Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 2/2018

23.11.2017 | Original Article

Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention

verfasst von: Dongkue Kim, Sangsoo Park, Myung Ho Jeong, Jeha Ryu

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI.

Methods

The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration.

Results

A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes \(\sim \) 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz.

Conclusions

By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.
Literatur
1.
Zurück zum Zitat Baims DS, Grossman W (2013) GROSSMAN and BAIM’S cardiac catheterization, angiography, and intervention, 8th edn. Lippincott Williams & Wilkins, Philadelphia Baims DS, Grossman W (2013) GROSSMAN and BAIM’S cardiac catheterization, angiography, and intervention, 8th edn. Lippincott Williams & Wilkins, Philadelphia
2.
Zurück zum Zitat Wang P, Chen T, Zhu Y, Zhang W, Zhou SK, Comaniciu D (2009) Robust guidewire tracking in fluoroscopy. In: IEEE computer society conference on computer vision and pattern recognition, 2009 (CVPR 2009), pp 691–698 Wang P, Chen T, Zhu Y, Zhang W, Zhou SK, Comaniciu D (2009) Robust guidewire tracking in fluoroscopy. In: IEEE computer society conference on computer vision and pattern recognition, 2009 (CVPR 2009), pp 691–698
3.
Zurück zum Zitat Pauly O, Heibel H, Navab N (2010) A machine learning approach for deformable guide-wire tracking in fluoroscopic sequences. In: Lecture notes in computer science (including Subseries lecture notes in artificial intelligence, lecture notes in bioinformatics), vol 6363. LNCS, pp 343–350 Pauly O, Heibel H, Navab N (2010) A machine learning approach for deformable guide-wire tracking in fluoroscopic sequences. In: Lecture notes in computer science (including Subseries lecture notes in artificial intelligence, lecture notes in bioinformatics), vol 6363. LNCS, pp 343–350
4.
Zurück zum Zitat Heibel H, Glocker B, Groher M, Pfister M, Navab N (2013) Interventional tool tracking using discrete optimization. IEEE Trans Med Imaging 32:544–555CrossRefPubMed Heibel H, Glocker B, Groher M, Pfister M, Navab N (2013) Interventional tool tracking using discrete optimization. IEEE Trans Med Imaging 32:544–555CrossRefPubMed
5.
Zurück zum Zitat Chang P, Rolls A, De Praetere H, Poorten EV, Riga CV, Bicknell CD, Stoyanov D (2016) Robust catheter and guidewire tracking using B-Spline tube model and pixel-wise posteriors. IEEE Robot Autom Lett 1:303–308CrossRef Chang P, Rolls A, De Praetere H, Poorten EV, Riga CV, Bicknell CD, Stoyanov D (2016) Robust catheter and guidewire tracking using B-Spline tube model and pixel-wise posteriors. IEEE Robot Autom Lett 1:303–308CrossRef
6.
Zurück zum Zitat Ruijters D, ter Haar Romeny BM, Suetens P (2009) Vesselness-based 2D–3D registration of the coronary arteries. Int J Comput Assist Radiol Surg 4:391–397CrossRefPubMed Ruijters D, ter Haar Romeny BM, Suetens P (2009) Vesselness-based 2D–3D registration of the coronary arteries. Int J Comput Assist Radiol Surg 4:391–397CrossRefPubMed
7.
Zurück zum Zitat Duong L, Liao R, Sundar H, Tailhades, B, Meyer, A, Xu, C (2009) Curve-based 2D-3D registration of coronary vessels for image guided procedure. In: Proceedings of the SPIE Medical Imaging, p 7261 Duong L, Liao R, Sundar H, Tailhades, B, Meyer, A, Xu, C (2009) Curve-based 2D-3D registration of coronary vessels for image guided procedure. In: Proceedings of the SPIE Medical Imaging, p 7261
8.
Zurück zum Zitat Rivest-Henault D, Sundar H, Cheriet M (2012) Nonrigid 2D/3D registration of coronary artery models with live fluoroscopy for guidance of cardiac interventions. IEEE Trans Med Imaging 31:1557–1572CrossRefPubMed Rivest-Henault D, Sundar H, Cheriet M (2012) Nonrigid 2D/3D registration of coronary artery models with live fluoroscopy for guidance of cardiac interventions. IEEE Trans Med Imaging 31:1557–1572CrossRefPubMed
9.
Zurück zum Zitat Benseghir T, Malandain G, Vaillant R (2015) A tree-topology preserving pairing for 3D/2D registration. Int J Comput Assist Radiol Surg 10:913–923 Benseghir T, Malandain G, Vaillant R (2015) A tree-topology preserving pairing for 3D/2D registration. Int J Comput Assist Radiol Surg 10:913–923
10.
Zurück zum Zitat Metz CT, Schaap M, Klein S, Neefjes L, Capuano E, Schultz C, van Geuns RJ, Serruys PW, van Walsum T, Niessen WJ (2009) Patient specific 4D coronary models from ECG-gated CTA data for intra-operative dynamic alignment of CTA with X-ray images. In: Lecture notes in computer science (Including subseries lecture notes in artificial intelligence, lecture notes in bioinformatics), vol 5761. LNCS, pp 369–376 Metz CT, Schaap M, Klein S, Neefjes L, Capuano E, Schultz C, van Geuns RJ, Serruys PW, van Walsum T, Niessen WJ (2009) Patient specific 4D coronary models from ECG-gated CTA data for intra-operative dynamic alignment of CTA with X-ray images. In: Lecture notes in computer science (Including subseries lecture notes in artificial intelligence, lecture notes in bioinformatics), vol 5761. LNCS, pp 369–376
