Skip to main content
Erschienen in: European Radiology 9/2016

10.12.2015 | Cardiac

Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT

verfasst von: David Viladés Medel, Rubén Leta, Xavier Alomar Serralach, Francesc Carreras Costa, Guillem Pons-Lladó

Erschienen in: European Radiology | Ausgabe 9/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To investigate the feasibility and diagnostic accuracy of subtraction CTA on patients with highly calcified coronary artery disease (CAD) or previous implanted stents, in comparison with invasive coronary angiography (ICA).

Materials and methods

Twenty-three patients were recruited. All conventional and subtraction CTA exams were performed using a 320-row CT. Subjective image quality score was assessed for each segment using a 4-point scale: 1-uninterpretable to 4-good image quality.

Results

A total of 129 calcified or stented coronary segments were studied. Mean coronary image quality with conventional CTA was 2.73 ± 0.97 and in subtracted CTA 3.3 ± 0.92 (p < 0.01). After metal subtraction, image quality in stented coronary segments with >3 mm of diameter improved from 2.69 ± 0.97 to 3.34 ± 0.89 (p = 0.01) and in those with <3 mm of diameter from 2.11 ± 0.78 to 2.67 ± 0.87 (p = 0.17). There was an improvement in diagnostic accuracy to detect ICA stenosis >50 % by subtraction CTA compared with conventional CTA (AUC 0.93 to 0.87; p = 0.02).

Conclusion

Subtraction CTA is promising in overcoming limitations of conventional CTA due to calcium or metal artefacts, especially if no motion artefact is present or when stents > 3 mm are studied.

