powerful tension increase as the acceleration of blood starts to initiate the opening of the semilunar valves and ventricular ejection begins. The interventricular pressure exceeds the pressure in the aorta and the pulmonary artery, causing the semilunar valves to open and blood to be ejected into the systematic circulation. Ventricular ejection ends when there is no outflow from the semilunar valves and they are about to close just before a backflow into the ventricles is generated. This initiates post ejection – the transition phase (tension to volume) between ventricular ejection and rapid filling. During post ejection the ventricular myocardium starts to relax. The forces of the backflow overcome the tension in the muscles and the ventricular volumes increase. Rapid filling starts as the atrioventricular valves are about to open and a reverse volumetric reshaping process begins. At that time the interventricular pressure drops, muscle tension decrease and the AV-piston returns to its neutral position by the inflow controlled hydraulic return. This phase ends as soon as the dynamic and resilient forces outside the heart have ceased and slow filling begins. Static and dynamic forces generated by blood flow into the heart are now the only forces left to keep the heart in an expanded position. Once the slow filling phase ends a new cardiac cycle begins.
The data set was analyzed using SPSS (PASW Statistics 18). Linear regression analyses were displayed in scatter plots as well as in tables presented as mean values with 95% confidence interval. For the variables of insignificant change, the results were presented as median values within a range.

Results

The myocardial time intervals and velocities measured during a cardiac cycle, as well as the Tei index and the e’/a’ ratio, extracted from septum as well as the left and right ventricular free wall, are presented in Table 2. The variables that were observed to significantly change throughout pregnancy are further described with gestational age specific mean values and confidence intervals in Table 3.
Table 2
The mean values from 18 weeks of gestation to term for the myocardial time intervals and velocities during a cardiac cycle, as well as the Tei index and e’/a’ ratio
Variable
Abbreviation
Septum
Left ventricular free wall
Right ventricular fee wall
Time intervals (ms)
    
Atrial contraction
P1
67 / 83 (r = 0,344)
61 / 84 (r = 0,317)
81 / 94 (r = 0,214)
Pre ejection
P2
23 (11–56)
24 (9–54)
26 (0–76)
Ventricular ejection
P3
180 (95–277)
184 (126–245)
182 (95–303)
Post ejection
P4
63 / 41 (r = 0,441)
61 / 36 (r = 0,353)
49 (17–87)
Rapid filling
P5
71 / 109 (r = 0,403)
74 / 100 (r = 0,393)
72 / 98 (r = 0,416)
Slow filling
P6
8 / 110 (r = 0,287 )
4 (0–44)
3 (0–36)
Tei index
 
0,42 (0,13 – 0,64)
0,41 (0,17 – 0,85)
0,41 (0,14 – 0,89)
Peak velocities (cm/s)
    
Atrial contraction
a’
−2,4 / –3,9 (r = 0,387)
−1,9 / –4,0 (r = 0,375)
−4,0 / −6,2 (r = 0,421)
Pre ejection (pos)
pre’pos
0,4 / 1,1 (r = 0,427)
0,3 / 2,0 (r = 0,489)
0,7 / 3,0 (r = 0,553)
Pre ejection (neg)
pre’neg
−0,1 (−2,8 – 1,5)
−0,1 (−1,3 – 0,3)
−0,1 (−1,3 – 3,7)
Ventricular ejection
s’
1,5 / 2,9 (r = 0,566)
1,1/ 2,8 (r = 0,512)
1,7 / 4,7 (r = 0,599)
Post ejection (neg)
post’neg
−0,3 (−1,8 – 1,0)
−0,3 (−4,2 – o,9)
−0,4 (−6,9 – 0,8)
Post ejection (pos)
post’pos
0,3 / 1,0 (r = 0,395)
0,3 (−0,8 – 2,8)
0,4 (−5,0 – 2,7)
Rapid filling
e’
−1,3 / −3,3 (r = 0,509)
−1,2 / −3,1 (r = 0,528)
−1,4 / −4,6 (r = 0,527)
Slow filling
p6’
−0,5 / −1,3 (r = 0,373)
−0,7 (−4,9 – 2,8)
−1,9 (−6,7 – 3,5)
e’/a’
 
0,54 / 0,84 (r = 0,316)
0,56 / 0,84 (r = 0,358)
0,45 / 0,79 (r = 0,438)
The variables that significantly changed throughout gestation are presented as mean values, where the nominator represents the mean value at 18 weeks of gestation and the denominator represents the mean value at term. The r-value is Pearson’s correlation coefficient, the correlation to advancing gestational age. The variables that did not show any significant change with gestational age are presented as median values within a range.
Table 3
Gestational age specific reference values for fetal myocardial TVI measurements of longitudinal velocities and time intervals during a cardiac cycle
GA (weeks)
18–21
22–25
26–29
30–33
34–37
38–42
Subjects
20
20
20
20
20
25
 