11.
Zurück zum Zitat Baka N, Metz CT, Schultz C, Neefjes LA, van Geunsc RJ, Lelieveldt BPF, Niessen WJ, van Walsum T, de Bruijne M (2013) Statistical coronary motion models for 2D + t/3D registration of X-ray coronary angiography and CTA. Med Image Anal 17:698–709CrossRefPubMed Baka N, Metz CT, Schultz C, Neefjes LA, van Geunsc RJ, Lelieveldt BPF, Niessen WJ, van Walsum T, de Bruijne M (2013) Statistical coronary motion models for 2D + t/3D registration of X-ray coronary angiography and CTA. Med Image Anal 17:698–709CrossRefPubMed
12.
Zurück zum Zitat Metz CT, Schaap M, Klein S, Baka N, Neefjes LA, Schultz CJ, Niessen WJ, van Walsum T (2013) Registration of 3D + t Coronary CTA and monoplane 2D + t X-ray angiography. IEEE Trans Med Imaging 32(5):919–931CrossRefPubMed Metz CT, Schaap M, Klein S, Baka N, Neefjes LA, Schultz CJ, Niessen WJ, van Walsum T (2013) Registration of 3D + t Coronary CTA and monoplane 2D + t X-ray angiography. IEEE Trans Med Imaging 32(5):919–931CrossRefPubMed
13.
Zurück zum Zitat Schneider M (2010) Model-based respiratory motion compensation for image-guided cardiac interventions. Ph.D. Dissertation, University of Friedrich-Alexander Schneider M (2010) Model-based respiratory motion compensation for image-guided cardiac interventions. Ph.D. Dissertation, University of Friedrich-Alexander
14.
Zurück zum Zitat Besl P, McKay N (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14:239–256CrossRef Besl P, McKay N (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14:239–256CrossRef
15.
Zurück zum Zitat Lanzer P, Barta C, Botvinick EH, Wiesendanger HU, Modin G, Higgins CB (1985) ECG-synchronized cardiac MR imaging: method and evaluation. Radiology 155(3):681–686CrossRefPubMed Lanzer P, Barta C, Botvinick EH, Wiesendanger HU, Modin G, Higgins CB (1985) ECG-synchronized cardiac MR imaging: method and evaluation. Radiology 155(3):681–686CrossRefPubMed
16.
Zurück zum Zitat Shechter G, Ozturk C, Resar JR, McVeigh ER (2004) Respiratory motion of the heart from free breathing coronary angiograms. IEEE Trans Med Imaging 23:1046–1056CrossRefPubMedPubMedCentral Shechter G, Ozturk C, Resar JR, McVeigh ER (2004) Respiratory motion of the heart from free breathing coronary angiograms. IEEE Trans Med Imaging 23:1046–1056CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Shechter G, Resar JR, McVeigh ER (2006) Displacement and velocity of the coronary arteries: cardiac and respiratory motion. IEEE Trans Med Imaging 25:369–375CrossRefPubMedPubMedCentral Shechter G, Resar JR, McVeigh ER (2006) Displacement and velocity of the coronary arteries: cardiac and respiratory motion. IEEE Trans Med Imaging 25:369–375CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: International conference on medial image computing and computer-assisted intervention, pp 130–137 Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: International conference on medial image computing and computer-assisted intervention, pp 130–137
19.
Zurück zum Zitat Suzuki S, Abe K (1985) Topological structural analysis of digitized binary images by border following. Comput Vis Graph 30(1):32–46CrossRef Suzuki S, Abe K (1985) Topological structural analysis of digitized binary images by border following. Comput Vis Graph 30(1):32–46CrossRef
20.
Zurück zum Zitat Gonzalez RC, Woods RE (2002) Digital image processing, 2nd edn. Prentice Hall, Upper Saddle River Gonzalez RC, Woods RE (2002) Digital image processing, 2nd edn. Prentice Hall, Upper Saddle River
21.
Zurück zum Zitat Sundar H, Khamene A, Xu C, Sauer F, Davatzikos C (2006) A novel 2D–3D registration algorithm for aligning fluoro images with 3D pre-op CT/MR images. In: Proceedings of the SPIE medical imaging, p 6141 Sundar H, Khamene A, Xu C, Sauer F, Davatzikos C (2006) A novel 2D–3D registration algorithm for aligning fluoro images with 3D pre-op CT/MR images. In: Proceedings of the SPIE medical imaging, p 6141
22.
Zurück zum Zitat Baher H (1990) Analog and digital signal processing. Wiley, Hoboken Baher H (1990) Analog and digital signal processing. Wiley, Hoboken
Metadaten
Titel
Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention
verfasst von
Dongkue Kim
Sangsoo Park
Myung Ho Jeong
Jeha Ryu
Publikationsdatum
23.11.2017
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 2/2018
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1689-z

Weitere Artikel der Ausgabe 2/2018

International Journal of Computer Assisted Radiology and Surgery 2/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.