Key Points

Calcium and metal artefacts are still a limitation for conventional coronary CTA
Diagnostic accuracy is improved by subtraction as compared with conventional CTA
Subtraction CTA is a promising tool to overcome limitations of conventional CTA
Literatur
1.
Zurück zum Zitat Members TF, Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C et al (2013) 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J 34:2949–3003CrossRef Members TF, Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C et al (2013) 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J 34:2949–3003CrossRef
2.
Zurück zum Zitat Hamm CW, Bassand J-P, Agewall S, Bax J, Boersma E, Bueno H et al (2011) ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: the Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevatio. Eur Heart J 32:2999–3054CrossRefPubMed Hamm CW, Bassand J-P, Agewall S, Bax J, Boersma E, Bueno H et al (2011) ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: the Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevatio. Eur Heart J 32:2999–3054CrossRefPubMed
3.
Zurück zum Zitat Stolzmann P, Scheffel H, Leschka S, Plass A, Baumüller S, Marincek B et al (2008) Influence of calcifications on diagnostic accuracy of coronary CT angiography using prospective ECG triggering. AJR Am J Roentgenol 191:1684–1689CrossRefPubMed Stolzmann P, Scheffel H, Leschka S, Plass A, Baumüller S, Marincek B et al (2008) Influence of calcifications on diagnostic accuracy of coronary CT angiography using prospective ECG triggering. AJR Am J Roentgenol 191:1684–1689CrossRefPubMed
4.
Zurück zum Zitat Vavere AL, Arbab-Zadeh A, Rochitte CE, Dewey M, Niinuma H, Gottlieb I et al (2011) Coronary artery stenoses: accuracy of 64–detector row CT angiography in segments with mild, moderate, or severe calcification—a subanalysis of the CORE-64 trial. Radiology 261:100–108CrossRefPubMedPubMedCentral Vavere AL, Arbab-Zadeh A, Rochitte CE, Dewey M, Niinuma H, Gottlieb I et al (2011) Coronary artery stenoses: accuracy of 64–detector row CT angiography in segments with mild, moderate, or severe calcification—a subanalysis of the CORE-64 trial. Radiology 261:100–108CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Abdulla J, Pedersen KS, Budoff M, Kofoed KF (2012) Influence of coronary calcification on the diagnostic accuracy of 64-slice computed tomography coronary angiography: a systematic review and meta-analysis. Int J Cardiovasc Imaging 28:943–953CrossRefPubMed Abdulla J, Pedersen KS, Budoff M, Kofoed KF (2012) Influence of coronary calcification on the diagnostic accuracy of 64-slice computed tomography coronary angiography: a systematic review and meta-analysis. Int J Cardiovasc Imaging 28:943–953CrossRefPubMed
6.
Zurück zum Zitat Meijboom WB, van Mieghem C a G, Mollet NR, Pugliese F, Weustink AC, van Pelt N et al (2007) 64-slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease. J Am Coll Cardiol 50:1469–1475CrossRefPubMed Meijboom WB, van Mieghem C a G, Mollet NR, Pugliese F, Weustink AC, van Pelt N et al (2007) 64-slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease. J Am Coll Cardiol 50:1469–1475CrossRefPubMed
7.
Zurück zum Zitat Yan RT, Miller JM, Rochitte CE, Dewey M, Niinuma H, Clouse ME et al (2013) Predictors of inaccurate coronary arterial stenosis assessment by CT angiography. JACC Cardiovasc Imaging 6:963–972CrossRefPubMedPubMedCentral Yan RT, Miller JM, Rochitte CE, Dewey M, Niinuma H, Clouse ME et al (2013) Predictors of inaccurate coronary arterial stenosis assessment by CT angiography. JACC Cardiovasc Imaging 6:963–972CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Park HB, Lee BK, Shin S, Heo R, Arsanjani R, Kitslaar PH et al (2015) Clinical Feasibility of 3D Automated Coronary Atherosclerotic Plaque Quantification Algorithm on Coronary Computed Tomography Angiography: Comparison with Intravascular Ultrasound. Eur Radiol 25:3073–3083CrossRefPubMed Park HB, Lee BK, Shin S, Heo R, Arsanjani R, Kitslaar PH et al (2015) Clinical Feasibility of 3D Automated Coronary Atherosclerotic Plaque Quantification Algorithm on Coronary Computed Tomography Angiography: Comparison with Intravascular Ultrasound. Eur Radiol 25:3073–3083CrossRefPubMed
9.
Zurück zum Zitat Rixe J, Achenbach S, Ropers D, Baum U, Kuettner A, Ropers U et al (2006) Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography. Eur Heart J 27:2567–2572CrossRefPubMed Rixe J, Achenbach S, Ropers D, Baum U, Kuettner A, Ropers U et al (2006) Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography. Eur Heart J 27:2567–2572CrossRefPubMed
10.
Zurück zum Zitat Andreini D, Pontone G, Bartorelli AL, Mushtaq S, Trabattoni D, Bertella E et al (2011) High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: In-stent restenosis assessment by low-dose MDCT. Eur Radiol 21:1430–1438CrossRefPubMed Andreini D, Pontone G, Bartorelli AL, Mushtaq S, Trabattoni D, Bertella E et al (2011) High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: In-stent restenosis assessment by low-dose MDCT. Eur Radiol 21:1430–1438CrossRefPubMed
11.
Zurück zum Zitat Dewey M, Zimmermann E, Deissenrieder F, Laule M, Dübel H-P, Schlattmann P et al (2009) Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation 120:867–875CrossRefPubMed Dewey M, Zimmermann E, Deissenrieder F, Laule M, Dübel H-P, Schlattmann P et al (2009) Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation 120:867–875CrossRefPubMed
12.
Zurück zum Zitat De Graaf FR, Schuijf JD, van Velzen JE, Kroft LJ, de Roos A, Reiber JHC et al (2010) Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease. Eur Heart J 31:1908–1915CrossRefPubMed De Graaf FR, Schuijf JD, van Velzen JE, Kroft LJ, de Roos A, Reiber JHC et al (2010) Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease. Eur Heart J 31:1908–1915CrossRefPubMed
13.
Zurück zum Zitat Tanaka R, Yoshioka K, Muranaka K, Chiba T, Ueda T, Sasaki T et al (2013) Improved evaluation of calcified segments on coronary CT angiography: a feasibility study of coronary calcium subtraction. Int J Cardiovasc Imaging 29:75–81CrossRefPubMed Tanaka R, Yoshioka K, Muranaka K, Chiba T, Ueda T, Sasaki T et al (2013) Improved evaluation of calcified segments on coronary CT angiography: a feasibility study of coronary calcium subtraction. Int J Cardiovasc Imaging 29:75–81CrossRefPubMed
14.
Zurück zum Zitat Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500–507CrossRefPubMed Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500–507CrossRefPubMed
15.
Zurück zum Zitat Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832CrossRefPubMed Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832CrossRefPubMed
16.
Zurück zum Zitat Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40CrossRefPubMed Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40CrossRefPubMed
17.
Zurück zum Zitat MEMBERS WC, Budoff MJ, Cohen MC, Garcia MJ, Hodgson JM, Hundley WG et al (2005) ACCF/AHA clinical competence statement on cardiac imaging with computed tomography and magnetic resonance: a report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competenc. Circulation 112:598–617CrossRef MEMBERS WC, Budoff MJ, Cohen MC, Garcia MJ, Hodgson JM, Hundley WG et al (2005) ACCF/AHA clinical competence statement on cardiac imaging with computed tomography and magnetic resonance: a report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competenc. Circulation 112:598–617CrossRef
18.
Zurück zum Zitat Zou KH, O’Malley AJ, Mauri L (2007) Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models. Circulation 115:654–657CrossRefPubMed Zou KH, O’Malley AJ, Mauri L (2007) Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models. Circulation 115:654–657CrossRefPubMed
19.
Zurück zum Zitat Yoshioka K, Tanaka R, Muranaka K (2012) Subtraction coronary CT angiography for calcified lesions. Cardiol Clin 30:93–102CrossRefPubMed Yoshioka K, Tanaka R, Muranaka K (2012) Subtraction coronary CT angiography for calcified lesions. Cardiol Clin 30:93–102CrossRefPubMed
20.
Zurück zum Zitat Geleijns J, Joemai RMS, Dewey M, De Roos A, Zankl M, Cantera AC et al (2011) Radiation exposure to patients in a multicenter coronary angiography trial (CORE 64). AJR Am J Roentgenol 196:1126–1132CrossRefPubMed Geleijns J, Joemai RMS, Dewey M, De Roos A, Zankl M, Cantera AC et al (2011) Radiation exposure to patients in a multicenter coronary angiography trial (CORE 64). AJR Am J Roentgenol 196:1126–1132CrossRefPubMed
Metadaten
Titel
Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT
verfasst von
David Viladés Medel
Rubén Leta
Xavier Alomar Serralach
Francesc Carreras Costa
Guillem Pons-Lladó
Publikationsdatum
10.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 9/2016
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-015-4130-4

Weitere Artikel der Ausgabe 9/2016

European Radiology 9/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.