Time intervals (ms) mean (95% CI)
Septum
P1
66 (62 – 70)
72 (68 – 76)
80 (70 – 89)
80 (72 – 89)
82 (74 – 90)
83 (78 – 89)
P4
58 (53 – 64)
54 (50 – 59)
55 (48 – 61)
53 (47 – 59)
49 (44 – 55)
41 (34 – 49)
P5
69 (57 – 82)
74 (68 – 79)
81 (69 – 93)
80 (67 – 93)
82 (71 – 92)
110 (96 – 123)
P6
8 (5–11)
5 (3–7)
5 (3–7)
4 (3–6)
4 (2–6)
3 (1 – 5)
Left ventricular free wall
     
P1
66 (62 – 70)
69 (66 – 71)
75 (68 – 82)
74 (67 – 82)
78 (72 – 84)
81 (77 – 86)
P4
62 (57 – 67)
55 (50 – 61)
57 (51 – 64)
45 (40 – 51)
43 (36 – 51)
36 (30 – 41)
P5
67 (56 – 77)
74 (67 – 81)
80 (71 – 89)
81 (73 – 89)
85 (75 – 95)
100 (86 – 114)
Right ventricular free wall
     
P1
78 (73 – 83)
87 (82 – 93)
88 (78 – 98)
94 (83 – 103)
94 (82 – 106)
96 (85 – 108)
P5
61 (51 – 71)
70 (63 – 76)
72 (60 – 85)
69 (60 – 77)
92 (77 – 107)
99 (83 – 114)
 
Peak velocities (cm/s) mean (95% CI)
Septum
a’
–2,5 (1,3 – 2,8)
–2,9 (2,5 – 3,2)
–3,2 (2,7 – 3,7)
–3,7 (3,3 – 4,0)
–3,4 (2,8 – 3,9)
–3,8 (3,3 – 4,3)
pre’pos
0,4 (0,3 – 0,6)
0,4 (0,2 – 0,6)
0,3 (0,2 – 0,5)
0,7 (0,4 – 0,9)
0,7 (0,4 – 0,9)
1,1 (0,8 – 1,4)
s’
1,6 (1,3 – 1,8)
2,0 (1,8 – 2,3)
2,0 (1,8 – 2,2)
2,3 (2,2 – 2,4)
2,6 (2,2 – 3,0)
2,9 (2,6 – 3,3)
post’pos
0,2 (0,1 – 0,3)
0,2 (0,0 – 0,3)
0,4 (0,2 – 0,5)
0,4 (0,2 – 0,7)
0,2 (0,0 – 0,4)
1,0 (0,7 – 1,3)
e’
–1,4 (1,2 – 1,6)
–2,2 (1,9 – 2,4)
–2,5 (2,1 – 2,8)
–2,7 (2,5 – 3,0)
–2,8 (2,3 – 3,2)
–3,2 (2,6 – 3,8)
p6’
–0,5 (0,8 – 0,2)
–0,7(1,0 – 0,4)
–0,8 (1,1 – 0,5)
–1,6 (1,9 – 1,2)
–1,2 (1,6 – 0,8)
–1,3 (1,7 – 0,9)
Lefts ventricular free wall
     
a’
–2,0 (1,7 – 2,2)
–3,1 (2,8 – 3,5)
–3,9 (3,2–4,6)
–4,4 (3,3 – 5,0)
–3,4 (2,9 – 3,8)
–3,9 (3,2 – 4,6)
pre’pos
0,3 (0,2 – 0,4)
0,5 (0,3 – 0,7)
0,6 (0,3 – 0,8)
0,8 (0,4 – 1,2)
1,2 (0,8 – 1,6)
1,9 (1,1 – 2,7)
s’
1,3 (1,1 – 1,5)
1,9 (1,7 – 2,2)
2,3 (2,0 – 2,7)
2,4 (2,2 – 2,6)
2,9 (2,4 – 3,4)
2,9 (2,4 – 3,3)
e’
–1,3 (1,1 – 1,6)
–2,1 (1,7 – 2,4)
–2,6 (2,1 – 3,1)
–3,6 (3,1 – 4,1)
–3,2 (2,8 – 3,6)
–3,0 (2,6 – 3,5)
Right ventricular free wall
     
a’
–4,4 (3,8 – 5,0)
–5,2 (4,8 – 5,7)
–5,6 (4,9 – 6,4)
–6,5 (5,9 – 7,1)
–6,7 (5,8 – 7,7)
–6,0 (5,3 – 6,7)
pre’pos
0,6 (0,4 – 0,9)
1,0 (0,7 – 1,4)
1,3 (0,8 – 1,8)
1,3 (0,8 – 1,9)
2,2 (1,5 – 2,9)
3,0 (2,2 – 3,8)
s’
1,8 (1,5 – 2,2)
2,7 (2,3 – 3,1)
3,1(2,6 – 3,7)
3,4 (3,1 – 3,7)
4,2(3,6 – 4,7)
4,5 (3,6 – 5,4)
e’
–1,7 (1,1 – 2,2)
–3,3 (2,8 – 3,7)
–4.2 (3,5 – 4,9)
–4,9 (4,3 – 5,5)
–5,6 (4,6 – 6,5)
–4,5 (3,6 – 5,3)
The results from the linear regression analyses are presented as mean values with 95% confidence intervals. P1 and a’, atrial contraction; pre’ pos , pre ejection; s’, ventricular ejection; P4 and post’ pos , post ejection; P5 and e’, rapid filling; P6 and p6’, slow filling.
Fetal heart rate decreased from a mean 147 bpm (range 133 to 164) at 18 weeks of gestation to a mean 137 bpm (range 117 to 142) at term (r = 0.401), equivalent to a prolonged duration of a fetal cardiac cycle with about 30 ms throughout gestation. This corresponded to an increase in diastolic duration, as the duration of systole did not vary significantly with gestational age, either during pre ejection or ventricular ejection. Figure 3 shows two CSD generated from septum from the average of 10 fetuses at 18 weeks of gestation and 10 fetuses at term, respectively, displaying the different time intervals during a cardiac cycle. During diastole, the duration of atrial contraction and rapid filling were prolonged while the duration of post ejection was shortened. The linear regression plots for the measurements of these phases, made from septum and the left and right ventricular free wall, are displayed over gestational age in Figure 4(a), (b) and (c). Adherent gestational age specific mean values and confidence intervals are stated in Table 3.
Multiple regression analysis showed that a combination of HR and gestational age enhanced the correlations for the duration of artial contraction (r = 0,461) and rapid filling (r = 0,516). However, no significant relationship was observed between HR and the post ejection phase or the systolic durations. Sex was not decisive for any of the measured variables even though HR was observed to be significantly higher for the female fetus up until 30 weeks of gestation.
During a cardiac cycle the longitudinal peak velocities of septum showed a linear increase with gestational age, as did the peak velocities of the left and right ventricular free wall, except for the peak velocity of post ejection (post’). Figure 4(d), (e), (f) show the increase throughout gestation for the peak velocity of ventricular ejection (s’), rapid filling (e’) and atrial contraction (a’) extracted from septum as well as the left and right ventricular free wall. Adherent gestational age specific mean values and confidence intervals are stated in Table 3. The velocity during pre and post ejection show a biphasic motion pattern, but single phase movements may occur as well (more common during pre ejection). However, the negative peak velocities of these phases did not change significantly throughout gestation.
The peak velocities of the right ventricular free wall were higher compared to the peak velocities of septum or the left ventricular free wall, and showed a higher rate of change with gestational age during ventricular ejection and rapid filling. This corresponded to a more prominent increase of the e’/a’ ratio observed in the right ventricular free wall compared to the left ventricular free wall and septum. The displacement of the AV-piston, i.e. the distance covered during ventricular ejection, also showed a linear increase more prominent in the right ventricular free wall as pregnancy advanced, as can be seen in Figure 5. The mean value of the left ventricle (septum and the left ventricular free wall) increased from 1 to 3 mm (r = 0,616), and that of the right ventricular free wall increased from 2 to 5 mm (r = 0,534). The velocity and displacement measurements extracted from the right ventricular free wall consequently displayed a wider distribution compared to septum and the left ventricular free wall.
We could confirm the feasibility and potential use of the new technique, previously demonstrated in a study of non ST-elevation myocardial infarction in adults [11] and a study of experimental hypoxia in fetal sheep [14].

Discussion

The objective of this study was to establish gestational age specific reference data for TVI measurements of the fetal myocardium. These data also reveal some new information regarding prenatal cardiac function as this study is the first to assess myocardial mechanics during fetal development by evaluating the different time intervals during a cardiac cycle according to the motion shifts of the AV-piston. The finding that the post ejection phase, measured from septum and the left ventricular free wall, decreased with gestational age, might reflect lactate dependent myocardial performance. During this phase the ventricular myocardium starts to relax, which paradoxically is an energy consuming process, caused by the repolarization process of the heart muscle cells, and consequently this phase will be very sensitive to low oxygen levels. In accordance adults exhibit a prolongation of post ejection during exercise and controlled hypoxia resulting in lactecaemia [11]. In a recent study on fetal lamb we also observed a prolongation of post ejection at controlled hypoxia [14], suggesting an adaptive mechanism of the fetal heart to resolve to a more immature state at relative hypoxia. In the right ventricular free wall no significant change of the post ejection phase was observed throughout gestation, which is consistent with the absence of this phase for the corresponding cardiac wall in adults. The prolongation of the rapid filling phase throughout gestation is most likely due to an increase in size and volume. However, the maturational rate of e’ was more prominent, which in accordance with recent findings [15] indicate an improvement in active relaxation as pregnancy advances.
In concurrence with previous studies [2, 1520] we observed that all peak velocities during the cardiac cycle were higher in the right ventricular free wall compared to septum and the left ventricular free wall - consistent with right ventricular dominance. As can be seen in Figure 4, the right ventricle also showed a greater stroke length compared to the left. We could also confirm the gestational increase in fetal myocardial velocities despite a maturational fall in fetal heart rate [7], and the increase of the e’/a’ ratio, corresponding to a redistribution from A-wave towards E-wave dominance with gestational age. The higher ventricular filling velocities confirming the active Frank-Starling mechanism in the fetal heart [7], which is particularly apparent during fetal arrhythmias [21]. The maturational rate of s’ and e’ was higher in the right ventricular free wall compared to the left ventricular free wall and septum, implying that the differential loading of the ventricles does influence the measures of myocardial maturation, unlike Gardiner et al. previously suggested [7]. Sex was not decisive for any of the measured variables even though HR was observed to be significantly higher for the female fetus up until 30 weeks of gestation. Unlike Bilardo et al [22]., we did not observe a relationship between sex and e’, however, multiple regression analysis showed that a combination of HR and gestational age enhanced the correlation for the rapid filling phase. This would imply that an increased HR might affect the ability to measure e’ accurately.
Previous studies that used spectral Doppler reported higher peak velocities compared to the present results [2, 19, 20, 23], which is in agreement with the reported overestimation of velocity using this technique [10]. Also the e’/a’ ratio was higher in these studies, indicating a larger overestimation of e’. Using TVI, different studies have reported varying results [1518, 24]. The measurements of e’ and a’ in the present study were in better compliance with previously reported results than the measurements of s’. An explanation for the observed discrepancies could be the angle dependency of the velocity measurements [25] or the placement of the ROI [25, 26]. However, all aforementioned studies state acceptable reproducibility of their measurements. Which is also valid for the measurements made in this study, where reproducibility as well as intra- and inter-observer variability has been demonstrated to be acceptable in the controlled clinical setting [27], and may indicate that the equipment used is not interchangeable - previously demonstrated in both adult [28] and fetal [29] echocardiography. This implies that one should need to establish separate reference materials when measuring amplitudes of the myocardial velocity curve depending on which ultrasound system and is being used. A study demonstrating normal values and age related changes of pre’ also suggest that pre’ and post’ are more reliable than s’, as s’ has shown to be preload and afterload dependent [23, 30, 31]. Even though we demonstrate less distribution for pre’, the peak velocity during such a short time interval is easy to miss. Further studies are needed in order to confirm the reasons for the discrepancies, and to establish whether this also applies for the timing of the mechanical events during a cardiac cycle.
As long as the timing of myocardial events can be represented accurately, time intervals could be more robust measurements than myocardial velocities as these measurements are less angle dependant and less influenced by tethering effects. Furthermore, time intervals have been described as markers of cardiac performance, where the myocardial performance index or Tei index, reflecting the relationship between the transition phases (pre and post ejection) and ventricular ejection, has been evaluated as a marker of fetal cardiac dysfunction [3234]. These time intervals were in the present study shown to be independent of heart rate within the studied heart rate interval. However, there was no gestational age related change of this index, despite a maturational shortening of the post ejection phase, which implies that the Tei index might not be as sensitive. Traditionally this index has been calculated from Doppler derived blood flow measurements, which are not comparable to tissue velocity measurements [35], and these measures should not be used interchangeably.
The transition phases mirror the hearts mechanical function and have been shown to be lactate sensitive markers for asphyxia and metabolic acidosis [14, 36]. Lactate is a metabolite in anaerobic metabolism and reflects tissue hypoxia. Determination of lactate in blood from the fetus’s scalp during labor has been studied extensively and comparative studies of pH have shown that lactate analysis has similar or better predictive properties compared with pH analysis in the identification of short term neonatal morbidity [37, 38]. Thus non-invasive methods to determine the fetal lactate status is of great potential value in the area of fetal monitoring.
The timing of mechanical events has hitherto been difficult to ensure without a simultaneous ECG signal. To make the analysis of TVI measurements easier and more effective we introduced the CSD as a potential aid in fetal monitoring. Using this method we measure the time intervals according to the changes from static to dynamic work based on the DAPP-technology, and thus no longer require a simultaneous ECG signal. This means that in the future we can potentially provide a fully automated evaluation of the longitudinal myocardial velocity profile. Hypothetically this method could give early indications of myocardial dysfunction that should be beneficial in many patient groups where fetal myocardial function is affected and facilitate detection of risk pregnancies as well as aid in the assessment before and after intrauterine fetal therapy.
The provided reference material demonstrated the feasibility of the technique and that the measurements are sensitive enough to yield insight into maturational changes in myocardial function, which provides a foundation that will enable further investigations and potentially allow identification of fetuses with myocardial dysfunction.

Acknowledgements

This work was supported by the Swedish Heart-Lung Foundation.
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

NE, BL, LÅB and MW participated in the design of the study and the interpretation of data, as well as revised the maniscript. NE performed the offline measurements, statistical analysis and drafted the manuscript. JJ performed the software development, defined the timing of the mechanical events during a cardiac cycle, participated in the interpretation of data and revised the manuscript. KFW and LH performed the ultrasound image acquisition ande revised the manuscript. All authors read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat Oudijk MA, et al.: The effects of intrapartum hypoxia on the fetal QT interval. BJOG. 2004, 111: 656-660. 10.1111/j.1471-0528.2004.00178.x.CrossRefPubMed Oudijk MA, et al.: The effects of intrapartum hypoxia on the fetal QT interval. BJOG. 2004, 111: 656-660. 10.1111/j.1471-0528.2004.00178.x.CrossRefPubMed
2.
Zurück zum Zitat Chan LY, et al.: Reference charts of gestation-specific tissue doppler imaging indices of systolic and diastolic functions in the normal fetal heart. Am Heart J. 2005, 150: 750-755. 10.1016/j.ahj.2004.12.028.CrossRefPubMed Chan LY, et al.: Reference charts of gestation-specific tissue doppler imaging indices of systolic and diastolic functions in the normal fetal heart. Am Heart J. 2005, 150: 750-755. 10.1016/j.ahj.2004.12.028.CrossRefPubMed
3.
Zurück zum Zitat Larsen LU, et al.: Strain rate derived from color doppler myocardial imaging for assessment of fetal cardiac function. Ultrasound Obstet Gynecol. 2006, 27: 210-213. 10.1002/uog.2669.CrossRefPubMed Larsen LU, et al.: Strain rate derived from color doppler myocardial imaging for assessment of fetal cardiac function. Ultrasound Obstet Gynecol. 2006, 27: 210-213. 10.1002/uog.2669.CrossRefPubMed
4.
Zurück zum Zitat Crispi F, et al.: Feasibility and reproducibility of a standard protocol for 2D speckle tracking and tissue doppler-based strain and strain rate analysis of the fetal heart. Fetal Diagn Ther. 2012, 32: 96-108. 10.1159/000337329.CrossRefPubMed Crispi F, et al.: Feasibility and reproducibility of a standard protocol for 2D speckle tracking and tissue doppler-based strain and strain rate analysis of the fetal heart. Fetal Diagn Ther. 2012, 32: 96-108. 10.1159/000337329.CrossRefPubMed
5.
Zurück zum Zitat Perk G, Tunick PA, Kronzon I: Non-doppler two-dimensional strain imaging by echocardiography–from technical considerations to clinical applications. J Am Soc Echocardiogr. 2007, 20: 234-243. 10.1016/j.echo.2006.08.023.CrossRefPubMed Perk G, Tunick PA, Kronzon I: Non-doppler two-dimensional strain imaging by echocardiography–from technical considerations to clinical applications. J Am Soc Echocardiogr. 2007, 20: 234-243. 10.1016/j.echo.2006.08.023.CrossRefPubMed
6.
Zurück zum Zitat Tutschek B, Zimmermann T, Buck T, Bender HG: Fetal tissue doppler echocardiography: detection rates of cardiac structures and quantitative assessment of the fetal heart. Ultrasound Obstet Gynecol. 2003, 21: 26-32. 10.1002/uog.8.CrossRefPubMed Tutschek B, Zimmermann T, Buck T, Bender HG: Fetal tissue doppler echocardiography: detection rates of cardiac structures and quantitative assessment of the fetal heart. Ultrasound Obstet Gynecol. 2003, 21: 26-32. 10.1002/uog.8.CrossRefPubMed
7.
Zurück zum Zitat Gardiner HM, et al.: Myocardial tissue doppler and long axis function in the fetal heart. Int J Cardiol. 2006, 113: 39-47. 10.1016/j.ijcard.2005.10.029.CrossRefPubMed Gardiner HM, et al.: Myocardial tissue doppler and long axis function in the fetal heart. Int J Cardiol. 2006, 113: 39-47. 10.1016/j.ijcard.2005.10.029.CrossRefPubMed
8.
Zurück zum Zitat Elmstedt N, Lind B, Ferm-Widlund K, Westgren M, Brodin LA: Temporal frequency requirements for tissue velocity imaging of the fetal heart. Ultrasound Obstet Gynecol. 2011, 38: 413-417. 10.1002/uog.8872.CrossRefPubMed Elmstedt N, Lind B, Ferm-Widlund K, Westgren M, Brodin LA: Temporal frequency requirements for tissue velocity imaging of the fetal heart. Ultrasound Obstet Gynecol. 2011, 38: 413-417. 10.1002/uog.8872.CrossRefPubMed
9.
Zurück zum Zitat Matsui H, Germanakis I, Kulinskaya E, Gardiner HM: Temporal and spatial performance of vector velocity imaging in the human fetal heart. Ultrasound Obstet Gynecol. 2011, 37: 150-157. 10.1002/uog.8815.CrossRefPubMed Matsui H, Germanakis I, Kulinskaya E, Gardiner HM: Temporal and spatial performance of vector velocity imaging in the human fetal heart. Ultrasound Obstet Gynecol. 2011, 37: 150-157. 10.1002/uog.8815.CrossRefPubMed
10.
Zurück zum Zitat Manouras A, Shahgaldi K, Winter R, Nowak J, Brodin LA: Comparison between colour-coded and spectral tissue doppler measurements of systolic and diastolic myocardial velocities: effect of temporal filtering and offline gain setting. Eur J Echocardiogr. 2009, 10: 406-413. 10.1093/ejechocard/jen298.CrossRefPubMed Manouras A, Shahgaldi K, Winter R, Nowak J, Brodin LA: Comparison between colour-coded and spectral tissue doppler measurements of systolic and diastolic myocardial velocities: effect of temporal filtering and offline gain setting. Eur J Echocardiogr. 2009, 10: 406-413. 10.1093/ejechocard/jen298.CrossRefPubMed
11.
Zurück zum Zitat Larsson M, et al.: State diagrams of the heart–a new approach to describing cardiac mechanics. Cardiovasc Ultrasound. 2009, 7: 22-10.1186/1476-7120-7-22.CrossRefPubMedPubMedCentral Larsson M, et al.: State diagrams of the heart–a new approach to describing cardiac mechanics. Cardiovasc Ultrasound. 2009, 7: 22-10.1186/1476-7120-7-22.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Lundback S: Cardiac pumping and function of the ventricular septum. Acta Physiol Scand Suppl. 1986, 550: 1-101.PubMed Lundback S: Cardiac pumping and function of the ventricular septum. Acta Physiol Scand Suppl. 1986, 550: 1-101.PubMed
13.
Zurück zum Zitat Lundbäck S: State machine interface system. WO 2007/142594 2007 Lundbäck S: State machine interface system. WO 2007/142594 2007
14.
Zurück zum Zitat Wågström E, et al.: The cardiac state diagram as a novel approach for evaluation of Pre- and post ejection phases of the cardiac cycle in asphyxiated fetal lambs. Ultrasound Med Biol. 2013, in press Wågström E, et al.: The cardiac state diagram as a novel approach for evaluation of Pre- and post ejection phases of the cardiac cycle in asphyxiated fetal lambs. Ultrasound Med Biol. 2013, in press
15.
Zurück zum Zitat Nii M, Roman KS, Kingdom J, Redington AN, Jaeggi ET: Assessment of the evolution of normal fetal diastolic function during mid and late gestation by spectral doppler tissue echocardiography. J Am Soc Echocardiogr. 2006, 19: 1431-1437. 10.1016/j.echo.2006.05.027.CrossRefPubMed Nii M, Roman KS, Kingdom J, Redington AN, Jaeggi ET: Assessment of the evolution of normal fetal diastolic function during mid and late gestation by spectral doppler tissue echocardiography. J Am Soc Echocardiogr. 2006, 19: 1431-1437. 10.1016/j.echo.2006.05.027.CrossRefPubMed
16.
Zurück zum Zitat Vogt M, Muller J, Elmenhorst J, Muhlbauer F, Oberhoffer R: Fetal color-coded tissue doppler echocardiography: experiences with the “tracking method” in normal fetuses. Eur J Obstet Gynecol Reprod Biol. 2012, 164: 10-14. 10.1016/j.ejogrb.2012.05.013.CrossRefPubMed Vogt M, Muller J, Elmenhorst J, Muhlbauer F, Oberhoffer R: Fetal color-coded tissue doppler echocardiography: experiences with the “tracking method” in normal fetuses. Eur J Obstet Gynecol Reprod Biol. 2012, 164: 10-14. 10.1016/j.ejogrb.2012.05.013.CrossRefPubMed
17.
Zurück zum Zitat Larsen LU, et al.: Systolic myocardial velocity alterations in the growth-restricted fetus with cerebroplacental redistribution. Ultrasound Obstet Gynecol. 2009, 34: 62-67.CrossRefPubMed Larsen LU, et al.: Systolic myocardial velocity alterations in the growth-restricted fetus with cerebroplacental redistribution. Ultrasound Obstet Gynecol. 2009, 34: 62-67.CrossRefPubMed
18.
Zurück zum Zitat Larsen LU, Petersen OB, Sloth E, Uldbjerg N: Color doppler myocardial imaging demonstrates reduced diastolic tissue velocity in growth retarded fetuses with flow redistribution. Eur J Obstet Gynecol Reprod Biol. 2011, 155: 140-145. 10.1016/j.ejogrb.2010.12.020.CrossRefPubMed Larsen LU, Petersen OB, Sloth E, Uldbjerg N: Color doppler myocardial imaging demonstrates reduced diastolic tissue velocity in growth retarded fetuses with flow redistribution. Eur J Obstet Gynecol Reprod Biol. 2011, 155: 140-145. 10.1016/j.ejogrb.2010.12.020.CrossRefPubMed
19.
Zurück zum Zitat Harada K, Tsuda A, Orino T, Tanaka T, Takada G: Tissue doppler imaging in the normal fetus. Int J Cardiol. 1999, 71: 227-234. 10.1016/S0167-5273(99)00152-7.CrossRefPubMed Harada K, Tsuda A, Orino T, Tanaka T, Takada G: Tissue doppler imaging in the normal fetus. Int J Cardiol. 1999, 71: 227-234. 10.1016/S0167-5273(99)00152-7.CrossRefPubMed
20.
Zurück zum Zitat Naujorks AA, et al.: Myocardial tissue doppler assessment of diastolic function in the growth-restricted fetus. Ultrasound Obstet Gynecol. 2009, 34: 68-73.CrossRefPubMed Naujorks AA, et al.: Myocardial tissue doppler assessment of diastolic function in the growth-restricted fetus. Ultrasound Obstet Gynecol. 2009, 34: 68-73.CrossRefPubMed
21.
Zurück zum Zitat Lingman G, et al.: Haemodynamic assessment of fetal heart arrhythmias. Br J Obstet Gynaecol. 1984, 91: 647-652. 10.1111/j.1471-0528.1984.tb04824.x.CrossRefPubMed Lingman G, et al.: Haemodynamic assessment of fetal heart arrhythmias. Br J Obstet Gynaecol. 1984, 91: 647-652. 10.1111/j.1471-0528.1984.tb04824.x.CrossRefPubMed
22.
Zurück zum Zitat Clur SA, Oude Rengerink K, Mol BW, Ottenkamp J, Bilardo CM: Is fetal cardiac function gender dependent?. Prenat Diagn. 2011, 31: 536-542. 10.1002/pd.2738.CrossRefPubMed Clur SA, Oude Rengerink K, Mol BW, Ottenkamp J, Bilardo CM: Is fetal cardiac function gender dependent?. Prenat Diagn. 2011, 31: 536-542. 10.1002/pd.2738.CrossRefPubMed
23.
Zurück zum Zitat Harada K, Ogawa M, Tanaka T: Right ventricular pre-ejection myocardial velocity and myocardial acceleration in normal fetuses assessed by doppler tissue imaging. J Am Soc Echocardiogr. 2005, 18: 370-374. 10.1016/j.echo.2004.10.017.CrossRefPubMed Harada K, Ogawa M, Tanaka T: Right ventricular pre-ejection myocardial velocity and myocardial acceleration in normal fetuses assessed by doppler tissue imaging. J Am Soc Echocardiogr. 2005, 18: 370-374. 10.1016/j.echo.2004.10.017.CrossRefPubMed
24.
Zurück zum Zitat Watanabe S, et al.: Characterization of ventricular myocardial performance in the fetus by tissue doppler imaging. Circ J. 2009, 73: 943-947. 10.1253/circj.CJ-08-0529.CrossRefPubMed Watanabe S, et al.: Characterization of ventricular myocardial performance in the fetus by tissue doppler imaging. Circ J. 2009, 73: 943-947. 10.1253/circj.CJ-08-0529.CrossRefPubMed
25.
Zurück zum Zitat Hayashi SY, et al.: Analysis of mitral annulus motion measurements derived from M-mode, anatomic M-mode, tissue Doppler displacement, and 2-dimensional strain imaging. J Am Soc Echocardiogr. 2006, 19: 1092-1101. 10.1016/j.echo.2006.04.014.CrossRefPubMed Hayashi SY, et al.: Analysis of mitral annulus motion measurements derived from M-mode, anatomic M-mode, tissue Doppler displacement, and 2-dimensional strain imaging. J Am Soc Echocardiogr. 2006, 19: 1092-1101. 10.1016/j.echo.2006.04.014.CrossRefPubMed
26.
Zurück zum Zitat Fraser AG, et al.: Feasibility and reproducibility of off-line tissue doppler measurement of regional myocardial function during dobutamine stress echocardiography. Eur J Echocardiogr. 2003, 4: 43-53. 10.1053/euje.4.1.43.CrossRefPubMed Fraser AG, et al.: Feasibility and reproducibility of off-line tissue doppler measurement of regional myocardial function during dobutamine stress echocardiography. Eur J Echocardiogr. 2003, 4: 43-53. 10.1053/euje.4.1.43.CrossRefPubMed
27.
Zurück zum Zitat Elmstedt E, Lind B, Ferm-Widlund K, Westgren M, Brodin L-Å: Reproducibility and variability in the assessment of color-coded tissue velocity imaging of the myocardium. J biomed graph comput. 2013, 3: 16-23. Elmstedt E, Lind B, Ferm-Widlund K, Westgren M, Brodin L-Å: Reproducibility and variability in the assessment of color-coded tissue velocity imaging of the myocardium. J biomed graph comput. 2013, 3: 16-23.
28.
Zurück zum Zitat Martensson M, Olsson M, Brodin LA: Ultrasound transducer function: annual testing is not sufficient. Eur J Echocardiogr. 2010, 11: 801-805. 10.1093/ejechocard/jeq072.CrossRefPubMed Martensson M, Olsson M, Brodin LA: Ultrasound transducer function: annual testing is not sufficient. Eur J Echocardiogr. 2010, 11: 801-805. 10.1093/ejechocard/jeq072.CrossRefPubMed
29.
Zurück zum Zitat Kapusta L, et al.: Second trimester ultrasound: reference values for two-dimensional speckle tracking-derived longitudinal strain, strain rate and time to peak deformation of the fetal heart. J Am Soc Echocardiogr. 2012, 25: 1333-1341. 10.1016/j.echo.2012.09.011.CrossRefPubMed Kapusta L, et al.: Second trimester ultrasound: reference values for two-dimensional speckle tracking-derived longitudinal strain, strain rate and time to peak deformation of the fetal heart. J Am Soc Echocardiogr. 2012, 25: 1333-1341. 10.1016/j.echo.2012.09.011.CrossRefPubMed
30.
Zurück zum Zitat Oki T, et al.: Effect of an acute increase in afterload on left ventricular regional wall motion velocity in healthy subjects. J Am Soc Echocardiogr. 1999, 12: 476-483. 10.1016/S0894-7317(99)70084-2.CrossRefPubMed Oki T, et al.: Effect of an acute increase in afterload on left ventricular regional wall motion velocity in healthy subjects. J Am Soc Echocardiogr. 1999, 12: 476-483. 10.1016/S0894-7317(99)70084-2.CrossRefPubMed
31.
Zurück zum Zitat Dincer I, et al.: Assessment of left ventricular diastolic function with doppler tissue imaging: effects of preload and place of measurements. Int J Cardiovasc Imaging. 2002, 18: 155-160. 10.1023/A:1014697208218.CrossRefPubMed Dincer I, et al.: Assessment of left ventricular diastolic function with doppler tissue imaging: effects of preload and place of measurements. Int J Cardiovasc Imaging. 2002, 18: 155-160. 10.1023/A:1014697208218.CrossRefPubMed
32.
Zurück zum Zitat Raboisson MJ, et al.: Early intertwin differences in myocardial performance during the twin-to-twin transfusion syndrome. Circulation. 2004, 110: 3043-3048. 10.1161/01.CIR.0000146896.20317.59.CrossRefPubMed Raboisson MJ, et al.: Early intertwin differences in myocardial performance during the twin-to-twin transfusion syndrome. Circulation. 2004, 110: 3043-3048. 10.1161/01.CIR.0000146896.20317.59.CrossRefPubMed
33.
Zurück zum Zitat Kaponis A, et al.: The importance of venous doppler velocimetry for evaluation of intrauterine growth restriction. J Ultrasound Med. 2011, 30: 529-545.PubMed Kaponis A, et al.: The importance of venous doppler velocimetry for evaluation of intrauterine growth restriction. J Ultrasound Med. 2011, 30: 529-545.PubMed
34.
Zurück zum Zitat Hernandez-Andrade E, Benavides-Serralde JA, Cruz-Martinez R, Welsh A, Mancilla-Ramirez J: Evaluation of conventional doppler fetal cardiac function parameters: E/a ratios, outflow tracts, and myocardial performance index. Fetal Diagn Ther. 2012, 32: 22-29. 10.1159/000330792.CrossRefPubMed Hernandez-Andrade E, Benavides-Serralde JA, Cruz-Martinez R, Welsh A, Mancilla-Ramirez J: Evaluation of conventional doppler fetal cardiac function parameters: E/a ratios, outflow tracts, and myocardial performance index. Fetal Diagn Ther. 2012, 32: 22-29. 10.1159/000330792.CrossRefPubMed
35.
Zurück zum Zitat Acharya G, et al.: Comparison between pulsed-wave doppler- and tissue doppler-derived Tei indices in fetuses with and without congenital heart disease. Ultrasound Obstet Gynecol. 2008, 31: 406-411. 10.1002/uog.5292.CrossRefPubMed Acharya G, et al.: Comparison between pulsed-wave doppler- and tissue doppler-derived Tei indices in fetuses with and without congenital heart disease. Ultrasound Obstet Gynecol. 2008, 31: 406-411. 10.1002/uog.5292.CrossRefPubMed
36.
Zurück zum Zitat Koga T, Athayde N, Trudinger B: The fetal cardiac isovolumetric contraction time in normal pregnancy and in pregnancy with placental vascular disease: the first clinical report using a new ultrasound technique. BJOG. 2001, 108: 179-185.PubMed Koga T, Athayde N, Trudinger B: The fetal cardiac isovolumetric contraction time in normal pregnancy and in pregnancy with placental vascular disease: the first clinical report using a new ultrasound technique. BJOG. 2001, 108: 179-185.PubMed
38.
Zurück zum Zitat Wiberg-Itzel E, et al.: Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trial. BMJ. 2008, 336: 1284-1287. 10.1136/bmj.39553.406991.25.CrossRefPubMedPubMedCentral Wiberg-Itzel E, et al.: Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trial. BMJ. 2008, 336: 1284-1287. 10.1136/bmj.39553.406991.25.CrossRefPubMedPubMedCentral
Metadaten
Titel
Reference values for fetal tissue velocity imaging and a new approach to evaluate fetal myocardial function
verfasst von
Nina NE Elmstedt
Jonas JJ Johnson
Britta BL Lind
Kjerstin KFW Ferm-Widlund
Lotta LH Herling
Magnus MW Westgren
Lars-Åke LAB Brodin
Publikationsdatum
01.12.2013
Verlag
BioMed Central
Erschienen in
Cardiovascular Ultrasound / Ausgabe 1/2013
Elektronische ISSN: 1476-7120
DOI
https://doi.org/10.1186/1476-7120-11-29

Weitere Artikel der Ausgabe 1/2013

Cardiovascular Ultrasound 1/2013 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.